SDR IPXA2016073106506Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 211XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016073106504Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 212XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016073106503Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 440 FLOOR PANEL 232XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016073106502Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 440 FLOOR PANEL 231XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016073106501Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN AT BS 480 FLOOR PANEL 232XEF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016073106500Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 324 FLOOR PANEL 221XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072906446Floor Panel · delaminatedINSPECTION TYPE:SEG3, MAIN CABIN AT STA 480, FLOOR PANEL 231XEF DAMAGED. FABRICATED PANEL 231XEF FROM A402H-48X144 BAT 2852496 IAW SREO B757-5320-9692-H.SDR IPXA2016072906445Floor Panel · delaminatedINSPECTION TYPE:SEG3, MAIN CABIN AT STA 560 FLOOR PANEL 231XQF FABRICATED PANEL 231XQF FROM A402H-48X144, BAT 2852496 IAW SREO B757-5320-9692-H.SDR IPXA2016072906444Floor Panel · damagedINSPECTION TYPE: SEG3, MCD CABIN AT STA 324 FLOOR PANEL 221XBF DAMAGED. FABRICATED PANEL 221XBF FROM A402H-48X144, BAT 2852496 IAW SREO B757-5320-9692-H.SDR IPXA2016072606370Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN CABIN AT BS 480 FLOOR PANEL 232XFF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA2016072606369Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN CABIN BS 560 FLOOR PANEL 231XGF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2016072306186Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 440 FLOOR PANEL 231XBF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306185Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 440 FLOOR PANEL 231XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306184Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 720 FLOOR PANEL 232XPF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306183Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 324 FLOOR PANEL 222XBF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306182Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 324 FLOOR PANEL 222XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306180Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 324 FLOOR PANEL 221XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306179Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 440 FLOOR PANEL 232XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306178Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 324 FLOOR PANEL 222XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-9692-H.SDR IPXA2016072306176Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 440 FLOOR PANEL 232XBF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306175Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN AT BS 720 FLOOR PANEL 232XSF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306172Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN AT BS 560 FLOOR PANEL 231XHF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306171Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN AT BS 560 FLOOR PANEL 232XHF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306170Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN AT BS 480 FLOOR PANEL 231XDF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072306169Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN AT BS 480 FLOOR PANEL 232XDF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016071305799Control Panel · inoperativeEMERGENCY LIGHTS UNARMED LIGHT FAILS TO ILLUMINATE WHEN PANEL LIGHTS ARE IN TEST MODE. UNARMED LIGHT ILLUMINATES WHEN EMERGENCY LGIHTS SWITCH IS PLACED IN OFF POSITION. PERFORMED OPS CHECK IAW AMM 33-51-00-001. R & R EMERGENCY LIGHT PANEL.SDR IPXA2016071505882Attach Bracket · crackedINSPECTION TYPE: C-17, NR 1 PYLON INBD SIDE AT PANEL 435AR FWD LOWER STRUCTURE ATTACH BRACKET CRACKED. REMOVED & REPLACED ATTACH BRACKET.SDR IPXA2016071405869Transition Panel · corrodedINSPECTION TYPE: C-17, AFT CARGO BAY LEFT TRANSITION PANEL TOP SURFACE IS EXFOLIATED BS 1380. REPAIRED IAW EO B757-5320-3220-N.SDR IPXA2016071205754Floorboard · crackedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 231XOF CRACKED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2016071105708Floorboard · crackedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 242XEF CRACKED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2016072106135Door Frame · dentedINSPECTION TYPE: C-17, LWR AFT CARGO DOOR LOWER AFT FRAME IS GOUGEDREMOVED AND REPLACED AFT CARGO DOOR LWR AFT CORNER PER UPS B757-200PF SRM 51-40-02SDR IPXA2016070805582Bulb · inoperativeEMERGENCY LIGHT ASSY HAS INOPERATIVE BULBS. REPLACED THE BULBS IAW AMM 33-51-01-2.SDR IPXA2016071205765Battery Pack · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-07. OPS CHECKED NORMAL.SDR IPXA2016070805577Anti-Ice System · odorCLIMBING OUT, TURNED ENGINE ANTI-ICE ON AND GOT A HOT ODOR IN COCKPIT. NO SMOKE. WHEN ENGINE ANTI ICE TURNED OFF, ODOR WENT AWAY. ACCOMPLISHED ENGINE RUN TEST 3 IAW AMM 71-00-00. ENGINE INLET THREMAL ANTI-ICE SYSTEMS WERE OPERATED AT MULTIPLE POWER SETINGS.SDR IPXA2016070805543Floorboard · puncturedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 251XBF PUNCTURED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-HSDR IPXA2016070805542Floorboard · crackedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 232XHF CRACKED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2016070805541Floorboard · crackedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 231XEF CRACKED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2016070605496Floor Panel · puncturedINSPECTION TYPE: C-15, MAIN CABIN FLOOR PANEL 221XCF LOWER SURFACE HAS A PUNCTURE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2016070605495Floor Panel · delaminatedINSPECTION TYPE: C-15, MAIN CABIN FLOOR PANEL 241XBF DELAMINATED AT THE CORNERS. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016070605492Floorboard · delaminatedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 231XGF IS DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-HSDR IPXA2016070605491Floorboard · delaminatedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 232XGF IS DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-HSDR IPXA2016070605487Floor Panel · delaminatedINSPECTION TYPE: C-15, MAIN CABIN FLOOR PANEL 231XCF LOWER SURFACE DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016072206165Plate · corrodedINSPECTION TYPE: SEG4, LEFT ELEVATOR OB LOWER PLATE HAS CORROSION. REMOVED AND REPLACED THE PLATE IAW SRM 55-20-01-0I-1, AND DWG 183N2007.SDR IPXA2016072006095Plate · corrodedINSPECTION TYPE: SEG4, RT ELEVATOR O/B UPPER AND LOWER PLATE IS CORRODED.FOUND TWO SPLICE PLATES TO BE OUT OF LIMITS IAW SRM 55-20-01-1A-1 FABRICATED 2 EA NEW SPLICE PLATES IAW DWG 183N2007-6, INSTALLED SPLICE PLATES IAW SRM 55-20-01-1A-1 AND SRM 51-40-02-0GSDR IPXA2016071505923Attach Fitting · wornINSPECTION TYPE: SEG4, LEFT WING FLAP TRACK NR 3 IB ATTACH FITTING MOUNT HOLES WORN AND FASTENERS SHEARED. REPAIRED IAW SRM 57-53-02-2R-3 REPAIR 3 WITH NO DEVIATIONS REPAIR IS CLASSIFED AS A MAJOR REPAIR.SDR IPXA2016070805583Floor Panel · puncturedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XAF HAD NUMEROUS PUNCTURES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016071906059Skin · dentedINSPECTION TYPE: SEG4, SKIN DENTED BS 360, STRINGERS 15-16L. REPAIRED IAW EA 757-5311-27A2226 AND EO B757-5330-61249-A.SDR IPXA2016071105661Floorboard · damagedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 251XJF HAD EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2016071105659Floorboard · damagedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 251XFF HAD INSERTS AND EDGE DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2016070805581Floorboard · delaminatedINSPECTION TYPE: C-15, MAIN CABIN FLOORBOARD 251XFQ CORNER DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.
Back to Boeing 757-24APF