Boeing 757-24APF

Service difficulty reports · 16,067

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '75724APF'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA11568434Web · corrodedINSPECTION TYPE:C3, COCKPIT FLOOR WEB AT BS 278-310, BBL 18 TO LBL 22, WL200 HAS NUMEROUS AREAS OF CORROSION. REPLACE IAW MFG DWG 148N5810, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-40-08-0G.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568360Shear Web · corrodedINSPECTION TYPE:C3, AREAS OF CORROSION ON SHEAR WEB DOUBLER, AT BS 377 TO 395 LBL 47 TO 52. REPLACED DOUBLER IAW ATS ER 11-03541.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568359Doubler · corrodedINSPECTION TYPE:C3, AREAS OF CORROSION ON SHEAR WEB DOUBLER, AT BS 364 TO 355 LBL 47 TO 51. REPLACED DOUBLER IAW ATS ER 11-03541.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA11568284Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE AND MISSING INSERT BS 1600-1680 LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11568231Floorbeam · corrodedINSPECTION TYPE:C3, CORROSION ON BS 297 FLOORBEAM UPPER FLANGE UPPER SURFACE LBL 20.5 TO RBL 14, WL 208. REPLACED PART IAW SRM 51-40-02-0G.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11568230Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON LOWER SURFACE OF FLOOR SUPPORT AT NUTPLATES BS 310.5 TO BS 297.5, RBL 11, WL 208. R & R SUPPORT IAW DW141N5140, SMR 51-40-02.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568166Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON LOWER SURFACE OF FLOOR SUPPORT AT 4 EA NUTPLATE LOCATIONS BS 310.5-324, LBL 61, WL 208. R & R PART IAW SRM 51-40-02-0G.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568165Floorbeam · corrodedINSPECTION TYPE:C3, CORROSION ON UPPER SURFACE OF FLOOR SUPPORT BS 302.5 LBL 61 WL 208. R & R PART IAW SRM 51-40-02-0GJul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11568153Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON LOWER SURFACE OF FLOOR SUPPORT AT 4 EA NUTPLATE LOCATIONS BS 310.5-324, LBL 61, WL 208. R & R FLOOR SUPPORT.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568152Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON UPPER SURFACE OF FLOOR SUPPORT BS 302.5, LBL 61, WL 208. R & R PART.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568139Floor Panel · corrodedINSPECTION TYPE:C-CHECK, LT FLIGHT DECK COMPARTMENT CORROSION FOUND ON FLOOR DECK FWD, INBD CAPT SEAT TRACK. REMOVED CORROSION AND RESTORED FINISH IAW EA 110839.Jul 9, 2011 · N403UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11568112Stringer Clip · gougedINSPECTION TYPE:C3, STRINGER CLIP IS GOUGED AT STA 377.7, STR 9R. R & R STRINGER CLIP IAW SRM 51-40-02.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA1568091Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE AND MISSING INSERT BS 1600-1680, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568078Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE BS 1540-1600 LBL LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568077Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS DELAMINATION ON LWR SURFACE BS 1420-1540, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568076Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS DAMAGED INSERT BS 1320-1420 LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568021Floor Panel · puncturedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS PUNCTURE ON LWR SURFACE AND DAMAGED INSERT BS 1420-1540, BL 0 TO LBL 25. FABRICATED NEW MCB FLOOR PANEL IAW EO B757-5320-9692-G, SRM 53-00-50-1A 1, SRM 53-00-50-0I 1.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568020Floor Support · corrodedINSPECTION TYPE:C3 CORROSION ON LOWER SURFACE OF FLOOR SUPPORT AT NUTCLIP HOLE BS 302, RBL 0.75, WL 208. R & R FLOOR SUPPORT IAW SRM 51-10-02-0G, 51-40-02-0G, 51-40-05-0G.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1568019Floorboard · delaminatedINSPECTION TYPE:C3, FLOOR PANEL HAS DELAMINATION ON LOWER SURFACE BS 1540-1600, BL0-LBL25. FABRICATED REPLACEMENT FLOOR PANEL A 402H IAW EO B757-5320-9692-G.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568018Floorboard · puncturedINSPECTION TYPE:C3, MCB FLOORBOARD HAS PUNCTURE ON LOWER SURFACE BS 1320-1420, BL 0- LBL 25. FABRICATED REPLACEMENT FLOORBOARD, A 402H IAW EO B757-5320-9692-G.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1567960Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE BS 1200-1320 BL 0 TO LBL 25 FABRICATED PANEL IAW EO. NR B757-5320-9692.Jul 9, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11567891Floor Panel · damagedINSPECTION TYPE:C-CK, FLOOR PANEL NR 231XEF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.Jul 9, 2011 · N431UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11567864Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XBF HAS 2 EDGE DAMAGED. FABRICATED REPLACEMENT PANEL 251XBF IAW EO B757-5320-9692-G.Jul 9, 2011 · N403UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11567822Floor Panel · damagedINSPECTION TYPE:C=CK, MAIN CARGO FLOOR PANEL 242XCF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 242XCF IAW EO B757-5320-9692-G.Jul 9, 2011 · N403UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11568654Web · corrodedINSPECTION TYPE:C3, MCD SHEAR WEB HAS 7 AREAS OF CORROSION ON UPPER SURFACE BS 1680 TO 1682, LBL 4 TO LBL 31, WL 208 (AREAS MARKED). REPAIR IAW ER NR11-03555, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01, SOPM 20-43-03, SOPM 20-41-02.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568653Shear Web · corrodedINSPECTION TYPE:C3, MCD SHEAR WEB HAS 3 AREAS OF CORROSION ON UPPER SURFACE BS 1680 TO 1682.5, RBL 3 TO RBL 48, WL 208 (AREAS MARKED). REPAIR IAW ER1103555, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01, SOPM 20-43-03, SOPM 20-41-02.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA11568652Shear Web · corrodedINSPECTION TYPE:C3, MCD SHEAR WEB HAS 4 AREAS OF CORROSION ON UPPER SURFACE BS 1692 TO BS 1709, LBL 20 TO LBL 52 WL 208 (AREAS MARKED). REPAIR IAW ER 11-03555, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01, SOPM 20-43-03, SOPM 20-41-02.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568644Doubler · corrodedINSPECTION TYPE:C3, MCD SHEAR WEB DOUBLER HAS 3 AREAS OF CORROSION ON UPPER SURFACE AT BS 1682 TO BS 1700.5, LBL 14 TO LBL 20.5, WL 208 (AREAS MARKED). REPAIR IAW ER 11-03540, SRM 51-20-07-0G, 51-40-02-0G, SRM 51-40-08-0G, SOPM 20-43-03, SOPM 20-41-02.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1568499Beam · corrodedINSPECTION TYPE:C3, CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUT PLATE HOLE, BS 1020 TO BS 1040, LBL255. REPAIR IAW ATS ER 11-03559 AND EO B757-5310-43775-A.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA1568464Floorbeam · corrodedINSPECTION TYPE:C3, WHILE WORKING CUSTOMER CARD 942256, FOUND CORROSION ON THE UPPER SURFACE OF THE BS 278 FLOORBEAM, FROM LBL 12 TO LBL 16, WL 200. REPAIR IAW ATS ER 11-03490 AND EO B757-5310-43739-A.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11568447Beam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUTPLATE HOLES; BS 1020 TO 1040, LBL 25. REPAIR IAW ER 11-03559, AND SRM 51-40-02-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568433Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK UPPER FLANGE AT NUTPLATE HOLES; BS 1000 TO BS 1020, LBL 60. REPLACE IAW DWG 144N5016 AND SRM 51-40-02-0G, SRM 51-10-02, SRM 51-40-05-0G, SRM 51-40-08-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11568432Beam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUTPLATE HOLES; BS104 TO 1075, LBL45. REMOVE AND REPLACE IAW SRM 51-10-02 PAR 9 AND ORIGINAL PRODUCTION DWG.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568430Beam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUTPLATE HOLES; BS 980 TO BS 1040, RBL 25. REPAIRED IAW ER 11-03563.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568397Beam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUTPLATE HOLES; BS 990 TO BS 1040, BL 0. REPAIRED IAW ATS ER 11-03521, DATED 08-01-11.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568377Beam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUTPLATE HOLES; BS 990 TO BS 1040, BL 0. REPAIRED IAW ER NR11-03521, DATED 08-01-11.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568357Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK UPPER FLANGE AT NUTPLATE HOLES, BS 1080 TO BS 1180, RBL 25. REPLACED PART IAW SRM 51-40-02-0G, DWG 144N5024.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11568349Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON FLOOR PANEL SUPPORT UPPER SURFACE; BS 1058, BL 0 TO RBL 25 REPLACED FLOOR PANEL SUPPORT (TEE) IAW SRM 53-00-04-1A 1, DWG PL 144N5005, SRM 51-10-02-0G, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11568348Floor Support · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON FLOOR PANEL SUPPORT UPPER SURFACE; BS 1058, BL 0 TO LBL 25. REPLACED FLOOR PANEL SUPPORT (TEE) IAW SRM 53-00-04-1A 1, DWG 144N5005, REV A, SRM 51-10-02-0G, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568347Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK UPPER FLANGE AT NUTPLATE HOLES; BS 1075 TO BS 1144, LBL 25. REPLACE SEAT TRACK.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11568346Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK UPPER FLANGE AT NUTPLATE HOLE; BS 1179, LBL 45. REPLACED TRACK.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11568324Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON FLOORBEAM UPPER SURFACE; BS 1056, LBL 25 TO LBL 45. REMOVED, FABRICATED AND INSTALLED NEW FLOORBEAM IAW SRM 51-40-02, SRM 51-21-10-7, SOPM 20-50-01, SRM 51-20-01-0G, SRM 51-10-02-0G DWG 144N5084.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11568323Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK UPPER FLANGE SUPPORT CHANNEL AT NUTPLATE HOLES; BS 1040 TO BS 1080, BL 0. REPLACED SUPPORT CHANNEL IAW DWG 144N8031, SRM 51-40-02-0G, AND SRM 51-40-05-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1568290Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1681 TO BS 1720 BL 0 TO LBL 55 HAS SEVERAL DAMAGED INSERTS AND DELAMINATION ON LWR SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G, DATED 04-15-2009.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1568289Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1681 TO BS 1720 BL 0 TO RBL 55 HAS DELAMINATION ON LWR SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G, DATED 040-15-2009.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11568198Beam · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK, CORROSION ON LONGITUDINAL BEAM UPPER FLANGE AT NUTPLATE HOLES BS 1040 TO BS 1075, LBL 25. REMOVED AND REPLACED LONGITUDINAL BEAM IAW SRM 51-40-02-0G, 51-40-05-0G, 51-40-08-0G, AND DWG 144N8017.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA11568151Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK UPPER FLANGE AT NUT PLATE HOLES: BS 1175, BL 0. REMOVED, FABRICATED AND INSTALLED NEW SEAT TRACK IAW SRM 51-10-02-0G SRM 52-00-52-1A1, SRM 51-40-02-0G, SRM 51-40-05-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11568111Support · crackedINSPECTION TYPE:C3, FCB MBA ASSY PN 81658-10, HAS 2EA CRACKED SUPPORTS. REPLACED SUPPORTS IAW SRM 51-40-02-0G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11568110Stringer Clip · damagedINSPECTION TYPE:C3, BS 1200 STR-10R STR CLIP HAS MECHANICAL DAMAGE BEYOND LIMITS. R & R STR CLIP IAW SRM 51-40-02.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA1568044Floor Panel · brokenINSPECTION TYPE:C3, MAIN CARGO DECK: FLOOR PANEL HAS BROKEN INSERTS: BS 1058-1100, LBL 25-45. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.Jul 8, 2011 · N401UP · Boeing 75724APF · Fuselage Floor Panel
Back to Boeing 757-24APF