SDR IPXA2575727Cargo Track · corrodedINSPECTION TYPE: C, MAIN CARGO TRACK BS 879-900 4 EACH FASTENER HOLE CORRODED LBL 44. FABRICATED AND INSTALLED NEW CARGO TRACK EXPANSION JOINT SECTION FROM BS 879-900 LBL 45 IAW DWG 143N5470.SDR IPXA2575705Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 212XAF HAS DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575677Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 222XAF HAS MISSING INSERT. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575642Lamp · inoperativeEMERGENCY EXIT SIGN HAS FIVE LAMPS INOPERATIVE. LAMPED THE EXIT SIGN IAW AMM 33-51-01.SDR IPXA2575759Skin · dentedINSPECTION TYPE: C, FWD CARGO BAY HAS DENT IN SKIN BS 817 BETWEEN 23R AND 24R. CUT OUT DENT, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-01-2R, REPAIR 3.SDR IPXA12575596Floor Panel · crackedINSP TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XPF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575783Frame · dentedINSPECTION TYPE:C-CK, FWD CARGO COMPARTMENT STA 820 AT STR 24 LT DENTED. REPAIRED IAW SRM 53-00-07-2R, REPAIR 5, DETAIL III.SDR IPXA12575597Floor Panel · crackedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XHF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575595Floor Panel · crackedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 232XGF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575594Floor Panel · crackedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XLF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575565Floorboard · crushedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 251XKF UPPER SURFACE FORWARD OF CORNER AND THE CORNER IS CRUSHED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-969 2-H.SDR IPXA2575564Floor Panel · brokenINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 252XQF HAS TWO BROKEN INSERTS FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575839Floorbeam · corrodedINSPECTION TYPE: C, BS 1200, LBL 33, WL 208 CORROSION ON AFT FLANGE OF FLOORBEAM. REPAIRED FLOORBEAM IAW DWG LOR5L53006 (REV B) REPAIR 1A.SDR IPXA2575521Module · inoperativeMACH AIRSPEED, TRIM AND RUDDER RATIO INOP MESSAGES AT APPROX 1000 AGL, ON CLIMB LOST CAPTAINS INSTRUMENTS. BELLS AND WHISTLES TERRAIN, WINDSHEAR MESSAGE APPEARED. ATC SHOWED US AT 0 FEET LEVEL AT 6000. F/O INSTRUMENT OK LAND INDICATED FAST & SLOW ON ADI INTSDR IPXA2575758Floorbeam · corrodedINSPECTION TYPE: C, FLOORBEAM, BS 1200 TOP CAP FROM LBL 1 TO LBL 45 HAS SEVERAL AREAS OF CORROSION AROUND FASTENER HOLES. REPAIRED FLOORBEAM IAW LOR DWG LOR5L5300R (REV B) REPAIR 1C.SDR IPXA2575520Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XPF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575510Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 242XJF DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575509Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XVF. FABRICATED FLOORBOARD IAW EO B757-5320-9692-HSDR IPXA2575507Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XNF. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575499Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XRF DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575497Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XRF. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575496Floorboard · damagedINSPECTION TYPE: C, FLOOR PANEL 241XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575495Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XVF DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575494Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XCF DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575492Skin · gougedMAIN CARGO DOOR SKIN GOUGED AND DENTED. REPAIRED IAW EO B757-5230-48631-A.SDR IPXA2575482Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 211XAF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575487Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XBF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2575486Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XNF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575483Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XEF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575450Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XLF DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575430Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 222XCF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575429Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 231XNF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575428Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 242XGF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575427Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 232XSF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575426Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XTF DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575424Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 241XEF DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575567Floor Panel · brokenINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XJF IS BROKEN AND BLOWN OUT AT BOTH SIDES AND FORWARD INBD CORNER. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575566Floor Panel · brokenINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XCF IS BROKEN IN MULTIPLE AREAS. FABRICATED NEW FLOOR PANEL IAW EO B757-5 320-9692-H.SDR IPXA2575557Floor Panel · brokenINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XSF IS BROKEN AT AFT EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575556Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XQF IS DELAMINATED AND BLOWN OUT AT AMIING INSERTS ALONG THE OTBD EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575549Floorboard · delaminatedINSPECTION TYPE: C, FLOORBOARD 241XJF DELAMINATED AND HAS A BAD INSERT FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575548Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XEF AFT INBD CORNER DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575547Floorboard · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 251XCF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575539Floor Panel · brokenINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XMF IS BROKEN IN HALF. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575530Floorboard · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 251XJF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575529Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 222XBF HAS MULTIPLE AREAS OF CRUSH AND DELAMINATED DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575525Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XXF IS CRUSHED AT AFT INBD CORNER. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575524Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XRF IS CRUSHED AT FWD & AFT CORNERS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575522Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 242XAF IS CRUSHED AT AFT CORNER. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575519Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 252XBF HAS DAMAGED CORE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.
Back to Boeing 757-24APF