SDR IPXA2014042882801Floor Panel · damagedDURING C-11 INSPECTION, MAIN CABIN FLOOOR PANEL 232XGF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2014042882797Angle · corrodedLEFT WING OTBD MAIN FLAP ANGLE CORRODED. REPAIRED IAW EO B757-5750-54168-A.SDR IPXA2014050282833Floor Panel · damagedDURING C13S INSPECTION, MAIN CARGO FLOOR PANEL 242XEF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO757-5320-9692-H.SDR IPXA2014050282832Floor Panel · damagedDURING C13S INSPECTION, MAIN CARGO FLOOR PANEL 242XDF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW 757-5320-9692-H.SDR IPXA2014050282831Floor Panel · damagedDURING C13S INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XAF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014050282830Floor Panel · damagedDURING C13S CHECK, MAIN CARGO DECK FLOOR PANEL 242XAF HAS DAMAGED EDGE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014042882807Floorboard · damagedDURING A C-11 INSPECTION, MAIN CABIN FLOORBOARD 231XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882806Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBAORD 252XKF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882804Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBAORD 231XHF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882803Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBOARD 231XGF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882790Floorboard · damagedDURING C11 INSPECTION, MAIN CABIN FLOORBOARD 231XWF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882783Floorboard · damagedDURING A C-8 INSPECTION, MAIN CABIN FLOORBOARD 251XRF FOUND WITH EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882782Floorboard · damagedDURING C-8 INSPECTION, MAIN CABIN FLOORBOARD 252XUF FOUND WITH EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882780Floor Panel · damagedDURING C11 INSPECTION, FLOOR PANEL 211XAF HAS CORE DAMAGE AND SURFACE DISBONDED. FABRICATED FLOOR PANEL IAW SREO B757-5320-4692-H.SDR IPXA2014042882779Floor Panel · delaminatedC11 INSPECTION, FLIGHT DECK FLOOR PANEL IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2014042382729Skin · dentedFUSELAGE SKIN DENTED AT BS 1522, STRINGER 29L. REPAIRED IAW EO B757-5330-54125-A.SDR IPXA2014042182731Bulb · inoperativeEMERGENCY LIGHT ASSY HAS FIVE BULBS INOPERATIVE. REPLACED BULBS IAW AMM 33-51-01-2.SDR IPXA201404182702Actuator · failedAIRSPEED WAS AT 210 WHEN FLAPS ONE WAS SELECTED, L/E SLAT DISAGREE WHEN FLAPS ONE SELECTED. ALTERNATE FLAPS USED TO GET FLAPS OUT IAW ALERT H2149934. R & R NR 11 L/E ROTARY ACTUATOR AND RT L/E SLAT POS TRANSMITTER IAW 27-81-18-01 AND 27-58-01 DELTA +0.47. SDR IPXA2014041682683Bulb · inoperativeEMERGENCY LIGHT ASSY HAS FOUR BULBS INOPERATIVE. REPLACED BULBS IAW AMM 33-51-01-2.SDR IPXA2014041682667Warning Message · false indicationT/E FLAP DISAGREE, FLAPS STUCK AT 20 ON EXTENTION. WHEN MOVING FLAP HANDLE FROM 20-25 AT 170KTS, MESSAGE AT TRANSIENT, LOAD RELEIF EICAS MESSAGE. EMERGENCY DECLARED. PERFORMED FSEU BITE IAW FIM 27-51-00-815-805-104, NO FAULTS NOTED. T/E FLAP LOAD RELIEF SYSDR IPXA2014041482648Actuator · inoperativeEMERGENCY DECLARED, L/E SLAT DISAGREE EICAS MESSAGE WITH L/E LIGHT. LANDED UNEVENTFULLY. IAW FIM 27-51-00-815, FIG 104 NR 1 FSEU REPORTS CODE 310, NR 2 FSEU REPORT CODE 330. FOUND PDU LT AND RT TORQUE LIMITERS TRIPPED AND NR 8 OTBD LIMITER TRIPPED. RESET PSDR IPXA2014041182613Floor Panel · crackedINSPECTION: S3CP, MAIN DECK FLOOR PANEL 231XHF CRACKED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014582589Warning Message · false activationT/E FLAP DISAGREE. EMERGENCY DECLARED, PERFORMEND VISUAL INSPECTION OF FLAPS/SLATS AND FSEU BITE IAW FIM NO PREVIOUS OR CURRENT FAULTS DETECTED. FLAP OPS CHECKED NORMAL THRU SEVERAL CYCLES WITH NO FAULTS.SDR IPXA2014041682673Floorboard · gougedINSPECTION S2CP, UPPER CARGO FLOORBOARD 241XFF HAS GOUGE AND CORE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014582670Floor Panel · damagedINSPECTION S2CP, UPPER CARGO FLOOR PANEL 242XFF HAS EDGE DAMAGE AND SOFT CORE MATERIAL AND SOFT CORE MATERIAL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682668Floorboard · damagedINSPECTION S2CP, UPPER CARGO FLOORBOARD 242XEF HAS EDGE DAMAGED AND SOFT CORE MATERIAL. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014041682674Floor Panel · damagedINSPECTION S2CP, CABIN FLOOR PANEL 241XHF HAS EDGE DAMAGE, AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014042582762Skin · tornDURING S2CP INSPECTION, LEFT OTBD AFT FLAP HAS A TWO INCH TEAR IN UPPER SURFACE EIGHT INCHES OTBD OF INBD EDGE AND FOURTEEN INCHES FWD OF T/E. FOUND WITHIN LIMITS IAW SRM 57-53-01-2R-1,TABLE 11.2.SDR IPXA2014042182709Floor Panel · damagedDURING S2CP INSPECTION, FLOOR PANEL 241XCF HAS EDGE DAMAGE & DELAMINATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320, 9692-H.SDR IPXA2014041682676Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XGF HAS EDGE AND CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682675Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XDF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682672Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XEF HAS EDGE, CORNER, HOLE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682671Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XHF HAS A MISSING INSERT. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041482626Floor Panel · damagedINSPECTION: C10, MAIN CABIN FLOOR PANEL 241XGF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW REOB757-5320-9692.SDR IPXA2014040282491Floor Panel · damagedINSPECTION C10, MAIN CABIN FLOOR PANEL 231XVF IS DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA2014040482505Floorboard · damagedINSPECTION S3CP, UPPER CARGO FLOORBOARD 242XLF MISSING CORE MATERIAL AND SPONGY. FABRICATED NEW FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA2014033182464Floorboard · damagedINSPECTION C-10, MAIN CABIN FLOORBOARD 241XCF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014033182463Floorboard · damagedINSPECTION C-10, MAIN CABIN FLOORBOARD 241XAF IS DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320 9 9692-H.SDR IPXA2014040982591Floorboard · damagedINSPECTION: S3CP, UPPER CARGO FLOORBOARD 252XUF HAS CRUSHED CORE, FOUND WITH TAPE REMOVED. FABRICATED NEW FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA2014040982582Floorboard · damagedINSPECTION: S3CP, UPPER CARGO BAY FLOORBOARD 231XDF HAS MISSING CORE MATERIAL AND SPONGY. FABRICATED NEW FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA2014040782560Access Panel · corrodedINSPECTION C-10, CORROSION ON RT HORIZONTAL ACCESS PANEL 345HB. REPLACED ACCESSPANEL WITH NEW IAW SRM 51-40-02.SDR IPXA2014041482628Panel · delaminatedINSPECTION: C9, RT LOWER VERTICAL STAB TORQUE BOX PANEL IS DELAMINATED SEVERAL AREAS. REPAIRED IAW REO-G17337, REV B & EO B757-5530-54064-A.SDR IPXA2014040482540Floorboard · puncturedINSPECTION S3CP, MAIN DECK FLOORBOARD 252XFF IS PUNCTURED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014040482519Floorboard · puncturedINSPECTION S3CP, MAIN DECK FLOORBOARD 221XBF IS PUNCTURED. FABRICATED NEW FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA2014040482516Floorboard · damagedINSPECTION S3CP, MAIN DECK FLOORBOARD 251XEF HAS TORN FASTENER HOLE AND MATERIAL SEPARATION. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014504042514Floorboard · puncturedINSPECTION S3CP, MAIN DECK FLOORBOARD 251XMF IS PUNCTURED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014032882437Warning Message · false activationDURING APPROACH, L/E SLAT DISAGREE EICAS AND LIGHT ILUMINATED. CHECKLIST PROCEDURES FOLLOWED. FLAPS 20 LANDING PERFORMED FAULT ISOLATION PROCEDURES IAW FIM 27-81-00-815-803. CHECKED FOR HYD LEAKS AND ANY TYPE OF OBSTRUCTION. NO DEFECTS FOUND. OPERATED THE LSDR IPXA2014040482526Floorboard · puncturedINSPECTION S3CP, MAIN DECK FLOORBOARD 252XQF PUNCTURED ON BOTTOM. FABRICATED NEW FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA2014040482501Floorboard · puncturedINSPECTION S3CP, MAIN DECK FLOORBOARD 251XGF IS PUNCTURED ON BOTTOM, STR REQUEST. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014504022471Floor Panel · damagedINSPECTION C10, MAIN CARGO FLOOR DAMAGED. FABRICATED NEW FLOOR PANEL.
Back to Boeing 757-24APF