Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013042402853Light · wrong partFOUND EMERGENCY LIGHT IN FRONT OF FWD FA CLOSET WITH ORANGE STRIP COVERING. SHOULD BE WHITE. REMOVED ORANGE COVERING. CHECKED GOOD.SDR UALA2013042402852Light · inoperativeEMERGENCY LIGHT SEGMENT INOPERATIVE AT SEAT 31 ABC. REPLACED LIGHT AT ROW 31 ABC PER MM 33-51-00.SDR UALA2013042402851Light · obstructedCARPET COVERS PART OF EMERGENCY LIGHT ADJACENT AFT LAVATORY K. REMOVED CARPET COVERING EMERGENCY LIGHT.SDR UALA2013042402849Light · inoperativeEMERGENCY LIGHT SEGMENT IS INOPERATIVE AT SEAT 27ABC. REPLACED LIGHT.SDR UALA2013042402843Light · inoperativeFOUND AISLE LIGHTING FROM ROW 23ABC TO 25 ABC INOPERATIVE. REMOVED & REPLACED AISLE LIGHT IAW AMM. OPS CHECKED GOOD.SDR UALA2013042502884Wire · damagedWARNING ELEX STATUS MESSAGE WITH IRU'S ALIGNED. REPAIRED WIRES TO RIGHT STALL WARNING STICK SHAKER, AND TESTED OKAY.SDR UALA2013042502883Unknown · unknownREPLACE LEFT EICAS COMPUTER FOR DF979. REPLACED LEFT EICAS COMPUTER MM, NO HELP. STILL HAS UPPER EICAS CRT LEFT SIDE ERRATIC DISPLAY, OK IN RIGHT POSITION.SDR UALA2013042502886Fseu · no testNR 3 FLAP/SLAT ELECTRICAL UNIT BITE TEST FAILED. REPLACED NR 3 FSEU.SDR UALA2013042402855Light · inoperativeEEL OUTSIDE OF MID LAV INOP. MID LAV EEL STRIP INOPERATIVE.SDR UALA2013042402850Carpet · defectiveREF FCD 2527-01070 STEP 3.0 FLOOR EEL PATH LIGHTING CARPET COVER PART OF LIGHTING, ADJACENT TO MID LAV (LAV S). REMOVED CARPET COVERS EEL PATH LIGHTING. INSPECTED LIGHT. CARPET WAS REMOVED AWAY FROM LIGHT SECTION.SDR UALA2013042202757Wire · burnedFOUND BURNT WIRES IN BUNDLE GOING TO THE P33 C RELAY PANEL. REPLACED DAMAGED WIRES. BURNT WIRES WERE REPAIRED IN P33 AND PROX ELECTRONIC BOX WERE REPLACED. OPS CHK OKAY.SDR UALA2013042302834Light · damagedEMERGENCY LIGHT ASSY IN FRONT OF LAVATORY INOPERATIVE. FOUND LIGHT ASSY LEADS DAMAGED. LIGHT ASSY 30 INCH LONG. REPLACED LIGHT ASSY, GROUND CHECKED NORMAL.SDR UALA2013042302830Floor Panel · damagedAFT PIT FLOOR HAS A HOLE AT STA 1480 DIA 1 X1 AND A HOLE AT STA 1500 DIA 2X2. REPAIRED HOLES IAW SRM 53-00-53, PG 103-104, FIG 101.SDR UALA2013042302833Cap · missingTHE TERMINATING ENDCAPS ARE MISSING ON THE ESCAPE PATH FLOOR LIGHTING AT SEATS 1, 6, 8 AND 40. REPLACED FOUR EMERGENCY LIGHT END CAPS.SDR UALA2013042302829Fuse · leakingAFTER LANDING HAD LOSS OF HYDRAULIC FLUID IN RIGHT SYSTEM. REPLACED NORMAL ANTISKID MODULE HYDRAULIC FUSE IN LEFT WHEEL WELL, BOTTOM FUSE. BRAKES OPS NORMAL, NO LEAKS NOTED.SDR UALA2013042402842Light · inoperativeLAVATORY LIGHTS INOP AT DOOR-1L FWD-CAB LAV. LIGHT INOP IN FWD LAV. RELAMPED INCANDESCENT. CHECKS OK.SDR UALA2013042302810Skin · dentedEXTERNAL FUSELAGE SKIN HAD SEVERAL DENTS BS 600-640 S14-19L. FOUND OUT OF LIMITS. REPAIRED IAW REO EVA G-09691, REV A IAW EVA 40072.SDR UALA2013042302809Skin · dentedLEFT FUSELAGE SKIN HAS A DENT 1INCH WIDE BY 0.029 INCH DEEP AT BS 600, S17L. DENT IS WITHIN LIMITS PER SRM 53-00-01. EDDY CURRENT INSPECTION REVEALED NO CRACKS. AREA REPAIRED PER ECRA 53 30-014531 ORIG,SDR UALA2013042202756Cap · missingEMERGENCY ESCAPE LIGHTING STRIP END CAP MISSING 40C. INSTALLED NEW END CAP.SDR UALA2013042302801Carpet · defectiveMID LAV EEL LIGHT HAS CARPET OBSTRUCTING EEL LIGHT. TRIMMED CARPET SO EEL LIGHT IS FULLY VISIBLE. OP CHECKED GOOD.SDR UALA2013042202785Switch · failedTOP EFIS DISPLAY INOPERATIVE IN AUTO POSITION, VERIFIED EICAS UPPER DISPLAY INOPERATIVE IN AUTO. REPLACED EICAS DISPLAY SWITCH, RELOAD SOFTWARE OPS AND OPC ON LEFT EICAS PER MM, GROUND OPS CHECKED OK.SDR UALA2013042202789Light · dimEMERGENCY LIGHT INTENSITY LOW, ADJACENT TO SEAT ROW 23. REPLACED EMERGENCY LIGHT. OPS CHECKED GOOD.SDR UALA2013042202788Cap · missingEMERGENCY LIGHT COVER END CAP IS MISSING, ADJACENT TO SEAT ROW 8. REPLACED END CAP. INSPECTED INSTALLATION.SDR UALA2013042202786Light · inoperativeEMERGENCY LIGHT INOPERATIVE ADJACENT TO SEAT ROW 34. REPLACED EMERGENCY LIGHT. OP CHECKED GOOD.SDR UALA2013042302800Light · missingREF FCD 2527-01070, DID NOT LOCATE EEL LIGHT ADJACENT TO MID LAV (LAV S). INSTALLED EEL LIGHT ASSY ADJACENT TO MID LAV (LAV S), OPS CHECK NORMAL. REF EEL DWG 15F6889 AND AMM.SDR UALA2013042202783Light · missingREF FCD 2527-01070, DID NOT LOCATE EEL LIGHT ADJACENT TO FWD CLOSET. INSTALLED EEL LIGHT ASSY ADJACENT TO FWD CLOSET. OPS CHECK NORMAL. REF EEL DWG 15F6889 & AMM 33-51-96.SDR UALA2013042202772Filter · cloggedRECIRCULATION FAN PRODUCED ODOR IN AIRCRAFT. STOPS WITH RIGHT RECIRCULATION FAN OFF. REPLACED BOTH RECIRCULATION FILTERS, FOUND RT FILTER PLUGGED. OPS CHECKED NORMAL. RAN BOTH ENGINES, CHECKED OKAY.SDR UALA2013042202761Skin · damagedCREASE AT FUSELAGE BS 1700 S17L. REPAIRED AREA IAW SRM 53-00-01 FIG 201 REPAIR 3. NDT INSPECTED AREA BEFORE REPAIR WAS INSTALL IAW NDT MANUAL 51-00-19 AND 51-00-16 AND NO DEFECTS NOTED.SDR UALA2013042202755Sliding Window · delaminatedF/O FWD SIDE WINDOW DELAMINATED TOP AND SIDE. REPLACED F/O SLIDING WINDOW.SDR UALA2013042202784Structure · tornON ARRIVAL AT GATE, FOUND LEFT INBOARD SLAT TRAILING EDGE RIPPED OPEN AND DELAMINATED. REPLACED NR 5 SLAT PER AMM.SDR UALA2013042202765Channel · corrodedHAT CHANNEL AT RBL 34 BS 336 HAS CORROSION ON UPPER SURFACE. FABRICATED AND INSTALLED NEW HAT CHANNEL IAW SRM. MAJOR REPAIR.SDR UALA2013042202763Stiffener · damagedLEFT WING PNEUMATIC DUCT, I/B DUCT CLAMP BRACKET LOCATED BEHIND NR 5 SLAT I/B AUX TRACK, WEARING INTO VERTICAL STIFFENER ON FRONT SPAR. REMOVED AND REPLACED DAMAGED FRONT SPAR STIFFENER IAW SRM 51-40-02 AND DWG 112N2002.SDR UALA2013042202758Light · inoperativeEMERGENCY EXIT SIGNS INOPERATIVE 1L 1R, 1A BULL NOSE. EMERGENCY LIGHT AT 2C ALSO INOPERATIVE. SYMPTOMS CHANGE WITH DIFFERENT CHARGERS REPLACED. REPLACED M731 CHARGER RELAMPED 1A AND L1 DOOR ALL LIGHT BULBS FOR EXITING AND REPLACED LAMPS 2A, OPS CHECKED OSDR UALA2013042302803Light · inoperativeEEL EXIT SIGN MARKERS INOP 1L 1R, 1A BULL NOSE. REPLACED M731 CHARGER RELAMPED 1A AND DOOR 1 LEFT ALL LIGHT BULBS FOR EXIT SIGN AND RELAMPED 2A, OPS CHECK OK. VERIFIED PER IDT.SDR UALA2013042302802Light · inoperativeEEL AT AFT LAV IS INOP. REPLACED EEL STRIP, OPS NORMAL.SDR UALA2013041902712Control Unit · failedLEFT ELEV PCU EICAS WON'T CLEAR. HARD FAULT ELEVATOR PCU. FOUND OUTBOARD PCA AT FAULT. REMOVED AND REPLACED LT OB ELEVATOR.SDR UALA2013041902711Hinge · lack of lubeL2 DOOR DOOR HINGE IS NOT CLOSING. LUBED HINGE, OPS NORMAL.SDR UALA2013041802647Angle · corrodedFWD CARGO DOOR CUTOUT LOWER ANGLE CORRODED AT BS 615. REPAIRED FWD CARGO DOOR CUTOUT IAW ECRA 5330-0415 CATEGORY 'A' REPAIR IAW SRM 51-00-06, OPS CHECKED GOOD. MAJOR REPAIR.SDR UALA2013041802682Smoke Detector · malfunctionedEQUIPMENT COOLING SMOKE DETECTOR MALFUNCTIONED. SMOKE DETECTOR REPLACED.SDR UALA2013041802680Skin · dentedFUSELAGE SKIN DENTED AT BS 1620 BELOW S18R. AT C CHECK DENT WAS FOUND TO BE OUT OF LIMITS AND A REPAIR DOUBLER WAS INSTALLED IAW ECRA 5330-045 12.SDR UALA2013041902703Skin · dentedFUSELAGE DENT AT FRAME 780 ABOVE STRINGER 19L APPEARS WITHIN 3" OF SKIN SPLICE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR PER ECRA 5330-04521 AT BS 778 BETWEEN STR 16L-18L.SDR UALA2013041802648Skin · damagedDOUBLER REPAIR TO BS 778 FUSELAGE SKIN BETWEEN STR 16LT-18LT RECEIVED FAA FORM 8100-9 DATED 4-16-13 THAT CONTAINS STAGE 1&2 APPROVAL. (CF0744) MAJOR REPAIR ACCOMPLISHED.SDR UALA2013041802661Unknown · unknownFLT DECK WARMER THAN SELECTED WITH SWITCH ON & TEMP CONTROL IN AUTO. INOPERATIVE LIGHT EXISTING. 82' WITH FLT DECK CONTROLLER IN FULL COLD. PERFORMED FILTER AND SENSOR CLEANING. TEMP CONTROLLER LISTS NO FAULTS. BITE CHECKED GOOD. OPERATED LEFT PACK INSDR UALA2013041802664Girt Bar · out of adjustL1 DOOR UNABLE TO DISARM AND COULD NOT REMOVE BUSSEL. L1 SLIDE ARMED AND NOT PINNED. ACCOMPLISHED REMOVAL OF DOOR 1L SLIDE BUSSEL. REMOVED L1 DOOR SLIDE COVER. LUBRICATED PIN. OPERATED SMOOTHLY. CHECKED AND ADJUSTED DOOR, OPS CHECKED NORMAL. FEELS LIKE SDR UALA2013041802681Light · missingEMERGENCY LIGHT STRIP MISSING. REPLACED EMERGENCY LIGHT ASSY. OPS CHECKED GOOD.SDR UALA2013041802671Smoke Detector · inoperativeAFT LAVATORY SMOKE DETECTOR INOPERATIVE. REPLACED AFT SMOKE DETECTOR, OP CHECKED GOOD.SDR UALA2013041802646Web · damagedBS 324 WEB HAS ELONGATED HOLES FROM RBL 30 - 62. REPLACED WEB AND ANGLES, AND REPAIRED FRAME IAW ECRA 5310-05720 AND REO-G16061 REV H. ACCOMNPLISHED HFEC IAW NTM PRT 6, 51-00-19, NO DEFECTS NOTED. MAJOR REPAIR.SDR UALA2013041802676Cap · missingEMERGENCY LIGHTS IN FIRST CLASS CABIN MISSING END CAPS. INSTALLED END CAPS.SDR UALA2013041802674Cover · looseFLOOR EEL STRIP CLEAR COVER IS LOOSE FROM ROW 30-35. SECURED EEL STRIP COVER.SDR UALA2013041802673Lens · unsecureEXIT ROW LIGHT LOOSE AT RIGHT SIDE OVERWING. SECURED LENSE. ACCOMPLISHED INSPECTION OF LENSE ASSY SECURITY. FOUND IN AIRWORTHY CONDITION.
Back to Boeing 757-222