SDR 2007UALA04813Wire · out of positionFLIGHT REPORTS STRANGE WIRE STICKING OUT OF SEAT 40B.
SDR 2007UALA04817Smoke Detector · inoperativeNR 1 AFT CARGO COMPARTMENT SMOKE DETECTOR INOPERATIVE.
SDR 2007UALA04811Battery · dischargedRIGHT EXTERNAL EMERGENCY LIGHTS ARE INOPERATIVE.
SDR 2007UALA04816Light · out of positionSEAT 14H SIDE SEAT EEL LIGHT PULLED OUT AND ON SEAT.SDR 2007UALA04810Light · intermittentEMERGENCY PATH LIGHT STRIP AT ROW 28 LEFT SIDE FLICKERING ON & OFF.
SDR 2007UALA04812Slide · damagedRIGHT AFT SERVICE DOOR SLIDE FABRIC TORN ON TOP AND IS MISSING YEAR OVERHAULED STICKER BY.SDR 2007UALA04809Battery · dischargedEMERGENCY EXIT PATH LIGHTS ON FLOOR IN AFT PART ECONOMY ON LEFT SIDE ONLY ARE FLASHING ON AND OFF.
SDR 2007UALA04784Floorbeam · crackedON THE FORWARD FACE OF FLOORBEAM LOCATED AT BS 246 LBL 22L AT STIFFENER IS CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED STIFFENER.SDR 2007UALA04783Stiffener · crackedFLOORBEAM AT FS 246 FORWARD SIDE VERTICAL STIFFENER CRACKED AT LBL 26.39. REMOVED & REPLACED STIFFENER.SDR 2007UALA04740Connector · inoperativeFLOOR EEL LIGHTS INOPERATIVE AT 10E. FOUND TERMINAL CONNECTOR LOOSE, SECURED AND OPS CK NOW OK.
SDR 2007UALA04742Start Valve · faultyLEFT ENG START VALVE WON`T OPEN. REPLACED NBR 1 ENG STARTER PER AMM 80-11-01 AND REPLACED STARTER CONTROL VALVE PER AMM 80- 11-02. GRD OPERATION CHECKED GOOD. AIRCRAFT OK FOR SERVICE.SDR 2007UALA04741Bulb · inoperativeAT ROW 29AB LEFT OVERHEAD CEILING LIGHT EMERGENCY EXIT IS OUT. REPLACED LIGHT BULB. OPS CHECKS GOOD.
SDR 2007UALA04709Lens · missingRIGHT MID CABIN (STA 654) AISLE EXIT LENS IS MISSING. SUSPECT LENS LOST DURING NORMAL OPERATIONS. REPLACED LENS OPS CHECKED OK. ACFT OK FOR SERVICE.SDR 2007UALA04695Light · inoperativeFWD PARTITION LIGHT BAR INOP, EEL . REMOVED AND REPLACED LIGHT BAR.SDR 2007UALA04664Light · damagedEEL STRIP DAMAGED AT SEAT 5A. REPLACED EEL STRIP, TEST OK.
SDR 2007UALA04675Aspirator · unserviceableASPIRATOR LEAKING. REPLACED ASPIRATOR AND SLIDE. ACFT OK FOR SERVICE.SDR 2007UALA04663Power Supply · intermittentEEL LIGHTS FLICKER ON AND OFF AT LEFT SIDE OF FIRST CLASS. SUSPECT BAD PWR PACK. PREVIOUS HISTORY. REPLACED BATTERY POWER SUPPLY PACK. TEST FLOOR EEL LIGHTS. OP CHKS GOOD.
SDR 2007UALA04635Battery · faultyEMERGENCY LIGHTING ON LEFT SIDE OF ECONOMY FLASHES ON AND OFF DURING FLIGHT. REPLACED BATTERY SUPPLY AT 17A. OPS CHECKED OKAY.SDR 2007UALA04632Light · improper partAFT GALLEY (G4) SHORT LIGHT BAR IS WRONG TYPE. INSTALLED CORRECT PART, OPS CHECKS NORMAL.SDR 2007UALA04634Wire · arcedLEFT WING O/B SURGE TANK WIRES HAS SIGNS OF ARCING AT TERMINAL BLOCK, HARDWARE RUSTED O/B SIDE OF RIB 31. REPLACED LEVEL SENSOR AND TERMINAL BLOCK. AC OK FOR SERVICESDR UALA2008111304633Structure · crackedNR 2 PYLON FUEL LINE CUTOUT FWD INBOARD ATTACH HOLE CRACKED. SUSPECT ENGINE VIBRATION CAUSE. INSTALLED NEW REPAIR DOUBLER PER REO-G12178 REV B. AC OK FOR SERVICE.SDR 2007UALA04630Light · inoperativeLEFT MID LAV EEL LIGHT BAR IS INOPERATIVE. REPLACED LIGHT BAR.
SDR 2007UALA04653Drive Assy · failedREPORTS OF SPARKS COMING FROM NR 1 ENGINE ON START. NR 1 ENGINE DAMAGED EXTENSIVELY FROM STARTER DISINTEGRATION. REPLACED STARTER. STARTER DRIVE SPLINE IN GEARBOX SHEARED. REPLACED NR 1 ENGINE. ACFT OK FOR SERVICE.SDR 2007UALA04633Structure · crackedNR 2 PYLON FUEL LINE CUTOUT FWD INBOARD ATTACH HOLE CRACKED.SDR 2007UALA04654Actuator · faultyAIRCRAFT REQUIRES 4 UNITS LEFT RUDDER TRIM DURING CRUISE. L & R FUEL TANKS BALANCED. SUSPECT RUDDER TRIM ACTUATOR. REPLACED RUDDER TRIM ACTUATOR. ALL SYSTEMS CHECK NORMAL. PERFORM SINGLE HYDRAULIC SYSTEM CHECK OF EACH RUDDER POWER CONTROL ACTUATOR USING EASDR 2007UALA04619Floorbeam · crackedMAIN CABIN FLOORBEAM, ATTACH VERTICAL CHANNEL CRACKED AT BS 1503 LBL 67. MAJOR REPAIR ACCOMPLISHED. REMOVED & REPLACED CHANNEL LBL 67.SDR 2007UALA04618Floorbeam · crackedSTA 246, LBL 26, FLOORBEAM VERTICAL STIFFENER IS CRACKED. REMOVED & REPLACED VERTICAL STIFFENER.SDR 2007UALA04609Engine · flamed outNR 1 ENGINE FLAMEOUT IN FLIGHT.SDR 2007UALA04607Light · missingEEL STRIP AT 26HJ MISSING. REPLACED LIGHT STRIP.SDR 2007UALA04597Target · contaminatedAT FL360, THE FLAP INDICATOR IS FLICKERING BETWEEN UP AND 1 DEG' WITH ASSOCIATED `LE SLAT ASYM' MSG. CREW ALSO NOTED A CLICKING OR CHATTERING TYPE NOISE IN THE OVERHEAD PANEL AREA BY THE 'RAT' SW AREA THAT FELT QUITE WARM. FOUND SLAT INDICATION TARGETS FULLSDR 2007UALA04596Pump · leakingCTR ADP HAS HYDRAULIC LEAK. REPLACED AIR DRIVEN PUMP PER MM29-11-03. DURING OPS CHECK OF ADP FOUND PRESSURE REGULATOR VALVE FAILED. OPS CHECK NORMAL. ACFT OK FOR SERVICE.
SDR 2007UALA04591Light · inoperativeSEATS 2B AND 3B BOTH HAVE ONE SEAT MOUNTED EMERGENCY EXIT LIGHT INOP, THE SECONDARY LIGHT ON BOTH SEATS DO OPERATE SATISFACTORILY. REPLACED EEL STRIPS AT SEATS 1B & 2B.SDR 2007UALA04590Light · brokenSEAT 21H, EEL LIGHT BROKE OFF SIDE OF SEAT. REPLACED LIGHT ASSY, LIGHT CKS OK.SDR 2007UALA04565Indicator · faultyRTFL DUE TO STANDBY ATTITUDE INDICATOR PROBLEMS. REPLACED STANDBY ATTITUDE INDICATOR WITH BORROWED UNIT. OPERATIONAL TEST CARRIED OUT SUCCESSFULLY. ACFT CATII-III STATUS NOT ALTERED.
SDR 2007UALA04561Pump · unknownRTFL DUE TO CENTER HYDRAULIC PUMP PROBLEM. REPLACED HYDRAULIC AIR DRIVEN PUMP. ALSO REPLACED HYD LINES & PUMP MOUNTS. PERFORMED SYSTEM CHKS. OK FOR SERVICE.
SDR 2007UALA04560Oxygen Bottle · leakingBOTH OXYGEN BOTTLES IN AFT CABIN RIGHT SIDE SHOW BELOW THE GREEN ARC. SUSPECT LEAK AT FILLER VALVE. REPLACED BOTTLES. ACFT OK FOR SERVICE.
SDR 2007UALA04572Engine · leaking(NR 1 ENG HOC): OIL LEAKING FROM FUEL PUMP DRAIN 4 DPM WITH ENG STATIC.SDR 2007UALA04564Charger · faultyAPU BATTERY DOES NOT CHARGE. SUSPECT FAULTY BATTERY CHARGER. REPLACED APU BATTERY AND CHARGER OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR 2007UALA04563Connector · looseBUSINESS CLASS FLOOR LIGHTING INOP ON LEFT SIDE. SECURED CONNECTOR.
SDR 2007UALA04562Battery · faultyFOUND ROWS 15-18 LEFT SIDE OF ACFT EMERGENCY EXIT LIGHTS KEEP COMING ON. REPLACED BATTERY AND FOUND CONNECTOR LOOSE, SYSTEM CHECKED NORMAL.
SDR 2007UALA04511Panel · damagedFOUND ON ARRIVAL 5 BY 7 INCH SECTION OF PANEL 551VB MISSING LOWER LEFT WING JUST INBOARD OF LEFT MLG. SUSPECT FATIGUE FROM NORMAL AC OPERATION. FABRICATED ALUMINUM DOUBLER .040 THICK AND INSTALLED. NEED NEW 551VB PANEL MF1544 CREATED TO MONITOR UNTIL PANELSDR 2007UALA04510Connector · looseEND CAPS MISSING FROM FRONT OF ESCAPE PATH LIGHTING STRIPS IN FIRST CLASS. ALSO CONNECTIONS LOOSE IN SAME AREA. RECONNECTED, OPS CHECK AND INSTALLED END CAPS.
SDR 2007UALA04499Hose · collapsedHOSE ASSY FOR RAMP SLIDE INFLATION HAS COLLAPSED. SUSPECT HOSE DAMAGED DURING MAINTENANCE. REPLACED HOSE ASSEMBLY. ACFT OK FOR SERVICE.SDR 2007UALA04498Bulb · inoperativeEMERGENCY FLASHLIGHT AT MID GALLEY CLOSET INOP. SUSPECT FAULTY BULB OR BATTERIES. REPLACED FLASHLIGHT, NOW OPS OK. ACFT OK FOR SERVICE.SDR 2007UALA04465Stringer · corrodedMAIN CABIN, RT FUSELAGE INTERNAL, STR 13R HAS SURFACE CORROSION JUST AFT OF STA 1263. SUSPECT MOISTURE CONTAMINATION. REMOVED DAMAGED AND FABRICATED REPAIR AND INSTALLED PER SRM 53-00-03. ACFT OK FOR SERVICE.SDR 2007UALA04464Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED AT OUTBOARD END BS 287 AT FWD LOWER CORNER OF R-1 DOOR CUTOUT. SUSPECT MOISTURE CONTAMINATION. REMOVED DAMAGED SECTION OF CAP AND FABRICATED CAP SECTION, ANGLES AND STRAPS AND INSTALLED PER SRM 53-00-51. ACFT OK FOR SERVICE.SDR 2007UALA04463Frame · corrodedMAIN CABIN FRAME CAP CORRODED STA 246 BL80R TO BL84R. SUSPECT MOISTURE CONTAMINATION. REMOVED CAP SECTION AND FABRICATED NEW SECTION. ACFT OK FOR SERVICE.SDR 2007UALA04443Cap · missingEEL STRIP END CAPS MISSING IN FC AND BC ZONES, 5 EA. REPLACED MISSING EEL STRIP END CAPS.SDR 2007UALA04442Connector · unsecureEMERGENCY FLOOR LIGHTING ON LEFT SIDE OF CABIN AFT OF ROW 15 COMES ON INTERMITTENTLY. SECURED, RESET CONNECTIONS ON EEL STRIP LEFT SIDE OF CABIN. OPS CHECK OK.SDR 2007UALA04444Engine · vibrationENG 2 VIBRATIONS SHIFTED UP FROM 0.2 TO 0.8 UNITS.