Boeing 757-232
Service difficulty reports · 15,843
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2017122708989Ground Stud · looseCEILING PANEL EMERGENCY LIGHT INOPERATIVE, LT SEAT ROW 36 ABC. TROUBLESHOT, FOUND THE LT OVERHEAD ROW 36 EMERGENCY LIGHT GROUND STUD TO BE LOOSE, SECURED AND CHECKED GOOD IAW AMM 33-51 AND 33-51.SDR DALA2017122808988Sensor · malfunctionedLEFT AFT ENTRY DOOR LIGHT ILLUMINATED ON LANDING. REPLACED THE AFT LEFT DOOR WARNING SENSOR S10097 IAW MM 52-71, ALL CHECKED OK.SDR DALA2017122608937Proximity Sensor · failedINDICATOR LIGHT FOR SLIDE ABOVE R2 INOPERATIVE. R & R THE GIRT BAR FWD PROXIMIATY SENSOR AMM 25-66, AND WDM 25-66. OPS CHECKED GOOD.SDR DALA2017122608894Lens · missingEMERGENCY EXIT LIGHT LENS AT SEAT 26A MISSING. REPLACED THE LENS IAW AMM 33-51.SDR DALA2017122008764Door · corrodedLAVATORY G WASTE SERVICE PANEL DOOR IS CORRODED. REMOVED AND REPLACED THE DOOR IAW SRM 51-40-02.SDR DALA2017121808711Electrical Sys · inoperativeMOVING FIRST OFFICER CHAIR AFT, SPARKS SHOT OUT FROM BELOW CHAIR THEN ELECTRICAL FUNCTIONS BECAME INOPERATIVE. REPLACED THE FIRST OFFICER`S SEAT IAW AMM 25-11.SDR DALA2017121808681Light · detachedEMERGENCY LIGHT ON ISLE SIDE OF SEAT 19D IS DETATCHED. ATTACHED THE EMERGENCY LIGHT.SDR DALA2017122908990Proximity Sensor · malfunctionedLT WING SLIDE EICAS MSG INTERMITTENT IN FLIGHT. DISARMED LT AND RT OVERWING ESCAPE SYS IAW AMM 25-65. REMOVED THE LT OVERWING SLIDE IAW AMM 25-65(861834). REMOVED PANEL 195FL, R & R BUSHINGS ON FITTINGS AND HINGES. REPLACED THE PROXIMITY SENSOR FOR THE LT OVSDR DALA2017121408607Battery Pack · inoperative(AIRCRAFT 0655, L/P 3869017) DURING WAKE UP CHECK LEFT EMERGENCY LIGHTS ON FOR 2 MINUTES. RECHARGED EMERGENCY LIGHTS BATTERY PACKS IAW B757 AMM 33-51-11.SDR DALA2017121308604Lens · loose(AIRCRAFT 6700, L/P 0336261) EMERGENCY EXIT SIGN COVER LOOSE / LOCATIONS:604. RE-SECURED EMER EXIT SIGN COVER AS NECESSARY.SDR FDEA201712113359Frame · crackedMAIN CABIN LT FRAME WEB STA 1681, BELOW CUSP STR 17L CRACKED APPROX 2.5 INCHES LONG (HFEC VERIFIED). REMOVED DAMAGE, FABRICATED AND INSTALLED STA 1681 FRAME REPAIR IAW EA F-5310-T033786P1 FUSELAGE -MAINFRAME -STA 1681 FRAME CRACKED AT STRINGER S-17L.SDR DALA2017121208519Battery Pack · inoperative(AIRCRAFT 652, L/P 3944151) EMERGENCY LIGHT FROM ROW 16-19 RT INOP. R/R M736 BATTERY PACK PER B757 AMM 33-51.SDR DALA2017121208515Heat Exchanger · broken(AIRCRAFT 6700, L/P 3636166) L/H PACK PUTTING OUT HOT AIR IN AUTO. BURNING SMELL. DIRTY SOCK SMELL. OPERATING L/H PACK IN STBY MODE IS A LITTLE BETTER.FOUND BROKEN, L/H PACK BAY. REPLACED BROKEN L/H PACK HEAT EXCHANGER INLET DUCT PER B757 AMM 21-51.SDR DALA2017121508639Cover · missingSHIP 6713 R1 DOOR HANDLE COVER PLATE MISSING. CORRECTIVE ACTION: INSTALLED R1 DOOR HANDLE COVER PLATE PER B757 AMM 52-11. CHECKS GOOD. (3886436)SDR DALA2017120808495Door · frozen(AIRCRAFT 675, L/P 3562812) L3 DOOR WILL NOT DISARM. T/S, FOUND DOOR TO BE FROZEN, THAWED FLOOR AREA, DOOR OP'S / NORMAL.SDR DALA2017121108494Lens · broken(AIRCRAFT 6705, L/P 3308406) EXIT LIGHT AT 2L DOOR IS BROKEN. R & R EXIT LIGHT COVER AT L2 DOOR.SDR DALA2017120808496Girt Bar · dirty(AIRCRAFT 674, L/P 3676744) F/A REPORTS 2R DOOR "ARMED" LITE STILL ILLUMINATED WHEN IT SHOULD BE DISARMED. CLEARED DEBRIS FROM GIRT BAR BRACKET.SDR DALA2017120808493None · none(AIRCRAFT 684, L/P 0329050) EXISTING DOUBLERS INTERFERE WITH LUG DOUBLERS 5,6 BETWEEN FR 620 THRU 660 STR 2R. REFERENCE NR CARD 17 FOR CORRECTIVE ACTION REF SCEPTER LOG NBR 0329034.SDR DALA2017120808492None · none(AIRCRAFT 684, L/P 0329034) C/W PRI 563966-14. COMPLIED WITH PRI 563966-14 ( REV 2 ) A. RECEIVED FINAL ER/A 563966-14 REV A.SDR DALA2017120708500Light · inoperative(AIRCRAFT 6714, L/P 0327553) EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS:03C / SEAT MOUNTED EMERGENCY LIGHTS. RESEATED LIGHT AT 3C.SDR DALA2017120708499Light · damaged(AIRCRAFT 6714, L/P 0327552) EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS:02C / SEAT MOUNTED EMERGENCY LIGHTS. RESEATED LIGHT AT 2C.SDR DALA2017120708491Fuse · open(AIRCRAFT 697, L/P 3158337) EMER LIGHT IN BULL NOSE INOP AT ROW 23RT. REPLACED OPEN FUSE AT BATTERY PACK. OPERATIONAL TEST OK PER B757 AMM 33-51.SDR DALA2021030501273Retaining Clip · misalignedDURING THE ACCOMPLISHMENT OF THE 2KU INSTALLATION PER GOGO DWG D18470-22207 REV C, AND AMDS WORKCARD 2330-01349-01D, MAINTENANCE ENCOUNTERED AN EXISTING HOLE (0.159 DIA) AT FS 580 AND S1-2R FOR AN INSULATION BLANKET RETAINING CLIP THAT WILL FALL UNDERNEATH THSDR DALA2021030501272Retaining Clip · misalignedWHILE IN DTW FOR THE 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING D18470-22207 REV. C ) AT FS 660 BETWEEN S-2L AND S-3L, MTC FOUND AN EXISTING INSULATION RETAINING STUD HOLE IN THE LOCATION WHERE THE TEE CLIP EXTRUSION (P/N: P31839SDR DALA2021030501271Retaining Clip · misalignedWHILE PERFORMING 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING D18470-22207 REV. C AT FS 620 BETWEEN S-3R AND S-4R, MTC FOUND AN EXISTING INSULATION RETAINING STUD HOLE IN THE LOCATION WHERE THE TEE CLIP EXTRUSION (P/N: P31839-001) SDR DALA2021030501270Retaining Clip · misalignedDURING THE ACCOMPLISHMENT OF THE 2KU INSTALLATION PER GOGO DWG D18470-22207 REV C, AT FS 620 BETWEEN S-2R AND S-3R, MAINTENANCE FOUND AN EXISTING HOLE (0.159 DIA) FOR AN INSULATION BLANKET RETAINING CLIP THAT WILL FALL UNDERNEATH THE INTERCOSTAL BRACKET. REPASDR DALA2021030501269Retaining Clip · misalignedDURING THE ACCOMPLISHMENT OF THE 2KU INSTALLATION MAINTENANCE FOUND AN EXISTING HOLE (0.159 DIA) FOR AN INSULATION BLANKET RETAINING CLIP THAT WILL FALL UNDERNEATH THE INTERCOSTAL BRACKET AT FS 580 AND S-1 TO S-2L. C/W ERA 563974-14. (LP 0325033)SDR DALA2018120306992Structure · abnormalSHIP 684 WHILE IN FOR THE 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING REV. C AT FS 620 BETWEEN S-3L AND S-4L, MTC FOUND AN EXISTING INSULATION RETAINING STUD HOLE IN THE LOCATION WHERE THE TEE CLIP EXTRUSION IS TO BE INSTALLED TO SDR DALA2017120508426Battery Pack · inoperative(AIRCRAFT 655, L/P 3869004) R2 AND CENTER ISLE EXIT LIGHT BETWEEN R2/L2 INOP. R/R'D M732 BATTERY PACK IAW B757 AMM 33-51-07-902.SDR DALA2017120508455Door · out of adjustDOOR ARMED KNUCKLE KNOCKER INOPERATIVE. INSPECTED LT AFT EXIT DOOR ADJUSTED KNUCKLE KNOCKER OPS CHECK GOOD PER AMM 52-12.SDR DALA2018123107453Frame · gougedSHIP 6703 WHILE IN FOR THE 2KU WIFI MOD AND DURING THE RADOME INTERCOSTAL INSTALLATION PER GOGO DRAWING REV. C (REFERENCE AMDS WORKCARD) AT STA 620 BETWEEN STR 2R AND 3R, MTC REPORTED SIX (6) EXISTING FASTENER HOLES IN THE FRAME WHERE THE INTERCOSTAL T-CLIP ISSDR DALA2017120408424Connector · loose(AIRCRAFT 6704, L/P 0320392) SEAT ROW 43 R/H EMERGENCY LITES INOP. INSPECTED, RESECURED LOOSE CONNECTOR AT SEAT ROW 43 R/H EMERGENCY LITES. EMERGENCY LITES OP CHK NORMAL.SDR DALA2019012940511Structure · damagedWHILE IN FOR THE 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING REV. C (REFERENCE AMDS WORKCARD) AT FS 680 AT STR 3R, MTC REPORTED SIX (6) EXISTING OVERSIZED FASTENER HOLES. REF ERA 563820-14 REV A.SDR DALA2017120608452Charger · inoperativeSEAT MOUNTED EMERGENCY LIGHTS INOP ON ROWS 38-42. REMOVED AND REPLACED BATTERY PACK, NO HELP. REMOVED POWER PACK PER AMM 33-51. REMOVED AND REPLACED BATTERY CHARGING ASSY PER AMM 33-51, OP CK GOOD.SDR DALA2017112808375Sensor · dirtyINTERMITTENT RT AFT ENTRY DOOR EICAS MESSAGE ON FINAL APPROACH AT APPROXIMATELY 6000 FEET. LIGHT EXTINGUISHED AT APPROXIMATELY 4000 FEET ALL OTHER INDICATIONS WERE NORMAL. CLEANED AND ADJUSTED THE RT ENTRY DOOR SENSOR. OPS CHECKED GOOD.SDR DALA2018111906690None · noneSHIP 6704 WHILE IN FOR THE 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING REV. C AT FS 620 BETWEEN STR 2R AND 3R, MTC FOUND SIX (6) EXISTING HOLES IN THE LOCATION WHERE THE TEE CLIP IS TO BE MOUNTED TO THE FRAME. ER/A 563725 AUTHORIZSDR DALA2017112708371Light · brokenEMERGENCY LIGHT SEAT 22D BROKEN. REPLACED THE LIGHT IAW CMM 25-21-52. OPS CHECKED GOOD.SDR DALA2017112008250Shelf · crackedE2-2 SHELF FWD MOUNT HOLE CRACKED. REMOVED AREA DAMAGED AND INSTALLED A DOUBLER & FILLER ON THE E2-2 RACK IAW SRM 51-70-11.SDR DALA2018111906691None · noneSHIP 6701 AT STA 620 HAS 6 EA FASTENERS INTERFERES WITH INTERCOSTAL INSTALLATION. CORRECTIVE ACTION: REPAIRED PER ER/A 563545-14 REV ORIGINAL. (0304775)SDR DALA2017112008238Liner · out of positionR4 DOOR KNOCKER INOP. REPOSITIONED LOWER LINING ON DOOR R4 REF AMM 52-11. KNOCKER MOVES FREELY.SDR DALA2017112008237Shroud · out of adjustR3 DOOR "KNUCKLE KNOCKER" WILL NOT INDICATE DOOR IS ARMED. ADJUSTED SHROUD AROUND KNOCKER. OPS CK NORMAL, OK FOR SVC.SDR DALA2018110806543None · none(AIRCRAFT 693, L/P 0301852) WHILE IN ATL FOR THE 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING D18470-22207 REV. C (REFERENCE WORKCARD 2330-01349-01D) AT FR600 TO FR620 AND STR2R, MTC FOUND AN EXISTING LIGHTNING STRIKE REPAIR WITHINSDR DALA2017111708188Cover · out of positionL2 DOOR ARMING LEVER HARD TO OPERATE. REPOSITIONED THE SLIDE COVER AND OPS CHECKED GOOD.SDR DALA2017111708184Fuse · inoperativeCEILING EMERGENCY LIGHT ABOVE SEAT 1C INOPERATIVE. REMOVED AND REPLACED THE INVERTER FUSE IAW AMM 33-51. OPS CHECKED GOOD.SDR DALA2017111608183Cable · out of adjustCABLE WILL NOT DEACTIVATE GIRT BAR FROM OUTSIDE HANDLE WHEN OPENING THE L1 DOOR. DISASSEMBLE THE EMERGENCY CABLE FROM DOOR. REMOVED INTERIOR DOOR PANEL. ADJUSTED THE DISARM CABLE IAW AMM 52-11-20-825-001, STEP G. OPS GOOD IAW AMM 52-11-20. RETURNED DOOR TO SERSDR DALA2017111608182Bracket · crackedCRACK INDICATION FOUND IN THE RT NR 1 DUCT MOUNTING BRACKET, BS 500. REPAIRED IAW SRM 53-00-07, REPAIR 1.SDR DALA2017112008233Switch · inoperativeESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHTS DOOR 2L LIGHT INOP. REPLACED FWD SWITCH AT DOOR 2L OPERATES NORMALLY PER AMM 2566.SDR DALA2017111408143Power Supply · inoperativeROW 40, 44, 45 CEILING EMERGENCY LIGHTS INOPERATIVE. TROUBLESHOT IAW WDM 33-51-15. ALL THREE LIGHTS DO NOT RECEIVE POWER. WIRES FROM LIGHT 44 & 45 FOUND TO BE SPLICED TOGETHER. INSTALLED POWER SUPPLY M11649 & BATTERY, OPS CHECKED GOOD.SDR DALA2019012300460Skin · crackedSHIP 6709 A PREVIOUS BLEND OUT AND SEVERAL CRACKS WERE FOUND ON NR 2 CARGO DOOR OUTER SKIN. CORRECTIVE ACTION: DAMAGE WAS REPAIRED PER ETI-57-18-04 REV.2 AND ER/A 574365-14 REV. ORIGINAL SECTION I. AND LOG PAGE 0955190. (0297354)SDR DALA2018111906692None · noneSHIP 694 WHILE IN FOR THE 2KU WIFI MODIFICATION AND DURING THE RADOME INSTALLATION PER GOGO DRAWING REV. C AT FS 620 BETWEEN STR 2R AND 3R, MTC FOUND SIX (6) EXISTING HOLES IN THE LOCATION WHERE THE TEE CLIP IS TO BE MOUNTED TO THE FRAME. THE DRAWING REQUIRES
Back to Boeing 757-232