Boeing 757-351
Service difficulty reports · 3,199
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757351' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757351' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020102603468Floor Support · corrodedCORROSION LEVEL 2, DURING INITIAL INSPECTION: CORROSION ON INTERCOSTAL FLOOR SUPPORT FROM STA 1460-1480, S-28R AT AFT CARGO COMPARTMENT. FLOOR SUPPORT REPLACED.SDR DALA2020102603463Channel · corrodedCORROSION LEVEL: DURING INSPECTION CORROSION WAS FOUND ON INTERCOSTAL CHANNEL BETWEEN STA 365-395 LBL 60 AT PASSENGER COMPARTMENT. REPLACED PER SRM.SDR DALA2020102603471Light · unsecureEMERGENCY SEAT MOUNTED LIGHTING AT 27D IS INOPERATIVE. CORRECTIVE ACTION: SECURED EMERGENCY LIGHT. SYSTEM OPERATION IS NORMAL.SDR DALA2020102603462Lens · missingEMERGENCY LIGHT LENS ON OVERHEAD BIN BULLNOSE AT ROW 31DEF MISSING. CORRECTIVE ACTION: REPLACED MISSING LENS. SYSTEM OPERATION IS NORMAL.SDR DALA2020102303443Floorbeam · corrodedCORROSION LEVEL: 2 DURING INSPECTION FOUND CORROSION ON UPPER CHORD BEAM, STA 365.25 BETWEEN BL 0 TO RBL 2 AT FLOOR PASSENGER CABIN STRUCTURE. REPARIED PER ERA 588248-14.SDR DALA2020102303442Strap · crackedDURING INITIAL INSPECTION FOUND CRACKED STABILIZATION STRAP STA 1640 LBL=28 AT AFT CARGO COMPARTMENT. STABLIZER STRAP WAS REPAIRED, PER SRM 53-00-51.SDR DALA2020102303438Door Sill · corrodedDURING INSPECTION FOUND LEVEL 2 CORROSION ON LOWER SILL, OUTER CHORD, L-4 DOOR BETWEEN STA 1660-STA 1680 AT PASSENGER CABIN. CORRODED AREA REPLACED.SDR DALA2020102303437Strap · crackedDURING INSPECTION FOUND CRACK ON STABILIZATION STRAP BETWEEN STA 700 TO STA 720 RBL 45 AT PASSENGER CABIN FLOOR STRUCTURE. STRAP REPAIRED, PER SRM 53-00-51.SDR DALA2020101903398Skin · dentedDURING INSPECTION FOUND A DENT ON FUSELAGE SKIN AND INCOMING REPAIR AT STA 600-640 BETWEEN S-15LAND S-18L. REPAIRED PER ERA 525966-14.SDR DALA2020101603378Floor Panel · dentedDURING INSPECTION FOUND PUNCTURES AND DENTS ONFLOOR PANEL #220-2, 220-3, 220-7, 220-12 AT PAX CABIN. FLOOR PANELS 220-3, 220-7, 220-12 WERE REPAIRED PER SRM 53-00-50 AND FLOOR PANEL 220-2 WAS FABRICATED AND REPLACED.SDR DALA2020101603377Strap · crackedDURING INIITAL INSPECTION FOUND CRACK ON STABILIZER STRAP FROM STA 365/377 AND 45 LBL AT PASSENGER CABIN (W1). REPAIRED PER SRM.SDR DALA2020101603379Switch · inoperativeTHE AFT LIGHT EMERGENCY TEST SWITCH WAS DISCOVERED TO BE INOPERATIVE. THIS IS CONSIDERED TO BE A DEFECT IN THE EMERGENCY ESCAPE SYSTEM AND COULD HAVE AN ADVERSE EFFECT ON THE EVACUATION ROUTE. MAINTENANCE FOUND THE SWITCH CAUSING A FLICKERING OF THE LIGHTS ANDSDR DALA2020100603294Fault Light · false activationTHE CREW DECLARED AN EMERGENCY ON APPROACH INTO ATL FOR A "FLAP TRAILING EDGE ASSYM" MESSAGE. THE LANDING WAS UNEVENTFUL AND THE AIRCRAFT TAXIED TO THE GATE. CORRECTIVE ACTION: CREW REPORTED WHEN MOVING FLAP HANDLE, THE 25 DEGREE DETENT WAS OVERSHOT AND HANDSDR DALA2020100503268Chain · unserviceableDURING INSTALL OF SLIDE WAS FOUND A WRONG CONFIGURATION ON RELEASE STRAP LATCH CHAIN. CORRECTIVE ACTION: ESCAPE SLIDE COVER WAS REMOVED AND INSTALLED AND LINKS AND BOLTS WERE INSTALLED.SDR DALA2020100503267Pin · out of positionMTC REQUEST: OUT OF PLACE UPPER PIN ON RT WING SLIDE PACK. CORRECTIVE ACTION: REPLACED SLIDE PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2020100403263Frame · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION AT FRAME WEB STA 1440, BETWEEN S-28R & S-30. REPAIRED PER ER/A 588054-14.SDR DALA2020092803225Wire Harness · damagedDURING INSPECTION FOUND EMERGENCY LIGHTS AT 36 DEF ARE INOPERATIVE. CORRECTIVE ACTION: REPLACED SEAT HARNESS AT 36 DEF. SYSTEM OPERATION IS NORMAL.SDR DALA2020092603175Frame · corrodedCORROSION LEVEL 2, DURING INITIAL INSPECTION, CORROSION WAS FOUND ON FRAME BETWEEN STR 29 RT / 27RT STA Y=1560 AT AFT CARGO COMPARTMENT. THE FRAME WAS REPAIRED, PER ERA 587768-14AD.SDR DALA2020092503164Stringer · corrodedCORROSION LEVEL 2, DURING INITIAL INSPECTION FOUND CORROSION ON STRINGER 23 RT BETWEEN STA Y+1620 AND Y+1600 AT AFT CARGO COMPARTMENT. STRINGER REPAIRED, PER ERA 587782-14.SDR DALA2020092503163Frame · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION ON FRAME STA 1420 BETWEEN S-30 AND S-29R AFT CARGO COMPARTMENT. REPAIRED CORROSION, PER ERA 587774-14.SDR DALA2020092503162Floorbeam · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION OUT OF LIMITS ON FLOOR BEAM STA 1681 BETWEEN LBL 24 AND LBL 32 AT WET AREA NR 4. FLOOR BEAM REPAIRED, PER ERA 587886-14.SDR DALA2020092303151Spring · failedDURING L2 SLIDE INSTALLATION, AFT/FWD GIRT BAR LEAF SPRINGS DOES NOT RETAIN. CORRECTIVE ACTION: GIRT BAR REPLACED.SDR DALA2020092203149Stringer · corrodedCORROSION LEVEL 2: DURING INITIAL INSPECTION FOUND CORROSION ON STRINGER 29RH FROM STA 1540 TO 1560 AT AFT CARGO COMPARTMENT (C2). STRINGER REPAIRED, PER ERA 587847-14.SDR DALA2020092003112Harness · tornDURING INSPECTION FOUND HARNESS ASSEMBLY ON L1 AND R2 EMERGENCY ESCAPE SLIDES WERE FOUND TORN. CORRECTION ACTION: REPLACED HARNESS ASSEMBLY.SDR DALA2020091903111Frame · corrodedCORROSION LEVEL 2: DURING INITIAL INSPECTION FOUND CORROSION ON FRAME STA Y=1560 BETWEEN 4 RBL AND 14 RBL AT AFT CARGO COMPARTMENT. FRAME WAS REPAIRED PER ERA 587835-14.SDR DALA2020091703098Wire Harness · damagedDURING INSPECTION FOUND TORN EMERGENCY SLIDE HARNESS ASSEMBLY ON PASSENGER R4 DOOR. CORRECTIVE ACTION: REPLACED EMERGENCY SLIDE HARNESS ASSEMBLY.SDR DALA2020091603087Skin · dentedDURING INITIAL INSPECTION FOUND DENT AND PROTUBERANCE ON EXTERNAL FUSELAGE SKIN FS 620, S16L NEAR TO PREVIOUS REPAIR. EXTERNAL FUSELAGE SKIN FS 620 S16L WAS REPAIRED PER ER/A 587829-14.SDR DALA2020091603086Handle · brokenDURING LIFT AND LOCK THE ROUND CRANK HANDLE RIGHT WAS BROKEN AT OFF WING EMERGENCY ESCAPE SYSTEM. CORRECTIVE ACTION: BROKEN RIGHT HANDLE, PIN AND PAD AT OFF WING EMERGENCY ESCAPE SYSTEM WAS REPLACED.SDR DALA2020091503069Fitting · misinstalledDURING SLIDE INSTALL OF L3 DOOR GIRT BAR DOES NOT ENGAGE ON THE FLOOR FITTING AT CABIN PAX. FOUND FLOOR FITTING AT L3 DOOR INSTALLED CORRECTLY.SDR DALA2020091503068Floor Support · corrodedDURING INITIAL INSPECTION FOUND LEVEL 2 CORROSION ON FLOOR SUPPORTS (2EA) STA 1640 TO 1660 AND 1660 TO 1681 RBL58 AT PAX CABIN FLOOR STRUCTURE. REPAIRED FLOOR SUPPORTS, PER ERA 587625-14.SDR DALA2020091403053Flap System · malfunctionedWHILE ON DESCENT WITH FLAPS 1 SELECTED, THE "T/E FLAP ASYMMETRY EICAS" MESSAGE APPEARED. COMPLIED WITH THE QRH, BUT FLAPS WERE NOT RESTORED. THE INDICATOR REMAINED STUCK BETWEEN UP & 1. CORRECTIVE ACTION: MAINTENANCE DID RUN BITE AND THE FSEU FAULTED THE LESDR DALA2020091403060Support · corrodedCORROSION LEVEL 2, DURING INITIAL INSPECTION CORRISION WAS FOUND ON SUPPORT ON STA 1440 BETWEEN S-29R AND S-30 AT AFT CARGO COMPARTMENT. SUPPORTS WERE REPLACED, PER SRM.SDR DALA2020091403059Fitting · damagedDURING INITIAL INSPECTION FOUND FWD/AFT FLOOR FITTING TO VERIFY A MINIMUM ENGAGEMENT. GIRT BAR WAS REPLACED AT L4 DOOR SLIDE FITTINGS. SYSTEM OPERATION IS NORMAL.SDR DALA2020091413055Floorbeam · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION ON FLOOR STRINGER S-RBL 16.10, 7.55 AND 2.90 STA 650 AT FWD CARGO COMPARTMENT. REPAIRED PER ERA.SDR DALA2020091103032Floorbeam · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION ON FLOOR STRINGER S-LBL 16.10, 10.45, 7.55, 2.90 STA 650 AT FWD CARGO COMPARTMENT. STRINGER REPAIRED PER SRM.SDR DALA2020091103031Crease Beam · crackedDURING INSPECTION FOUND CRACK ON CREASE BEAM TRUSS AT STA 418 AND 65 LBL PASSENGER CABIN. REPAIRED PER ERA 587698-14.SDR DALA2020091103030Strap · crackedDURING INSPECTION FOUND CRACKED STRAP SUPPORT ON CEILING AREA RIGHT SIDE AT STA 720 AT FWD CARGO COMPARTMENT. STRAP WAS REPAIRED PER SRM 53-00-51.SDR DALA2020091103029Hinge · missingDURING INSPECTION FOUND MISSING UPPER HINGE HALF OF ESCAPE SLIDE AT R3 DOOR AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA2020091103028Hinge Fitting · missingDURING INSPECTION FOUND UPPER HINGE HALF OF ESCAPE SLIDE AT R3 DOOR MISSING AND REPLACED.SDR DALA2020091113026Support · corrodedDURING INSPECTION FOUND CORROSION LEVEL 2 ON SUPPORTS (2EA) OF WASTE TANK PANEL STA 1545 AND 1557 STR 29 RT AFT CARGO COMPARTMENT (C2) AND REPLACED PER SRM.SDR DALA2020091003025Frame · corrodedDURING INITIAL INSPECTION CORROSION LEVEL 2 FRAME CLIP STA 1560 BETWEEN STR 26-27 RT WAS REPLACED.SDR DALA2020091003024Floor Support · corrodedINITIAL INSPECTION FOUND CORROSION LEVEL 2, INTERCOSTAL ON STA 1520 TO 1540 RBL 4 WAS REPAIRED (PERMANENT REPAIR ), PER ER/A 587708-14.SDR DALA2020091003023Floor Support · corrodedDURING INSPECTION FOUND LEVEL 2 CORROSION ON FLOOR SUPPORT AT STA 1660/1681, WAS REPAIRED ER/A 587628-4.SDR DALA2020091093022Floor Support · corrodedDURING INSPECTION FOUND CORROSION ON FLOOR SUPPORT STRINGER LBL 2.90 STA Y=780+62 AT FWD CARGO COMPARTMENT. CORROSION LEVEL: 2 WAS OUT OF LIMITS AND WAS REPAIRED.SDR DALA2020090902996Floor Support · corrodedCORROSION LEVEL: 2 DURING INSPECTION FOUND CORROSION OUT OF LIMITS ON FLOOR SUPPORT STRINGER RBL 10.45 STA Y= 780+62 AT FWD CARGO COMPARTMENT AND REPAIRED.SDR DALA2020090902995Floor Support · corrodedCORROSION LEVEL: 2 DURING INSPECTION FOUND FLOOR SUPPORT STRINGER RBL 7.55 STA Y= 780+62 AT FWD CARGO COMPARTMENT CORROSION OUT OF LIMITS AND RREPAIRED PER SRM.SDR DALA2020090902994Floor Support · corrodedCORROSION LEVEL: 2 DURING INSPECTION FOUND CORROSION OUT OF LIMITS ON FLOOR SUPPORT STRINGER RBL 2.90 STA Y= 780+62 AT FWD CARGO COMPARTMENT AND REPAIRED.SDR DALA2020090902993Floor Support · corrodedCORROSION LEVEL: 2 DURING INSPECITON FOUND CORROSION OUT OF LIMITS ON FLOOR SUPPORT STRINGER LBL 7.55 STA Y= 780+62 AT FWD CARGO COMPARTMENT AND REPAIRED PER SRM.SDR DALA2020090902992Floor Support · corrodedCORROSION LEVEL: 2 FOUDN CORROSION ON FLOOR SUPPORT STRINGER LBL 10.45 STA Y= 780+62 AT FWD CARGO COMPARTMENT AND REPAIREDSDR DALA2020090902991Floor Support · corrodedCORROSION LEVEL: 2 DURING INSPECTION FOUND CORROSION OUT OF LIMITS ON FLOOR SUPPORT STRINGER LBL 16.10 STA Y= 780+62 AT FWD CARGO COMPARTMENT AND REPAIRED PER SRM
Back to Boeing 757-351