Boeing 767-332
Service difficulty reports · 11,959
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA14005650126Connector · disconnectedCABIN EMERGENCY EXIT LIGHTS ARE INOPERATIVE AT LT MID LAVATORY. MAINTENANCE CONNECTED LIGHTS. SYSTEM OPERATION IS NORMAL.SDR HALA2014012500014Transceiver · failedNR 1 & 2 HF RADIO RECEIVERS INOPERATIVE IN AIR, ON GROUND VHF TEST OK, IN AIR IS UNRELIABLE, SELCAL CHECKED OK. REPLACED BOTH LT AND RT HF TRANSCEIVERS. GROUND CHECKED OK IAW 23-11-00.SDR HALA2014012100009Adc · unknownF/O ALTIMETER IS NEAR RVSM LIMITS. R & R RT ADC IAW AMM 34-12-01-404-006. PERFORMED FUNCTIONAL TEST IAW AMM SUB TASK 34-12-01-744-016, CHECKED OK. LEAK CHECKED GOOD IAW AMM 34-11-00, CAPTAIN`S AND FIRST OFFICER`S ALTIMETER WITHIN LIMITS IAW FIM TASK 34-13. SDR DALA14004250130Charger · inoperativeEMERGENCY ESCAPE PATH LIGHTS FIRST 6 ROW ON RT SIDE ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY CHARGER. SYSTEM OPS ARE NORMAL.SDR DALA14004260199Skin · gougedAFT CARGO BAY AFT SIDE OF DOOR, 18 INCHES BELOW TOP CORNER, 10 INCHES AFT OF AFT SIDE OF DOOR, GOUGED. REMOVED DAMAGE IAW SRM 53-00-01.SDR HALA2014011000004Actuator · failedAPU VERIFICATION FAILED JUST PRIOR TO TOP OF DESCENT, FLT 370 -60 SAT, ATTEMPTED TWO STARTS, NO RPM, NO EGT. FOUND APU INTAKE DOOR ACTUATOR INOPERATIVE. APU INTAKE DOOR FULLY OPEN. R & R APU AIR INTAKE DOOR ACTUATOR IAW AMM 49-15-06. OPS CKS NORMAL. CLEARED SDR HALA2014011000002Grommet · cutLEFT ENGINE AFT THROTTLE CABLE CUTTING INTO PHENOLIC GROMMENT FAIRLEAD INBD OF PYLON. R & R AFT THROTTLE CABLE PHONOLIC GROMMET. OK FOR SERVICE.SDR HALA2014010700001Altimeter · failedF/O ALTIMETER FAILED DURING DESCENT. REPLACED ALTIMETER IAW AMM 34-13-01. OPS CHECKED IAW 34-12-00 GOOD.SDR DALA14001320171Seat Track · corrodedMAIN DECK SEAT TRACK, RBL 11 BS 1410-1412 CORRODED. CORROSION REMOVED AND FOUND OUT OF LIMITS IAW SRM 53-00-52. REPLACED SEAT TRACK IAW ERA 521668-14.SDR DALA14001310171Seat Track · corrodedMAIN DECK SEAT TRACK LBL 11, BS 1410-1412 CORRODED. CORROSION REMOVED AND FOUND OUT OF LIMITS. REPLACED SEAT TRACK.SDR DALA14001300171Seat Track · corrodedMAIN DECK SEAT TRACK, RBL 11, BS 1109 CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS SRM 53-00-52. SEAT TRACK REPLACED IAW ERA 521668-14.SDR DALA14001290171Seat Track · corrodedMAIN DECK SEAT TRACK, RBL 11, BS 1250 CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-52. SEAT TRACK REPLACED IAW ERA 521668-14.SDR DALA14001280171Seat Track · corrodedMAIN DECK SEAT TRACK LBL 88.5, BS 1090 CORRODED. SEAT TRACK REMOVED AND REPLACED IAW SRM 53-00-52.SDR DALA14000401605Charger · inoperativeEMERGENCY LIGHTS FROM 6A TO 20A INOPERATIVE. R & R BATTERY CHARGER AND BATTERY PACK. OPS CHECKED GOOD IAW 33-51 AMM.SDR HALA2013122900183Acm · frozenLEFT PACK OFF LIGHT REMAINS ILLUMINATED WITH PACK SELECTED IN AUTO. ACCOMPLISHED FIM 21-51; FOUND LEFT ACM STUCK AND FROZEN. REPLACED ACM IAW AMM 21-51-03. DURING OPS CHECK OF ACM, CONTROL VALVE WAS INTERMITTENT. DURING ACM OPS CHECK FOUND LEFT FLOW CONTROSDR HALA201312250181Connector · failedFUEL QTY INDICATION STATUS MESSAGE CENTER TANK FUEL & TOTALIZER ON OVERHEAD ARE BLANK. R & R FQIS PROCESSOR IAW AMM 28-41-08 CONDITION SAME. FQIS BITE FAULT CODE 71. ACCOMPLISHED LT AUX TANK INSULATION RESISTANCE TEST AMM 28-41-00. FOUND LT AUX BUSSING PLUGSDR DALA13071690138Bulb · brokenLT SIDE OF FUSELAGE, TWO EMERGENCY EXIT EXTERIOR LIGHTS ARE INOPERATIVE. MAINTENANCE FOUND BROKEN BULB AND DAMAGED HARDWARE AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA13071650182Liner · puncturedTWO SMALL PUNCTURES ON NR 1 ENGINE INNER LINER AT 10 O`CLOCK POSITION, REPAIRED IAW SRM 54-00-01.SDR DALA13071680171Floorbeam · crackedCRACK FOUND ON FLOORBEAM UPPER TEE AT BS 347, LBL 10.0. REPAIRED IAW SRM 53-00-51.SDR DALA13071670171Angle · damagedMAIN DECK CABIN SECTION 46, CLIP NUT ATTACHMENT HOLE AT BS 1480 LBL 38, UPPER ANGLE. REPAIR CARRIED OUT IAW SRM 53-00-51.SDR DALA13071450130Battery Pack · inoperativeEXIT LIGHT ABOVE 1L DOOR AND 1R DOOR HANDLES NOT OPERATING DURING EMERGENCY LIGHT TEST. REPLACED BATTERY PACK IN CHARGER M1208.SDR DALA13071390182Tire · failedLOUD BANG AND VIBRATION AT ROTATION C AND RT HYD FAIL GEAR DID NOT RETRACT NR 8 MAIN TIRE EXPLODED ON ROLLOUT, DAMAGING STRUCTURE AND SEVERING HYDRAULIC LINES.SDR DALA13071380182Beam · damagedRIGHT WING SPOILER BEAM SURROUND STRUCTURE DAMAGED AFTER NR 8 TIRE. REPLACED UPPER AND LOWER RT WING SPOILER BEAM SURROUND STRUCTURE.SDR DALA13071370182Cylinder · separatedRIGHT WING TRANSFER CYLINDER SEPARATED. INSTALLED TRANSFER CYLINDER.SDR DALA13070271702Unknown · odorF/A REPORTED FUMES AND ODOR OF BURNING FOOD THROUGHOUT CABIN BUT HEAVIER IN MID CABIN AREA. CREW UNABLE TO ISOLATE, RETURNED TO DEPARTURE. PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56 AND TASK 21-00-21. INSPECTED BOTH LT & RT. SDR DALA13070111201Light · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEAT SIDES 17-31, RT SIDE. MAINTENANCE REPLACED THE M9009 CARRIER. SYS OPS IS NORMAL.SDR DALA13069991708Battery Pack · inoperativeEMERGENCY ESCAPE SLIDE SQUIBS WILL NOT TEST. REPLACED LT SIDE OVERWING ESCAPE BATTERY AND CHARGER IAW AMM 25-65, TESTED GOOD.SDR DALA13070140187Charger · inoperativeEMERGENCY LIGHT AT ROWS 38-41 ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY CHARGER M9010 AND FOUND BAD FUSE. SYS OPS IS NORMAL.SDR DALA13070130189Computer · failedAFTER APPROXIMATELY 4 HRS OF FLIGHT, WITH ACFT LEVEL AT 370, SMELLED ELECTRICAL ODOR. SHORTLY AFTER, NOTED NO LAND 3 ON AUTO LAND STATUS, ODOR DECREASED CONTINUOSLY TO ZERO BY END OF FLIGHT. PERFORMED TROUBLESHOOTING IAW FIM 22-02, FAULT TREE 808 , PERFORMEDSDR DALA13068461612Squib · no testON PDC, FOUND OVERWING LT AND RT EMERGENCY ESCAPE SQUIBS WILL NOT TEST. TROUBLESHOT IAW SSM 25-65-01. REPLACED M962 RT OVERWING POWER SUPPLY TEST. OK IAW AMM 25-65-17.SDR DALA13067350181Skin · damagedFUSELAGE SKIN BS 654+88 TO 654+110, S39R, FWD ATG 4 ANTENNA DAMAGED. COMPLIED WITH ERA 521275-14.SDR DALA13067340181Skin · damagedFUSELAGE SKIN BS 654+88 TO 654+110, S-39R, FWD ATG 4 ANTENNA DAMAGED. COMPLIED WITH ERA 521275-14.SDR DALA13068361402Light · inoperativeEMERGENCY ESCAPE PATH LIGHT AT MID LAV AREA UNDER F/A SEAT INOPERATIVE. MAINTENANCE REPLACED EMERGENCY EXIT LIGHT ASSY. CHECKED NORMAL.SDR DALA13067330175Structure · corrodedRIGHT MLG WHEEL WELL FWD BS 955 CORRODED. REPAIR CARRIED OUT IAW ERA 19789-14AD.SDR DALA13067320175Failsafe · crackedBS 955, RT FAILSAFE STRAP CRACKED, REPAIR CARRIED OUT WITH ERA 519778-14.SDR DALA13068370182Tire · failedFLIGHT RETURNED TO DEPARTURE DUE TO A BLOWN TIRE ON TAKEOFF. AFTER ROTATION CREW HEARD LOUD BANG IN BACK OF THE ACFT FOLLOWED BY HEAVY VIBRATION. AT APPROX 1000 FEET, RECEIVED THE RT AND CENTER HYDRAULIC PRESSURE FAILURE INDICATION. COMPLETED QRH PROCEDURESSDR DALA13067420136Wire · brokenROW 4AB AFT EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AT CONNECTOR. OPS NORMAL.SDR DALA13067410136Wire · brokenROW 35GF EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE. OPS CHECKED NORMAL.SDR DALA13067380181Skin · nickedSMALL NICK IN FUSELAGE SKIN AT BS 1197, STRINGER 39R. BLENDED NICK AND RESTORED FINISH, OK FOR SERVICE IAW SRM 53-00-01.SDR DALA13065651401Battery Pack · inoperativeFOUND THREE EMERGENCY LIGHTS AT C2 AND 4R DOOR WOULD NOT SHUTOFF. MAINTENANCE REPLACED LIGHT BATTERY POWER SUPPLY M733. SYSTEM OPS ARE NORMAL.SDR DALA13065261705Bottle · malfunctionedFOUND RT OVERWING SLIDE BOTTLE NOT INDICATING ARMED. R & R RT OVERWING SLIDE BOTTLE.SDR DALA13064390179Battery Pack · inoperativeFLT DECK EMERGENCY LIGHT EXIT SIGN OVER DOOR IS INOPERATIVE. MAINTENANCE REPLACED EXIT SIGN LIGHT ASSY AND BATTERIES. SYSTEM OPS NORMAL.SDR DALA13064380137Wire Harness · pinchedF/A REPORTED AFTER LANDING "SPARKS" CAME OUT OF FWD BULKHEAD AT SEATS 1E, F AND THEN THE IFES FOR E & F ROWS WENT BLANK. MAINTENACE INSPECTED MONITORS & SEAT BOX AT 1E&F. NO DAMAGE NOTED. NO ODOR OF FIRE AROUND 1E&F. FOUND POWER HARNESS PINCHED UNDER SEAT 1SDR DALA13064350181Fitting · misinstalledLEFT WING, UNDERWING LONGERON FITTING HOLES SHORT EDGE MARGIN. REPAIRED IAW ERA 520536-14AD.SDR DALA13064340181Floorbeam · crackedBS 1502, LBL 28.85, FLOORBEAM WEB CRACKED. REPAIRED IAW ERA520028-14.SDR DALA13062600181Floorbeam · crackedBS 1502 LBL 28 FLOORBEAM WEB FOUND CRACKED. REPAIRED IAW ERA 520028-14.SDR DALA13062620128Connector · unsecureEMERGENCY LIGHTS AT 11AB & 13AB ARE INOPERATIVE. MAINTENANCE FOUND CONNECTORS DISCONNECTED AT SEATS 11AB & 13AB. SECURED CONNECTORS.SDR DALA13062610181Skin · puncturedRT WING I/B AFT FLAP LOWER SURFACE FOUND PUNCTURED. METAL HOT BOND REPAIR CARRIED OUT IAW SRM 57-53-01.SDR DALA13062590181Skin · dentedBS 698 S39L TWO DENTS IN SKIN. REPAIRED IAW ERA 520024-14.SDR DALA13062020181Seat Track · corrodedMAIN DECK BS 733 TO 1098 SEAT TRACK CROWN & LIP CORRODED. REPAIRED PER SRM 53-00-52.
Back to Boeing 767-332