Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA11566548Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 252XUF HAS 2 DAMAGED INSERTS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566628Frame Splice · gougedINSPECTION TYPE:C, SCREW STRIKE ON THE BS 620 FRAME SPLICE DOUBLER, INBD FLANGE, BETWEEN STR 8-9L. R & R FRAME SPLICE DOUBLER IAW SRM 51-40-02-0G.SDR IPXA1567046Floorbeam · corrodedINSPECTION TYPE:C3, CORROSION AROUND NUTPLATE HOLES ON FLOORBEAM, STA 879, LBL 45-54, WL 208. REPAIR IAW EO B757-5310-42979-A AND ATS ER 11-02744.SDR IPXA11566847Seat Track · corrodedINSPECTION TYPE:C3, CORROSION AROUND NUTPLATE HOLES ON SEAT TRACK, STA 879-900 LBL 45, WL 208. REPLACED SEAT TRACK IAW SRM 53-30-52-0I 1, SRM 51-40-02-0G, DWG 143N5405 REV-, SRM 51-40-08-0G, SRM 51-40-05-0G, & SRM 51-20-01-0G.SDR IPXA11566787Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK: CORROSION ON SEAT TRACK AT BS 440, RBL 46, WL 208. R & R CORRODED SEAT TRACK SECTION IAW SRM 51-40-02-08, SRM 51-10-02-0G, SRM 53-00-52-1A, SRM 53-10-52-2R DWG PL143N5273, DWG PL1435276.SDR IPXA11566775Shear Web · corrodedINSPECTION TYPE:C3, CORROSION ON SHEAR WEB AT STATION 440-460, LBL 45-65, 3 AREAS. (MARKED) REPAIRED IAW ER 11-02760.SDR IPXA11566774Shear Web · corrodedINSPECTION TYPE:C3, CORROSION ON SHEAR WEB, AT STATION 480-560, LBL 45-65, SEVERAL AREAS. (MARKED) REPAIRED IAW ER 11-02760.SDR IPXA11566773Shear Web · corrodedINSPECTION TYPE:C3, CORROSION ON SHEAR WEB, AT STA 560-620, LBL 45-65, SEVERAL AREAS. (MARKED) REPAIRED IAW ER 11-02760.SDR IPXA11566753Seat Track · corrodedINSPECTION TYPE:C3, CORROSION AROUND NUTPLATE HOLES ON SEAT TRACK, STA 879-900 LBL 45, WL 208. REPLACED SEAT TRACK IAW SRM 53-30-52-0I1, SRM 51-40-02-0G, DWG 143N5405 REV, SRM 51-40-08-0G, SRM 51-40-05-0G, SRM 51-20-01-0G.SDR IPXA11566752Seat Track · damagedINSPECTION TYPE:C3, SEAT TRACK IS DAMAGED AT STA 872, LBL 25. REPLACED SEAT TRACK BS 780 TO BS 880, LBL 25, IAW SRM 53-00-52-1A1, SRM 51-40-02-0G, SRM 51-40-08-0G, SRM 51-40-05-0G, SOPM 20-41-02, DWG 143N5274 REV.SDR IPXA11566746Frame · dentedINSPECTION TYPE:C3, FRAME IS DENTED, INBD FLANGE, STA 580, WL 213, BETWEEN STR 16-17R. REPLACED BS 580, RT FRAME SECTION IAW DWG 143N1008, 143N1024, ER 11-02814 DATED 05-17-11, SRM 51-40-02-0G, AND SRM 51-40-05-0G.SDR IPXA11566599Support Fitting · crackedINSPECTION TYPE:C3, INTERIOR, STR 5L TO 9G, SUPPORT CLIP IS CRACKED AT BS 330. REPLACED CLIP IAW DWG 141N8226, 141N8206, AND SRM 51-40-02-0G.SDR IPXA11566595Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 560-620, BL 0 - LBL 25, FLOOR PANEL REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566594Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 560-620, BL 0 - RBL 25 FLOOR PANEL REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566593Floor Panel · damagedINSPECTION TYPE:C3, MCB BS 333-440, BL 0 - RBL 25, WL 208, FLOORBOARD HAS EDGE DAMAGE REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566578Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 620-720, LBL 45-65. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566552Floor Panel · delaminatedINSPECTION TYPE:C3, MAIN CARGO DECK; FLOOR PANEL FROM BS 480-560, BL 0 - RBL 25, FWD OTBD CORNER IS DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566551Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL AT STA 1236, LBL 45 FWD EDGE DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566515Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 720-780, RBL 25-45. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566514Frame · damagedINSPECTION TYPE:C3, SCREW STRIKE ON INNER FLANGE OF FRAME, STA 440, STR 13R. REPAIRED BS 440 FRAME BETWEEN STR 10R AND 11R TO STR 14R IAW SRM 53-30-07-0I 1, SRM 53-00-07-1A 1, SRM 53-00-07-2R 1, SRM 51-20-01-0G, SRM 51-40-09-0G, SRM 51-40-02-0G, SRM 51-40-SDR IPXA11566513Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 333-440, BL 0-RBL 25, WL 208, FLOORBOARD HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566512Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 333-440, BL 0-LBL 25, WL 208, HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566511Floor Panel · damagedINSPECTION TYPE:C3, MCB BS 333-440, RBL 45-62, WL 208, FLOORBOARD HAS EDGE DAMAGE. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566501Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO DECK: FLOOR PANEL FROM BS 480-560, BL 0-RBL 25, FWD OTBD CORNER IS DELAMINATED. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566500Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE AND 1 EA INSERT MISSING, STA 440-480, LBL 45-65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566499Floorboard · damagedINSPECTION TYPE:C3, MCB FLOORBOARD BS 333-440, WL 208, LBL 45-LBL 62 IS PUNCTURED AND HAS DAMAGES ON UPPER SURFACE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566498Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 1300, RBL 45 TO 62 IS DAMAGED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566497Floorboard · damagedINSPECTION TYPE:C3, BS 1680-1720, RBL 0-65, WL 208 FLOORBOARD MISSING INSERT. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566496Floor Panel · damagedINSPECTION TYPE:C3, BS 1680-1720, LBL 0-65, WL 208, FLOOR PANEL MISSING INSERT. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566495Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL AT STA 1600 TO 1681, LBL 45 TO 65 AFT OTBD CORNER DAMAGED. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566494Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 1320, LBL45 TO 62 HAS MECHANICAL DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566493Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 480-560, LBL 45-65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566492Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 560-620, LBL 45-65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566491Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 480-560, LBL 0-25. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566490Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 480-560, LBL 25-LBL 45. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566489Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 440-480, LBL 25-LBL 45. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566488Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 560-620, BL 0-LBL 25. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566487Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 560-620, BL0-RBL25. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566486Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 440-480, LBL 0-25. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566485Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 620-720, LBL 25-45. REPLACED IAW EO B757-5320-9692-G.SDR IPXA11566482Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 620-720, LBL 45-65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566481Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 720-780, RBL 45-65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566480Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 720, LBL 25-45. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566477Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 560-620, LBL 25-45. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566474Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 620-720, RBL 45-65. REPLACED FLOOR PANEL IAW EO B75705320-9692-G.SDR IPXA11566473Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 820-720, RBL 0-25. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566471Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 720-820, LBL 0-25. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566470Floor Panel · damagedINSPECTION TYPE:C3 FLOOR PANEL HAS EDGE DAMAGE, STA 820-880, RBL 0-25. REPLACED FLOOR PANEL IAW EO B75705320-9692-G.SDR IPXA11566468Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 720-820, RBL 0-25. REPLACED FLOOR PANEL IAW EO B75705320-9692-G.SDR IPXA11566467Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE, STA 620-720, RBL 25-45. REPLACED IAW EO B75705320-9692-G.
Back to Boeing 757-24APF