Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2018042628989Floor Panel · delaminatedINSPECTION TYPE: SEG 3, FLOOR PANEL 231XGF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018042708988Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 222XAF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018042708987Bulb · inoperativeEMERGENCY LIGHT HAS TWO INOPERATIVE BULBS. R & R THE BULBS IAW AMM 33-51-01.SDR IPXA201804278927Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN CARGO DECK FLOOR PANEL 241XKF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018042528929Floorboard · damagedINSPECTION TYPE: SEG3, MAIN DECK FLOORBOARD 232HF FOUND DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-K.SDR IPXA201804278928Floorboard · damagedINSPECTION TYPE: SEG3, MAIN DECK FLOORBOARD 231XHF FOUND DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-K.SDR IPXA2018042428900Hydraulic System · failedCREW EXPERIENCED A LEFT HYD FAILURE. SERVICED THE LEFT MAIN HYD RESERVOIR IAW MM 29-00-00.SDR IPXA2018042088736Bulb · inoperativeEMERGENCY LIGHT HAS THREE INOPERATIVE BULBS. REPLACED THE BULBS IAW AMM 33-51-01-962.SDR IPXA2018042028758Door · missingNR 1 ENGINE IDG SERVICING DOOR MISSING FROM LEFT SIDE OF THE NACELLE, NO FURTHER DAMAGE NOTED. TEMP REPAIR COMPLETEDSDR IPXA2018051829753Radar · malfunctionedAIR TURNBACK DUE TO THE WEATHER RADAR SYSTEM FAIL DISPLAYED ON EHSI. WEATHER RADAR TEST DISPLAY. REPLACED THE RT WEATHER RADAR UNIT IAW MM 34-43-01, OPS CHECKED NORMAL.SDR IPXA2018042528931Floorboard · damagedINSPECTION TYPE: SEG3, MAIN DECK FLOORBOARD 231XCF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-KSDR IPXA2018041828709Panel · missingNR 2 ENGINE INBOARD PYLON MISSING PANEL 443HL. INSTALLED A NEW PANEL IAW MM 54-53-01. OK FOR SERVICE.SDR IPXA2018041228508Bulb · inoperativeEMERGENCY LIGHT HAS FOUR BULBS INOPERATIVE. REPLACED THE BULBS IAW 33-51-01-2.SDR IPXA2018042088711Floor Panel · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018042088717Floor Panel · delaminatedINSPECTION TYPE: SEG2, MCD FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018041028439Valve · malfunctionedAPU FAILED IN FLIGHT, THE APU FAULT LIGHT AND EICAS ILLUMINATED. PERFORMED AN APU BITE TEST IAW MM 49-61-05-742-049. REVERSE FLOW PRESENT ON BITE. IAW FIM 49-11-00-815-880-002-2. REMOVED AND REPLACED THE APU SURGE VALVE IAW MM 49-53-01. OPS CHECKED GOODSDR IPXA2018041528579Floor Panel · damagedINSPECTION TYPE: SEG2, MAIN CARGO DECK FLOOR PANEL 242XCF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018040928372Bracket · bentDURING DESCENT THRU 7000 FT, A PAX DOOR MESSAGE ILLUMINATED. CAUTION WENT OUT ON ITS OWN THROUGH 2000 FT. THE PAX DOOR PROXIMITY SWITCH BRACKET APPEARED TO BE BENT. INSTALLED A SERVICEABLE BRACKET IAW MM 52-71-00.SDR IPXA2018041028440Beam · gougedINSPECTION TYPE: SEG4, THE RT MLG DOOR SUPPORT BEAM WAS FOUND GOUGED. REPAIRED THE BEAM IAW EA757-3212-27-A2295.SDR IPXA2018040528232Unknown · odorSTRONG DIRTY SOCK ODOR FROM RIGHT PACK, OPERATED THE RIGHT PACK FOR 30 MINUTES IAW MM 21-00-00-862-001. COULD NOT DUPLICATE THE ODOR. OKAY TO CONTINUE FLIGHT.SDR IPXA2018040528220Oil System · overservicedFAINT OIL BURNING OR PNUMATIC BURNING ODOR EMERGED ENROUTE, CONDITION BECAME WORSE DURING DESCENT. NO SMOKE PRESENT IN COCKPIT. PERFORMED AIR CONDITIONING CONTAMINATION TASK SUGGEST ODOR POS ORIGINATING FROM OVER FILLED ENGINE OIL SYSTEM 23QTS IAW FIM 21-00SDR IPXA2018040528219Altimeter · intermittentFIRST OFFICER`S ALTIMETER SHOWED INTERMITTANT FLAG ENROUTE. R & R THE FIRST OFFICER'S ALTIMETER IAW AMM 34-13-01. OPS CHECKED GOOD.SDR IPXA2018040328153Wire · detachedEMERGENCY LIGHT GUARDED SWITCH WIRE SEPARATED. INSTALLED THE WIRE. CHECKED GOOD.SDR IPXA2018040328112Transmitter · false activationDURING FLIGHT, SHUTDOWN THE LT ENGINE, VIBRATION READS 5.0, ENGINE INDICATIONS NORMAL. VIBRATION REMAINED ABOVE 2.5 WITH THRUST LEVEL RETARDED TO IDLE. THE ENGINE WAS SHUT DOWN . NO VIBRATION WAS FELT. CHECKED CHIP DETECTORS. IAW MM 78-00-00/601. R & SDR IPXA2018032927953Bulb · inoperativeEMERGENCY LIGHT HAS THREE BULBS INOPERATIVE. REPLACED THE BULBS IAW AMM 33-51-01-2.SDR IPXA2018032827932Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 251XMF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032427777Lamp · inoperativeEMERGENCY LIGHT BELOW & AFT OF THE L1 DOOR WAS INOPERATIVE DURING A CHECK. R & R THE LAMP IAW AMM 33-51-06-962-001-003. OPS CHECKED GOOD. OK FOR SERVICE.SDR IPXA2018032327754Floorbeam · corrodedINSPECTION TYPE: SEG3, BS 620, RBL 50, FLOORBEAM CORRODED. ACCOMPLISHED A REPAIR IAW B757-5310-67861-A.SDR IPXA2018032327734Bulb · inoperativeEMERGENCY LIGHT HAS SIX INOPERATIVE BULBS. R & R THE LAMPS IAW AMM 33-51-01-02.SDR IPXA2018032227725Evas Unit · inoperativeCAPTAIN`S EVAS INOPERATIVE. INSTALLED A NEW EVAS UNIT IAW AMM 25-69-00, OPS CHECKED GOOD.SDR IPXA2018032127682Sensor · inoperativeACFT PRESSURIZED SLOWLY, FAILED TO MAINTAIN CABIN ALTITUDE. R & R THE RT PACK COMPRESSOR OUTLET SENSOR NR 1 IAW AMM 21-51-06-401. PERFORMED PRESSURE LEAKAGE RATE CHECK IAW AMM 05-51-24-702-001, TESTED OK, LEAK CHECKED RT & LT PACKS FOR LEAKS. NO LEAKS NSDR IPXA2018031927621Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN CARGO DECK FLOOR PANEL 251XMF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018040328140Panel · delaminatedINSPECTION TYPE: SEG3, WHILE PERFORMING TAP TEST IAW S55-610-100-2, FOUND THREE AREAS OF DELAMINATION ON THE RT VERTICAL STAB LOWER FWD TORQUE BOX PANEL. REMOVED AND REPLACED THE PANEL IAW SRM 51-40-02-OG, AND AMM 51-21-10.SDR IPXA2018032527805Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018040628278Panel · delaminatedINSPECTION TYPE: SEG4, VERTICAL STAB RT SIDE LOWER FORWARD TORQUE BOX PANEL DELAMINATED. REPLACED THE PANEL IAW SRM 51-40-02-0G.SDR IPXA2018031627527Floor Support · corrodedINSPECTION TYPE: SEG3, LT REAR MCD FLOOR SUPPORT HAS CORROSION BS 1680 LBL 24.75. REPAIRED IAW SRM 53-60-51-2R-8SDR IPXA2018031627524Evas Unit · inoperativeCAPTAIN'S EVAS BLOWER INOPERATIVE IAW TC 25-069-00. REPLACED THE CAPTAIN'S EVAS IAW AMM 25-64-00.SDR IPXA2018031727533Bulb · inoperativeEMERGENCY LIGHT BULBS INOPERATIVE REPLACED THE BULBS AMM 33-51-01-2.SDR IPXA2018032727899Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XFF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032727896Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XJF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032727895Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XJF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032827929Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 252XTF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032627831Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 241XMF HAS BROKEN INSERT HOLES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527809Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527808Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527807Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XHF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527806Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527804Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XDF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527803Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XDF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527802Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 252XRF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.
Back to Boeing 757-24APF