SDR 2008UALA02048Warning Light · false activationLEFT ENGINE FUEL FILTER LIGHT ON MOMENTARILY IN DESCENT. GOT STATUS LIGHT, CLEARED IT.SDR 2008UALA02047Engine · malfunctionedRIGHT ENG NO N1 READING ON TOUCHDOWN.SDR 2008UALA02046Hose · kinkedLT OVERWING SLIDE-BOTTLE PRESSURE HOSE IS KINKED SEVERAL SPOTS. SUSPECT HOSE MIS- STOWED DURING MAINTENANCE. REPLACED HOSE IAW SB 767-25-022. AC OK FOR SERVICE.SDR 2008UALA02039Skin · crackedNR 2 PYLON UPPER WEB FUEL LINE CUTOUT SKIN CRACKED AT NAC STA 178. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR, ACCOMPLISHED REMOVED EXISTING REPAIR DOUBLER FROM NAC STA 172 TO 178. STOP DRILLED CRACK AND ACCMP'D HFEC TO VERIFY DAMAGE REMOVED. FABRICATED AND INSTSDR 2008UALA02032Aspirator · leakingASPIRATOR LEAKS. REPLACED ASPIRATOR LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02015Shear Tie · corrodedAFT PIT LOWER FUSE FRAME SHEAR TIES HAVE CORROSION AT BS 1241 FROM STR 39R-35L. MAJOR REPAIR ACCOMPLISHED, REMOVED CORROSION AND REPLACED SHEAR TIES.SDR 2008UALA02001Light · inoperativeEEL LIGHTS AT SEATS 16HJ, AND 23HJ ARE IN-OP. SUPPLEMENTAL DATA UPDATE REPLACED STRIPS. CHECKS OKAY.SDR 2008UALA02000Light · inoperativeEEL LIGHT AT SEAT 31AB, AND 37AB INOP. SUPPLEMENTAL DATA UPDATE, REPLACED EEL STRIPS.SDR UALA2008111301963Shutoff Valve · failedPACK "OFF" LIGHT & "PACK OFF" EICAS MESSAGE DISPLAYED WITH PACK SELECTED TO AUTO. NO "PACK TEMP" OR "INOP" LIGHT DISPLAYED. RECURRED ON FLT 0059-07. REPLACED FLOW CONTROL SHUT OFF VALVE. OPERATIONAL CHECK WAS GOOD. REPLACED FLOW CONTROL CARD ASSY, CHECKS SDR 2008UALA01962Light · faultyEMERGENCY PATH LIGHTING FLICKERS ON AND OFF IN FORWARD GALLEY AND FIRST CLASS ONLY. SUPPLEMENTAL DATA UPDATE, REPLACED POWER SUPPLY BATTERY M1577. CHECKS OKAY.SDR 2008UALA01963Warning Light · illuminatedPACK "OFF" LIGHT AND "PACK OFF" EICAS MESSAGE DISPLAYED WITH PACK SELECTED TO AUTO. NO "PACK TEMP" OR "INOP" LIGHT DISPLAYED. RECURRED ON FLT 0059-07.SDR 2008UALA01960Frame · corrodedAFT CARGO COMPARTMENT AT BS 1153 AND LBL 8 -16, FRAME T-CAP IS CORRODED ON UNDERSIDE AND AROUND NUTPLATE. SUPPLEMENTAL DATA UPDATE, MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGED SECTION OF CARGO FLOOR "T" CAP. SPLICED IN NEW SECTION.SDR 2008UALA01959Frame · corrodedAFT CARGO COMPT AT BS 1197 AND LBL 20-25, FRAME T-CAP IS CORRODED AROUND NUT PLATE FASTENER HOLES. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGED SECTION OF PIT FLOOR T-CAP. SPLICED IN NEW SECTION.SDR 2008UALA01958Shear Tie · corrodedAFT PIT FRAME SHEAR TIES HAVE CORROSION BS 1395 RBL 1 AND LBL 8. SUPPLEMENTAL DATA UPDATE, MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGED SHEAR TIE. FABRICATED AND INSTALLED NEW SHEAR TIE.SDR 2008UALA01957Door Frame · corrodedAFT BULK PIT LOWER BILGE, FUSE FRAME HAS CORROSION ON LOWER AFT SIDE AT BS 1540 BETWEEN STR 38L-39L. SUPPLEMENTAL DATA UPDATE, MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGED SHEAR TIE. FABRICATED AND INSTALLED NEW SHEAR TIE.SDR 2008UALA01956Door Frame · gougedAFT BULK PIT ACCESS DOOR BOTTOM FRAME HAS GOUGE ON REPAIR DOUBLER. MAJOR REPAIR ACCOMPLISHED, REMOVED DENTED DOUBLER. FABRICATED AND INSTALLED NEW DOUBLER.SDR 2008UALA01937Idg · faultyEICAS MSG R GEN DRIVE DISPLAYED.GEN DRIVE LGT ILLUM. GEN DRIVE DISCONNECTED. REPLACED RT ENGINE IDG PER MM 24-11-01-401 RAN ENGINE OPS GOOD. AC OK FOR SERVICE.SDR 2008UALA01935Compressor · malfunctionedR ENG HPSOV EICAS. FOUND HIGH PRESSURE SHUT OFF VALVE AND HIGH PRESSURE CONTROLLER TO BE FAULTY. REPLACED NR 2 ENG HPSOV PER MM 36- 11-07 PG 401, NO HELP. BITE CHECK AIR SUPPLY CONTROLLER. REPLACED NR 2 ENG HPC PER MM 36-11-08. RAN ENGINES PER JRH. NR 2 BLSDR 2008UALA01984Coffeemaker · faultyFA SHOCKED WHEN GRABBING BOTH HANDLES OF THE COFFEE POTS AT 2R. REPLACED M51 & M52 COFFEE MAKER - OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01983Battery · inoperativeSTATUS LIGHT ON FLASHLIGHT AT BUSINESS GALLEY NOT ON. REPLACED BATTERY OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01936Module · crackedAC ARRIVED CENTER HYD LOW, 68 PERCENT. FOUND FLAP SLAT HYD SHUTOFF MOD CRACKED AND LEAKING, RT WHEEL WELL. REPLACED HYDRAULIC SHUTOFF MODULE LEAK CHECKED OK. AC OK FOR SERVICE.SDR 2008UALA01911Shutoff Valve · leakingLEFT O/B FUEL VALVE LEAKING THROUGH MANUAL OPERATION KNOB. FOUND LEAKING FUEL SHUT OFF VALVE ALSO FOUND A FAULTY RELAY K180 FOR VALVE OPERATION.
REPLACED 1 EACH VALVE AND 1 EACH RELAY. AC OK FOR SERVICE.SDR 2008UALA01909Power Supply · defectiveEMERGENCY EXIT LIGHTS COME ON OCCL NEAR 2L. REPLACED POWER SUPPLY M737 & BATTERY FOR POWER SUPPLY UNIT M1559. OP CHKS OKAY.SDR 2008UALA01887Frame · corrodedAFT PIT AT BS 1197+88 AND LBL 40 FRAME T-CAP IS CORRODED UNDER AND AROUND NUT PLATE. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR 2008UALA01886Frame · corrodedAFT PIT AT BS 1197+132 AND LBL 40 FRAME T-CAP IS CORRODED UNDER AND AROUND NUT PLATE. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR 2008UALA01885Frame · corrodedAFT CARGO COMPT AT BS 1219 AND RBL 33, FRAME T-CAP IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR 2008UALA01884Frame · corrodedAFT CARGO COMPT AT BS 1197 + 66 AT LBL 14 FRAME T-CAP IS CORRODED UNDER AND AROUND NUT PLATES. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR 2008UALA01908Battery Pack · inoperativeEXTERNAL EMERGENCY LIGHT LT AFT OF OVERWING SLIDE INOP. RELAMPED AND REPLACED BATTERY PACK OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01907Battery Pack · dischargedEXTERNAL EMERGENCY LIGHT RT OVERWING INOP. REMOVED AND REPLACED BATTERY PACK OPS CHECKED GOOD. AC OK FOR SERVICE. REMOVED AND REPLACED BATTERY PACK AND OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01906Battery Pack · dischargedEXTERNAL EMERGENCY LIGHT RT OVERWING INOP. REMOVED AND REPLACED BATTERY PACK OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01905Battery Pack · dischargedEXTERNAL EMERGENCY LIGHT RT DOOR R4 INOP. REMOVED AND REPLACED BATTERY PACK OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01866Module · brokenLAV 124 OXYGEN MASK COMPARTMENT DOOR BROKEN OFF AND MASK FELL DOWN. REPLACED PASSENGER OXYGEN MODULE. AC OK FOR SERVICESDR 2008UALA01842Extinguisher · dislodgedREINSTALL COCKPIT FIRE EXTINGUISHER FELL OFF BRACKET. REINSTALLED BOTTLE IN HANGER ASSY. AC OK FOR SERVICESDR 2008UALA01841Light · intermittentEXIT ROW EMERGENCY LIGHTS GO ON AND OFF INTERMITTENTLY. COULD NOT DUPLICATE LIGHT MALFUNCTION. TEST OK NO FAULTS DETECTED. AC OK FOR SERVICE.
SDR 2008UALA01840Idg · malfunctionedR GEN DRIVE LIGHT ON CONTINUOUSLY. REPLACED NR 2 ENG IDG. OP CHECKED AND LEAK CHKD OK. A/C OK FOR RETURN TO SERVICE.SDR 2008UALA01823Shear Tie · corrodedAFT CARGO COMPARTMENT AT BS 1197+88 BETWEEN S-39L-39R SHEAR TIE IS CORRODED. MAJOR REPAIR ACCOMPLISHED, REMOVED AND REPLACED SHEAR TIE.SDR 2008UALA01822Shear Tie · corrodedAFT CARGO PIT, BS 1197+66 BETWEEN S-39L-39R, SHEAR TIE IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED SHEAR TIE.SDR 2008UALA01821Frame · damagedFRAME IS TORN OUT STA 1351 BETWEEN STR 28R-26R. REPAIRED FRAME IAW SRM 53-00-01 FIG 201 DETAIL II AND SRM 51-40-02. AC OK FOR SERVICE.SDR 2008UALA01820Stiffener · crackedBS 246 FLOORBEAM AT APPROX RBL 16 HAS A CRACKED VERTICAL STIFFENER. MAJOR REPAIR ACCOMPLISHED, REMOVED AND REPLACED STIFFENER.SDR 2008UALA01809Light · out of positionSEAT MOUNTED EMERGENCY LIGHT AT SEAT 41H RIPPED OFF. SUPPLEMENTAL DATA UPDATE, REPLACED LIGHT ASSY. CHECK OKAY.
SDR 2008UALA01784Idg · failedL GENERATOR DRIVE LIGHT ILLUMINATED. LOST LEFT GENERATOR. NR 1 ENGINE IDG DISCONNECTED DUE TO FAULTS. REPLACED IDG AND GEN CONTROL UNIT (PRECAUTIONARY). GENERATING SYSTEM OP CHKD OK FOR SERVICE.
SDR 2008UALA01760Gcu · faultedEICAS MSG L GEN OFF DISPLAYED. SUSPECT FAULTY BEARING IDG. REPLACED GENERATOR PER AMM24-11-01 AND GCU PRECAUTIONARY OPS CHECKED NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA01790Oxygen Mask · leakingF/O OXYGEN MASK LEAKS FROM THE HEADBAND.SDR 2008UALA01808Contact · damagedEXTERIOR EMERGENCY LIGHT AFT OF RT WING INOP. SUSPECT BAD CONTACT. CLEANED CONTACT OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01771Relay · faultyAPU SHUT DOWN JUST AFTER NR 2 ENGINE STARTED APU HAS NO POWER ON INITIAL TESTING. SUSPECT RELAY. REPLACED RELAY STARTS NORMALLY AND ACCEPTS POWER TRANSFERS. AC OK FOR SERVICE
SDR 2008UALA01770Light · smokeREAD LT AT 41B REPORTED TO HAVE HAD ELEC ODOR AND PUFF OF SMOKE COMING FROM IT, DISSIPATED AFTER A FEW MINUTES. UNABLE TO DUPLICATE PROBLEM. ALL GROUNDS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA01754Valve · poppedCB M4 "IDG VALVE" LEFT ENG POPPED.SDR 2008UALA01759Warning System · activatedAPU GEN OFF EICAS MSG WITH ASSOC SWITCH LIGHT ILLUMINATED.SDR 2008UALA01750Light · unsecureEMERGENCY LIGHT STRIP COMING UP AT RT SIDE OF BUS GALLEY AT ROWS 10E-F.
SDR 2008UALA01726Flap System · stuckFLAP HANDLE AT 5, FLAPS LOCKED UP AT 1 EICAS, T/E FLAP DISAGREE.