Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011060602745Pump · leakingNR 2 ENGINE HYD PUMP LEAKING AT MATING SURFACES. REPLACED NR 2 EDP PER MM. GROUND RUN OKAY.SDR UALA2011060602778Battery · faultyMAIN BATTERY CHARGER EICAS STATUS MSG. REPLACED BATTERY PER MM. OPS OKAY.SDR UALA2011060602777Charger · faultyMAIN BATTERY CHARGER STATUS MSG UNABLE TO CLEAR. REPLACED MAIN BATTERY CHARGER PER AMM. MESSAGE CLEARED AND ALL INDICATIONS NORMAL.SDR UALA2011060602775Handset · inoperativePURSER UNABLE TO CALL COCKPIT FROM DOOR 1L. REPLACED HANDSET AT 1L, OPS CHECK. GOOD.SDR UALA2011060302730Stick Shaker · malfunctionedSTICK SHAKER X4 WITH FLAPS DOWN & THROTTLES AT IDLE. TEST FLOWN FOR SHAKER.OPS NORMAL. SHAKER CHECKED AT FLAPS 0' 5 AND 30. NOTED FOR SFOEG. DIAGNOSTIC TEST FLIGHT: DUE TO REPEAT GRIPES OF THE STICK SHAKER GOING OFF AT VARIOUS FLAP SETTINGS, A DIAGNOSTIC TESTSDR UALA2011060302727Panel · missingNR 6 L/E SLAT LWR TRAILING EDGE FAIRING SECTION MISSING. REPLACED NR 6 L/E SLAT LOWER PANEL.SDR UALA2011060602748Light · brokenSEAT AISLE SIDE EEL STRIP 2B BROKEN. REPLACED LIGHT STRIP. CHECKS OKAY.SDR UALA2011060302712Power Supply · inoperativeEMERGENCY PATH LIGHTS RT AISLE L896, LT AISLE L897, AND CROSS AISLE PATH LIGHT L905 ARE INOPERATIVE. REPLACED RT AISLE PATH LIGHT L896, CHECKED OKAY. REPLACED POWER SUPPLY M1559 FOR L897 AND L905, CHECKED OKAY.SDR UALA2011060302706Fan · faultyEICAS MSG' FWD EQPT OVHT' DISPL &'OVHT' LGT ILLUM AFTER SELECTION WAS POS TO 'STBY' LGT RE-ILLUM FOLLOWING 5 MIN DELAY. SELECTION WAS POS TO 'OVRD' EICAS MESSAGE 'FWD EQPT COOLING' DISPL & 'NO COOLING' LGT. REPLACED EXHAUST FAN AND MONITOR.SDR UALA2011060302726Windshield · scratchedCAPTAIN'S WINDSHIELD'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. CREW COMMENTS: SCRATCHES AFFECT VISIBILITY SCRATCHES FROM WINDSHIELD WIPER. REPLACED CAPTAINS 1L WINDOW REF MM AND INSPECTION, ALL OPS CHECK SATISFACTORY.SDR UALA2011060302714Circuit Card · faultyLEFT ENG SPEED CARD IS FAULTY. REPLACED LEFT SPEED CARD.SDR UALA2011060302713Control Valve · faultyHI FLOW INHIBIT EICAS STATUS MESSAGE. REPLACED FLOW CONTROL VALVE.SDR UALA2011060302715Wire · chafedADP INOPERATIVE. ADP REPLACED, NO HELP. INOP IN AUTO AND ON POSITION. REVIEWED HIS, ACPED TS PER WDM. RPLED K684 & K443 AND ACPED SYS RESET AT S572. FOUND CHAFED WIRED AT PUMP CONNECTOR, RPRED WIRE AND WRAPPED HARNESS TO ISOLATE FROM PIPING, SYSTEM CHECKEDSDR UALA2011060302711Actuator · leakingL HYD LOW ON TAXI IN RF .63 INDICATED. FOUND CENTER RUDDER PCA LEAKING ACTUATOR. APPLIED SEALANT ON THE ACTUATOR. LEAKING 26 DROP PER MN WITHIN LIMITS AS PER AMM. OK TO CONTINUE. ACCESS PANEL 324JL.SDR UALA2011060202679Controller · faultyRT ENG BLEED, RTFL. REPLACED HPSOV CONTROLLER. ACCOMPLISHED ITEM B.2 HPSOV-HPC SYSTEM CHECK. HPSOV-HPC SYSTEM TEST PASSED CHECK. REPLACED PRV CONTROLLER PER AMM FOR TROUBLESHOOTING. REPLACED THE PRESSURE REGULATING SHUTOFF VALVE. (P/N 773288-7-8-10 (S/N 1SDR UALA2011060102671Terminal · shortedDURING NR 1 ENG START VALVE LIGHT FAILED TO COME ON, PANEL TEST OKAY. FOUND HIGH RESISTANCE ON CONNECTOR D10970 PINS 2 AND 5 REF WD. FOUND TERMINAL LUG GD6597-DC LOOSE, CLEANED AND TIGHTENED LUG, OPERATIONS CHECKED NORMAL.SDR UALA2011060202698Hose · blownRIGHT HYD QTY SHOWS .33. FOUND NR 7 MAIN BRAKE HOSE BLOWN. REPLACED NR 7 MAIN BRAKE HOSE PER MM. REFILLED HYD SYSTEM, OPS NORMAL.SDR UALA2011060202697Wire · chafedFOUND CHAFED AND EXPOSED ELEC WIRES AT COCKPIT HYDR CONTROL PANEL. SPLICED WIRES IAW SWMP, MOIST RESISTANT. ALL SATIS NOW.SDR UALA2011060202680Light · damagedSEAT 2B EMERGENCY ESCAPE PATH LIGHTING ONE LIGHT IS DAMAGED OTHER LIGHT WORKS NORMAL. SEAT 2B FWD EEL LIGHT FOUND BROKEN AND TAPED UP. SECURED CONNECTOR. REPLACED SEAT 2B FWD EEL LIGHT. OPS CHECK GOOD.SDR UALA2011060102672Valve · faultySTATUS MSG R IDG VALVE ON DURING FINAL APPROACH. RT IDG VALVE DEF OPEN. REPLACE PRESS SW D11536 ON HISTORY NO HELP, REPLACED IDG AIR OIL HEAT EXCHANGER AND VALVE. LEAK CHECK AND TEST 3 IDLE ALSO GOOD.SDR UALA2011053102611Bulb · looseODOR IN AFT GALLEY, FLIGHT DIVERTED. FOUND LIGHT ASSY IN FWD LAV CAUSING CIRCUT BREAKER TRIPPED. ACCOMPLISHED PACK BURN PRECAUTIONARY. NO INDICATIONS OIL CONTAMINATION AT THIS TIME. REMOVED COLLAR ON CIRCUT BREAKER FOR TROUBLSHOOTING. USING WDM 33-24-11 ISOLASDR UALA2011053102610Connector · damagedWINDOW HEAT PROBLEM. POWER TERMINAL LUG SCREW AT BOTTOM LEFT CORNER IS MISSING PROTECTIVE CAP. INSTALLED NEW CAP. GROUND CREW REPORTS WINDOW 3 RT MISSING WINDOW HEAT TERMINAL CAP. INSTALLED 3R WINDOW TERMINAL CAP SATISFACTORILY. GROUND CREW REPORTS WINDOW 1 RSDR UALA2011060102678Amplifier · faultySATCOM LOW GAIN SYSTEM INOPERATIVE. HIGH GAIN SYSTEM OPERATES NORMALLY, RESET, NO HELP. TRIED NEW HIGH POWER AMP LGA SYSTEM AND NEW SAT DATA UNIT, NO HELP. OLD UNITS REINSTALLED. NO BITE FAILURES, CANNOT LOG ON TO LOW GAIN SYSTEM. SUSPECT LOW GAIN ANTENNA PCNSDR UALA2011053102609Shutoff Valve · faultyRT ENG (BLEED) OFF LIGHT ON & R ENG BLEED OFF EICAS MSG, WITH ENG RUNNING, ENG BLEED SW ON, L & R ISOL VLVS CLSD, AC PACK SELECTED ON, & DUCT PSI IS ZERO. OFF LIGHT STAYS ON WHEN N1 IS ABOVE 41 PERCENT. REPLACED PRV AND RESET HP VALVE BLEED OPS NORMAL.SDR UALA2011053102657Wire · damagedAFT GALLEY FLOOR STRIP EMERGENCY LIGHT INOP. REPAIRED DAMAGED SPLICE NEAR LIGHT STRIP PER WDM, OP CHECKED GOOD.SDR UALA2011053102656Battery Pack · inoperativeSEAT MOUNTED EMERGENCY LIGHTS AT SEATS 10AB THRU 17AB INOP. REPLACED BATTERY PACK M1558 PER MM, OP CHECKED GOOD.SDR UALA2011053102655Lamp · inoperativeEMERGENCY AISLE LIGHT AT SEATS 17AB INOP. RELAMPED, OP CHECKED GOOD.SDR UALA2011053102651Light · missingSEAT 21B APPROX 12'' LONG AND ONE HALF OF LIGHT HAS AN ORANGE STRIPE IS MISSING. REPLACED SEAT MOUNTED LIGHT STRIP. GROUND CHECKED GOOD.SDR UALA2011053102642Light · looseEEL LIGHT SEGMENTS LOOSE AT SEAT 4B. SUPPLEMENTAL DATA UPDATE REPLACED ADHESIVE AND SECURED SEGMENTS.SDR UALA2011053102660Pump · inoperativeRIGHT AFT BOOST PUMP CIRCUIT BREAKER FOUND POPPED. MADE INOPERATIVE PUMP PER MEL 2822N. REPLACED RT AFT BOOST PUMP REF MM, TESTS OKAY.SDR UALA2011053102648Valve · faultyFWD EQUIPMENT VALVE LT AND EICAS. REPLACED SUPPLY VALVE, MESSAGE CLEARED.SDR UALA2011053102647Light · missingSEAT 21B EMERGENCY LIGHT STRIP ON SEAT IS TORN OFF AND MISSING. REPLACED LIGHT.SDR UALA2011053102641Light · unsecureLEFT SIDE SEAT 1H EMERGENCY LIGHT STRIP KEEPS COMING OFF. REPLACED ADHESIVE AND SECURED.SDR UALA2011052702584Rudder · warning lightRUDDER RATIO LIGHT ILLUMINATED, FLIGHT DIVERTED. EICAS MESSAGE RUDDER RATIO DISPLAYED. LIGHT EICAS CAME ON IMMEDIATELY AFTER TAKEOFF. RE-ALIGNED ALL IRU'S. BITE CHECKED YAW DAMP MODULES OK. RUDDER RATIO CHARGE MODULES IN NORM. PERFORMED FIM 27-21-709-004 SDR UALA2011052702590Acm · overheatedLT PACK TEMP EICAS DISPLAYED. NO RESET PER CHECK LIST. REPLACED LEFT PACK ACM PER MM.SDR UALA2011052602575Feeder Cable · damagedEMERGENCY LIGHTS INOP SEATS 3, 4, 5, 6. FOUND EEL POWER CABLE CUT FROM POWER SEAT UNDER SEAT 3. REPAIRED AND SECURED. OPS GOOD.SDR UALA2011052602578Adc · faultyADC FAILURE, FLIGHT DIVERTED. MCDP PREV FLT FAULTS: FD BAR FMC L-R CH (110071120081) (110081120071) FD BAR ADC SYST L (110401) FD BAR IRU L (110551) FD BAR ADC L-R CH (122080). REPLACED BOTH LT AND RT ADC PER MM AND PERFORMED LOW RANGE LEAK TEST ON BOTH ADCSDR UALA2011052502574Transceiver · failedWX RADAR FAIL AND RT FLAG. REPLACED WEATHER RADAR TRANSCEIVER IAW AMM, OPERATION NORMAL.SDR UALA2011052502559Battery · inoperativeAFT LEFT AND RIGHT LARGE WHITE EXIT SIGNS ARE INOPERATIVE. REPLACED BATTERY. CHECKED GOOD.SDR UALA2011052502551Cable · burnedAFT GALLEY NEW TECH CART CABLES P52, P61 & P62 HAVE BURNT PINS. REPLACED CABLE ASSEMBLIES, OPS CHECK NORMAL.SDR UALA2011052402534Panel · crackedNR 6 SLAT HAS CRACK 1-2 INCH LONG 4 & 7-8 INCH O/B OF I/B EDGE AND DAMAGE 9" OB OF IB EDGE 1" LONG AND 1 1-2" WIDE. REMOVED & REPAIRED PANEL PER SRM. INSTALLED AND PAINTED PANEL.SDR UALA2011052502550Battery Pack · inoperativeLH AFT MED EMERGENCY EXIT IDENTIFIER AND FLOOR STRIP NEXT TO LAV INOPERATIVE. REPLACED BATTERY PACK PER MM, OP CHECKS NORMAL.SDR UALA2011052402535Wire · brokenMCP FAULT. FOUND AUTOPILOT ANNUNCIATOR LIGHT L19 FAULTING. TRIED GOOD UNIT FCC L & R PASSED TEST 1. C FCC FAULTING NO INFC FCC C MCP A-P EN G DISC AND NO INFC FCC C MCP A-P ARM IN. PER FIM 28 V DC PRESENT AT PINS 7 ALL CONNECTORS. ACCOMPLISHED WIRING CHECKS SDR UALA2011052502547Light · brokenSEAT 1B, FOUND FWD EEL STRIP BROKEN. REPLACED AND OP-CHECK SATISFACTORY.SDR UALA2011052502553Generator · crackedAPU OIL QTY STATUS MESSAGE SAMC TEXT: BRUMM SERVICED APU AND FOUND OIL LEAK FROM CRACK IN APU GENERATOR HOUSING. REPLACED APU GENERATOR IAW AMM.SDR UALA2011052502546Audio Panel · faultyCAPT AUDIO PANEL VHF L VOLUME TOO LOW AT FULL THROW. REPLACED CAPT AUDIO PANEL AND OPS CHECK SATISFACTORY.SDR UALA2011052402543Switch · unknownSTANDBY PWR AND BATTERY SWITCH OVERHEAD MODULE ASSEMBLY ON P5 PILOTS OVERHEAD PANEL REMOVED TO SERVICE 6452. SERIAL NUMBER REMOVED IS D00855. NEW SW UNIT INSTALLED AS PER MM, ALL OPS OKAY.SDR UALA2011052402531Unknown · leakingCREW REPORT: APU OIL QTY STATUS MESSAGE. SUPPLEMENTAL DATA UPDATESDR UALA2011052402533Panel · damagedLEFT LOWER WING PANEL HALF MOON SHAPE 3' AFT 2' OTBD OF LANDING LIGHT LENS. HAS 16 AND 1-4 INCHES OF ITS L/E MISSING. PANEL IS 20 AND 3-4 INCHES WIDE. PANEL (511CB) REMOVED & SENT TO SHOP FOR REPAIR, SECURED REPAIRED PANEL TO AIRCRAFT.SDR UALA2011052402536Light · inoperativeINTERIOR EMERGENCY CEILING LIGHT INOP ABOVE SEAT ROW 32AB. REPLACED LAMP, CHECKED, OKAY.
Back to Boeing 767-322