Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10560513Unknown · odorON ARRIVAL INTO SJO DESCENDING FROM 15000 FT, ACFT ENTERED A CLOUD AND THE CABIN FILLED WITH A STRONG SMELL OF SULFUR. EXITED THE CLOUD IN LESS THAN 30 SECS AND THE ODOR CLEARED CLOUD ASSOCIATED. PERFORMED INSP OF ENGINES INLET AND EXHAUST, FAN BLADES, WINGSSDR IPXA10560480Structure · damagedAPU INNER COMP CHORD DAMAGED BS1896.2 REPAIRED IAW EO B757-5310-38197-A.SDR IPXA0560627Skin · dentedINSPECTION TYPE:C3, FOUND DENT ON EXTERIOR SKIN AT BS 247, S26R INSTALLED REPAIR DOUBLER IAW SRM53-00-01-2R.SDR IPXA10560570Hinge · elongatedINSPECTION TYPE:SP, WHILE WORKING CUSTOMER ID 874010, FOUND MAIN CARGO DOOR FWD HINGE (DOOR SIDE), TO HAVE AN ELONGATED HOLE AT THE FWD LWR HOLE LOCATION. REPAIRED IAW ER NR 10-3018, DATED 16JUN2010.SDR IPXA10560739Skin · chafedINSPECTION TYPE:C3, SKIN CHAFED ABOVE RT HORIZ STAB, COMMON TO STAB SEAL FROM BS 1829 TO 1872. REPAIRED IAW ATS ER10-3044.SDR IPXA10560738Skin · chafedINSPECTION TYPE:C3, SKIN CHAFED BELOW LT HORIZ STAB, COMMON TO STAB SEAL FROM BS 1798 TO 1870. REPAIRED IAW ATS ER10-3050.SDR IPXA10560737Skin · chafedINSPECTION TYPE:C3, SKIN CHAFED BELOW RT HORIZ STAB, COMMON TO STAB SEAL FROM BS 1798 TO 1870. REPAIRED IAW ATS ER10-3044.SDR IPXA10560569Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE, HAS AN OUT OF ROUND HOLE LOCATED 1ST HOLE AFT UPPER ROW AT NR 1 FWD HINGE SEGMENT. ATS ER NR 10-3018, DATED 16JUN2010.SDR IPXA10560568Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE HAS AN OUT OF ROUND HOLE LOCATED AT NR 8 HOLE UPPER ROW UNDER NR 10 HINGE SEGMENT. REPAIRED IAW ER NR 10-3018, DATED 16JUN2010.SDR IPXA10560567Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE HAS AN OUT OF ROUND HOLE LOCATED NR 9 HOLE UPPER ROW UNDER NR10 HINGE. REPAIRED IAW ER NR 10-3018, DATED 06-16-10.SDR IPXA10560566Hinge · corrodedINSP TYPE:SP MAIN CARGO DOOR NR 7 HINGE SEGMENT LOWER HINGE ON DOOR SIDE 2ND HOLE ON TOP IS CORRODED. REPAIRED IAW ER NR 10-3018 DATED 16-JUN-2010.SDR IPXA10560311Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS 480 TO BS 560, BL 0 TO RBL 25. FLOOR PANEL WAS REPALCED IAW EO B757-5320-9692-G.SDR IPXA10560291Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS 720 TO BS 820, BL 0 TO RBL 25. PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR IPXA10560290Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS480 TO BS560, BL0 TO RBL25. FLOOR PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR IPXA0560633Skin · dentedINSPECTION TYPE:C3, WHILE WORKING CUSTOMER CARD NR 864594, STR REPAIR, CAUSED DENT IN SKIN AT BS 1682, STR 15R. REPAIRED SKIN IAW ER NR10-3026.SDR IPXA10560565Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE, HAS AN OUT OF ROUND HOLE WITH FALSE POSITIVE INDICATION, LOCATED 3RD HOLE AFT UPPER ROLL AT NR 1 FWD HINGE SEGMENT. REPAIRED IAW ER 10-3018, DATED 16JUN2010.SDR IPXA10560386Shear Web · corrodedINSP TYPE:C1, FOR RCO TRACKING PURPOSES THERE IS CORROSION ON THE MAIN CARGO BAY UPPER SURFACE BS 1717, LBL 8, WL 208. SHEAR WEB WAS REPAIRED IAW ATS ER NR 10-2837.SDR IPXA10560345Floor Panel · damagedINSPECTION TYPE:C4, DUE TO FLOORBEAM SPLICE, FLOOR PANEL ATTACHING HOLES WILL FALL OUT IN RADIUS, FLOOR PANEL REQUIRES REPALCEMENT, FROM BS 1055-1100 LBL 25-45. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560344Floor Panel · damagedINSPECTION TYPE:C4, DUE TO FLOORBEAM SPLICE, FLOOR PANEL ATTACHING HOLES WILL FALL OUT IN RADIUS, FLOOR PANEL REQUIRES REPLACEMENT, FROM BS 1100-1200 LBL 25-45. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560356Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON LONGIDUDINAL FLOOR BEAM AT LBL 25 BS 1040-1080. R & R BEAM IAW SRM 51-40-02.SDR IPXA10560211Bulb · burned outCOCKPIT EMERGENCY EXIT LIGHT / SIGN ABOVE CREW ENTRY DOOR HAS BULBS BURNED OUT. RELAMPED. COCKPIT EMERGENCY EXIT LIGHT BULBS IAW MM 33-51-01-2. OPS CHECK GOOD.SDR IPXA10560700Frame · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FRAME INNER FLANGE HAS SCREW START AT BS 1580, STR 14L. REPAIRED IAW ATS ER NR 10-2996.SDR IPXA10560388Attach Fitting · brokenINSPECTION TYPE:C2, WHILE REMOVING THE 9-G BARRIER CTR SECTION, FOUND CLIP BROKEN AT BS 335, STR 1 CL. R & R CLIP IAW SRM 51-40-02-0G.SDR IPXA0560632Stringer · crackedINSPECTION TYPE:C3 CRACKED UPPER WEB OF STRINGER 15R AT BS 1681. REPAIRED STRINGER IAW ER NR 10-3026.SDR IPXA10560549Tension Tie · mismanufacturedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 1-2 LT. REPAIR IAW ATS ER NR 10-2902.SDR IPXA10560548Tension Tie · damagedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 1-2 RT. REPAIR IAW ATS ER 10-2902.SDR IPXA10560547Tension Tie · damagedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 2-3 LT. REPAIR IAW ATS ER NR 10-2902.SDR IPXA0560651Floor Support · corrodedINSPECTION TYPE:C2, MAIN CARGO STA 340 TO STA 418 LBL 24.75 TO LBL 45.5 SHEAR WEB IS CORRODED NUMEROUS PLACES. REPLACED CORRODED SHEAR WEB IAW SRM 53-00-51-1A SRM 53-00-51-1A.SDR IPXA10560455Tension Tie · misinstalledINSPECTION TYPE:C2 9-G BULKHEAD CTR SECTION TENSION STRAP UPPER ATTACHMENT HOLES ARE DOUBLE DRILLED BETWEEN STRINGER 2L AND 3L. REPAIR IAW ER10-2901.SDR IPXA10560454Tension Tie · misinstalledINSPECTION TYPE:C2, 9-G BULKHEAD CTR SECTION TENSION STRAP UPPER ATTACHMENT HOLES ARE DOUBLE DRILLED BETWEEN STRINGER 1 AND 2L. REPAIR IAW ER10-2901.SDR IPXA10560453Tension Tie · mismanufacturedINSPECTION TYPE:C2, 9-G BULKHEAD CTR SECTION TENSION STRAP UPPER ATTACHMENT HOLES ARE DOUBLE DRILLED BETWEEN STRINGER 1 AND 2R. REPAIR IAW ER NR 10-2901.SDR IPXA10560288Support · damagedINSPECTION TYPE:C4, AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CLIP DAMAGED AT BS 1480, LBL 20, WL 155. FLOOR TO SIDEWALL SUPPORT WAS REPLACED IAW SRM 51-40-02-0G.SDR IPXA10560155Support · damagedINSPECTION TYPE:C4, AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CLIP DAMAGED AT BS 1500 LBL 16.5 WL 155. REMOVED CLIP, REMOVED DAMAGE & FOUND TO BE WITHIN REPAIRABLE LIMITS, HFEC NO CRACKS FOUND, ALODINED PRIMED & REINSTALLED IAW SRM 51-20-01-0G, SRM 53-00-53-1A.SDR IPXA10560733Frame · gougedINSPECTION TYPE:C3, GOUGE IN FRAME AT BS 1620 AT STR 13-14 LT IS IN THE RADIUS AND CAN NOT BE CLEANED UP IAW THE SRM. REPAIRED IAW ATS ER 10-2946.SDR IPXA10560306Skin · damagedINSPECTION TYPE:C2, FOUND DRILL START IN SKIN AT STR 11, LT BS 1210. DRILLED OUT DAMAGE AT INSTALLED RIVET IN SKIN AT STR 11, LT BS 1210 IAW ER 10-2965.SDR IPXA10560117Splice · corrodedINSPECTION TYPE:C4, FLOOR PANEL SPLICE IS CORRODED IN AFT CARGO BAY BS 1510 REPLACED SPLICE STRAP IAW SRM 51-40-05, SRM 51-40-08-0G, SRM 51-40-02, SRM 53-00-53-1A, AMM 51-21-04-7, AMM 51-21-10-7, SRM 53-60-53-0I.SDR IPXA10560116Splice · corrodedINSPECTION TYPE:C4, FLOOR PANEL SPLICE IS CORRODED IN AFT CARGO BAY BS 1330. REPLACED SPLICE STRAP IAW SRM 53-00-53-1A, SRM 51-40-05-0G, SRM 51-40-08-0G, AMM 51-21-04-7, AMM 51-21-10-7, SRM 51-40-02-0G, SRM 53-60-53-01.SDR IPXA10560110Floor Panel · damagedMCD POSITION 1 RT INBD FLOORBOARD PANEL DAMAGED (PNL MARKED 4F) REMOVED FOR REPAIR PANEL PN 141N5410-6. IDENTIFIED AS A MAJOR REPAIR TRANSFERRED TO N/R 415800 REPLACEMENT PANEL FABRICATED IAW EO B7575320-9692-G, 0559106 5/23/10 OK TO INSTALL PANEL 0559189 5/2SDR IPXA10560109Floor Panel · damagedMCD POSITION 1, LT INBD FLOORBOARD DAMAGED (PNL MARKED 3F) REMOVED FOR REPAIR PANEL PN 141N5410-5. IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO N/R 415796, 0559106 5/23/10 F, FABRICATED NEW PANEL IAW EO B757-5320-9692, G 0559106 5/23/10. OK TO INSTALL PANEL. RSSDR IPXA10560106Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL DAMAGED PANEL MARKED 2F REMOVED FOR REPAIR PANEL PN 141N5410-4. IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO N/R 415795 FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692G 0559106 5-23-10 OK TO INSTALL PANEL 0559189 5/23/10 PANEL 2F SDR IPXA10560105Floor Panel · damagedMCD POSITION NR 1 LT OTBD FLOOR PANEL DAMAGED (PANEL MARKED 1F) REMOVED F/O FOR REPAIR PANEL PN 141N5410-3 IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO NR 415794 FABRICATED PANEL IAW EO B757-5320-9692-G, OK TO INSTALL PANEL RSC 0559189 5/23/10, PANEL 1F INSTALLEDSDR IPXA10560848Former · damagedINSPECTION TYPE:C4, WHILE CLOSING WING TO BODY FAIRING FOUND FAIRING FORMER TO BE DAMAGED AT 3 EA NUTPLATE ATTACH POINTS BS860, RBL44, 47 AND66 REPAIRED IAW SRM 51-70-12-0G.SDR IPXA10560140Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO BAY NR 3 FLOOR PANEL IS CORRODED ON THE UPPER SURFACE. REMOVED, FABRICATED, AND INSTALLED NR FLOOR PANEL IAW SRM 51-10-07-0G, SRM 53-00-53-1A, SRM 51-40-02-0G.SDR IPXA10560115Splice · corrodedINSPECTION TYPE:C4, AFT CARGO COMPARTMENT, NR 3 FLOOR PANEL SPLICE IS CORRODED. REPLACED SPLICE STRAP IAW SRM 53-00-53-1A, SRM 51-40-05-0G, SRM 51-40-08-0G, AMM 51-21-04-7, AMM 51-21-10-7, SRM 51-40-02-0G, SRM 53-60-53-0I.SDR IPXA10560550Tension Tie · damagedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 2-3 RT. REPAIR IAW ATS ER 10-2902.SDR IPXA10560456Rib · corrodedINSPECTION TYPE:C3, T/E RIB AT LT WS 817.27 CORRODED AROUND AILERON BONDING STRAP ATTACH POINT. REPAIRED IAW ATS ER NR 10-2957.SDR IPXA10560452Tension Tie · mismanufacturedINSPECTION TYPE:C2, 9G BULKHEAD CTR SECTION FOUND TO HAVE 4EA TENSION STRAPS DOUBLE DRILLED, STR 3L-3R. REPAIR IAW ER 10-2901.SDR IPXA10560262Skin · debondedINSPECTION TYPE:C4 RT WING OTBD AFT FLAP LWR SURFACE 26" FROM OTBB END 3" UP FROM L/E AREA OF POSSIBLE DISBOND NOTED. REPAIRED IAW SRM 51-70-04.SDR IPXA10560142Floorboard · damagedINSPECTION TYPE:C2, FLOORBOARD DAMAGED STA 1100 - 1200, RBL 45 - 60 FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10560138Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO FLOOR PANEL CORRODED BS 505 TO 545. FABRICATED NEW PANEL IAW SRM 53-00-53-1A.
Back to Boeing 757-24APF