Boeing 757-2B7
Service difficulty reports · 3,730
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAABB03102Light · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 6 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03104Battery · inoperativeFOUND R3 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03098Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 6, 9, 13, 18, 26 AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03097Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 18 AND 23 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03100Module · weakFOUND THE FORWARD EMERGENCY AISLE LIGHT MODULE BATTERY WEAK. MAINTENANCE REPLACED THE MODULE. (M)SDR USAABB03099Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 4, 9, 18, 23, 29 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03096Battery Pack · inoperativeALL FLOOR LEVEL EMERGENCY LIGHTS FAILED TO TEST. MAINTENANCE REPLACED ALL THE BATTERY PACKS. (M)SDR USAABB03090Battery · inoperativeFOUND L2 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03089Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK. (M)SDR USAABB03088Battery · inoperativeLAX - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1, 4, 6, 13, 18 AND 26 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03086Light · inoperativeFOUND L3 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03085Battery · inoperativeFOUND EXIT IDENTIFIER AT L2 DOOR INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03084Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LGIHT AT ROW 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03080Battery · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 23 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03079Light · missingPIT - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 1 MISSING. MAINTENANCE HAD PREVIOUSLY REPLACED THE SEAT ROW AND NOT INSTALLED THE LIGHT. LIGHT WAS INSTALLED. (M)SDR USAA030078Frame · corrodedCLT - FOUND 2 INCHES OF CORROSION, STATION 1400 BETWEEN S28L-S27L ON OUTER FRAME. REMOVED CORROSION AND INSTALLED REPAIR FASTENERS PER EA 87238. (M)SDR USAABB03076Battery · dischargedCLT - EXIT IDENTIFIER AT DOOR R3 FLASHING. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03077Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03075Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 23 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03074Battery · failedTHE FLOOR LEVEL EMERGENCY LIGHT AT ROW 29 FAILED. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03073Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 4 AND 26 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03072Lanyard · frayedFOUND FRAYED LANYARD ON R1 DOOR SLIDE. MAINTENANCE FOUND THAT THE COVER ATTACH LANYARD WAS FRAYED. THE SLIDE WAS REPLACED. (M)SDR USAABB03067Battery · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHTS WEAK AT ROWS 4, 13, 29 AND 33. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03062Light · inoperativeFOUND AISLE EMERGENCY LIGHT ASSEMBLY AT SEAT ROW 18DEF INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. OPERATIONAL CHECK GOOD. (M)SDR USAABB03061Light · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03060Light · inoperativeBWI - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA030039Frame · crackedCLT - FOUND FRAME CRACKED 2 INCHES, LEFT PACK BAY, FRAME AT BS 900 LBL 0. INSTALLED FABRICATED REPAIR SPLICE DOUBLER PER EA 87134. (M)SDR USAABB03059Light · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA030038Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .5 INCH BY .75 INCH, STATION 1640 LBL 40, RBL 30 UPPER SURFACE. FULL REPLACEMENT OF UPPER STRUCTURE, ADDED WEIGHT OF REPAIR 4.3 LBS PER TR 53-15-01. (M)SDR USAABB03055Windshield · smokeDEN - FLT 607 - APPROXIMATELY FORTY MILES EAST OF DENVER, SMOKE BEGAN TO POUR FROM THE AREA OF THE CAPTAIN'S GLARESHIELD. CREW DONNED SMOKE GOGGLES AND OXYGEN MASKS. FLIGHT DIVERTED TO DENVER AND LANDED WITHOUT FURTHER INCIDENT. S/D - MAINTENANCE FOUND THE SDR USAABB03053Light · inoperativeLAX - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03057Packing · leakingEN ROUTE PHL-PHX, WITH THE LFT GENERATOR ON MEL AND APU OPERATING, THE CREW NOTED A DECREASE IN THE APU OIL FROM 'FULL' TO .'50' TO 'REFILL'. SHORTLY THEREAFTER THE APU PERFORMED AN AUTO SHUTDOWN. FLIGHT DIVERTED TO DEN AND LANDED WITHOUT FURTHER INCIDENT. SDR USAABB03052Battery · inoperativeBOS - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1, 4, 6 AND 9 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03049Light · inoperativeCLT - FOUND EMERGENCY LIGHT AT ROW 4 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03050Bearing Seal · leakingDEN - FLT 167 - EN ROUTE PHL-PHX, WITH THE LT GENERATOR ON MEL AND APU OPERATING, THE CREW NOTED A DECREASE IN THE PAU OIL FROM FULL TO REFILL. SHORTLY THEREAFTER THE APU PERFORMED AN AUTO SHUTDOWN. FLIGHT DIVERTED TO DEN AND LANDED WITHOUT FURTHER INCIDENT.SDR USAABB03048Odor · detectedCLT - FLT 1160 - CREW REPORTED STRONG ELECTRICAL ODOR AND SMOKE WHEN RADAR IN USE. MAINTENANCE COULD NOT DUPLICATE THE PROBLEM. THE RADAR TRANSCEIVER WAS REPLACED AS A PRECAUTION. (M)SDR USAABB03047Light · inoperativeBDL - FOUND R1 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03046Battery · inoperativeBOS - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03045Battery · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHTS ARE ROWS 1, 4, 6, 26 AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03044Battery · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1, 6, 9, 18 23 AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03051Battery · inoperativePHL - FOUND EXIT IDENTIFIERS AT L1 AND R4 DOORS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB03043Battery · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 9 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03042Bulb · burned outPIT - FLT 391 - ON APPROACH, CREW DID NOT RECEIVE A GREEN SAFE INDICATION ON THE RIGHT MAIN LANDING GEAR. NO OTHER ABNORMAL INDICATIONS WERE PRESENT. CREW PERFORMED A GO-AROUND. TOWER CONFIRMED ALL GEAR WERE DOWN. FLIGHT LANDED WITHOUT FURTHR INCIDENT. MASDR USAABB03041Light · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 9 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03038Battery · inoperativeBDL - FOUND R2 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03039Battery · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 23 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB03040Light · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03036Light · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB03034Battery · dischargedFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS, 1,4, 6 AND 9, INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES.SDR USAABB03033Light · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 1, INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY.
Back to Boeing 757-2B7