SDR IPXA10561552Floorboard · puncturedINSPECTION TYPE:C3, MAIN CABIN FLOORBOARD IS PUNCTURED BS 620-720, LBL 0 TO 25. REMOVED AND FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A1.Aug 3, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561551Floorboard · damagedINSPECTION TYPE:C3, MCB FLOORBOARD IS DAMAGED AT BS 1540-1600, LBL 25-45, WL 208. FABRICATED REPLACEMENT FLOORBOARD IAW EO NR B757-5320-9692-G AND B757-5100-33281-B.Aug 3, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561550Floor Panel · delaminatedINSPECTION TYPE:C3, MAIN CABIN FLOORBOARD IS DELAMINATED, BS 560 TO 620, LBL 0 TO 25. REMOVED AND FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G AND SRM 53-00-50-1A1.Aug 3, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561534Spacer · corrodedINSPECTION TYPE:C2, NR 1 ENGINE PYLON INBD SKATE ANGLE, BACKING ANGLE, FWD SPACER AT NAC STA 205 IS CORRODED. REPLACED SPACER IAW SRM 51-40-02-0G, SRM 51-10-02-0G STEP 8, SRM 51-40-05-0G, SRM 51-40-08-0G.Aug 3, 2010 · N430UP · Boeing 75724APF · Nacelle/Pylon Miscellaneous StructureSDR IPXA10561524Nut · leakingIAS DISAGREE EICAS MSG DISPLAYED. NRC 869387 TROUBLESHOT IAS DISAGREE EICAS MSG IAW FIM 34-12-00 IAW FIG 107, BLK 1& 13, FIM 34-11-00 PG1 FIG104, PERFORMED FULL RANGE PITOT SYS, FND FO'S PITOT SYS LEAKING. APPLIED SNOOP TO FO'S PLUMBING FITTINGS & FND NUT AT Aug 3, 2010 · N412UP · Boeing 75724APF · Pitot/Static SystemSDR IPXA10561496Battery Pack · inoperativeEMERGENCY EXIT LIGHTS GO OFF AFTER 5 SEC. R & R BATTERY PACK IAW AMM 33-51-07-2. OPS CK NORMAL.Aug 3, 2010 · N456UP · Boeing 75724APF · Emergency LightingSDR IPXA10561482Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL 820-879, LBL 45-61 CORNER DELAMINATED. FABRICATED NEW MAIN DECK FLOOR PANEL BS 820-879, LBL 45-60 IAW EO B757-5320-9692G.Aug 3, 2010 · N429UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562693Support · crackedINSPECTION TYPE:C3, FWD CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT IS CRACKED, AT PREVIOUS REPAIR CUTOUT STA 729 LBL 20. REMOVED CRACKED SUPPORT, INSTALLED NEW SUPPORT IAW SRM 51-40-02.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562342Frame · gougedINSPECTION TYPE:C3, UPPER LOBE FRAME IB FLANGE HAS GOUGE DAMAGE WITHIN A DENTED AREA, BS 345 BETWEEN STR 9R-STR 10R, (MARKED). REPAIRED IAW ATS ER 10-3862, DATED 9-1-10.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10562337Frame · dentedINSPECTION TYPE:C3, FWD CARGO COMPARTMENT: BS 660 FRAME INNER FLANGE IS DENTED, STA 666, STR 24R. REPAIRED IAW ATS ER 10-3928, DATED 9-1-10.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10562336Panel · chafedINSPECTION TYPE:C3, FUSELAGE EXTERNAL SKIN IS CHAFED AT BS 1857-1862.5 BELOW LT HORIZONTAL STABALIZER. REPAIR IAW ER 10-3789.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA10562329Support · corrodedINSPECTION TYPE:C2, FLOOR TO SIDEWALL IN AFT CARGO BAY FROM BS 1200-1310 AT RBL 21 IS CORRODED. REPLACED IAW SRM 53-00-53-1A1, 51-40-02.Aug 2, 2010 · N430UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562308Stringer Clip · damagedINSPECTION TYPE:C3, FUSELAGE INTERIOR RT, STRINGER CLIP AT STA 1140, S-10 HAS SCRIBE MARK. REPLACED STRINGER CLIP IAW SRM 51-40-02-0G, DWG 144N1111, DWG 140N2001 PL, AND SRM 51-40-05-0G.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA10562205Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STRINGER CLIP, BS 1440, STR 10 LT. REPLACED IAW ER 10-4005.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA10562116Frame · dentedINSPECTION TYPE:C3, UPPER LOBE FRAME HAS GOUGE DAMAGE WITHIN A DENTED AREA, BS345, BETWEEN STR 9-10L. MARKED REPAIRED IAW ATS ER 10-3854.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10562061Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STRINGER CLIP BS 1280, STR 10 LT. R & R STRINGER CLIP IAW SRM 51-40-02-0G.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA10562056Fitting · corrodedINSPECTION TYPE:C3, BS 297, LBL-50, WL 208 COCKPIT UPPER FLOOR STRUCTURE HAS CORROSION AT SEAT STANCHION BASE PLATE. R & R SEAT STANCHION ATTACH FITTING IAW SRM 51-40-02-0G.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA0561962Support · corrodedINSPECTION TYPE:C2, FLOOR TO SIDWALL IN AFT CARGO BAY FROM BS 1200-1310 AT RBL 21 IS CORRODED. REPLACED IAW SRM 53-00-53-1A1, 51-40-02.Aug 2, 2010 · N430UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA0561941Stringer Clip · crackedINSPECTION TYPE:C3, CRACKED STR CLIP, BS 1440, STR 9LT. REMOVED FABRICATED AND INSTALLED REPLACEMENT CLIP IAW SRM.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA10561575Shear Web · corrodedINSPECTION TYPE:C3, BS-366, RBL-62,WL-208, SHEAR WEB HAS CORROSION (MARKED) BLENDED AND RESTORED FINISHIAW EO B757-5310-38276-B.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10561548Floor Panel · crackedINSPECTION TYPE:SPV, FLOOR PANEL 221XCF HAS A CRACKED INBD FWD CORNER. REPAIRED IAW EO B757-5320-9692-G.Aug 2, 2010 · N409UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561536Shear Web · corrodedINSPECTION TYPE:SP, CORROSION ON SHEAR WEB AT BS 416.5-LBL49 WL208 REPAIRED IAW ATS ER 10-3764 AND EO B757-5310-39022-A.Aug 2, 2010 · N409UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10561520Floorboard · damagedINSPECTION TYPE:C3, BS 880-900, WL 208, LBL 25-45 FLOORBOARD HAS EDGE DAMAGE AND IS DENTED. FABRICATED REPLACEMENT FLOOR PANEL.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561519Floor Panel · damagedINSPECTION TYPE:C3, FUSELAGE INTERIOR LT, FLOOR PANEL AT LBL 45 TO LBL 60, STA 1020 TO STA 1060 FWD INBD CORNER DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561518Floor Panel · brokenINSPECTION TYPE:C3, FUSELAGE INTERIOR LT, FLOOR PANEL AT LBL 45 TO LBL 60, STA 1020 TO STA 900 IS BROKEN IN CTR FABRICATED REPLACEMENT FLOOR PANEL.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561517Floor Panel · damagedINSPECTION TYPE:C3, FUSELAGE INTERIOR RT, FLOOR PANEL AT RBL 25 TO RBL 45 STA 1060 TO STA 1100 INSERT MISSING IN CTR OF PANEL. FABRICATED REPLACEMENT FLOOR PANEL.Aug 2, 2010 · N423UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562350Frame · dentedINSPECTION TYPE:C3, DAMAGED ISOLATOR WITH POSSIBLE DENT TO FRAME IN MCB BS 540, BETWEEN S-5R AND S-6R. REPAIRED IAW ATS ER10-3945.Aug 1, 2010 · N423UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10562291Frame · damagedINSPECTION TYPE:C3, MCB FRAME INBD FLANGE HAS A MECHANICAL DAMAGE AT BS 900 BETWEEN S-15R AND S-16R. REPAIR IAW ATS ER 10-4009.Aug 1, 2010 · N423UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10562123Floor Support · gougedINSPECTION TYPE:C2, MAIN CARGO BAY LONGNITUDINAL FLOORBEAM UPPER CHORD HAS A GOUGED AREA AT BS 1020 TO 1022, LBL 2, WL 208. REPAIRED IAW ATS ER 10-3740.Aug 1, 2010 · N430UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562030Panel · puncturedINSPECTION TYPE:C3, RT HORIZ STAB LOWER INTERNAL SKIN IS PUNCTURED 6 INCHES FROM AUX SPAR BELOW OTBD LOGO LIGHT. REPAIRED RT HORIZ LOWER PANEL INNER SURFACE SKIN IAW ER 10-3874.Jul 31, 2010 · N423UP · Boeing 75724APF · Horizontal Stabilizer, Plate/SkinSDR IPXA10561440Floor Panel · crackedINSP TYPE: SPV FLOOR PANEL 222XBF CRACKED. REPAIRED IAW EO B757-5320-9692G.Jul 31, 2010 · N451UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562338Skin · chafedINSPECTION TYPE:C3, FUSE EXTERNAL SKIN IS CHAFED AT BS 1862.7-1871.7 BELOW LT HORZ STAB. REPAIR IAW ER 10-3788, DATED 8-31-10.Jul 30, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA10562256Skin · chafedINSPECTION TYPE:C3, FUSE EXTERNAL SKIN IS CHAFED AT BS 1862.7 - 1871.7 BELOW RT HORIZONTAL STAB. REPAIR IAW ER 10-3787.Jul 30, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA10562168Floorbeam · corrodedINSPECTION TYPE:C2, FLOORBEAM IS CORRODED, BS 879, WL 208, LBL 4. REPAIRED IAW ER NR10-3741, DATED 23AUG10 AND EO NR B757-5310-39352-A, DATED 8/25/10.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562104Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN CABIN FLOOR PANEL DELAMINATED ON LOWER SURFACE, BS 458, LBL 63, WL 208. FABRICATED NEW MAIN CABIN FLOOR PANEL IAW B757-5320-9692 G, B757-5100-33281-B AND SRM 53-00-50-2R1.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562043Skin Panel · damagedINSPECTION TYPE:C3, EXTERNAL FUSELAGE SKIN SURFACE HAS MECHANICAL DAMAGE AT BS 1534-1564 STR - 22R. REPAIRED IAW ATS ER10-3824 DATED 8/19/10 AND EO B757-5330-39251-A, DATED 8-20-10.Jul 30, 2010 · N423UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA0561973Seat Track · corrodedINSPECTION TYPE:C2, SEAT TRACK IS CORRODED BS 890, WL 208, LBL 25. REPLACED IAW DWG 143N5481-4, SRM 53-30-52.0I1, 53-30-52-1A1.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10561888Floorbeam · corrodedINSPECTION TYPE:C2, FLOORBEAM UPPER FLANGE IS CORRODED AT NUTPLATE LOCATIONS, BS 620, BETWEEN LBL 25 AND LBL 45, WL 208. REPAIRED IAW ER 10-3743.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10561568Floor Panel · crushedINSPECTION TYPE:C2, FLOOR PANEL CRUSHED ON OTBD UPPER EDGE. BS 523. RBL 45, WL 208. FABRICATED NEW FLOOR PANEL IAW SRM 53-00-50-1A-1.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561567Floor Panel · crushedINSPECTION TYPE:C2, FLOOR PANEL CRUSHED ON INBD UPPER EDGE BS 510, LBL 26, WL 208. FABRICATED NEW FLOOR PANEL IAW SRM 53-00-50-1A-1.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561556Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL IS DAMAGED ON INBD EDGE, BS 728, RBL 25, WL208. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 30, 2010 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561555Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL OTBD EDGE IS DAMAGED, B.S 777 LBL 45, WL 208 FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 30, 2010 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561554Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL INBD LOWER EDGE IS DAMAGED, B/S 620 B/S 720, LBL 25, WL208. FABRICATED REPLACEMENT FLOOR PANEL IAW UPS EO B757-5320-9692.Jul 30, 2010 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561545Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL DAMAGED ON AFT EDGE, BS 820, RBL 18, WL 208 REPLACED PANEL IAW SRM 53-00-50-1A1 TABLE I, UPS EO B757-5320-9692-G, AND EO B757-5100-33281-B.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561471Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL IS DAMAGED IN MULTIPLE LOCATIONS ON OTBD EDGE BS 620-740, RBL 61, WL 208. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-B.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561470Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL UPPER SURFACE IS DAMAGED IN MULTIPLE AREAS RBL 25-45, BS 560-620, WL 208. REPLACE IAW EO B757-5320-9692-G, EO B757-5100-33281B.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561469Floorboard · puncturedINSPECTION TYPE:C1, FLOOR PANEL PUNCTURED ON UPPER INBD EDGE BS612, RBL 24, WL 208. REPLACED IAW EO B757-5320-9692 G, B757-5100-33281-B.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561468Floor Panel · damagedINSP TYPE:C2, FLOOR PANEL DAMAGED AT AFT CORNER B/S 720, RBL 25, WL 208. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561467Floor Panel · crushedINSPECTION TYPE:C2, FLOOR PANEL CRUSHED ON INBD FLANGE UPPER EDGE, BS 489, RBL 46, WL 208. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Jul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561414Floor Panel · puncturedINSPECTION TYPE:C2, FLOOR PANEL PUNCTURED ON INBD UPPER EDGE BS 510, LBL 2, WL 208. FABRICATED FLOOR PANEL FROM A402H TEKLAN IAW EO B757-5320-9692-GJul 30, 2010 · N430UP · Boeing 75724APF · Fuselage Floor Panel
Back to Boeing 757-24APF