Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2574428Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XLF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574427Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XEF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574426Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XFF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574408Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XNF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574391Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XCF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574390Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XDF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574389Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 251XFF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574387Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 231XHF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574385Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XGF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574368Floorboard · damagedINSPECTION TYPE: C, AFT LT FLOORBOARD 251XNF INSERT PULLED FROM EDGE. FABRICATED A CARGO FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574364Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574348Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XPF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574339Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XMF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574544Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 252XTF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574473Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 231XEF INSERT BROKEN & DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574403Engine · failedINSPECTION TYPE: ATB - IFSD LT ENGINE FAILED ON CLIMB. EMERGENCY DECLARED RETURNED TO DEPARTURE. R & R NR 1 ENGINE IAW TC-5001.SDR IPXA2574386Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XQF DAMAGED. FABRICATED NEW FLOOR PANEL 252XQF IAW EO B757-5320-9692-H.SDR IPXA2574380Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XFF HAS EDGE DAMAGE IN CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574379Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XHF DELAMINATED IN CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692- H.SDR IPXA2574378Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XEF HAS TWO INSERTS DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574377Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XRF HAS DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574376Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XEF HAS DELAMINATION IN CORNER. FABRICATION FLOORBOARD IAW EO B757-5320-9692.SDR IPXA2574375Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO BAY, FLOORBOARD 232XGF HAS TWO INSERTS BROKEN. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574367Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XJF DAMAGED. FABRICATED NEW FLOOR PANEL AW EO B757-5320-9692-H.SDR IPXA2574366Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XAF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574365Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XJF DAMAGED. FABRICAED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574351Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XLF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574350Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574349Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XPF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574347Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XGF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574333Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 251XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574332Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 251XBF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574331Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 252XNF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574629Floor Panel · gougedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 251XRF HAS SEVERAL GOUGES, DAMAGE TO THE TOP AND BOTTOM SIDE OF PANEL, AND CORRODED FASTENER INSERTS. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574529Floor Support · corrodedINSPECTION TYPE:C, COCKPIT UPPER LEVEL FLOOR STRUCTURE INTERCOSTAL CORRODED, STA 297 -310.5, LBL 60. REMOVED CORROSION ORIGINAL THICKNESS .050 LOSS .007 WITH .043 REMAINING IS OUT OF LIMITS IAW SRM 53-10-15-1A-1. FABRICATED NEW INTERCOSTAL IAW GMM 09-10 AND SDR IPXA2574477Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 252XUF DELAMINATED FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574476Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 251XQF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574392Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 252XSF DAMAGED AT AFT CORNER INBD AND OTBD EDGES DAMAGED AT TOP AFT AREA OF PANEL AND MISSING FASTENERS INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574388Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 252XRF, DAMAGED AT INBD EDGE, AND CORRODED FASTENER INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574283Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XTF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574299Floor Panel · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 251XHF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574262Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 241XGF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574484Panel · damagedINSPECTION TYPE:C, LT TRIM PANEL HAS A DAMAGED FASTENER HOLE BOTH SIDES OF HOLE MARKED. FABRICATED TRIM PANEL IAW DWG 146N5439-3.SDR IPXA2574483Angle · corrodedINSPECTION TYPE:C-CK, RT ANGLE CORRODED IN SEVERAL AREAS STA 1717. FABRICATED ANGLE IAW DWG 146N5439-4.SDR IPXA2574393Floor Panel · damagedINSPECTION TYPE:C-CK, LAVATORY FLOOR PANEL 212XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574334Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD 242XJF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574260Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XCF EDGE DAMAGE, FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574259Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XBF EDGE DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574394Floor Panel · delaminatedINSPECTION TYPE:C, FLT DECK FLOOR PANEL 211XAF DELAMINATED AFT OTBD CORNER FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574277Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XPF DAMAGED ON TOP. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.
Back to Boeing 757-24APF