Boeing 757-223
Service difficulty reports · 8,750
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA971773Wire · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY FORWARD GALLEY FOUND INOPERATIVE. REPAIRED BROKEN EMERGENCY FLOOR LIGHT WIRE BY FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)SDR AALA971572Connector · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY FORWARD GALLEY INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT CONNECTOR BY FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971445Connector · brokenSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS FROM FIRST CLASS CABIN TO FORWARD GALLEY INOPERATIVE. REPLACED TWO BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTORS AT FORWARD PART OF FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971434Light · defectiveDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY FLOOR LIGHTS AT FORWARD PART OF MAIN CABIN INOPERATIVE.SDR AALA971432Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT MARKERS AT 1R DOOR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT MARKERS AT 1R DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971395Light · defectiveMIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN FIRST CLASS CABIN INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIPS IN FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971252Wire · brokenDFW - DURING OVERNIGHT CHECK, L1 AND R1 FORWARD EMERGENCY EXIT DOOR LIGHT SIGN INOPERATIVE. REPAIRED BROKEN/SHORTED WIRE TO L1 AND R1 FORWARD EMERGENCY EXIT DOOR LIGHT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971120Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS FROM FRONT OF FIRST CLASS CABIN TO PAX SEAT ROW 16 INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR AT FRONT OF FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA971023Floorbeam · corrodedAFW - FLOORBEAM AT STATION 310 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1178. (M)SDR AALA971022Floorbeam · corrodedAFW - FLOORBEAM AT STATION 1640 HAD CORROSION BLENDED BEYOND AARD LIMITS. REPAIR PER MRB 757-1179. (M)SDR AALA971021Floorbeam · corrodedAFW - FLOORBEAM AT STATION 324 HAS CORROSIO REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1180. (M)SDR AALA971020Sill · corrodedAFW - FOUND LOWER MAIN SILL UPPER CHORD HAS CORROSION REMOVAL. MATERIAL REMAINING IS BEYOND SRM ALLOWANCES. REPAIR PER MRB 757-1187. (M)SDR AALA971019Support · corrodedAFW - FOUND FLOOR SUPPORT CORRODED AT BS 333. REPAIR PER MRB 757-1186. (M)SDR AALA971018Frame · damagedAFW - BELLFRAME AT RBL 26.5 STATION 1480 HAS WEAR MARK. REPAIR PER MRB 757-1185. (M)SDR AALA971017Support · corrodedAFW - FOUND FLOOR SUPPORT CORRODED AT BS 404-407. REPAIR PER MRB 757-1183. (M)SDR AALA971016Floorbeam · corrodedAFW - FLOORBEAM AT STATION 365 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERILA REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-1182. (M)SDR AALA971015Floorbeam · corrodedAFW - FOUND FLOORBEAM AT STATION 377 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1181. (M)SDR AALA970990Sign · defectiveDFW - DURING OVERNIGHT CHECK, RIGHT AFT OVERWING DOOR EMERGENCY EXIT SIGN FOUND INOPERATIVE. REPLACED AFT MODULE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA970974Connector · brokenMIA - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHTS AT PASSENGER SEATS 9D THROUGH 17D FOUND INOPERATIVE. REPAIRED BROKEN EMERGENCY EXIT LIGHT CONNECTOR AT PASSENGER SEAT 9D. SYSTEM GROUND CHECK, NORMAL OPERATION. (X)SDR AALA970966Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT FIRST CLASS GALLEY FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIP AT FIRST CLASS GALLEY. SYSTEM FOUND CHECKED, NORMAL OPERATION. (X)SDR AALA970924Connector · looseMIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS FROM ROW 1 TO ROW 14 FOUND INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTORS AT ROW 1. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA970918Connector · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT AFT SECTION OF MAIN CABIN FOUND INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTOR AT AFT SECTION OF MAIN CABIN. SYSTEM GROUND CHECK, NORMAL OPERATION. (X0SDR AALA970950Floorbeam · corrodedAFW - FLOORBEAM AT STATION 1640 HAD CORROSION BLENDED BEYOND SRM LIMITS, E58 NR'S 1699029, 1699030, 1699032. REPAIRED PER MRB NR 757-1172. (M)SDR AALA970953Floorbeam · corrodedAFW - FLOORBEAM AT STATION 324 HAS CORROSION REMOVAL ON SURFACE, MATERIAL REMAINING IS BEYOND SRM LIMITS REF E58 NR 1698996. REPAIRED PER MRB NR 757-1173. (M)SDR AALA970952Floorbeam · corrodedAFW - FLOORBEAM AT STATION 365 HAS CORROSION REMOVAL ON UPPER SURFACE, MATERIAL REMAINING BEYOND SRM LIMITS REF E58 NR 1699007. REPAIRED PER MRB NR 757-1170. (M)SDR AALA970951Support · corrodedAFW - FLOOR SUPPORT STRUCTURE IN SEC 41 HAS CORROSION REMOVAL, MATERIAL REMAINING BEYOND SRM LIMITS REF E52 NR 1698994 AND 1698995. REPAIRED PER MRB NR 757-1171. (M)SDR AALA970910Fuel Governor · defectiveMCO - FLT 638 - DURING APPROACH TO MCO, LEFT ENGINE FLAMEOUT 500 FEET BEFORE LANDING. ACCOMPLISHED ABNORMAL PROCEDURES AND AIRCRAFT LANDED WITHOUT INCIDENT. REPLACED LEFT ENGINE FUEL FLOW GOVERNOR, TRANSIENT PRESSURE UNIT, BLEED VALVE CONTROL UNIT, IP BLEED SDR AALA970900Pan · gougedAFW - L-1 DOOR PAN HAS TWO SMALL GOUGES. REF MRB 757-1167 REFINISH THE BLENDED OUT AREAS PER REF C SRM SECTION CONTINUE IN SERVICE. (M)SDR AALA970899Floorbeam · corrodedAFW - CABIN FLOORBEAM AT STATION 1640 CORRODED AT UPPER CHORD. BLENDED, ALODINED, FABRICATED REPAIR STRAP, PRIMED, FILLED BLENDED AREAS. INSTALLED REPAIR STRAP WET WITH HI-LOK. (M)SDR AALA970870Floor Beam · corrodedAFW - FLOOR BEAM AT STA 1640 HAS SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS. REF E 58 NR'S 1697035, 1697033, 1697032, 1697036, AND 1697034. TST: 15,561.43 HOURS. CYCLES: 5,712. (X)SDR AALA970878Rib · corrodedAFW - AILERON ATTACH RIB NR 1 HAS CORROSION REMOVAL AROUND GROUNDING ATTACH BOLT HOLE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REF: E 58 NR 1697121. TST: 15,516.36 HOURS. CYCLES: 5,712. (X)SDR AALA970873Seat Track · corrodedAFW - SEAT TRACK AT STA 377, LBL 45, HAS CORROSION REMOVAL MATERIAL REMAINING BEYOND SRMS LIMITS. REF E 58 NR 1697043. TST: 15,516.36 HOURS. CYCLES: 5,712. (X)SDR AALA970872Angle · corrodedAFW - ANGLE BY L-1 DOOR OPENING HAS CORROSION REMOVAL MATERIAL REMAINING AND IS BEYOND SRM LIMITS. REF E 58 NR 1697136. TST: 15,516.36 HOURS. CYCLES: 5,712. (X)SDR AALA970869Deck Plate · corrodedAFW - DECK PLATE HAD CORROSION BLENDED BEYOND SRM LIMITS. REF E 58 NR'S 9037033 AND 9037052. (X)SDR AALA970877Pan · gougedAFW - R1 DOOR PAN HAS GOUGE THAT IS BEYOND SRM LIMITS. REF E 58 NR 1696987. TST: 15,516.43 HOURS. CYCLES: 5,712. (X)SDR AALA970876Floor Beam · corrodedAFW - FLOOR BEAM AT STA 365 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRMS LIMITS. REF E 58 NR 1697052. TST: 15,561.43 HOURS. CYCLES: 5,712. (X)SDR AALA970875Floor Beam · corrodedAFW - FLOOR BEAM AT STA 377 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REF E 58 NR'S 1697054 AND 1697062. TST: 15,561.43 HOURS. CYCLES: 5,712. (X)SDR AALA970874Floor Beam · corrodedAFW - FLOOR BEAM AT STA 324 HAS CORROSION REMOVAL ON UPPER SURFACE MATERIAL REMAINING IS BEYOND SRM LIMITS. REF E 58 NR'S 1697049 AND 1697047. TST: 15,561.43 HOURS. CYCLES: 5,712. (X)SDR AALA970871Structure · corrodedAFW - FLOOR SUPPORT STRUCTURE SEC 41 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING BEYOND SRM LIMITS REF E 58 NR'S 1697045, 1697051, 1697057, 1697058, 1697139. TST: 15,561.43 HOURS. CYCLES: 5,712. (X)SDR AALA970808Sill · corrodedAFW - FOUND UPPER CHORD HAS CORROSION REMOVAL ON HORIZONTAL FLANGES ON UPPER AND LOWER SURFACES. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-1147. (M)SDR AALA970803Floorbeam · corrodedAFW - FLOORBEAM AT STATION 310 RBL 42 HAD CORROSION BLENDED BEYOND SRM LIMITS, E58 NR 1692352. REPAIRED PER MRB, NR 7571136. (M)SDR AALA970801Floorbeam · corrodedAFW - FLOORBEAM AT STATION 324 RBL 44 AND RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1692354 AND 1692367. REPAIRED PER MRB NR 757-138. (M)SDR AALA970799Floorbeam · corrodedAFW - FLOORBEAM AT STATION 365 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS E58 NR 1692356 AND 1692544. REPAIRED PER MRB NR 757-1140. (M)SDR AALA970797Structure · corrodedAFW - FLOOR STRUCTURE AT STATION 403 RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1692360. REPAIRED PER MRB NR 757-1142. (M)SDR AALA970796Pan · gougedAFW - R1 DOOR PAN HAS SMALL GOUGE BLENDED BEYOND SRM LIMITS, E58 NR 1692306 NR 1. REPAIR PER MRB NR 757-1143. (M)SDR AALA970739Conductor · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN FIRST CLASS CABIN FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT FLAT CONDUCTOR IN FIRST CLASS CABIN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA970802Structure · corrodedAFW - FLOOR STRUTURE AT STATION 303 RBL 40 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1692351. REPAIRED PER MRB NR 757-1137. (M)SDR AALA970798Structure · corrodedAFW - FLOOR STRUCTURE AT STATION 365 RBL 23 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1692358. REPAIRED PER MRB NR 757-1141. (M)SDR AALA970804Floorbeam · corrodedAFW - FLOORBEAM AT 1640 HAS CORROSION REMOVAL ON UPPER SURFACE BEYOND SRM LIMITS E58 1692426 1692423 1692421. REPAIRED PER MRB NR 757-1135. (M)SDR AALA970800Structure · corrodedAFW - FLOOR STRUCTURE AT STATION 330 TO 332.5 RBL 3 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1692355. REPAIRED PER MRB NR 757-1139. (M)
Back to Boeing 757-223