Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2016051003162Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 252XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016051003161Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 231XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016051003160Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 232XNF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016051103226Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 231XAF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016051103225Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 222XCF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016051103224Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 232XBF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016051103223Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL IS DELAMINATED. FABRICATED NEW FLOOR PANEL 231XBF IAW SREO B757-5320-9692-H.SDR IPXA2016051103229Floor Panel · delaminatedINSPECTION TYPE:C, FLOOR PANEL 242XAF IS DELAMINATED FABRICATED NEW FLOOR PANEL 242XAF IAW SREO 5320-9692-H.SDR IPXA2016051103227Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 221XAF IS DELAMINATED, FABRICATED NEW FLOOR PANEL 221XAF IAW SREO B757-5320-9692-H MATERIAL A402H BATCH 2862496.SDR IPXA2016050402934Door · lack of lubeFWD ENTRY DOOR WILL NOT CLOSE FROM THE INSIDE. LUBRICATED FWD CREW ENTRY DOOR IAW M12-21-20-643-00-1 OPERATED FINE. CREW ENTRY DOOR IAW AMM 52-12-00, DOOR OPS CHECKED GOOD.SDR IPXA2016052203673Skin · dentedINSPECTION TYPE:C-17, FUSELAGE SKIN DENT AT BS 1475, BETWEEN STR 25L- 26L. REPAIRED IAW REO-G19910.SDR IPXA2016042802727Skin · dentedINSPECTION TYPE:C-12, LEFT ELEVATOR LOWER SURFACE DENTED AT 16.75" FROM INBD END AND 34.5" FROM T/E DENT IN OUT LIMITS AREA DELAMINATED REMOVED DAMAGE ON LOWER SURFACE ON ELEVATOR LT, LAY UP VACCUM BAG REPAIR AREA, PREP AND REAPPLY FINISH ON REPAIR SURFACE, WESDR IPXA2016042602627Pitot Tube · obstructedON TAKEOFF AIRSPEED BECAME UNRELIABLE EICAS MESSAGE RATIO RATIO MACH SPEED TRIM A\S UNRELIABLE MESSAGES SHORT FINAL. WINDSHEAR WARNING F/O AIRSPEED BECAME UNRELIABLE ON SHORT FINAL. FOUND DEBRI ON CAPTAINS F/O AND AUX PITOT TUBES FLUSH THE PITOT STATIC SYS ISDR IPXA2016042102417Battery Pack · inoperativeEMERGENCY EXIT SIGN AND EGRESS INOPERATIVE AND REMOVED BATTERY IAW AMM-33-51-07-902-001.SDR IPXA2016042002405Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XHF IS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016042002382Warning Light · false activationEMERGENCY DECLARED ON SHORT FINAL DUE TO WHEEL WELL FIRE INDICATION. R & R DUCT LEAK DETECTION CARD IAW FIM 27-17-00-815 IAW BLOCK NR 1, 2, 3, 10, 11, 12, 13 & 24 R & R IAW MM 26-10-01-024-001 & 26-10-01-0424-006. PERFORMED ADJ/TEST AS REQIRED, NO FAULT AT TSDR IPXA2016050302903Angle · crackedINSPECTION TYPE:C-13, ARF EA ABOVE NLG, CLIP CRACKED AT BS 270.5 BL 0, R CLIP IAW SRM 51-40-02.SDR IPXA2016042602635Frame · corrodedINSPECTION TYPE:SEG4, AFT PIT BS 1380 FRAME WEB IS CORRODED BETWEEN S-2R AND S-27R, REPAIRED IAW PF SRM 53-00-07-2R-2, FIGURE 201, DETAIL 2.SDR IPXA2016041402130Lever · malfunctionedEMERGENCY DECLARED, T/E DISAGREE CAUTION MESSAGE DISPLAYED WHEN SELECTING FLAPS 1. RAN T/E FLAP DISAGREE CHECKLIST AND LANDED WITH FLAPS 20. ALTERNATE FLAP EXTENSION AND RETRACTION WORKED NORMALLY. OPERATED THE FLAPS AND SLATS SEVERAL TIMES HYDRAULICALLY WITSDR IPXA2016041102003Wire · brokenEMERGENCY LIGHT GUARDED SWITCH ARMING DEVICE BROKEN. R & R EMERGENCY LIGHTS SWITCH GUARD. OK TO CONTINUE.SDR IPXA2016042502573Floor Support · corrodedINSPECTION TYPE:C-12, AFT PIT, FLOOR STRUCTURE AND BILGE SKIN CORRODED, BS 1400-RBL 3. REPLACED INTERCOSTAL BS 1400 TO BS 1420 AT RBL 3.SDR IPXA2016042502571Strap · corrodedINSPECTION TYPE:C-12, AFT PIT, FLOOR STRUCTURE AND BILGE SKIN CORRODED BS 1400-RBL 3. REPLACED STRAP BS 1400, S28R-S26L.SDR IPXA2016042602621Skin · delaminatedINSPECTION TYPE:CRT WING OTBD FORE FLAP UPPER SURFACE HAS NUMEROUS DENTS WITH DELAMINATION. REPAIRED 21 EA 2" DIAMETER AREAS IAW SRM 57-53-01-2R, REP 1, TABLE III AND 51-70-07-0G, PARA 5A.SDR IPXA2016042602620Skin · delaminatedINSPECTION TYPE:C, LEFT WING OTBD FLAP UPPER SURFACE HAS SEVERAL AREAS OF DELAMINATION. REPAIRED 3EA AREAS, 2 DIAMETERS IAW SRM 57-53-01-2R, REP1 TABLE III, SRM 51-70-07-0G, PAR 5A.SDR IPXA2016040801828Attach Bracket · crackedINSPECTION TYPE:C10, 313AL LT LATCH PAD BRACKET LOWER ATTACH FLANGES CRACKED INSTALLED REPAIR ANGLES ON LATCH PAD BRACKETS IAW SRM 51-70-11-0G.SDR IPXA2016041602206Frame · dentedINSPECTION TYPE:C-12, AFT CARGO COMPARTMENT RT FRAME AT BS 1500 IS DENTED APPROXIMATELY 4" ABOVE S26R. REPAIRED FRAME AT RT BS 1500 IAW SRM 53-00-+07-2R-5, FIG 201,
DETAIL II.SDR IPXA2016041302074Web · crackedINSPECTION TYPE:SEG 3, MAIN DECK AT BS 860-879, RBL45 HAS WEB CRACKED. FABRICATED AND INSTALLED NEW WEB ON MAE TRAVELER T16/1201633 IAW SRM 51-40-02-0G.SDR IPXA2016041602198Skin · damagedINSPECTION TYPE:SEG 3, LT WING INBD FLAP LOWER SURFACE FWD INBD MOUNT ANGLE FOR FAIRING 572HB LOOSE. REPAIRED IAW SRM 57-53-02-2R, PROCEDURE 3.SDR IPXA2016040501720Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 251XCF DAMAGED. FABRICATED FLOOR PANEL 251XCF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501718Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 252XQF DAMAGED. FABRICATED FLOOR PANEL 252XQF FROM A402H-48X144, BATCH 2801694 IAW SREO 5320-9692-H.SDR IPXA2016041302076Structure · crackedINSPECTION TYPE:SEG 3, MAIN DECK BS 480-500 WEB BETWEEN LBL 24 AND LBL 45 IS CRACKED ON TOP. REMOVED, FABRICATED AND INSTALLED NEW CHORD ON TR T16,1200231 IAW SRM 51-40-02.SDR IPXA2016041302075Intercostal · crackedINSPECTION TYPE:SEG 3, MAIN DECK BS 480-500 WEB BETWEEN LBL 24 AND LBL 45 IS CRACKED ON TOP. REMOVED, FABRICATED AND INSTALLED NEW INTERCOSTAL ON TR T16, 1200573 IAW SRM 51-40-02.SDR IPXA2016041302073Seat Track · damagedINSPECTION TYPE:SEG 3, MAIN DECK BS 880-900, RBL 45 SEAT TRACK DAMAGED. REMOVED FABRICATED SEAT TRACK, PN BAC1520-2472 AND INSTALLED NEW SEAT TRACK IAW SRM 51-40-02-06.SDR IPXA2016040501716Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 232XSF DAMAGED. FABRICATED FLOOR PANEL 232XSF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016041202017Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 252XUF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016041202016Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 232XCF DAMAGED. FABRICATED AN NEW FLOOR PANE IAW SREO B757-5320-9692-H.SDR IPXA2016040701781Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 222XAF DAMAGED. FABRICATED FLOOR PANEL IAW SREO BB757-5320-9692-H.SDR IPXA2016040501721Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 222XCF DAMAGED. FABRICATED FLOOR PANEL 222XCF FROM A402H-48X144 BATCH 2801694 IAW SREO 5320-9692-H.SDR IPXA2016040501719Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 221XAF DAMAGED. FABRICATED FLOOR PANEL 221XAF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501715Floor Panel · damagedINSPECTION TYPE:SEG, MAIN CARGO FLOOR PANEL 221XCF DAMAGED. FABRICATED FLOOR PANEL 221XCF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501712Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 232XBF DAMAGED FABRICATED FLOOR PANEL 232XBF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501711Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 231XCF DAMAGED. FABRICATED FLOOR PANEL 231XCF FROM A402H-48X144 BATCH NR 2801694 IAW SREO 5320-9692-H.SDR IPXA2016040201518Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN CARGO FLOOR PANEL 231XBF DAMAGED. FABRICATED FLOOR PANEL 231XBF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040201517Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN CARGO FLOOR PANEL 231XAF DAMAGED. FABRICATED FLOOR PANEL 231XAF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040201519Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN CARGO FLOOR PANEL 232XAF DAMAGED. FABRICATED FLOOR PANEL 232XAF FROM A402H-48X144, BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040101486Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 221XBF DAMAGED. FABRICATED FLOOR PANEL 221XBF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040401631Shear Tie · corrodedINSPECTION TYPE:C, AFT CARGO SHEAR TIE BETWEEN STR 29R AND 28R AT BS 1400 HAS CORROSION DAMAGE. R & R SHEAR TIE, PN:146N1603-2, IAW SRM 51-40-02-0G AND DWG 146N1011 NEW SHEER TIE FABRICATED ON VTMAE TRAV T16/1198516, NO FOLLOW-UP OR REPEAT INSP ARE REQUIRED RSDR IPXA2016040401644Strap · corrodedINSPECTION TYPE:SEG4, AFT CARGO SPLICE STRAP AT BS 1401 BETWEEN STR 26L TO 28R HAS EXTENSIVE CORROSION DAMGE. R & R SPLICE STRAP, PN 146N381-8200 IAW SRM 51-40-02-0G AND DWG 146N3305, NEW STRAP FABRICATED ON VTMAE TRAV T16/1199405. REPLACEMENT OF SPLICE STRSDR IPXA2016032301149Battery Pack · weakEXIT LIGHT BATTERY WEAK. R & R EXIT LIGHT BATTERY IAW AMM 33-51-00. OPS NORMAL.SDR IPXA2016040501723Transition Panel · corrodedINSPECTION TYPE:C10, AFT PIT RT TRANSITION PANEL HAS CORROSION NEAR TIE DOWN FITTING AT BS 1280 INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-70-13.
Back to Boeing 757-24APF