SDR UALA2009032300872Shutoff Valve · faultyRIGHT ENG BLEED LIGHT & RT ENG HPSOV EICAS MSG DURING DESCENT WITH ENG BLEED SW ON & ENGINE RUNNING. REPLACED HPSOV.SDR UALA2009032300869Socket · shortedFOUND AFT LEFT LAV DOME SOCKET SHORTED, REMOVED POWER WIRE AND SECURED. FOUND AFT LEFT LAV DOME SOCKET SHORTED, REMOVED POWER WIRE AND SECURED. NEEDS SOCKET, NOT STOCKED ORD. REPLACED LIGHT SOCKET, OP CHECKED OKAY.SDR UALA2009032300863Hydraulic Line · leakingNR 1 ENG, OIL DRIPPING FROM LARGE DRAIN TUBE BOTTOM OF REVERSER COWL. FOUND EVIDENCE OF ACTIVE HYD LEAK INSIDE NR 1 PYLON ACCESS PLATE RT OF PYLON. FOUND TORQUE OF HYD B-NUTS AT INSIDE OF DISCONNECT PANEL OK. APPEARS TO BE COMING FROM ABOVE AND AFT OF ACCESSDR UALA2009032300871Battery · defectiveMAIN BATTERY CHARGER STATUS MESSAGE CAME ON IN DESCENT. REPLACED SHIPS MAIN BATTERY. BATTERY AND CHARGER OPS CHECK OKAY.SDR UALA2009032000852Pump · faultyEDP (ENGINE DRIVEN PUMP) HYD PWR POS 1O1=L,O2=R) EDP HYD LOW PRESS LGT ILLUM. EICAS MSG DISPLAYED (L,R) HYD PRIM PUMP. EICAS MSG (L,R) HYD SYS MAINT (WAS, WAS NOT) DISPLAYED. REPLACED NR 1 ENGINE HYDRAULIC PUMP.SDR UALA2009031900846Slide · unserviceableRT OVERWING SLIDE DEPLOYMENT BAR CLAMPS ARE BROKEN AND SLIDE UNLACED. REMOVED AND REPLACED RT OFF WING SLIDE.SDR UALA2009031900843Latch · faultyRT OVERWING COMPT DOOR INTEGRATOR TORQUE EXCEEDS 175 INCH POUNDS. REMOVED AND REPLACED 4 EACH LATCHES AND OPS CHECK GOOD.SDR UALA2009031900842Lamp · inoperativeR-2 DOOR EXTERIOR EMERGENCY LIGHT INOP. RELAMPED R2 DOOR EXTERIOR EMERGENCY LIGHT AND OPS CHECK GOOD.SDR UALA2009031900841Light · inoperativeLEFT OVERWING EMERGENCY LIGHT L642 INOP. RELAMPED LEFT OVERWING EMERGENCY LIGHT L642 AND OPS CHECK GOOD.SDR UALA2009031900840Connector · not seatedAFT EMERGENCY LIGHT BAR INOP. RESEATED CONNECTOR FOR AFT EMERGENCY LIGHT BAR AND OPS CHECK GOOD.SDR UALA2009031900839Light · inoperativeEMERGENCY LIGHT L334 AT L-2 DOOR INOP. RELAMPED EMERGENCY LIGHT L2 DOOR AND OPS CHECK GOOD.SDR UALA2009031900835Idg · faultyEICAS MSG L GEN DRIVE DISPLAYED GEN DRIVE LIGHT ILLUM, GEN DRIVE DISCONNECTED. LEFT ENGINE IDG INOP, NEEDS IDG. REPLACED NR 1 IDG.SDR UALA2009031800829Relay · faultyLEFT ENG P2-T2 PROBE HEAT CH 'A' AND CH 'B' FAULTED ON LEFT ENG PIMU. REPLACED NR 1 ENG EEC ALTERNATOR. OP'S AND LEAK CHECKED GOOD. HOWEVER, IT WAS NO HELP FOR PROBE HEAT MESSAGE. REPLACED K648, NO HELP. REPLACED K4 02, SYSTEM CHECKS GOOD.SDR UALA2009031800825Light · inoperativeFWD GALLEY FLOOR EMERGENCY LIGHT BAR INOP. REPLACED AND OPS CHECKED THE EMERGENCY LIGHT BAR.SDR UALA2009031700812Radar · inoperativeWEATHER RADAR INOP. RTFL.SDR UALA2009031600805Light · brokenCENTER LT OVERWING EMERGENCY LIGHT STRIP INOP. REMOVED BROKEN LIGHT STRIP AND REPLACED WITH SERVICEABLE LIGHT STRIP AT CENTER LT OVERWING. OPS CHECK GOOD.SDR UALA2009031600804Light · inoperativeEMERGENCY EXIT LIGHT AT ROW 38H IS INOP. REMOVED BROKEN EMERGENCY EXIT LIGHT AND REPLACED WITH SERVICEABLE EXIT LIGHT AT SEAT ROW 38. OP CHECK GOOD.SDR UALA2009031600801Cable · damagedSEAT 1B EEL INOP. REPAIRED EEL CABLE. OP CHECKED OK.SDR UALA2009031600806Connector · damagedEEL INOP BETWEEN DOOR 1L AND 1R, (CROSSAISLE) FLOOR LIGHT. REPAIRED LIGHT CONNECTION AT SIDEWALL, OPS NORMAL.SDR UALA2009031600800Connector · looseAFT GALLEY RT FLOOR STRIP EEL INOP. SECURED EEL CONNECTOR AT SEATS 41HJ, EMERGENCY LIGHTS CHECK OKAY.SDR UALA2009031600799Connector · looseLT AND RT AFT LAV FLOOR STRIP EEL INOP. SECURED EEL CABLE CONNECTORS, EMERGENCY LIGHTS CHECK OK.SDR UALA2009031600798Cable · defectiveSEATS 1B, 17H, 37H, 38H, 39H, 41H EEL INOP. REPLACED EEL CABLE AT SEATS 41HF FEEDER, EMERGENCY LIGHTS CHECK OK.SDR UALA2009031600792Light · inoperativeLT AND RT AFT MID SLIDE GROUND ILLUMINATION EMERGENCY LIGHT INOP. SECURED LAMPS, OPS CHECKS OK.SDR UALA2009031600791Light · inoperativeLOWER CEILING EMERGENCY LIGHTS AT 8A AND 40A INOP. RELAMPED EMERGENCY LIGHT.SDR UALA2009031600790Light · missingSEAT 39A MISSING EEL LIGHT. REPLACED EEL STRIP.SDR UALA2009031600788Cable · frayedRT AFT OVERWING EMERGENCY EXIT EXTERNAL STEP AFT CABLE IS FRAYED. REPLACED AFT CABLE.SDR UALA2009031300777Light · disconnectedSEAT 20A EMERGENCY LIGHT STRIP INOP. CONNECTED LIGHT STRIP AND OPS TEST GOOD.SDR UALA2009031300776Light · disconnectedSEAT 21H EMERGENCY LIGHT STRIP INOP. CONNECTED LIGHT STRIP AND OPS TEST GOOD.SDR UALA2009031300775Connector · not seatedEMERGENCY EXIT LIGHT AT ROW 12 RIGHT SIDE INOP. RESEATED CONNECTOR, OPS CHECK GOOD.SDR UALA2009031300774Connector · not seatedEMERGENCY EXIT LIGHT AT ROW 26 SEAT H IS INOP. RESEATED CONNECTOR, OPS CHECK GOOD.SDR UALA2009031300773Connector · not seatedEMERGENCY EXIT LIGHT AT ROW 11 SEAT 'B' IS INOP. RESEATED CONNECTOR AND OPS CHECK GOOD.SDR UALA2009031100752Light · missingFIRST CLASS EEL LT MISSING ROW 6B AFT LT. INSTALLED SERVICEABLE EEL LIGHT, OPS CHECKED SAME. SYS OPS NORM, RETURNED A/C BACK TO NORMAL. OK FOR SVC.SDR UALA2009031200769Rib · crackedLT WING CHORD UPPER FLANGE CRACKED 2 INCHES AT WS 304. ASSEMBLED REPAIR PIECES AND INSTALLED RIB WITH REVISED EVA UA-EVA-72388A. ACCMP'D RIB INSP.SDR UALA2009031000748Light · missingONE EMERGENCY STRIP LIGHT ON SIDE OF SEAT 3H MISSING. RELAMPED EMERGENCY LIGHT, OP CHECKED OK.SDR UALA200903100073AFeeder Cable · deterioratedNR 1 ENGINE GENERATOR FEEDERS ARE DETERIORATED AND RUBBER FEED THRU GROMMET IS DETERIORATED. REPLACED FEEDERS PER BSWPM 20-30-13 AND 20-30-11 AND 20-10-13. ALSO REPLACED RUBBER GROMMET PER BSWPM 20-10-13 AND SRM51-40-02, OPS CHECKS GOOD.SDR UALA200903100072ARod · brokenLEADING EDGE SLAT DISAGREE MSG ON EICAS. RTFL. FOUND OUTBOARD CONTROL ROD FOR LT INBOARD SLAT BROKEN. REPLACED CONTROL ROD. ACCMP INSPECTION OF ROD AND SLAT INSTALLATION.SDR UALA2009031000738Feeder Cable · deterioratedNR 1 ENGINE GENERATOR FEEDERS ARE DETERIORATED AND RUBBER FEED THRU GROMMET IS DETERIORATED. REPLACED FEEDERS PER BSWPM 20-30-13 AND 20-30-11 AND 20-10-13. ALSO REPLACED RUBBER GROMMET PER BSWPM 20-10-13 AND SRM 51-40-02, OPS CHECKS GOOD.SDR UALA2009031000732Rod · brokenLEADING EDGE SLAT DISAGREE MSG ON EICAS. RTFL.SDR UALA2009031000736Skin · damagedLT FUSELAGE APPROX STA 192 AT LAP JOINT LWR ROW HAS DAMAGED SKIN AT FASTENER FROM STATIC DISCHARGE. REMOVED DAMAGE BY OPENING HOLE TO 1 - 4 INCH AND SPOT FACING DAMAGE REMOVED .030 MATERIAL FROM OVERLAPPING SKIN. ACP REPAIR PER UA-EVA-72343 AND SRM 53-00-01 SDR UALA2009031000733Repair · erodedRT WING GEAR STRUT DOOR PREVIOUS REPAIR ERODED AND DELAMINATED AFT INBOARD CORNER.SDR UALA2009031000727Structure · crackedCRACK FOUND ON FWD RT OUTER CHORD OUTBOARD FLANGE AT STA 1809 BULKHEAD BELOW TENSION FITTING AT S12AR. MAJOR REPAIR ACCOMPLISHED. FLANGE REPAIRED. CUT OUT DAMAGED SECTION AND INSTALLED NEW SECTION OF CHORD AND STRAP REPAIR.SDR UALA2009031000713Floorbeam · corrodedFWD PIT STA 65+121 TOP CAP OF PIT FLOOR STRUCTURE CORRODED APPROX LBL 16. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF T-CAP, FABRICATED & INSTALLED REPLACEMENT T-CAP CHORD.SDR UALA2009030400713Floorbeam · corrodedFWD PIT STA 65+121 TOP CAP OF PIT FLOOR STRUCTURE CORRODED APPROX LBL 16. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF T-CAP, FABRICATED & INSTALLED REPLACEMENT T-CAP CHORD.SDR UALA2009031000711Oxygen System · low pressureCREW OXYGEN PRESSURE BELOW 3SVC LIMITS (1.610 PSI). SERVICED CREW OXYGEN SYSTEM. OP CHECKS OKAY.SDR UALA2009031000700O-Ring · leakingLEFT JETTISON PUMP IS LEAKING APPROX 8 DROPS PER MINUTE. FOUND PUMP LEAKING FUEL. REPLACED O-RINGS FOR LEFT JETTISON PUMP. CHECKS OK.SDR UALA2009031000698Lens · brokenFUSELAGE EXTERIOR EMERGENCY LIGHT LENS BROKEN RT SIDE APPROX 24 INCHES FWD OF AFT PIT DOOR. REMOVED AND REPLACED EMERGENCY LIGHT LENS.SDR UALA2009031000694Skin · damagedFOUND LIGHTNING STRIKE EXIT DAMAGE ON RUDDER TRAILING EDGE. DAMAGE IS LOCATED APPROXIMATELY 8 FEET UP FROM LOWER EDGE. DAMAGE IS A SEMI CIRCULAR DELAMINATED ARE MEASURING 2 INCH BY 1.25 INCH, CONTAINED IN CENTER IS A .75 BY 1.25 INCH AREA OF EXPOSED AND DAMASDR UALA2009030400711Oxygen System · low pressureCREW OXYGEN PRESSURE BELOW 3SVC LIMITS (1.610 PSI). SERVICED CREW OXYGEN SYSTEM. OP CHECKS OKAY.SDR UALA2009030300700Housing · looseLEFT JETTISON PUMP IS LEAKING APPROX 8 DROPS PER MINUTE. RE-TORQUED PUMP HOUSING AND LEAK CHECKED WITH 40,000 FOR 8 HRS. NO LEAKAGE NOTED.SDR UALA2009030300698Lens · brokenFUSELAGE EXTERIOR EMERGENCY LIGHT LENS BROKEN RT SIDE APPROX 24 INCHES FWD OF AFT PIT DOOR. REMOVED AND REPLACED EMERGENCY LIGHT LENS.
Back to Boeing 767-322