Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3576970Transition Panel · corrodedINSPECTION TYPE:C16, AFT CARGO BILGE AREA TRANSITION PANEL CORRODED AROUND THE NUTPLATE BOTTOM AND TOP SIDES BS 1440-1480. REMOVED CORROSION, ORIG MAT .063 IAW SRM 53-60-53 MAT REMOVED .003; MATERIAL REMAINING .060 AREA WITHIN LIMITS IAW SRM 53-00-53. ALODISDR IPXA3576969Transition Panel · corrodedINSPECTION TYPE: C16, AFT CARGO BILGE AREA TRANSITION PANEL CORROSION AROUND BOTTOM BS 1460-1480. REMOVED CORROSION ORIG MAT .063 IAW SRM 53-60-53. MAT REMOVED .003 MAT REMAINING .060 AREA WITHIN LIMITS IAW SRM 53-00-53. ALODINED AND PRIMED IAW SRM 51-20-01SDR IPXA3576968Transition Panel · corrodedINSPECTION TYPE: C-16 AFT CARGO BILGE AREA TRANSITION PANEL HAS CORROSION AROUND NUTPLATES ON BOTTOM (LT SIDE) BS 1280-1300. REMOVED CORROSION ORIG MAT .063 IAW SRM 53-60-53, MAT REMOVED .002 MAT REMAINING .061 AREA WITHIN LIMITS IAW SRM 53-00-53 ALODINED ANSDR IPXA3576967Transition Panel · corrodedINSPECTION TYPE: C16 AFT CARGO BILGE AREA. TRANSITION PANEL. CORROSION AROUND NUTPLATES ON BOTTOM (LT SIDE) BS 1260-1240. REMOVED CORROSION ORIG MAT .063 MAT REMAINING 060 MAT REMOVED .003. ALODINED , PRIMED & PAINTED, REMOVED CORROSION, ORIG MAT .063 IAW SRSDR IPXA3576966Transition Panel · corrodedINSPECTION TYPE: C16, AFT CARGO BILGE AREA. TRANSITION PANEL CORROSION AROUND NUTPLATE BOTTOM AND TOP SIDE BS 1440-1460. REMOVED CORROSION. ORIG MAT .063 IAW SRM 53-60-53. REMOVED .004 MAT REMAINING .059. AREA WITHIN LIMITS IAW SRM 53-00-53. ALODINED AND PRISDR IPXA3576954Transition Panel · corrodedINSPECTION TYPE: C-16 AFT CARGO BAY RT TRANSITION PANEL CORRODED AROUND NUTPLATE BOTTOM SIDE BS 1300. REMOVED CORROSION. ORIG MAT .063 IAW SRM 53-60-53 MAT. REMOVED .003 MAT REMAINING .060 AREA WITHIN LIMITS IAW SRM 53-00-53 ALODINED AND PRIMED IAW SRM 51-20SDR IPXA3576951Floor Panel · damagedINSPECTION TYPE:S4C8, MCD FLOORBOARD 222XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA3576949Floor Panel · damagedINSPECTION TYPE: S4C8, MCD FLOOR PANEL 221XCF HAS EDGE DAMAGE. DOT 11-71, FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3576820Bracket · crackedINSPECTION TYPE: C13, RT WING OTBD FLAP INBD JACK TRANSMISSION SUPPORT BRACKET CRACKED, OUT OF LIMITS IAW SRM 51-10-02. R & R BRACKET FITTING IAW AMM 27-15-17-424.SDR IPXA3576952Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 231XFF IS DELAMINATED ON THE EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3576950Floor Panel · damagedINSPECTION TYPE: S4C8, MCD FLOOR PANEL 232XUF UPPER SKIN RIPPED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3576902Floor Panel · brokenINSPECTION TYPE:S4C8, MAIN CARGO DECK FLOOR PANEL 231XMF BROKEN. FABRICATED NEW FLOOR PANEL.SDR IPXA3576895Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN CARGO FLOOR PANEL 232XMF UPPER SKIN RIPPED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576894Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN CARGO DECK FLOOR PANEL 232XRF UPPER SKIN RIPPED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576893Floor Panel · damagedINSPECTION TYPE:S4C8, MCD FLOOR PANEL 232XHF UPPER SKIN RIPPED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576822Adc · inoperativeEMERGENCY DECLARED, ACFT SUDDENLY PITCHED UP AND TRIM SEEMED TO RUNAWAY. TROUBLESHOT, R & R LT ADC SYS TESTED OK IAW MM 34-12-00-71-001. LT SAM TO BE CHANGED. PN 044 4040-800-912, SN OFF 92053291. R & R LT STAB TRIM ELEVATOR ASSYMMETRY LIMIT MODULE AND TESDR IPXA3576960Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN CARGO FLOOR PANEL 232XJF HAS A HOLE DRILLED WHERE NO FASTENER IS LOCATED AND EDGES ARE WORN. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3576907Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL 232XFF SCREW INSERT MISSING. FABRICATED NEW FLOOR PANEL.SDR IPXA3576906Floor Panel · brokenINSPECTION TYPE: S4C8, MAIN CARGO FLOOR PANEL 241XDF HAS BROKEN INSERTS AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL.SDR IPXA3576905Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN CARGO FLOOR PANEL 241XMF IS MISSING INSERTS AND HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL.SDR IPXA3576904Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL 232XAF FWD EDGE BS 440, DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576903Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN CARGO FLOOR PANEL 232XSF HAS MISSING INSERTS AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL.SDR IPXA3576901Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL 231XBF, BS 440 DAMAGED AT INBD EDGE FABRICATED NEW FLOOR PANEL.SDR IPXA3576900Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL 231XTF, BS 820-900, DAMAGED ON ALL FOUR EDGES AND MISSING A SCREW INSERT. FABRICATED NEW FLOOR PANEL.SDR IPXA3576899Floor Panel · brokenINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL, 231XWF, BS 879 HAS FOUR SCREW INSERTS MISSING NR 53-93. FABRICATED NEW FLOOR PANEL.SDR IPXA3576898Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL, 232XYF, BS 879 HAS A SCREW INSERT MISSING. FABRICATED NEW FLOOR PANEL.SDR IPXA3576897Floor Panel · wornINSPECTION TYPE :S4C8, MAIN CARGO COMPARTMENT FLOOR PANEL 251XCF HAS WORN EDGES. FABRICATED NEW FLOOR PANEL.SDR IPXA3576896Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL 222XAF AFT EDGE BS440 DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576892Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN DECK FLOOR PANEL 231XAF BS 440-480 DAMAGED ON ALL FOUR SIDES. FABRICATED NEW FLOOR PANEL.SDR IPXA3576883Floor Panel · damagedINSPECTION TYPE: S4C8, MAIN DECK FLOOR PANEL 221XAF AFT EDGE BS 440 DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576881Floor Panel · damagedINSPECTION TYPE: C8, MAIN DECK FLOOR PANEL 232XBF FWD EDGE BS 440, DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA3576959Floor Panel · damagedINSPECTION TYPE:S4C8, FLOOR PANEL 251XRF AT BS 1680-1720, BL-0 TO LBL-45 IS DELAMINATED ON FWD CORNER AND HAS BROKEN AND MISSING INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-53 20-9692-H.SDR IPXA3576961Floor Panel · damagedINSPECTION TYPE: S4C8, COURIOR COMPARTMENT FLOOR PANEL 211XAF HAS DAMAGED EDGES AND LOOSE INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-53 20-9692-H.SDR IPXA3576921Floor Panel · damagedINSPECTION TYPE: S4C8, FLOOR PANEL 231XJF BS 560-620 HAS SPOT OF DELAMINATION AND DAMAGED ON ON EDGE. FABRICATED NEW FLOOR PANEL.SDR IPXA3576800Skin · dentedINSPECTION TYPE:C10, RT WING NR 6 SLAT UPPER AREA COMPOSITE DENTED. FABRICATED AND INSTALLED A REPAIR IAW SRM 57-41-02-2R-1, MAJOR REPAIR.SDR IPXA3576797Skin · damagedINSPECTION TYPE:C10, RT WING NR 6 SLAT WEDGE UPPER SURFACE 19" FROM OTBD EDGE. FABRICATED AND INSTALLED A REPAIR IAW SRM 57-43-02-2R-1, MAJOR REPAIR.SDR IPXA13576980Frame · corrodedINSPECTION TYPE:S4C8, APU INLET DOOR HSG CUT-OUT FWD FRAME CORRODED. REMOVED AIR INTAKE HSG IAW 49-15-08-004-001, EMP: 05948. UPON REMOVAL OF AIR INTAKE HSG FOUND MORE CORROSION ON THE MATING SURFACES OF THE UPPER LOWER AND AFT SUPPORT FLANGES. REMOVED 9EASDR IPXA3576962Skin · dentedINSPECTION TYPE: S4C8, DENT ON LOWER SKIN OF LT INBD MAIN FLAP AT MF STA 130.0. DENT 1.25" X .75" X .035 DEEP WITH A SMALL PUNCTURE DRILLED .0625 DIAM HOLE TO CLEAN UP PUNCTURE, FABRICATED REPAIR PARTS IAW 51-70-10-2R-REP NR 2.SDR IPXA13576679Skin · dentedLEFT WING INBD MAIN FLAP T/E SKIN DENTED. REPAIRED IAW EO B757-5750-49091-B.SDR IPXA3576801Floorbeam · corrodedINSPECTION TYPE: C10, MAIN CABIN UNDER FLOORBEAM TEE CORRODED BS 1055, RBL 0-25, CORRODED OUT OF LIMITS. R & R FLOORBEAM TEE IAW DWG 144N5005.SDR IPXA3576798Floorbeam · corrodedINSPECTION TYPE:C10, MAIN CABIN UNDER FLOORBEAM TEE CORRODED BS 1055, RBL 25- RBL-50 CORROSION OUT OF LIMITS. R & R FLOORBEAM TEE IAW BAC DWG 144N5005, MINOR REPAIR.SDR IPXA3576795Floorbeam · corrodedINSPECTION TYPE: C10, MAIN CABIN UNDER FLOORBEAM CORRODED BS 1040, RBL 0-25 CORRODED OUT OF LIMITS. R & R TEE IAW DWG 144N5005. MINOR REPAIR.SDR IPXA3576620Skin · dentedTAILCONE OUTER SKIN DENTED, DAMAGE 2 INCHES IN DIA, DEPTH .016 AT FS 1954 3.4, LBL. REPAIRED IAW EO B757-5330-47030-B.SDR IPXA3576811Channel · chafedINSPECTION TYPE:C13, NR 2 PYLON LT HYD BAY ACCESS FWD INNER U-CHANNEL CORNER CHAFING AGAINST VERTICAL ANGLE. FABRICATED AND INSTALLED NEW REPAIR GUSSET AND TRIMMED BACK DAMAGED CHORD TO ALLOW CLEARANCE.SDR IPXA3576784Skin · dentedINSPECTION TYPE:C, LT INBD MAIN FLAP DENT 48" INBD OF OTBD EDGE 22" FWD OF T/E UPPER SUR FACE REF I477607, REPAIRED IAW SRM 51-70-10 REPAIR 3 AND 4 FIG 201. MAJOR REPAIR.SDR IPXA3576789Frame · dentedINSPECTION TYPE: C13, AFT CARGO COMPARTMENT RT SIDEWALL AREA, FRAME UPPER FLANGE DENTED AT BS 1280 ABOVE S24R FOUND TO BE OUT OF LIMITS IAW SRM 53-00-71-1A-1. REPAIRED FRAME IAW SRM 53-00-07-2R-6 DETAIL III MAJOR REPAIR,SDR IPXA3576788Skin · dentedINSPECTION TYPE: C-13, DENT ON CREW ENTRY DOOR EXTERNAL SKIN 11 INCHES FROM BOTTOM, 3 INCHES FROM FWD END. DENT FOUND TO BE WITHIN LIMITS IAW SRM 52-10-01 -1A-1, FIG 101, SHEET 2,3 DETAIL IV. REPAIRED IAW SRM 52-10-01-2R, REPAIR 7. MAJOR REPAIR.SDR 2013FA0000005Skin · damagedFUSELAGE SKIN DAMAGED, BS 243.SDR IPXA12576574Skin · dentedLEFT WING OTBD T/E AFT FLAP DENTED. REPAIRED IAW EO B757-5750-49452-A.SDR IPXA12576573Skin · dentedLT WING OTBD T/E AFT FLAP DENTED. REPAIRED IAW EO B757-5750-49452-A.
Back to Boeing 757-24APF