Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009051101338Starter · faultyAPU FAILED TO START. FAULT LGT ILLUM AND EICAS MSG. APU FAULT DISPLAYED. FOUND STARTER DRAGGING DOWN BATTERY VOLT AND GETTING HOT. REPLACED STARTER, OPS CHECK GOOD.SDR UALA2009051101323Light · inoperativeK-LAV EEL LIGHT BAR IS INOP. REPLACED K-LAV LIGHT BAR, OPS CHECKS GOOD.SDR UALA2009051101321Shim · missingL4 DOOR EMERGENCY POWER BOTTLE LINKS MISSING SHIMS - WASHERS - BINDING TRIGGER LEVER. REPLACED HARDWARE.SDR UALA2009050801319Slide · unserviceableLOW BOTTLE PRESSURE. PERFORMED LEAK TEST. COULD NOT FIND A LEAK. DISCHARGED THE BOTTLE AND VALVE WILL BE FULLY DISASSEMBLED AND REWORKED.SDR UALA2009050801317Light · detachedEMERGENCY LIGHTS DETACHED AT FLOOR LEVEL NEAR ROW 31C. SECURED EMERGENCY LIGHT STRIP, OPS CHECKS NORMAL.SDR UALA2009050701314Radome · damagedLIGHTNING STRIKE ON T/O, BIG BANG AND SMOKE ODOR IN COCKPIT. NEED TO INSTALL NEW BASE PLATE AND STATIC WICK ON LT SIDE VERY TOP OF RUDDER, BOTH MISSING DUE TO LIGHTNING STRIKE. INSTALLED DISCHARGE BASE AND PAINTED. STATIC WICK ON AOG Z4071. REPLACED STATICSDR UALA2009050701310Probe · faultyF/O PITOT STATIC HEAT INOP. REPLACED RELAYS K310, K103 09 AND K178, NO HELP. PROBE REMOVED FOR REPLACEMENT. F/O'S PITOT PROBE NEEDS TO BE RESEALED DUE TO PROBE REPLACEMENT. SEALED F/O PITOT PROBE. NEED TO PERFORM CHECK OF PROBE TO COMPLETE F/O'S PROBE REPSDR UALA2009050701315O-Ring · defectiveBOTTLE LOW, BELOW GREEN BAND. BOTTLE LEAKS AROUND BALL STEM O-RING. REMOVED & REPLACED O-RINGS.SDR UALA2009050701311Skin · dentedSEVERAL SKIN DENTS STA 600 AND STR 14L- 19L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR UALA2009050501294Actuator · faultyFUELER UNABLE TO FUEL CTR TANK. FOUND LT CTR TANK FUELING ACTUATOR SHOWING OPEN BUT NOT OPEN. REPLACED ACTUATOR. BOTH FUELING VALVE OPERATE NORMAL.SDR UALA2009050401281Bushing · wornNR 1 ENGINE OIL TANK FWD MOUNT BEARINGS WEDGE FAILED WITH BEARING MIGRATION FWD INTO SUPPORT LUG BUSHING MIGRATION IS ABOUT .100 EVIDENCE OF WEAR IN BUSHING. REMOVED ENG OIL TANK ASSY. REPLACED BUSHINGS. OIL TANK WAS HUNG AND IS IN PLACE.SDR UALA2009050401279Feeder Cable · burnedAPU GENERATOR FEEDER CABLE SEVERELY BURNED. REPLACED TERMINAL END ON APU GEN FEEDER. OPS CHK'D GOOD.SDR UALA2009050401277Sensor · malfunctionedE/E COMPT DOOR INDICATION LIGHT, RTFL. FOUND CLEARANCE OF SENSOR S10086 AND TARGET >.50 INCH, ADJUSTED PER MM. ALSO FOUND PLUNGER MISALIGNED. ALIGNED PLUNGER. OPS CK'D OKAY.SDR UALA2009050401272Chiller · malfunctionedDEBRIEFED CREW, FIRST OFFICER AND FLIGHT ATTENDANT SAID THEY DETECTED WHAT SEEMED LIKE BURNING INSULATION IN THE FWD GALLEY AREA. FLIGHT ATTENDANT SAID THAT THE ODOR WAS SO STRONG THAT SHE HAD PULLED ALL OF THE C/B'S IN THE FWD GALLEY AND THE ODOR STARTED TO SDR UALA2009050401271Wire · misinstalledCREW REPORTS ODOR IN FLT DECK ON TAXI OUT. FOUND PIN 6 AND PIN 9 (6:DC GROUND, 9: CASE GROUND) HAVE BEEN SWITCHED. NO OTHER DAMAGE NOTED. AIR FILTER WAS NOT RECEIVED WITH UNIT. REPLACED CHILLER.SDR UALA2009050101269Starter · faultyAPU WILL NOT START. APU CHECK SHOWS BAD STARTER. REPLACED STARTER, NO HELP, NO START. APU BATTERY DROPS TO 12V ON START BUT NO RPM. TRIED TO SPIN TURBINE FROM EXHAUST WOULD ONLY MOVE AN INCH BACK AND FORTH, LOCKED UP. PULLED CHIP DETECTORS PER SAMC FOUND SDR UALA2009043001261Pan · damagedNR 1 PYLON LOWER PAN DAMAGE, OUT OF LIMITS. ACCMP'D RE-CHECK INSPECTION OF DENT ON THE BOTTOM OF NR 1 ENGINE PYLON. CHECKED OK TO FOR SERVICE.SDR UALA2009042901247Pcu · faultyELEVATOR PITCH CONTROL HAS ABOUT ONE HALF INCH PLAY AND ALSO PULSATES WHEN YOU PULL BACK ON THE STICK. SUSPECT ELEV PCA, FOUND THE RT CENTER ELEVATOR PCU AT FAULT. PCU PLANESIDE WORKING REPLACEMENT. BITE TEST REPORTED RT ELEVATOR PCU FAULT MAINTENANCE AND SSDR UALA2009042901234Transceiver · underserviced3 WX FAIL DISPLAYED ON HSI(S). WXR TEST INOP (1=CAPT, 2=F-O, 3= BOTH) CREW COMMENTS: CYC C-B F2 NO HELP. OCCURRED ON CLIMB-OUT. TESTED OK ON GROUND. SUPPLEMENTAL DATA UPDATE, FOUND TRANSCEIVER FAN SCREEN CLOGGED, CLEANED SAME. REPLACED TR UNIT PRECAUTIONASDR UALA2009042901233Bottle · faultyFOUND DOOR ASSIST BOTTLE FOR DOOR 1R LOW. REPLACED DOOR 1R ASSIST BOTTLE.SDR UALA2009042801223Light · inoperativeDOOR NR 2 LEFT EMERGENCY EXTERIOR SLIDE LIGHT IS INOP. RELAMPED EMERGENCY LIGHT, CHECKS GOOD.SDR UALA2009042701212Cover · unsecureEMERGENCY EXIT LIGHT ON FLOOR DISLODGED FROM FLOOR. SECURED COVER.SDR UALA2009042701209Radar · inoperativeWEATHER RADAR INOP. FLIGHT DIVERTED. REPLACED THE WEATHER CONTROL PANEL. SYSTEM CHECKS NORMAL.SDR UALA2009042701206Light · inoperativeRIGHT FWD OVERWING EXIT EMERGENCY PATH LIGHT INOP. REPLACED LAMP, OPS GOOD.SDR UALA2009042701204Wire · damagedRIGHT WING L/E, OUTBOARD OF NR 2 ENG PYLON WIRE DAMAGED. REPLACED WIRE W4026-4501 PER BSPMS 20-10-13, 20-35-19, 20-10-15, AND CHECKED GOOD.SDR UALA2009042701203Attach Bracket · brokenDOOR L1 SLIDE LWR ATTACH BRACKET IS BROKEN. INSTALLED NEW ATTACH BRACKET.SDR UALA2009042401193Mount · shearedNR 1 ENG LOWER ISOLATION PACK BOLT SHEARED OFF AND LAYING ON UNISON RING. TRIED TO REMOVE SHEARED BOLT FROM MOUNT UNABLE TO ACP. SHIM PACK AND SHEARED BOLT HEAD PACKAGED AND ON FLIGHT DECK. REPLACED NR 1 ENG LOWER FWD ENG MOUNT. ACP'D INSP OF FWD ENG MOUNTSDR UALA2009042301185Light · unsecureEMERGENCY PATHWAY FLOOR LIGHTING PULLED OUT OF FLOOR. SECURED EEL LIGHTS. TEMP REPAIR TO PROTECTIVE CLEAR STRIP WITH TAPE. EEL LIGHT CHECKS GOOD.SDR UALA2009042301177Strip · unsecureEEL STRIP COMING UP ROWS 9 TO 11. SECURED STRIP.SDR UALA2009042201175Antenna · damagedLIGHTNING STRIKES TO RT FUSELAGE. FLIGHT DIVERTED. ACCOMPLISHED LIGHTNING STRIKE INSPECTION. VHF ANTENNA ABOVE MAIN ENTRY DOOR NR 2 HAS DAMAGE DUE TO STATIC DISCHARGE. REPLACED AND TESTS OKAY. FOUND DAMAGE ON RIGHT SIDE OF AC STA 658 BETWEEN STR 24-25, STSDR UALA2009042101165Window · crackedPAX WINDOW CRACKED. FLIGHT DIVERTED. REPLACED 13A WINDOW.SDR UALA2009042101161Battery Pack · dischargedRIGHT AFT OVERWING EMERGENCY LIGHT INOP. REPLACED BATTERY PACK AT M10568 AND OPS CHECK GOOD.SDR UALA2009042001155Idg · faultyEICAS MSGS R GEN DRIVE LIGHT DID NOT ILLUM WITH ENG SHUTDOWN. REPLACED IDG. RAN ENG, OPS CHECK OK.SDR UALA2009042001153Cooling Fan · failedODOR IN COCKPIT AND CABIN FL370 OBH FOLLOWED BY EQUIP OVRHT EICAS AND OVHT ON EQUIP COOLING SW. FOUND PRIMARY E&E COOLING FAN FAILED, SMELLED BAD AND BEARING FAILED. NO DEBRIS IN DUCTING. REMOVED & REPLACED PRIMARY E&E COOLING FAN. OPS CHECK NORMAL. NO SMSDR UALA2009042001152Wire Harness · damagedEICAS MSG FLT DECK TEMP. FOUND WIRE BUNDLE GOING TO FLT DECK TRIM AIR VALVE CONNECTORS D4654 AND D2546 DAMAGED AND BURNT. CONNECTOR D4654 OK, WIRING REPAIRED. CONNECTOR D2546 HAS 2EA-20 GAUGE WIRES INSTALLED, WAITING FOR NEW 24 GAUGE WIRE TO COMPLETE RPR. SDR UALA2009042001150Start Valve · faultyNO ENG STARTER EICAS MESSAGE. RETURNING TO GATE. RIGHT ENG, LEFT ENGINE START NORMAL. REPLACED START VALVE. OPS GOOD.SDR UALA2009042001145Actuator · faultyEXCESSIVE RUDDER TRIM. VERY SLOW TO EXTEND. CREW REPORTED FELT MORE LIKE A SPOILER FLOAT, NOT AN ENGINE VIBRATION. THE NR 2 FLT SPOILER WAS FOUND TO BE LAGGING IN OPERATIONAL TIME IN COMPARISON TO THE REMAINING FLT SPOILERS AND THE NR 10 FLT SPOILER WAS FOUSDR UALA2009042001151Actuator · faultyLT ENG SEC CONT STATUS MESSAGE ILLUMINATED ON DESCENT. REPLACED STATOR VANE ACTUATOR. OPS CHECKS OKAY.SDR UALA2009042101158Unknown · odorBURNING ODOR IN COCKPIT LINGERING AFTER PACKS TURNED ON. ODOR FROM LT PACK ONLY. ODOR DISSIPATED AFTER 20 MINUTES GROUND OPS. NO HISTORY. NO FURTHER INCIDENTS NOTED.SDR UALA2009042001135Compressor · stalledNR 1 ENGINE COMPRESSOR STALL ON ENGINE RUNUP, ENGINE SHUT DOWN, PER CREW. SAMC FLETCH PROG TEXT: - ITEM ROLLED FORWARD. SAMC TEXT: COMPRESSOR STALL AT APPROX 40 PERCENT, SHUTDOWN, PER CREW. INSPECTED ENGINE UNISON RINGS, CHIP DETECTORS AND BOROSCOPED FOR SDR UALA2009042001125Girt Bar · obstructedDOOR 3L WILL NOT ARM. REMOVED TRASH FROM GIRT BAR.SDR UALA2009041701115Skin · damagedAIRCRAFT DAMAGED BY BELT LOADER ON FUSELAGE FWD OF AFT CARGO DOOR NEAR BOTTOM OF DOOR CUTOUT. DAMAGED AREA IS APPROX A LONG GOUGE 5\ LEADING UP TO A SERIES OF SMALL GOUGES. CENTER OF DAMAGED AREA ONE EIGHT INCH DEEP AND GOUGE ACROSS ONE RIVET. COMPLIED WITHSDR UALA2009041701113Light · unsecureEXIT PATH LIGHTING ON FLOOR BETWEEN ROW 9 & 15 LOOSE. SECURED EEL.SDR UALA2009041601096Light · inoperativeEXTERIOR SLIDE LIGHT AT DOOR 1LT INOP. RELAMPED EXTERIOR LIGHT.SDR UALA2009041501083Unknown · odorELECTRICAL ODOR NOTED. FLIGHT DIVERTED. INSPECTED AIRCRAFT AND NO DISCREPANCIES FOUND.SDR UALA2009041301062Pump · faultyCREW REPORT: CENTER ELECT 2 PUMP PRESS LIGHT ILLUMINATED. REPLACED PUMP ASSY AND PRESSURE AND CASE DRAIN FILTERS. LEAK AND OPS CHECK OKAY.SDR UALA2009041301056Carbon Seal · leakingNR 2 ENG HIGH OIL CONSUMPTION. REPLACED NR 2 ENG DE-OILER CARBON SEAL. ACP 5 MIN IDLE RUN, NO LEAKS NOTED.SDR UALA2009040901032Valve · failedIN CRUISE FL400 L BLEED PRESS FLUCTUATED DOWN 2 AROUND 24 PSI. THEN WENT DOWN AND STAYED AT 24 PSI MAINT TEXT: PER VERBAL FROM INBOARD CREW LT 24 PSI RT 42 PSI REMAINDER OF CRUISE FLT. REPLACED VALVE AND CONTROL PER MM 36-11-07 AND MM 36-11-08. ACCOMPLISHEDSDR UALA2009040801020Slide · unserviceableLOW BOTTLE PRESSURE. NO LEAK FOUND WITH SPRAY BOTTLE LEAK TEST OR WITH WATER BATH TEST. VALVE WILL GET COMPLETE OVERHAUL.SDR UALA2009040801019Structure · leakingFUEL LEAKING FROM NR 1 ENGINE PYLON SKATE SUPPORT AREA. FUEL LEAKING IN THE ENCLOSED AREA OF PYLON ABOVE THE AFT SUPPORT STRUT. APPEARS TO BE COMING FROM FASTENERS THRU THE STRUT SUPPORT STRUCTURE INTO THE WING. LOCATED LEAK. SEALED WITH A1-2 AND B1-2 AT 1
Back to Boeing 757-222