SDR IPXA10562362Stringer Clip · damagedINSPECTION TYPE:C3, STR 4R, STR CLIP HAS MECHANICAL DAMAGE ON FWD FACE AT BS 395.7 (MARKED). REPLACED STR CLIP IAW SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G, DWG 141N0500.SDR IPXA10562352Skin · dentedINSPECTION TYPE:C3, LT WING NR 3 SLAT T/E WEDGE LOWER SURFACE SKIN HAS DENT ABOUT INBD MAIN TRACK. REPAIRED NR3 SLAT T/E WEDGE IAW SRM 51-70-10-2R-4. REPAIR 4 AND SRM 51-70-10-2R, REPAIR GENERAL.SDR IPXA10562771Skin Panel · gougedINSPECTION TYPE:C3, L/W INBD MAIN FLAP L/E EXTERNAL SURFACE IS GOUGED JUST AFT OF TRUNNION FAIRING DOOR. R & R FLAP L/E SKIN PANEL IAW SRM 51-40-02-0G & SOPM 20-50-01.SDR IPXA10562453Support · chafedINSPECTION TYPE:C3, NR1 ENGINE STRUT FAIRING SUPPORT HAS CHAFING AT NAC STA 149.5 ON RT SIDE. REPLACED IAW SRM 51-40-02-0G.SDR IPXA10562388Bracket · crackedINSP TYPE:C3, NR1 ENGINE STRUT HAS CRACKED BRACKET JUST INBD OF PANEL 435AR CUTOUT FWD LWR CORNER. R & R BRACKET IAW SRM 51-40-02.SDR IPXA10562307Floor Panel · damagedINSPECTION TYPE:SP, FABRICATE NEW FLOOR PANEL 211XAF TO ACCOMODATE NEW FLOOR STRUCTURE. FABRICATED NEW FLOOR PANEL 211XAF IAW EO.SDR IPXA10562810Stop Fitting · gougedINSPECTION TYPE:C3, MCD FWD UPPER STOP FITTING IS GOUGD AT BS 480, S-6L. R & R STOP FITTING IAW B757-5310-15194-D.SDR IPXA10562809Stop Fitting · gougedINSPECTION TYPE:C3, MCD AFT UPPER STOP FITTING IS GOUGED AT BS 620, S-6L. R & R STOP FITTING IAW EO B757-5310-15194-D.SDR IPXA10562738Skin · damagedINSPECTION TYPE:C3, EXTERNAL FUSELAGE SKIN MCD CUTOUT HAS 3 EA DAMAGED AREAS AT BS 620 BETWEEN S-13L AND S-14L. REPAIRED IAW EO B757-5330-39692-A AND ER 10-4384.SDR IPXA10562441Angle · chafedINSPECTION TYPE:C3, NR 1 ENGINE LT THRUST REVERSER COWL LOWER BIFURCATION OUTER FAIRING LOWER ANGLE AND WEB ARE CHAFED. R & R IAW SRM 54-31-02-1A1; SRM 51-10-02-0G; SRM 51-40-05-0G; AMM 78-31-01-8.SDR IPXA10562305Shear Web · corrodedINSPECTION TYPE:SP, CORROSION ON SHEAR WEB UPPER SURFACE (2 EA SITES) AT BS 326, LBL 42 & LBL 38. REPAIRED IAW ATS ER NR10-4222 AND EO B757-5310-39445-A.SDR IPXA10562304Shear Web · corrodedINSP TYPE:SP, CORROSION ON SHEAR WEB UPPER SURFACE (2 EA SITES) AT BS 326, LBL 32 & LBL 28. REPAIRED IAW ATS ER NR10-4222 AND EO B757-5310-39445-A.SDR IPXA10562279Gauge · malfunctionedAPPROX 30 MIN INTO FLIGHT, CREW NOTICED AN EXCEEDENCE OF 650 ON THE R EGT GAUGE. UNKOWN OF WHEN IT OCCURRED OR FOR HOW LONG. ENGINE OPERATES NORMALLY. NO OTHER ABNORMALITIES NOTED. IAW MM 72-00-00-6 AND MM 71-00-00-5, ALL REQUIRED CHECKS PERFORMED ON RT ENG SDR IPXA10562242Shear Web · corrodedINSPECTION TYPE:C2, CORROSION AND BARE METAL ON SHEAR WEB BS 558-660 LBL 45-65. REPAIR IAW ER 10-3672.SDR IPXA10562185Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN CARGO FLOOR PANEL BS 335 TO 440, BL 0 TO LBL 25 HAS DELAM ON UPPER SURFACE. FABRICATED NEW PANEL IAW B757-5320-9692G.SDR IPXA10562152Fire Warning · false activationEICAS STATUS MSG: R ENG FIRE LP 1 DISPLAYED. ACCOMPLISHED VISUAL INSP OF FIRE DETECTION LOOPS. NO DEFECTS NOTED. ACCOMPLISHED FIM 26-11-00, FIG 103, SYS BITE CHECKS NORMAL. RESEATED & CLEANED AFLOTS CARD NR 2 IAW AMM 26-10-01-4. OPS CHECKS GOOD IAW BITE TSDR IPXA10562130Acm · seizedIN FLIGHT, DIVERTED DUE TO SMOKE IN COCKPIT, RAN CHECKLIST SMOKE STOPPED. ELECTRIC SMELL AND PACK NOISE SURGING CONTINUED. FOUND LT ACM SEIZED. R & R LT ACM IAW AMM 21-51- 03-4. PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSP IAW AMM 05-51-56-2. OPS CHECK SDR IPXA10562055Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS1500, STR 25-26 RT. REPAIRED IAW SRM 53-00-07-2R5.SDR IPXA10562054Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS 1480, STR 23-24 LT. REPAIRED IAW SRM53-00-07-2R5.SDR IPXA10562053Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS 1500 STR 23-24 LT REPAIRED IAW SRM 53-00-02-1A, 53-00-07-2R5.SDR IPXA10562052Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS 1340 STR 25-26 LT. REPAIRED IAW SRM53-00-07-2R5.SDR IPXA10562644Floorboard · damagedINSPECTION TYPE:C2 MAIN CARGO FLOOR BOARD AT BS 480 TO 560, BL0 TO RBL25 IS BROKEN AND MISSING INSERTS. REPLACED IAW EO B757-5320-9692.SDR IPXA10562063Floorboard · damagedINSPECTION TYPE:C2, FLOORBOARD AT BS 480 TO 560, BL 0 TO RBL 25 IS BROKEN REPLACED IAW EO B757-5320-4692.SDR IPXA10562252Seat Track · corrodedINSPECTION TYPE:C2, REPLACED SEAT TRACK FROM STA 440 TO 680 LBL 45, REPLACED IAW ER NR 10-3927, DATED 26AUG10.SDR IPXA10562122Floor Panel · corrodedINSPECTION TYPE:C2, FOR RCD ONLY: AFT DECK PLATE CORROSION AT BS 1699, LBL 20 - 23. REPAIRED IAW ATS ER 10-3731, DATED 8-18-10.SDR IPXA10562121Floor Panel · corrodedINSPECTION TYPE:C2, FOR RCD ONLY: AFT DECK PLATE CORROSION AT BS 1715, RBL 2-9. REPAIRED IAW ATS ER10-3731, DATED 8-18-10.SDR IPXA10562339Stringer · damagedINSPECTION TYPE:C3, WHILE WORKING FRAME REPAIR FOUND A DOUBLE HOLE AT STR 15L, BS 940 IN THE STRINGER VERTICAL FLANGE. REPAIRED IAW ATS ER 10-4124, DATED 8-31-10.SDR IPXA10562167Support Bracket · damagedINSPECTION TYPE:C2, BS 880, BL 0, WL 208, EXPANSION LINK SUPPORT BRACKET ON AFT SIDE OF FLOORBEAM BUSHING HOLES DAMAGED. REPLACED CHANNEL (SUPPORT BRACKET) IAW SRM 51-40-05-0G, SRM 51-20-01-0G, DWG 143N5447, SOPM 20-50-20, DWG 143N5444.SDR IPXA10562166Support · gougedINSPECTION TYPE:C2, ACB FLOOR TO SIDEWALL SUPPORT GOUGED OR UPPER SURFACE AT BS 1598, WL 156, RBL 19. REMOVED, FABRICATED, INSTALLED REPLACEMENT SEGMENT.SDR IPXA10562151Floorboard · damagedINSPECTION TYPE:C2 FLOORBOARD AT STA 333 TO 440, LBL 45-60. REQUIRES STEP CUT FOR SHEAR WEB REPAIR. FABRICATED REPLACEMENT FLOORBOARD IAW B757-5320-9692-G.SDR IPXA10562150Floorboard · damagedINSPECTION TYPE:C2 FLOORBOARD AT STA 333-440, LBL 25-45 REQUIRES A STEP CUT FOR SHEAR WEB REPAIR. APPLIED STEP CUT TO FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562112Strap · damagedINSPECTION TYPE:C2 9G WALL UPPER TENSION STRAP AT STR 3R IS DOUBLED DRILLED. REPAIRED IAW ATS ER10-3692, DATED 8-19-10.SDR IPXA10562111Strap · damagedINSPECTION TYPE:C2, 9G WALL UPPER TENSION STRAP AT STR 2R IS DOUBLED DRILLED. REPAIRED IAW ATS ER10-3692, DATED 8-19-10.SDR IPXA10562110Strap · damagedINSPECTION TYPE:C2, 9G WALL UPPER TENSION STRAP AT STR 2L IS DOUBLED DRILLED. REPAIRED IAW ATS ER 10-3692, DATED 8-19-10.SDR IPXA10562138Shear Web · damagedINSPECTION TYPE:C2, SHEAR WEB HAS ELONGATED HOLE AT BS 375, RBL 50, WL 207.5. REPAIRED IAW ATS ER 10-3796, DATED 8-20-10.SDR IPXA10562128Shear Web · damagedINSPECTION TYPE:C2, SHEAR WEB HAS ELONGATED HOLE AT BS 360, RBL 61, WL 207.5 REPAIRED IAW ATS ER 10-3796.SDR IPXA0562024Skin · dented(3 EA) DENTS ON RT INBD FLAP LOWER SKIN OTBD T/E. REPAIRED DAMAGES IAW EO NR B757-5750-39207-A AND SRM 51-70-10-2R.SDR IPXA10562046Attach Angle · crackedINSPECTION TYPE:C3, INTERCOASTAL UPPER ATTACH ANGLE AT BS 1200-1220, LBL45, WL208, CRACKED AT FASTENER HOLE. REMOVED, FABRICATED REPLACEMENT, INSTALLED REPLACEMENT ANGLE SRM51-40-02-0G.SDR IPXA0561943Floor Support · corrodedINSPECTION TYPE:C3, FLOOR SUPPORT CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND INSTALLED IAW SRM 51-40-02-0G DOC 141N5810.SDR IPXA0561939Stringer Clip · crackedINSPECTION TYPE:C3, STR CLIP CRACKED. REMOVED, FABRICATED, AND INSTALLED IAW DWG 140N2001-1, SRM 51-21-04-7, SRM 51-40-02-OG.SDR IPXA0561933Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STRINGER CLIP REMOVED, FABRICATED AND INSTALLED IAW DWG 140N2001-1 AND SRM 51-40-05-OG.SDR IPXA0561932Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STRINGER CLIP, BS 1440, STR 8 LT R & R AFTER FABRICATION IAW DWG 140N2001-1, SRM 51-40-03-OG.SDR IPXA0561931Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STRINGER CLIP. REMOVED CRACKED CLIP, FABRICATED NEW AND INSTALLED IAW DWG 140N2001-1, SRM 51-40-03-OG.SDR IPXA0561930Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STRINGER CLIP, BS 1380 STR 10 LT. REMOVED, FABRICATED AND INSTALLED STRINGER CLIP IAW 140N2001-1, SRM 51-40-05-OG.SDR IPXA0561929Stringer Clip · crackedINSPECTION TYPE:C3, STR CLIP CRACKED BS 1320 STR 14 RT. REMOVED, FABRICATED AND REPLACED IAW SRM 51-40-05-OG DWG 146N1007.SDR IPXA0561926Stringer Clip · crackedINSPECTION TYPE:C3, FUSELAGE STR CRACKED STA 1100, S 7 RT REMOVED, FABRICATED AND INSTALLED STR CLIP IAW SRM 51-40-05-OG AND DWG 144N1109.SDR IPXA0561958Skin · punctured0.80 HOLE PUNCTURED THROUGH ACFT SKIN BY AIRSTAIR AT APPROX STA 213, S STR 23L CUTOUT DAMAGE IAW SRM 53-00-00-01, THIS REPAIR IS CLASSIFIED AS A MAJO R REPAIR IAW GMM 03.43.01.04. TRANSFERRED TO NRC 34 6743SDR IPXA10562340Stringer · damagedINSPECTION TYPE:C3, WHILE WORKING CUSTOMER CARD 873323, FOUND DOUBLE HOLE COMMON TO STR 10R AT BS 1140. REPAIRED IAW ER 10-4125.SDR IPXA10562247Intercostal · puncturedINSPECTION TYPE:C2, FOUND PUNCTURE IN INTERCOSTAL, BS 502, LBL 45, WL 206. REPLACED IAW ATS ER 10-4153.SDR IPXA10562246Intercostal · puncturedINSPECTION TYPE:C2, FOUND PUNCTURE INTERCOSTAL, BS 457, WL 206. REPLACED INTERCOSTAL IAW ER 10-4153 & DWG 140N2054.
Back to Boeing 757-24APF