SDR 2008UALA00800Light · inoperativeEEL LIGHT NEAR FWD GALLEY, ADJACENT TO DOOR 1L INOP. REPLACED EMERGENCY LIGHT.SDR 2008UALA00783O-Ring · leakingLANDED UNDER AMBER ALERT DUE TO CENTER HYDRAULIC SYSTEM INDICATION. CONDUCTED TROUBLESHOOTING. FOUND NR 3 SPOILER ACTUATOR PLUG FOR FINGER FILTER O'RING BAD. REPLACE O'RING. OPERATES NORMALLY WITH NO LEAKS NOTED. SERVICED CENTER HYD SYSTEM FLUID TO FULL. SDR 2008UALA00744Bottle · reads lowDOOR SLIDE PRESSURE OUT OF LIMITS AT 2L. REPLACED DOOR 2L SLIDE ASSEMBLY . SUSPECT LEAKING PRESS BOTTLE. A/C OK FOR SERVICE.
SDR 2008UALA00782Connector · shortedLEFT BUSS TIE WILL NOT GO ON LINE. PERFORMED TROUBLESHOOTING. FOUND WIRE SHORT TO GRND FROM L-GENERATOR CONTROL UNIT B-CONNECTOR PIN C11, TO L-GEN DPCT-2. CONFIRMED CONNECTOR D5849P AT FAULT, REPLACED CONNECTOR D5848P, LT BUSS TIE OPERATED NORMALLY. SUSPSDR 2008UALA00781Battery Pack · inoperativeLEFT EMERGENCY LIGHTS L1 AND L3 OVERWING LIGHTS ARE INOP. REPLACED BATTERY PACK.
SDR 2008UALA00791Structure · dentedAFT MANUAL CARGO DOOR HAS DENT APPROX 3 INCHES FROM AFT EDGE AND THREE FEET FROM BOTTOM. REMOVED DAMAGED AREA. FABRICATED AND INSTALLED DOUBLER REPAIR. A/C OK FOR RETURN TO SERVICE.SDR 2008UALA00779Light · inoperativeIN SEAT EMERGENCY LIGHTS AT SEATS 3HJ, 24HJ AND 35HJ ARE INOP. REMOVED AND REPLACED LIGHTS.SDR 2008UALA00778Support · crackedBS 246 AT BL 0, PULLEY SUPPORT CRACKED.SDR 2008UALA00777Lamp · faultyEMERGENCY AISLE LIGHT ABOVE SEAT 12HJ IS DIM. REMOVED AND REPLACED LAMP.SDR 2008UALA00776Connector · looseL-1 DOOR EMERGENCY EXIT LIGHT IS INOP. RESEATED CONNECTOR.SDR 2008UALA00775Connector · unsecureEXTERIOR LIGHTS, OVERWING EMERGENCY SLIDE AND DOOR LIGHTS ARE INOP (LEFT SIDE). RESEATED CONNECTOR.SDR 2008UALA00774Cylinder · defectiveLEFT OVERWING SLIDE CABLE BALL IS BELOW RETAINER SPRING ON INFLATION CYLINDER.SDR 2008UALA00771Housing · crackedLEFT OVERWING EMERGENCY SLIDE DISCONNECT HOUSING IS CRACKED.SDR 2008UALA00770Lamp · inoperativeRIGHT AFT DOOR UPPER EMERGENCY EXIT LIGHT, DOOR HANDLE ILLUMINATION PORTION IS INOP. RELAMPED.SDR 2008UALA00715O-Ring · leakingSLIDE ASPIRATOR LEAKING. ASPIRATOR HAD BAD O-RING. REPLACED ASPIRATOR. SUSPECT O-RING PINCHED OR OVERLY COMPRESSED DURING INSTALLATION. SLIDE REPLACED AND A/C OK FOR SERVICE.SDR 2008UALA00714Aspirator · leakingSLIDE ASPIRATOR BARREL LEAKING. NO APPARENT DAMAGE TO ASPIRATOR. SUSPECT SEAL LEAKAGE. REPLACED ASPIRATOR & SLIDE ASSY. A/C OK FOR SERVICE.SDR 2008UALA00703Light · unsecureEMERGENCY EXIT LIGHT AT L-1 DOOR-UPPER SIGN IS NOT PROPERLY SECURED, CAUSES LENSE TO BE LOOSE.SDR 2008UALA00702Support Bracket · crackedBS 246, RBL 13.96 PULLEY SUPPORT BRACKET IS CRACKED.SDR 2008UALA00707Connector · looseLOST GALLEY POWER ON RIGHT SIDE ON CLIMB. REPLACED AFT GALLEY ELECTRICAL LOAD CONTROL UNIT M 226 AND RELAY K2 AT OVERHEAD PANEL, CHECKED K101,K102,K103 FOR SEC AND OVERHEAT. NO FAULTS NOTED. SEC AFT GALLEY MAIN FEEDER CONNECTOR 2 & HALF TURN 138164ACP. OPS CHSDR 2008UALA00694Battery Pack · inoperativeAFT ENTRY DOOR LEFT AND RIGHT EMERGENCY EXIT LIGHT IS INOP. INSTALLED NEW BATTERY.
SDR 2008UALA00693Support · crackedBS 246 AT RBL 15.78 PULLEY SUPPORT CRACKED.SDR 2008UALA00692Connector · looseFOUND EMERGENCY LIGHT AT SEAT 17HJ IS INOP. RESECURED LOOSE CONNECTION.SDR 2008UALA00691Light · inoperativeCENTER GALLEY RT EMERGENCY LIGHT (EEL) STRIP INOP. REPLACED EEL STRIP.SDR 2008UALA00690Light · inoperativeCENTER GALLEY LT EMERGENCY LIGHT STRIP INOP. REPLACED LT CENTER GALLEY EEL STRIP.SDR 2008UALA00656Fseu · faultySTATUS MSG FLAP-SLAT ELEC. AFTER EXTENSIVE TROUBLESHOOTING OF THE FSEU SYSTEM. REPLACED FLAP SLAT ELECTRONICS UNIT PER MM 27-51-01. TEST PASS. NO GRIPS OF FLAP SLATE ELECTRICAL SYSTEM TO DATE. AC OK FOR SERVICE.SDR 2008UALA00678Light · faultyWITH FLIGHT DECK EMERGENCY LIGHT SWITCH IN ARM, INTERIOR EMERGENCY EXIT LIGHTS TURN ON. AFTER FURTHER TROUBLESHOOTING FOUND EMERGENCY C/B TO BE COLLARED. RESET C/B`S AND CHECKED GOOD IAW MM 33-51-00.SDR 2008UALA00677Lens · crackedSEVERAL LOWER EMERGENCY EXIT LIGHT IDENTIFIER LENSES ARE CRACKED OR EXCESSIVELY DIRTY.SDR 2008UALA00676Connector · damagedEMERGENCY EEL LIGHT INOPERATIVE AT SEAT 5AB. SECURED CONNECTOR.SDR 2008UALA00668Stiffener · crackedBS 246 AT LBL 26.39 STIFFENER IS CRACKED.SDR 2008UALA00667Oxygen Bottle · low pressureCREW O2 NEEDS SERVICING. NOW AT 940 PSI.SDR 2008UALA00666Wire · misinstalledR GEN DRIVE EICAS AND DRIVE LIGHT ILLUMINATED. WIRE IMPROPERLY INSTALLED AND FAULTY IDG. REPAIRED WIRE HARNESS REPLACED FAULTY IDG OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA00659Aspirator · unserviceableASPIRATOR LEAKING.SDR 2008UALA00655Starter · failedNR 1 ENGINE STARTER FAILED. REPLACED STARTER AND STARTER START VALVE PER MM 80-11-01 & MM 80-11-02. ACP ENG RUN CHECKS OK. NO LEAKS FOUND. AC OK FOR SERVICE.SDR 2008UALA00641Monitor · malfunctionedELECTRICAL ODOR COMING FROM VIDEO MONITOR LOCATED AT SEAT 8J. UNIT THEN SHUT DOWN. THE UNIT WAS CONFIRMED TO BE INOPERABLE BY PACTECHNICIAN. AFTER INSPECTING ALL RELATED WIRING ASSOCIATED WITH THIS CIRCUIT, THE UNIT WAS REPLACED WITH A SERVICABLE UNIT AND OSDR 2008UALA00638Unknown · smokeCREW REPORTS VISIBLE SMOKE IN CABIN, MOST NOTICEABLE AT ROW 12. UNABLE TO DUPLICATE REPORTED PROBLEM. MECHANICS AND FLT CREW NOTED NO SMOKE IN CABIN ON RETURN FLIGHT FROM MCI TO ORD. NOTED FIND IN ATA CODE 210000.
ACFT OK FOR SERVICE.SDR 2008UALA00654Flap · crushedLEFT WING,OUTBOARD FLAP LEADING EDGE IS CRUSHED AND HAS 1 INCH LONG PUNCTURE LOCATED FROM APPROX 24 INCHES FROM OUTBOARD END TO APPROX 48 INCHES FROM OUTBOARD END.SDR 2008UALA00616Light · missingEEL STRIP AT SEAT 33A MISSING. REPLACED MISSING EEL LIGHT, OP CHECKS OK. RETURNED TO SERVICE.SDR 2008UALA00612Smoke Goggles · crackedCAPTAIN'S SMOKE GOGGLES BROKEN AND CRACKED. REPLACED GOGGLES. ACFT OK FOR SERVICE.SDR 2008UALA00615Battery Pack · dischargedFIVE EACH EXIT SIGN INOP L322, L297, L699, L700 AND L1050 WING HATCH EXIT SIGN. REPLACED BATTERY PACK. AT LOCATION M1209. OP CHECKS OK FOR SERVICE.SDR 2008UALA00614Actuator · faultyEICAS MSG SPOILERS DISPLAYED. SPOILERS LIGHT ILLUM WITH SPOILERS SELECTED UP. FAULTY POWER CONTROL ACTUATOR. REPLACED NR 9 PCA PER MM 27-61-02. OPS CHECK GOOD. ACFT OK FOR SERVICE.SDR 2008UALA00613Battery · inoperativeEMERGENCY EXIT SIGNS AT BOTH AFT ENTRY DOORS ARE INOP. REMOVED AND REPLACED BATTERY.SDR 2008UALA00581Light · inoperativeFWD RIGHT GALLEY EMERGENCY LIGHT STRIP (EEL) INOP. REMOVED AND REPLACED LIGHT STRIP.SDR 2008UALA00564Skin · damagedFUSELAGE SKIN APPROX STA 280 BETWEEN STR 2L & 3L HAS BLEND MARKS. MAJOR REPAIR ACCOMPLISHED: MFG'D AND INSTALLED REPAIR DOUBLER WITH BLIND FASTENERS.SDR 2008UALA00590Valve · leakingASPIRATOR LEAKING. FAULTY VALVE. REPLACED SLIDE AND ASPIRATOR. ACFT OK FOR SERVICE.SDR 2008UALA00585Hinge Fitting · crackedRIGHT I/B AFT FLAP CENTER HINGE FITTING CRACKED ON I/B AND O/B SIDES. ACCOMPLISHED INSPECTION OF THE OUTBOARD HINGE FITTINGS ON LEFT AND RIGHT WING INBOARD TRAILING EDGE MAIN FLAPS. MANDATED BY AD 2003-13-01 AND NOT EXTENDABLE. REMOVED, REPLACED AND INSTALLEDSDR 2008UALA00584Attach Angle · crackedFWD E&E COMPT AT STA 246 AT LBL 40 ATTACH ANGLE AFT SIDE OF FLOORBEAM IS CRACKED. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW ATTACH ANGLE.SDR 2008UALA00583Housing · brokenLEFT OVERWING SLIDE DOOR DISCONNECT HOUSING IS BROKEN AND NEEDS TO BE REPLACED.SDR 2008UALA00582Connector · disconnectedEXIT PATH LIGHT STRIP AT 1F DISCONNECTED. SECURED CONNECTOR.SDR 2008UALA00562Lens · crackedSEVERAL LOWER EMERGENCY EXIT IDENTIFIER LENSES ARE CRACKED OR EXCESSIVELY DIRTY.
SDR 2008UALA00561Latch · inadequateRT OVERWING SLIDE COMPARTMENT DOOR LATCHES NR 2 & 3 FAIL EDGE MARGIN MEASUREMENT. REMOVED AND REPLACED LATCHES. ACFT OK FOR SERVICE.