Boeing 757-200 SERIES
Service difficulty reports · 2,032
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757200' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757200' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IXXA20230421001Spar · corrodedR/H WING O/B T/E AFT SPAR LOWER CHORD HAS CORROSION BETWEEN APPROX. W/S 820 TO 832.SDR FDEA202304200774Panel · delaminatedL/W L/E PANEL 511HB IS DELAMINATED ON CORNER REPAIRED 2EA DELAMINATED CORNERS ON PANEL 511HB IAW B757 SRM 57-41-01-2R, AMD B757 SRM 51-70-08-0G. REPLACED EROSION STRIP IN REPAIR AREA IAW B757 SRM 57-41-01-2R REPAIR 2. REPLACED FOIL BACKING IAW BAC DWG 11SDR CALA2023042101196Life Raft · damagedUPON RELOCATION OF THE OVERHEAD BIN DIVIDER FOUND THAT THE LIFE RAFT LOCATED IN OVERHEAD BIN AT 11ABC AREA TO BE UNRAVELED AT THE SURROUNDING SEAM. SUPPORT TASK NSA EMX N/R 00153. REMOVED AND REPLACED LIFE RAFT IN OVERHEAD BIN OFF P/N 63800-103 OFF S/N L5372 OSDR FDEA202304200726Unknown · unknownEMERGENCY DECLARED FOR TE FLAP DISAGREE. FLAP EXTENSION NORMAL TO 15 DEGREES. AT APPROX 175 KNOTS WE SELECTED FLAPS 20. THE FLAP INDICATOR MOVED TO APPROX 17 DEGREES AND STOPPED. TE FLAP DISAG EICAS MESSAGE WAS DISPLAYED. RAN QRH PROCEDURE AND LANDED WISDR FDEA202304200725Roller · misalignedPDIS 921 52-10 0900 20APR23 FAT FACT U L FWD ENTRY DOOR EICAS CAME ON DURING DEPARTURE PASSING APPROX 3000 . RAN QRH AND CONTINUED NORMAL OPS AS PRESSURIZATION REMAINED NORMAL. EICAS WENT OUT BEFORE REACHING CRUISE ALTITUDE. IT CAME BACK OSDR FDEA202304200723Unknown · unknownFUSELAGE SKIN AT STA 1600 - 1620 STR1R/2R DENTED. ACCOMPLISHED FEDEX EA# F-5330-T0374201: FUSELAGE - PLATES AND SKIN - STA 1609 -S-1 - S- 2R, DENT REPAIR DOUBLER.SDR FDEA202304190704Unknown · crackedAFT CARGO DOOR LOWER SILL FWD CORNER LOWER CHORD IS CRACKED. ALL STEPS COMPLIED WITH IAW EA TF-5310-T0313798 FUSELAGE / MAIN FRAME - EXISTING REPAIR AT FUSELAGE NO 2 CARGO DOORWAY LOWER MAIN OUTBOARD CHORD BETWEEN BS 1380 TO BS 1436 MAJOR REPAIRSDR FDEA202304180773Panel · delaminatedL. WING L/E PANEL 511DB IS DELAMINATED AND COMPOSITE DAMAGE ON THE CORNER REPAIRED DELAMINATION AND COMPOSITE DAMAGE ON LEFT WING L/E PANEL 511DB IAW B757 SRM 57-41-01-2R, 57-41-01-0I, 51-05-01, PART 1, 51-70-17-OG, AND 51-70-04-OG.SDR FDEA202304170800Floorbeam · crackedFOUND CRACK ON FLOOR BEAM AT STA 580 AT LBL 45 ON UPPER FLANGE LOWER AREA WORK ACCOMPLISHED IN ACCORDANCE WITH FEDEX E.A# F-5310-T0374058-FLOOR BEAM AT STA 580 AND LBL 45- CRACKED-REPAIR PER DRAWING SR 57-53-004-TRACKING MAJOR REPAIRSDR CALA2023041901156Beam · corroded(SUPPORT TASK) MAIN CABIN FLOOR BEAM STA 324 RBL 45 UPPER SURFAC E CORRODED. TRANSCRIBED FROM HAECO GSO NR 9280358. HAECO GSO MECH V900838 INSP QC204 REPAIRED STA 324 UPPER 7 CHORD IAW B757-200 SRM 53-10-08-2R-1 RE PAIR 1 FIG 201 THIS IS A CATEGORY B REPAIR.SDR FDEA202304160703Flap · damagedR/H WING INBD FLAP INNER SIDE NEAR MIDDLE SUPPORT HAS A SMALL HOLE "1/4 PERFORMED WET LAYUP REPAIR FOR MENTIONED AREA OF MAIN FLAP PER SRM 51-70-06,PARAGRAPH 5.B. REF. SRM 57-53-01-2R,FIG.201, DETAIL I,TABLE III.REP. DIM. : 5.5" X 5.5". REP. LOC.: 4" FROM TSDR FDEA202304140648Lamp · burnedDURING SERVICE CHECK, FOUND R1 DOOR AND FLIGHT DECK DOOR OVERHEAD EMERGENCY LIGHTS SIGN (QTY:2) INOPERATIVE. RELEASED FOR SERVICE PER MEL : 33-51-01-01 CATEGORY : D EXPIRATION : 12AUG23 "MEL 33-51-01-01: INTERIOR EMERGENCY LIGHTS - INOP."MEL: 33-51-01-01SDR FDEA202304130639Unknown · unknownUPON SELECTING FLAPS 25, TE FLAP DISAGREE MESSAGE. COMPLIED WITH QRH. LANDED WITH FLAPS 20, LANDING SPEED 138. EMERGENCY DECLARED. ACCOMPLISHED FSEU BITE CHECKS AND FOUND FSEU 1 WITH A FLAP DISAGREE FAULT. INSPECTED TE FLAP SYSTEM AND FOUND L/H OUTBD FLASDR CALA2023041401124Fuse · openAFT 2 BULLNOSE EMERGENCY LIGHTS ON RIGHT SIDE DO NOT LIGHT DURING EMERGENCY LIGHT TEST. SUPPORT TASK NSA EMX NR 00209. FUSES AT EMERGENCY POWER SUPPLY. REMOVED AND REPLACED FUSE IAW B757 AMM 33-51-07 PERFORMED OPS CHECK GOOD IAW B757 AMM 33-51-07.SDR FDEA202304130634Unknown · unknownDURING PREFLIGHT MAIN SMOKE SYSTEM TEST EICAS MESSAGE MAIN CARGO FIRE NOT DISPLAYED MEL 13APR23 00:03 BIL U RELEASED FOR SERVICE PER MEL : 26-16-02-01-B CATEGORY : C EXPIRATION : 23APR23 "MEL 26-16-02-01-B: BOTH MAIN DECK CARGO COMPARTMENT SMOKE LOOPSSDR CALA2023041401117Beam · corroded(SUPPORT TASK) MAIN CABIN STA 1640 BL0 PREVIOUS TCAP REPAIR CORRODED ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NR 9280466. ENTERED IN ERRORSDR CALA2023041401114Switch · inoperativeEMERGENCY LIGHTING TEST SWITCH ABOVE L2 DOOR DOES NOT INITIATE TEST. EMERGENCY LIGHTING FUNCTIONS NORMALLY. SUPPORT TASK NSA EMX NR 00004SDR FDEA202304120630Unknown · unknownPDIS 974 27-50 9266 12APR23 MEM FACT U ON APPROACH AT FLAP EXTENSION TO FLAPS 1, RECEIVED A TE FLAP DISAGREE. DISCONTINUED APPROACH. COMPLIED WITH THE QRH, DECLARED AN EMERGENCY CHOSE 36C INSTEAD OF 36L. THE ALTERNATE SLAT/FLAP SYSTEM WORKESDR CALA2023041201103Control Unit · inoperativeLEFT ENGINE ELC LIMITER AT START OF TAKE OFF ROLL. LEFT ENGINE LIMITER INOP, CREW COMPLIED WITH MEL PROCEDURES. REJECTED TAKE OFF WAS LESS THAN 50 KNOTS, LOW ENERGY WITH NO HOT BRAKES. DEFERRED DIRECTLY BY TOMC PERFORMING ENGINE RUN ENG EEC MSG WAS OBSERVED ONSDR FDEA202304110642Girt Bar · damagedTHE SLIDE LIGHT ON THE L1 ENTRY DOOR IS BURNED OUT. DOES NOT ILLUMINATE WHEN DOOR ARMED AND BULB TESTS BAD DURING INSPECTION OF L1 DOOR GIRT BAR, FOUND LEAF SPRING ON GIRT BAR DAMAGED AND OBSTRUCTING FWD GIRT BAR SLIDER. REMOVED AND REPLACED GIRT BAR ASSSDR FDEA202304100611Frame · crackedMAIN DECK LH STA 1640 S-14L FRAME IS DAMAGED ON THE EDGE. FUSELAGE-MAINFRAME-FRAME, STA 1640, S-14L, EO F-5310-E0329085 FINDING- CRACK REPAIR- PARTIAL FRAME REPLACEMENT. ACCOMPLISHED STEPS 1-18 WITH NO DEVIATION PER EA F-5310- T0373488. MAJOR REPAIRSDR FDEA202304100610Panel · damagedAFT CARGO AREA STA 1360 HAS A EXISTING REPAIR BETWEEN STR 25-28L. REMOVED TRANSITION PANEL FOR ACCESS AND REINSTALLED TRANSITION PANEL IAW B757 SRM 51-40-02-06 AT AFT CARGO, L/H SIDE STA 1310-1410. TITLE: FUSELAGE-MAINFRAME-EXISTING REPAIR FOUND ON STA 136SDR FDEA202304070603Slide · looseDURING SERVICE CHECK FOUND RIGHT PASSENGER ACCES DOOR LIFE RAFT LOOSE AND GIRT BAR OUT OF PLACE. UPDT 07APR23 06:51 BCN U AMM 25-66-01-4 NO DAMAGE OBSERVED, ONLY LIFE RAFT OUT OF PLACE. STOWED RAFT IN CARGO AREA INSIDE CARGO NET WITH SAFETY LOCKING PINSDR FDEA202304070595Collar · damagedGUST LOCK BROKEN AT LEFT ENTRY DOOR. PART 07APR23 16:15 GSO U IDENTIFIED PARTS L1 DOOR COLLAR ASSY. REPLACED HOLD OPEN COLLAR AND CATCH. CKS GOOD.SDR FDEA202304070588Skin · damagedR/H EXTERIOR FUSELAGE SKIN DOUBLER HAS 2EA DENTS BETWEEN BS 540 AND BS 560 AND STRINGER S-22R AND STRINGER S23R REPAIRED PER FEDEX EA # F-5330-165083-P3SDR FDEA202304060575Angle · corrodedAREA OF AFT CARGO COMPARTMENT, MAIN CABIN FLOOR SUPPORT STRUCTURE AND NUTSTRIP ARE CORRODED BETWEEN STA 1701 AND 1720 APPROX RBL 13 REMOVED AND REPLACED ANGLE (FLOOR SUPPORT) AND NUTPLATE STRIP IAW BAC DWG 146N5300 REC C 140N2524 REV A, B757 SRM 51-40-02SDR FDEA202304060573Angle · corrodedAREA OF THE BULK CARGO COMPARTMENT, MAIN CABIN FLOOR SUPPORT STRUCTURE AND NUTSTRIP ARE CORRODED BETWEEN STA 1701 AND 1720 APPROX LBL5 REMOVED AND REPLACED ANGLE ( FLOOR SUPPORT) WITH NUTPLATE STRIP IAW BAC DWG 146N5300 REV C 140N2524 REV A B757 SRM SDR FDEA202304060572Angle · corrodedAREA AFT OF THE BULK CARGO COMPARTMENT, MAIN CABIN FLOOR SUPPORT STRUCTURE & NUT STRIP ARE CORRODED BETWEEN STA 1701 & 1720 APPROX RBL 5 REMOVED AND REPLACED FLOOR SUPPORT AND NUTPLATE STRIP IAW B757 SRM 51-40-02-0G AND BAC DWG 146N5300 REV C AND 140N2524 SDR FDEA202304060571Panel · delaminatedR.WING L/E PANEL 611DB HAS COMPOSITE DAMAGE ON MULTIPLE AREAS. ACCOMPLISHED PERMANENT REPAIR ON R/W L/E PANEL 611DB COMPOSITE DAMAGE PER B757 SRM 57-41-01-4R, 51-70-08-0G AND FIG 201, AND BOEING DWG 114N1523 REV DSDR FDEA202304060570Panel · delaminated#1 PYLON PANEL 432AL AFT 2 CORNERS ARE DELAMINATED AND DAMAGED. ACCOMPLISHED PERMANENT REPAIR OF PANEL PER B757 SRM 51-40-02, 54-50-70-0G, 51-70-17-0G AND BOEING DWG 313N5003.SDR FDEA202304050567Duct · damagedAT FL 350 WE RECEIVED A CABIN ALTITUDE WARNING MESSAGE. AFTER DONNING MASKS WE RAN THE QRC AND THEN RAN QRH 2.1.1. WHILE RUNNING THE CABIN ALTITUDE EMERGENCY CHECKLIST WE CONFIRMED THE CABIN ALTITUDE WAS 11000 AND CLIMBING. FROM THERE WE COMMENCED AN ESDR CALA2023040401042Unknown · lowALL 4 LAVS INOP WATER PRESSURE LOW RAMP SERVICED AFT TOILETS BEFORE MX ARRIVED HOWEVER FORWARD TOILET WAS FOUND TO BE NOT PRIOR SERVICED. VERIFIED FORWARD TOILET HAD NOT BEEN SERVICED , AFTER RAMP SERVICE TOILET WORKS NORMAL WITH NO DEFECTS . UNABLE TO VERIFY SDR FDEA202304040559Drag Fitting · unknownWHILE PERFORMANCE OPEN HOLE INSPECTION OF LH UPPER SKIN AND DRAG FITTING FOUND HOLE #3 INDICATION AT APPROX 3 O'CLOCK FACING FWD REFER TO TABLE 1 FOR DAMAGE DEPTH AND HOLE DIA. REPAIR COMPLIED WITH IAW EA # F-5730-T0373597 P1 ON HOLE #3, LH UPPER SKIN ANSDR FDEA202304040558Drag Fitting · unknownWHILE PERFORMANCE OPEN HOLE INSPECTION OF LH UPPER SKIN AND DRAG FITTING FOUND HOLE # 4 INDICATION AT APPROX. 10 O'CLOCK FACING FWD REFER TO TABLE 1 FOR DAMAGE DEPTH AND HOLE DIA. REPAIR COMPLIED WITH IAW EA # F-5730-T0373597 P1 ON HOLE #4, LH UPPER SKIN SDR FDEA202304020545Battery Pack · inoperativeMDIS 954 33-50 8488 02APR23 BNA OPEN U LT EMERGENCY SLIDE ILLUMINATION LIGHT INOP SHGN 02APR23 17:43 BNA U AMM: 33-51-06-2-1 REMOVED AND REPLACED BULB NO HELP PER LISTED AMM. NOTICED LIGHT ABOVE DOOR BRIEFLY STAYED ON DURING TEST, BUT DID SDR CALA2023040300998Pca · unknownR HYD QTY EICAS MSG WITH LOW PRESS. QRH COMPLIED WITH. AFTER OPERATING THE RIGHT HYDRAULICS FOUND THE #7 GROUND SPOILER NEEDS P/N 75-2763-9-0002 UPD PHOTO. INFO FROM THE CREW AT EWR ARRIVAL: ON PREFLIGHT R HYD SYS QTY ADDED ROTABLE PARTS INFO. ACTUATOR ON THE SDR FDEA202304010537Controller · failedPDIS 997 21-30 0265 01APR23 TLH OPEN U CABIN ALTITUDE WARNING ALERT AT FL280 CABIN ALT AUTO 1 AN 2 FAILED COULD NOT GET CONTROL OF PRESSURIZATION . ***EMERGENCY DECLARED*** INFO 01APR23 04:12 MEM U ********************MOCC UPDATE**********SDR FDEA202303310538Stringer · damagedPUNCTURE DAMAGE TO FUSELAGE AFT OF LOWER AFT CARGO DOOR. DAMAGE IS LOCATED FROM APPX FS 1650R-1680R, BETWEEN STR 22-23R. REMOVED FASTENERS AS NEEDED REF B757 SRM 51-40-02. REFERENCE E.A. # F-5310-T0373827. REF : SRM 53-00-01-2R TABLE 206/REPAIR 28 REPSDR CALA2023040300960Deck Plate · corroded(SUPPORT TASK) MAIN CABIN DECK PLATE STA 1720 BL0 PREVIOUS REPAIR HAS EVIDENCE OF CORROSION. TRANSCRIBED FROM HAECO GSO NR 9280 454. REMOVED AND FAB. NEW DOUBLER AT STA 1720 BL0 IAW B757-200 SRM 53 -60-51-2R-2.SDR CALA2023040300959Panel · corroded(SUPPORT TASK) MAIN CABIN DECK PLATE STA 1720 LBL20 PREVIOUS REP AIR HAS EVIDENCE OF CORROSION. TRANSCRIBED FROM HAECO GSO NR 92 80455. REMOVED AND FAB. NEW DOUBLER AT STA 1720 LBL20 IAW B757-200 SRM 53-60-51-2R-2.SDR FDEA202303310528Transmission · failedPDIS 925 27-80 0632 31MAR23 MEM OPEN U ON A 25 MILE FINAL APPROACH ATC SLOWED US TO 190 KNOTS. AT 210 KNOTS WE SELECTED FLAPS 1 AND GOT A TRAILING EDGE FLAP DISAGREE EICAS AND TRAILING EDGE LIGHT. RAN QRH AND USED ALTERNATE FLAPS FOR AN UNEVESDR FDEA202303300526Windshield · damagedPDIS 795 56-10 6826 30MAR23 MEM OPEN U AT FL 390 AND 0.80M LEFT FRONT WINDOW SHATTERED. APPEARED TO BE SOME SORT OF STRIKE, MOST LIKELY A BIRD. REPLACED #1 WINDSHIELDSDR FDEA202303300525Strap · cracked#2 ENG I/B T/R L/E RADIAL STRAP IS CRACKED AT APPROX 8 0CLOCK POS. REMOVED AND REPLACED PER B757 AMM 78-31-20-8SDR FDEA202303290521Drag Fitting · unknownWHILE PERFORMING OPEN HOLE INSPECTION OF RH UPPER SKIN AND DRAG FITTING, FOUND HOLE #4 INDICATION AT APPROX 7 O'CLOCK (SKIN) AND 1 O'CLOCK (FITTING) FACING FWD. REFER TO TABLE 1 FOR DAMAGE DEPTH AND HOLE DIA. REPAIR COMPLIED WITH IAW EA # F-5730-T0373603 SDR FDEA202303290520Drag Fitting · unknownWHILE PERFORMING OPEN HOLE INSPECTION OF RH UPPER SKIN AND DRAG FITTING, FOUND HOLE #10 INDICATION AT APPROX. 3 O'CLOCK, FITTING FACING FWD. REFER TO TABLE 1 FOR DAMAGE DEPTH AND HOLE DIA. REPAIR COMPLIED WITH IAW EA # F-5730-T0373603 P1 ON HOLE #10, RH USDR FDEA202303290519Drag Fitting · unknownWHILE PERFORMING OPEN HOLE INSPECTION OF RH UPPER SKIN AND DRAG FITTING, FOUND HOLE #9 INDICATION AT APPROX. 8 O'CLOCK SKIN AND FITTING FACING FWD. REFER TO TABLE 1 FOR DAMAGE DEPTH AND HOLE DIA. REPAIR COMPLIED WITH IAW EA # F-5730-T0373603 P1 ON HOLE #9SDR FDEA202303290518Drag Fitting · unknownWHILE PERFORMING OPEN HOLE INSPECTION OF RH UPPER SKIN AND DRAG FITTING FOUND HOLE #5 INDICATION AT APPROX 6 O'CLOCK SKIN AND FITTING. FACING FWD REFER TO TABLE 1 FOR DAMAGE DEPTH AND HOLE DIA. REPAIR COMPLIED WITH IN EA # F-5730-T0373603 P1 ON HOLE #5, RSDR FDEA202303290517Unknown · unknownON DOWNWIND AT 210 KNOTS SELECTED FLAPS 1 AND GOT TRAILING EDGE FLAPS LIGHT & EICAS. RAN QRH, USED ALTERNATE FLAPS/SLATS & LANDED UNEVENTFULLY WITH FLAPS 20. EMERGENCY DECLARED. EMERGENCY DECLARED. ACCOMPLISHED FLAP/SLAT ELECTRONIC UNIT BITE PROCEDURES PSDR FDEA202303290516Door · dentedNEED TO PERFORM SRM REPAIR ON DOOR R1 DENT OUT OF LIMIT PERFORMED DOUBLER REPAIR ON DOOR 1R PER SRM 52-10-01, REPAIR 7, THIS REPAIR IS A CAT. B REPAIR MAJOR REPAIRSDR FDEA202303280515Floorboard · delaminatedZONE 220 FLOORBOARD 221BF DELAMINATED. FABRICATED ZONE 220 FLOORBOARD 221BF ON TRAVELER # T23/1667599 IAW DWG SRZ-25-005 REVISION R. MAJOR REPAIR
Back to Boeing 757-200 SERIES