SDR DALA2021022401075Support Frame · damagedDURING INITIAL INSPECTION MAINTENANCE FOUND TOOL MARKS ON SUPPORT FRAME STA 740 BTW S- 22R AND S-25R AT FWD CARGO COMPARTMENT. SUPPORT FRAME REPAIRED PER SRM. (LP 1738177)SDR DALA2021022401074Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS UPPER AND LOWER SURFACE BTW STA 1460 TO STA 1480 AND RBL 2.90, 7.55, 10.45, 16.10 AND LBL 2.90, 7.55, 10.45, 16.10 AFT CARGO COMPARTMENT. REPAIRED PER SRM. (LP 1737801)SDR DALA2021030101121Skin · dentedDURING DECAL INSPECTION MAINTENANCE FOUND DENT OUT OF LIMITS BTW STA 590-620 AT FWD CARGO DOOR IN REF LOG 3525323. REPAIRED PER SRM 52-30-01. (LP 1736433)SDR DALA2021022201017Brace · corrodedWHILE PERFORMING LT ENGINE DRAG FITTINGS CLAMP-UP & DIAGONAL BRACE INSPECTIONS MAINTENANCE FOUND LTS UPPER SKIN & DRAG FITTINGS CORROSION AND TOOLING DAMAGE AT HOLE 2. REPAIRED PER ERA 590151-14. (LP 1736509)SDR DALA2024072907591Skin · unknownSHIP 5813 ERA 590190-14 ISSUED FOR REPAIR TO FUSELAGE SKIN AT STATIONS 154 0-1560, BETWEEN STRINGERS 27R TO 29R. CORRECTIVE ACTION: REF ERA 590190-14. (1736037)SDR DALA2021030101120Skin · dentedDURING DECAL INSPECTION MAINTENANCE FOUND CGO DR;FWD;S/N325; DENT OUT OF LIMITS BTW STA 590-620 AT FWD CARGO DOOR IN REF LOG 3525323 AND REPAIRED PER SRM 52-30-01. (LP 1736232)SDR DALA2021022201016Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGERS UPPER AND LOWER SURFACE BTW STA 1320 TO STA 1340 FLOOR STRINGERS RBL 2.90, 7.55, 10.45, 16.10 AND LBL 2.90, 7.55, 10.45 AFT CARGO COMPARTMENT AND REPAIRED PER SRM. (LP 1735964)SDR DALA2021122808098None · noneSHIP 5813 REPAIR TO LH WING UPPER SKIN COMMON TO DRAG FITTING ATTACHMENT REQUIRES SUPPLEMENTAL INSPECTIONS PER ERA 590151-14AD. CORRECTIVE ACTION: REF ERA 590151-14AD. (1734413)SDR DALA2021022201010Drag Fitting · corrodedDURING RT ENGINE DRAG FITTINGS CLAMP-UP & DIAGONAL BRACE INSPECTIONS MAINTENANCE FOUND CORROSION, BURRS, A CRACK AND OUT-OF-SIZE CONDITION WERE FOUND AFFECTING HOLES 1-4, 6-10, 13, 15, 16 & 18, COMMON TO RT WING UPPER SKIN AND FWD DRAG FITTINGS AT OUTER WING RSDR DALA2021022201006Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON STRINGERS LBL 2.90, LBL 7.55, LBL 16.10 AND RBL 2.90, RBL 7.55, RBL 10.45 BTW STA 740 TO 760 OF FWD CARGO COMPARTMENT. STRINGERS REPAIRED PER SRM.SDR DALA2021022201005Intercostal · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON INTERCOSTAL BTW STA 1600 TO STA 1620 AND S-29L TO S-30 AT AFT CARGO COMPARTMENT. REPLACED INTERCOSTAL PER SRM.SDR DALA2021021800950Strap · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON STRAP AT CARGO COMPARTMENT FLOOR PANEL.. FLOOR PANEL REPLACED. (LP 1733231)SDR DALA2021021800948Frame · damagedDURING INSPECTION MAINTENANCE FOUND ELONGATE HOLES ON FRAME STA 1300 BTW S-30/ S -29L AT AFT CARGO COMPARTMENT. REPAIRED PER ERA 590086-14. (LP 1732424)SDR DALA2021030101123Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR BEAM STA 377 BTW LBL 10 TO LBL 24 AND LBL 51 TO LBL 54 AT PAX CABIN FLOOR STRUCTURE. REPAIRED PER ERA 481634-14. (LP 1732084)SDR DALA2021021800947Angle · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON ANGLE BTW STA 1500 AND S-29L TO S-30 AT AFT CARGO COMPARTMENT AND REPLACED.SDR DALA2021021800946Angle · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON ANGLE BTW STA 1500 TO STA 1510 AND S-29L TO S-30 AT AFT CARGO COMPARTMENT AND REPLACED.SDR DALA2021021800949Ground Wire · unsecureSHIP 5811 EMERGENCY LIGHTS ARE ROW 33-40 ARE INOPERATIVE. MAINTENANCE FOUND GROUND WIRE WITH POOR CONNECTION AND SECURED GROUND WIRE. SYSTEM OPERATION IS NORMAL. (LP 6292596)SDR DALA2021021600851Support Fitting · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FITTING SUPPORT STA. 1400 IN DOOR CUT OUT LOWER AREA AT AFT CARGO COMPARTMENT. FITTING SUPPORT WAS REPLACED. (LP 1730438)SDR DALA2021021600850Intercostal · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON INTERCOSTAL BTW STA 1420 TO STA 1440 AND S-28R TO S-29R AFT CARGO COMPARTMENT. REPLACED PER SRM. (LP 1729929)SDR DALA2021021600847Intercostal · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON INTERCOSTAL BTW STA 1500 TO STA 1520 AND S-29L TO S-30 AT AFT CARGO COMPARTMENT. INTERCOSTAL REPLACED PER SRM. (LP 1729701)SDR DALA2021021600846Angle · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON ANGEL 146N5454-3 AND REPLACED. (LP 1729424)SDR DALA2021021600844Frame · crackedDURING INITIAL INSPECTION MAINTENANCE FOUND CARCK ON FRAM STA 760LH BTW S-8L AND S-9L AT PASSENGER CABIN. REPAIRED PER SRM 53-00-07. (LP 1729307)SDR DALA2021021600843Intercostal · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVE 2 ON INTERCOSTAL BTW STA 1400/1420 AND STR 30/29RH AT AFT CARGO COMPARTMENT. INTERCOSTAL REPLACED PER SRM. (LP 1728779)SDR DALA2021021600841Intercostal · corrodedDURING INSPECTION MAITNENANCE FOUND CORROSION LEVEL 2 ON INTERCOSTAL BTW STA 1420/1440 STR 29/28 RH AT AFT CARGO COMPARTMENT. INTERCOSTAL REPAIRED PER SRM 51-70-11. (LP 1728144)SDR DALA2021021600840Deck Plate · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON DECK PLATE STA 1680 BTW LBL 0 TO LBL 21.5 PAX CABIN FLOOR STRUCTURE. FLOOR REPAIRD PER SRM. (LP 1728023)SDR DALA2021021100798Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR SUPPORT STA 1661-1681 LBL 55 AT PAXCABIN FLOOR STRUCTURE . FLOOR SUPPORT REPLACED. (LP 1727722)SDR DALA2021021100797Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR BEAM AT STA 1640 BTW RBL 51 TO RBL 60. FLOOR BEAM REPAIRED PER SRM. (LP 1727639)SDR DALA2021021100796Frame Angle · corrodedDURING INSPECTION MAINTENANCE FOUND HIDDEN CORROSION: CORRSION ON FRAME CLIP STA 1560 BTW S-28R TO 29-R AT AFT CARGO COMPARTMENT. REPLACED FRAM CLIP. (LP 1727318)SDR DALA2021021100795Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS ON STA.640-660 AND LBL 16.10 IS 0.071". STRINGER REPAIRED PER SRM. (LP 1727189)SDR DALA2021021100799Cover · missingSHIP 5803 CENTER ISLE EMERGENCY EXIT SIGN ADJACENT TO L3 DOOR FOUND MISSING. CORRECTIVE ACTION: REPLACED EXIT COVER. SYSTEM OPERATION IS NORMAL. (LP7661609)SDR DALA2021021000769Battery Pack · inoperativeEMERGENCY AISLE LIGHT ARE INOPERATIVE AT ROWS 33-40. MAINTENANCE REPLACED THE BATTERY PACKS. SYSTEM OPERATION IS NORMAL.(LP 6292575)SDR DALA2021021000768Floor Support · corrodedMAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGERS BTW STA 780+140 TO STA 780+160 AND LBL 10.45 AND RBL 2.90, 7.55 AT FWD CARGO COMPARTMENT BILGE AREA. REPAIRED PER SRM. (LP 1726779)SDR DALA2021021000767Strap · crackedDURING INSPECTION MAINTENANCE FOUND CRACK STABILIZATION STRAP IN STA 580 AND BTW LBL 15-30 OF FORWARD CARGO COMPARTMENT. REPAIRED PER SRM. (LP 1725993)SDR DALA2021020800716Intercostal · corrodedDURING INSPECITON MAINTENANCE FOUND CORROSION LEVEL 2 AND CRACK ON INTERCOSTAL BTW STA1300/1320 AND STR 30/29 LH AT AFT CARGO COMPARTMENT (CCT)SDR DALA2021020800712Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGER AT BTW STA 780+60-780+80 LBL 16.10 AND REPAIRED PER SRM. (LP 1724955)SDR DALA2021020800721Panel · corrodedDURING INSPECITON MAINTENANCE FOUND CORROSION LEVEL 2 ON SIDE PANEL LH UPPER AND LOWER SURFACE BTW STA 756 - 765. SIDE PANEL REPAIRED PER SRM. (LP 1723938)SDR DALA2021020800720Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION ON FLOOR STRINGER BTW STA 13201340 AND 2.90, 7.55, 10.45 LH ALSO 2.90, 7.55, 16.10 RH AT AFT CARGO COMPARTMENTSDR DALA2021020800711Floor Support · corrodedDURING INSPECTION MANTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS BTW STA 740 TO STA 760 AT LBL 2.90 AT FWD CARGO COMP. BILGE AREA. REPAIRED PER SRM. (LP 1724540)SDR DALA2021020800709Light · inoperativeSEAT MOUNT EMERGENCY LIGHTS AT ROW 41 INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL. (LP 5031093)SDR DALA2021020800708Power Supply · inoperativeCEILING EMERGENCY LIGHTS AT ROW 29 ARE INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY. SYSTEM OPERATION IS NORMAL. (LP 5031092)SDR DALA2021020800707Charger · inoperativeLOWER OVERWING EMERGENCY LIGHTS AT RIGHT AFT INOPERATIVE. MAINTENANCE REPLACED BATTERY CHARGER M11384 SYSTEM OPERATION IS NORMAL (LP 5031091)SDR DALA2021020800706Strap · crackedDURING INITIAL INSPECTION MAINTENANCE FOUND CRACK STABILIZATION STRAP AT STA 345 LBL 45 AT PASSENGER COMPARTMENT. STRAP REPAIRED PER SRM. (LP 1723733)SDR DALA2021020800705Strap · crackedDURING INITIAL INSPECTION MAINTENANCE FOUND CRACK ON STABILIZATION STRAP AT STA 1620 AND LBL 50 APRRX AT PASSENGER CABIN. STRAP REPAIRED PER SRM. (LP 1723727)SDR DALA2021020800704Strap · crackedDURINNG INSPECTION MAINTENANCE FOUND CRACK ON STABILIZER STRAP STA 1620 AND 45 LBL AT AFT CARGO COMPARTMENT. STRAP REPAIRED PER SRM. (LP 1723539)SDR DALA2021020500701Seal · leakingSHIP 5212 L2 DOOR SEAL MAKING LOUD NOISE, LOUDER PASSING 10,000 FEEL DID NOT GO AWAY AT ALTITUDE. MAINTENANCE FOUND SEAL OUT OF RETAINER. RE-INSTALLED SEAL. DOOR OPERATION IS GOOD. (LP 5031080)SDR DALA2021020300655Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS ON STA.620-640 AND LBL 2.90 AND RBL 7.55 IS 0.071. STRINGERS REPAIRED PER SRM (LP 1720498)SDR DALA2021020300653Skin · dentedDURING INSPECTION MAINTENANCE FOUND DENT ON OUTER FUSELAGE SKIN STA 1716 BTW S-15R TO S-16R.REPAIRED PER ERA 589758-14. (LP 1720335)SDR DALA2021013100570Stringer · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON STRINGER SPLICE BETWEEN STA 1615/1625 AND STR 30 AT AFT CARGO COMPARTMENT. STRINGER SPLICED REPLACED.SDR DALA2021012700499Connector · disconnectedEMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE FOUND CONNECTOR DISCONNECTED AND RE-CONNECTED. SYSTEM OPERATION IS NORMAL.SDR DALA2021012700498Plate · corrodedDURING INSPECTION MAINTENENACE FOUND LEVEL 2 CORROSION ON PLATE STA 1681 AND 0 BL AT PASSENGER CABIN FLOOR STRUCTURE AND REPLACED.
Back to Boeing 757-351