Boeing 767-300
Service difficulty reports · 2,148
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA202608191160Floor Panel · damagedBROKEN FIBERS AROUND THE CENTER CUT-OUTS OF THE FLOOR PANEL 241WFF IN THE MAIN DECK CARGO BAY. (14 LOCATIONS) FLOOR PANEL 241WFF IN THE MDC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4-B FIG 201, SHEET 2 REV 94.SDR FDEA202608191159Floor Panel · puncturedPUNCTURE AROUND PREVIOUS REPAIR ON FLOOR PANEL 231FFF IN THE MAIN DECK CARGO BAY. (ONE LOCATION) FLOOR PANEL 231FFF IN THE MDC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4.B FIG 201, SHEET 2 REV 94.SDR FDEA202608191158Floor Panel · puncturedPUNCTURED FLOOR PANEL 241ZFF (QTY 1) IN THE MAIN DECK CARGO BAY FLOOR PANEL 241ZFF IN THE MDC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4.B FIG 201, SHEET 2 REV 94.SDR FDEA202608191157Floor Panel · damagedBROKEN FIBERS ON THE OUTER SURFACE OF THE FLOOR PANEL 242SFF IN THE MAIN DECK CARGO BAY. (ONE LOCATION) FLOOR PANEL 242SFF IN THE MDC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4.B FIG 201, SHEET 2 REV 94.SDR FDEA202608191155Floor Panel · dentedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 251PFF HAS PUNCTURE DAMAGE. JM18 REPAIRED MAINDECK CARGO FLOORPANEL 251PFF MPN: 146T5869-169 LBL 54.75 - LBL 77.50 STA 1208-1370 IN REF TO B767 SRM 53_00_50_2R_0 PAR 4.D. SEE JPF FOR ALL WORK ACCOMPLISHED THIS IS A SDR FDEA202608191153Floor Panel · puncturedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 231KFF HAS PUNCTURE DAMAGE. FABRICATED NEW FLOOR PANEL 231KFF, MPN 143T5876-64, LBL 77.5 -LBL 86.5 , STATION 544-654 22 IN REF TO BOEING DWG 143T-5876-64. THIS IS A MAJOR REPAIR. INSTALLATION OF THIS PANEL WILL BE SDR FDEA202608191152Floorboard · puncturedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 231PFF HAS PUNCTURE DAMAGE. FABRICATED FLOORBOARD 231PFF (MPN: 143T5876-129) REF BOEING DWG 143T5876-129 AND FEDEX DWG SR67-53-009. SEE JPF FOR WORK STEPS PERFORMED. THIS IS A MAJOR REPAIR.SDR FDEA202608181151Floorboard · puncturedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 251KFF HAS PUNCTURE DAMAGE. FABRICATED FLOORBOARD 251KFF (MPN: 146T5869-9) REF BOEING DWG 146T5869-9 AND FEDEX DWG SR67-53-009. SEE JPF FOR WORK STEPS PERFORMED. THIS IS A MAJOR REPAIR.SDR FDEA202608181150Floor Panel · damagedBROKEN FIBERS ON THE SURFACE OF FLOOR PANEL 231DFF IN THE MAIN DECK CARGO BAY (TWO LOCATIONS) FLOOR PANEL 231DFF MAIN DECK CARGO BAY WAS REPAIRED IAW RM 53-00-50- 2R PAR 4-B, FIG 201 SHEET 2 REV 94.SDR FDEA202608181149Floor Panel · dentedDENTS AROUND PREVIOUS REPAIR ON FLOOR PANEL 231CFF IN THE MAIN CARGO BAY(THREE LOCATIONS) FLOOR PANEL 231CFF MAIN DECK CARGO BAY WAS REPAIRED IAW B767 SRM 53-00-50- 2R PAR4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608181148Floor Panel · damagedBROKEN FIBERS ON FLOOR PANEL 221GFF IN THE MAIN DECK CARGO BAY. (TWO LOCATIONS) FLOOR PANEL 221GFF MAIN DECK CARGO BAY WAS REPAIRED IAW \SRM 53-00-50- 2R PAR 4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608181147Floor Panel · damagedBROKEN FIBERS ON THE SURFACE OF FLOOR PANEL 231BFF IN THE `MAIN DECK CARGO BAY (ONE LOCATION) FLOOR PANEL 231BFF MAIN DECK CARGO BAY WAS REPAIRED IAW SRM 53-00-50- 2R PAR 4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608181145Floor Panel · puncturedPUNCTURED SURFACE OF FLOOR PANEL 231EFF IN THE MAIN DECK CARGO COMPARTMENT (FOUR LOCATIONS) FLOOR PANEL 231EFF MAIN DECK CARGO COMPARTMENT WAS REPAIRED IAW B767 SRM 53-00-50- 2R PAR 4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608181141Skin Panel · dentedDENT ON RH LWR HORIZONTAL IB FWD SKIN APPLIED PERMANENT REPAIR AT RH LWR HORIZONTAL I/B FWD SKIN IAW B757 SRM 51-70-10-2R REP 4SDR 2026FA0000646Not Reported · not reportedFAA FORM 8110-3 MF02972R0211SDR 2026FA0000645Not Reported · not reportedFAA FORM 8110-3 FVCI EO# 26030-1 REV."IR"SDR IPXA2026090413630Radome · erodedRADOME HAS EROSION ON CAPTAIN€™S SIDE. REMOVE THE EROSION MATERIALS AND CLEAN. BOND THE REPAIR PLIES WITH FILM ADHESIVE CURED AT 260°F FOR 100 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG. INSTALL RADOME BOOT I.A.W. UPS EO-35385-JIC001 REV. 4. I.A.W AMM 53-12-01-SDR FDEA202608141124Skin · dentedDENT ON LOWER SKIN OF OUTBOARD FLAP AT 13" FROM INBD EDGE AND 43" FROM TRAILING EDGE LH WING WING LH ON OUTBOARD FLAP, LOWER SKIN AT 13" FROM INBD EDGE AND 43" FROM TRAILING EDGE WAS REPAIRED IAW B767 SRM 57-53-10-01-1A FIG. 101 SHEET 4 AND SRM 51-70-10-2RSDR FDEA202608141123Floor Panel · puncturedONE PUNCTURE ON FLOOR PANEL 242CFF MDC FLOOR PANEL 242CFF MDC WAS REPAIRED IAW SRM 53-00-50-2R, PAR 4-B, FIG 201, SHEET 2, REV 94.SDR FDEA202608141122Floor Panel · puncturedPUNCTURE ON FLOOR PANEL 242HFF MDC FLOOR PANEL 242HFF MDC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4-B, FIG 201, SHEET 2, REV 94.SDR FDEA202608141121Skin · dentedDENT ON INBD MAIN FLAP L.E., AT 8'' FROM OUTBD EDGE, RH WING. RH WING, ON INBD MAIN FLAP L.E. AT 8'' FROM OUT BD EDGE, WAS EVALUATED IAW SRM 57-53-01-1A AND REPAIRED IAW SRM 51-70-17-0G FIG.1 AND 2 PARAG 3C (2) REV, 94.SDR FDEA202608141120Floor Panel · puncturedPUNCTURE ON FLOOR PANEL 241 DFF MDC FLOOR PANEL 241 DFF WAS REPAIRED IAW SRM 53-00-50-2R PAR. 4-B, FIG. 201, SHEET 2, REV 94.SDR FDEA202608131119Floor Panel · puncturedONE PUNCTURE ON FLOOR PANEL 241WFF MDC FLOR PANEL 241WFF MDC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608111113Floor Panel · crackedCRACKS (10EA) ON UPPER SURFACE OF FLOOR PANEL 241WFF AT MDC SEC 45. FLOOR PANEL 241 WFF AT MDC SEC 45 WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4-B FIG.201 SHEET 2 REV. 94SDR ABXA20260808357Flt Controls · not reportedCREW CALLED FLIGHT CONTROL AND REPORTED AN ABORTED TAKEOFF (ATO) DUE TO THE THRUST MANAGEMENT NOT ENGAGING. FLIGHT CONTROL, THE CAPTAIN AND A MAINTENANCE CONTROLLER CONFERENCED TOGETHER AND DETERMINED THAT THE CREW NEEDED TO COMPLETE A DEFFERAL FOR THE THRUST SDR FDEA202608071097Floor Panel · puncturedTWO PUNCTURE ON FLOOR PANEL AT MDCC FLOOR PANEL 231LFF AT MDCC WAS REPAIRED IAW SRM 53-00-50-2R PAR. 4-B FIG. 201, SHEET 2 REV .94.SDR FDEA202608071096Floor Panel · puncturedPUNCTURED FLOOR PANEL 241FFF IN THE MAIN DECK CARGO COMPARTMENT FLOOR PANEL 241 FFF MAIN DECK CARGO COMPARTMENT WAS REPAIRED IAW SRM 53-00-50-2R, PAR 4-B, FIG.201, SHEET 2 REV.94.SDR FDEA202608071095Floor Panel · brokenBROKEN FLOOR PANEL 251PFF ON MDCC. REPAIRED IAW SRM 53-00-50-2R, PAR 4-B, FIG 201, SHEET 2, REV 94.SDR FDEA202608071093Floor Panel · puncturedPUNCTURE ON FLOOR PANEL 232LFF AT MDCC FLOOR PANEL 232LFF AT MDCC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4-B FIG 201 SHEET 2, REV 94.SDR FDEA202608071092Floor Panel · brokenBROKEN FLOOR PANEL 241PFF AT MDCC FLOOR PANEL 241PFF AT MDCC WAS REPAIRED IAW SRM 53-00-50-2R PAR 4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608061091Floor Panel · puncturedPUNCTURE ON FLOOR PANEL 241KFF AT MDCC FLOOR PANEL 241KFF AT MDCC WAS REPAIRED I.A.W. SRM 53-00-50-2R PAR 4-B FIG 201 SHEET 2 REV 94.SDR FDEA202608041084Loop · inoperativeEVAS GLARESHIELD HOOK & LOOP ON LT & RT SIDE REQUIRES REPLACEMENT. HOOK & LOOP IS COMPLETELY WORN OUT. INSTALLED NEW HOOK & LOOP FOR BOTH CAPT'S AND F/O'S EVAS SYSTEMS IAW AMM 25-99-99-8-0 . OK FOR SERVICESDR IXXA20260803001Stiffener · chafed#1 PYLON HYDRAULIC BAY LOWER RIBS ARE CHAFFED FROM HYDRAULIC SUPPLY HOSE.SDR FDEA202607311073Skin · dentedTHREE DENTS ON LOWER SURFACE OF OUTBOARD FLAP RH ON AREA BTW 6'' TO 11'' FROM INBOARD FAIRING AND BTW 22'' TO 30'' FROM AFT EDGE. DENTS ON LOWER SURFACE OF OUTBOARD FLAP ON AREA BTW 6'' TO 11'' FROM INBOARD FAIRING AND BTW 22'' TO 30'' FROM AFT EDGE, WAS ESDR FDEA202607311061Floor Panel · brokenBROKEN 241WFF FLOOR PANEL, MAIN DECK CARGO COMPARTMENT FLOOR PANEL 241WFF, MAIN DECK CARGO COMPARTMENT WAS REPAIRED IAW B767 SRM 53-00- 50-2R PAR 4-B FIG 201 SHEET 2 REV 94 DEC 15/2025SDR FDEA202607291058Floor Panel · brokenBROKEN 242SFF FLOOR PANEL ON MAIN DECK CARGO COMPARTMENT FLOOR PANEL 242SFF ON MAIN DECK CARGO COMPARTMENT WAS REPAIRED IAW B767 SRM 53- 00-50-2R PAR 4-B FIG 201 SHEET 2 REV 94 DEC 15/2025SDR FDEA202607281047Floor Panel · dentedDENT, 242MFF FLOOR PANEL, MAIN DECK CARGO COMPARTMENT 242MFF FLOOR PANEL MAIN CARGO COMPARTMENT WAS REPAIRED IAW SRM 53-00-50-2R PAR. 4- B FIG. 201 SHEET 2 REV. 94 DEC 15/2025SDR FDEA202607281046Floor Panel · puncturedPUNCTURE ON 241AGF FLOOR PANEL, MAIN DECK CARGO COMPARTMENT ON 241AGF FLOOR PANEL, MAIN DECK CARGO COMPARTMENT WAS REPAIRED I.A.W. B767 SRM 53-00-50-2R PAR 4-B FIG 201 SHEET 2 REV 94 DEC 15/2025SDR FDEA202607271045Floor Panel · damagedPUNCTURES ON FLOOR PANEL 241 KFF AT MDCC (2EA). FLOOR PANEL 241 KFF AT MDCC WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV 94 DEC 15/2025SDR IPXA2026072756797Hinge · brokenL1 DOOR LOCK GUARD HINGE BROKEN REMOVED AND REPLACED L1 DOOR LOCK GUARD HINGE ASSY IAW AMM 52-12-00. NO DEFECTS TO NOTESDR FDEA202607241029Floor Panel · puncturedTWO PUNCTURES ON FLOOR PANEL 231FFF ON MAIN DECK CARGO COMPARTMENT. FLOOR PANEL 231FFF ON MDC WAS REPAIRED IAW B767 SRM 53-00-50-2R FIG.201 SHEET 2 PAR 4.B REV.94 DEC 15/2025SDR FDEA202607241028Floor Panel · crackedFOUR CRACKS ON FLOOR PANEL 242SFF ON MAIN DECK CARGO COMPARTMENT. FLOOR PANEL 242SFF ON MDC WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR.4.B FIG.201 SHEET 2 REV.94 DEC 15/2025SDR FDEA202607241027Floor Panel · crackedPUNCTURE ON FLOOR PANEL 231DFF ON MAIN DECK CARGO COMPARTMENT. FLOOR PANEL 231DFF ON MDC WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG.201 SHEET 2 REV.94 DEC 15/2025SDR FDEA202607241019Floor Panel · puncturedPUNCTURES (2EA) ON FLOOR PANEL 231LFF. MDC SECT 43. FLOOR PANEL 231LFF. MDC SECT 43 WAS REPAIRED I.A.W. SRM 53-00-50-2R PAR.4-B FIG.201 SHEET 2 REV.94 DEC.15/2025.SDR FDEA202607231017Access Panel · crackedCRACKS ON ACCESS PANEL 241 WFF AT MDCC ACCESS PANEL 241 WFF AT MDCC WAS REPAIRED IAW B767 SRM 53-00-50-2R FIG 201 REP GEN SHEET 2 REV 94 DEC 15/2025SDR FDEA202607231016Access Panel · crackedCRACK ON FLOOR ACCESS PANEL 241 JFF AT MDCC FLOOR PANEL 241 JFF AT MDCC WAS REPAIRED IAW B767 SRM 53-00-50-2R FIG 201 REP GEN SHEET 2 REV 94 DEC 15/2025SDR FDEA202607231015Floor Panel · puncturedA PUNCTURE ON FLOOR PANEL 251AFF OF MAIN DECK CARGO. FLOOR PANEL 251AFF OF MAIN DECK CARGO COMPARTMENT WAS REPAIRED IAW B767 SRM 53- 00-50-2R PAR 4-B FIG. 201 SHEET 2 REV. 94 DEC 15/2025.SDR FDEA202607231014Skin · dentedDENT ON INTERNAL SURFACE OF SLAT NO. 8 AT 72.5" FROM INBOARD EDGE AND 7" FROM TRAILING EDGE, RIGHT WING. SLAT NO. 8 AT 72.5" FROM INBOARD EDGE AND 7" FROM TRAILING EDGE, RIGHT WING WAS REPAIRED IAW B767 SRM 51-70-10-2R REPAIR 4 REV. 94 DEC 15/2025SDR FDEA202607231010Floor Panel · damagedPUNCTURE ON ACCESS FLOOR PANEL 242 FFF AT MDCC. ACCESS FLOOR PANEL 242 FFF AT MDCC WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR 4.G(2). REV 94 DATE DEC 15 2025.SDR IPXA2026072693391Rub Strip · chafedFAULT - CHAFING - STRIP, NO.2 ENG R/H CORE COWL INNER T/E UPR AREA. (REPLACE). INSTALL NEW WEAR STRIP I.A.W SRM 51-40-02-0G REV.95 AND GOODRICH AEROSTRUCTURES CMM IPL 71-13-24 REV. 51. REVIEW COMPLETE
Back to Boeing 767-300