Boeing 767-332
Service difficulty reports · 11,959
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13020560199Skin · damagedDAMAGE TO FUSELAGE AFT UNDER BELLY NEAR TAIL ACCESS DOOR. CUTOUT DAMAGE IAW SRM 53-00-01. PERFORMED HFEC IAW SRM 53-00-01, STEP 4, NO FINDINGS. PERFORMED PERMANENT REPAIR IAW SRM.SDR DALA13020550192Light · inoperativeEXIT SIGNS AT BS 899 INOPERATIVE. REPAIRED IAW VA 85505MA.SDR DALA13019991706Connector · dirtySEAT 18FG, EMERGENCY LIGHT INOPERATIVE. CLEANED AND SECURED ELECTRICAL CONNECTOR. OPS CHECKED AND NORMAL.SDR DALA13020001706Connector · dirtySEAT 25AB, EMERGENCY LIGHT INOPERATIVE. CLEANED AND SECURED ELECTRICAL CONNECTOR. OPS CHECKED NORMAL.SDR DALA1312550130Slide · unknownOVERWING SLIDES DISARMED. REARMED SLIDES. SYSTEM CHECKS NORMAL.SDR DALA13020140178Charger · inoperativeDURING DRC FOUND EMERGENCY LIGHTS ROW AB 14-20 AND OVERWING EXIT SIGNS INOPERATIVE. MX REPLACED THE BATTERY CHARGER M9011 IAW AMM 33-51. SYS OPS IS NORMAL.SDR DALA13020130128Connector · disconnectedROW 33 G, F AISLE EMERGENCY LIGHT IS INOPERATIVE. CONNECTED SEAT CONNECTOR. SYS OPS IS NORMAL.SDR HALA2013042700046J-Box · failedRT PRIMARY ENGINE EGT INDICATOR READS ZERO USING LDRR ICAS COMPUTER STANDBY ENGINE INSTRUMENT ALSO READS ZERO. TROUBLESHOT IAW FIM 77-21, FAULT TREE 803 INSPECTED EGT THERMOCOUPLE CABLES TERMINALS AND BRACKET FOR DAMAGE INSPECTED CONNECTORS AND PINS AT FIREWASDR DALA13025550193Skin · damagedFOUND TWENTY LIGHTNING STRIKE DAMAGE POINTS BETWEEN BS 287 AND 654+110, S34-36L. REMOVED DAMAGE IAW SRM 53-00-01, REPAIR B SECTION C/W BHEC INSPECTION OF HOLES IAW SRM 53-00-01, FIG 201, NO CRACKS FOUND.SDR DALA13020490127Floor Support · corrodedCABIN FLOOR SUPPORT AT BS 325, RBL 50 FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02, REV 91.02. FOUND OUT OF LIMIT IAW SRM 53-00-51, FIG 101, REV 91.02. FLOOR SUPPORT TEE DAMAGED AREA CARRIED OUT REPAIR IAW SRM 53- 00-51, FIR 201, REPAIR 1.SDR DALA13019141702Web · damagedFOUND WEB WITH PLUG HOLES. REPAIRED IAW PRI 512837-14, REV ORIGINAL, REV 1, 2, 3, AND 4.SDR DALA13019131702Web · damagedBS 1518, LBL 27, FOUND WEB WITH PLUG HOLES. REPAIRED IAW PRI 512839-14, REV 0, 1, 2, 3 AND 4.SDR DALA13019121702Web · damagedBS 1480, RBL 27.25, FOUND WEB WITH PLUG HOLES. REPAIRED IAW PRI 512837, REV O ORIGINAL, REV 1, 2, 3, AND 4.SDR DALA13019111702Web · damagedBS 1480, RBL 24, FOUND WEB WITH PLUG HOLES. REPAIRED IAW PRI 512837-14, REV ORIGINAL, REV 1, 2, 3, AND 4.SDR DALA13019071702Web · damagedBS 1502, LBL 23, FOUND WEB WITH PLUG HOLES REPAIRED IAW PRI 513438-14, REV 0 AND REV 1. COMPARED AND COMPLIED WITH ER/A 513438-14, REV ORIGINAL.SDR DALA13019061702Web · canningFOUND WEB OIL CANNING. ACCOMPLISED IAW PRI 512839-14, REV ORIGINAL, REV 1, 2, 3, AND 4. COMPARE AND COMPLIED WITH ER/A 512839-14 REV ORIGINAL.SDR DALA13019151702Web · damagedFOUND WEB WITH PLUG HOLES. ACCOMPLISHED IAW PRI 512837-14, REV ORIGINAL, REV 1, 2, 3, AND 4. COMPARED AND COMPLIED ER/A 512837-14 REV, ORIGINAL.SDR DALA1310930130Power Supply · inoperativeFOUND ONE EXIT EMERGENCY LIGHT INOPERATIVE. R & R POWER SUPPLY AND BATTERY, OPS CHECKED OK IAW AMM 33-.SDR DALA13018630125Connector · damagedEMERGENCY PATH LIGHTS AT ROW 41GF ARE INOPERATIVE. MX SECURED PATH LIGHT PLUG SYS OPERATION IS NORMAL.SDR DALA13018610139Connector · damagedSEAT EMERGENCY PATH LIGHTS FROM ROW 34-46AB ARE INOPERATIVE. MX RESET PIN 9 ON CONNECTOR D9048. SYS OPS IS NORMAL.SDR DALA13018031708Battery Pack · inoperativeOVERWING SLIDE/SPOILER SQUIB TEST INOPERATIVE. REPLACED BATTERY IN LT POWER SUPPLY. OPS NORMALSDR DALA13018620139Power Supply · inoperativeIN SEAT EMERGENCY PATH LIGHTING ROW 34AB-46 ARE INOPERATIVE. MX REPLACED THE POWER SUPPLY. SYS OPS IS NORMAL.SDR DALA1310631401Fitting · crackedCRACK INDICATION ON LT WING AFT PITCH LOAD FITTING OTBD TENSION BOLT HOLE COMMON TO THE WING LOWER SKIN JOB ACCOMPLISHED IAW PRI 5128354-14AD REV O AND ER/A 512834-14AD REV ORIGINAL.SDR DALA1310561401Fitting · crackedOPEN HOLE HFEC INSPECTION FOUND CRACK AT AFT O/B FASTENER HOLE ON RT WING UPPER LINK PITCH LOAD FITTING. CRACK REPAIRED PER ERA 512832-14 REV ORIGINAL.SDR DALA1310541401Stringer · corrodedAFT CARGO STRINGER AT BS 1300 S35L FOUND CORRODED. STRINGER REPAIRED IAW ERA 512829-14 REV ORIGINAL.SDR DALA1310451401Skin · corrodedFUSELAGE SKIN AT BS 1540-1562 S27-29L. REPAIRED IAW ERA 513442-14, REV ORIGINAL.SDR DALA1310431401Frame · corrodedFRAME BS 368 BETWEEN S19 & 20R CORRODED. FRAME REPAIRED IAW ERA 512836-14, REV ORIGINAL.SDR DALA13018091610Light · inoperativeEMERGENCY LIGHT ROW 19A/B INOPERATIVE. HAVE 6 VOLTS TO CEILING PANEL PLUG. ONLY 3 VOLTS AT LIGHT ASSY.SDR DALA1310581401Angle · crackedRT WING L/E CAVITY AT APRROX 685 FRONT SPAR LT ANGLE FOUND CRACKED. NEW ANGLE FABRICATED AND INSTALLED IAW ERA 513480-14, REV ORIGINAL.SDR DALA1310501401Stringer · corrodedAFT CARGO BS 1315, S39L, STRINGER FOUND CRACKED THROUGH FROM CORROSION. STRINGER & STRINGER SPLICE REPAIRED IAW ERA.SDR DALA13017841613Power Supply · inoperativeEXTERIOR EMERGENCY LIGHTS WILL NOT ILLUMINATE. R & R EMERGENCY LIGHT POWER SUPPLY PACK (M733) IAW AMM 33-51 LT SIDE CHECKEDS GOODSDR DALA1310491401Frame · corrodedFUSELAGE FRAME FOUND CORROSION AT STA 1562, S39L AREA. FRAME REPAIRED IAW ERA.SDR DALA1310471401Failsafe · crackedFOUND CRACK ON RT SIDE BS 955 FAIL SAFE STRAP DURING HFEC OPEN HOLE INSPECTION. REPAIRED IAW ERA 512807-14.SDR DALA1310441401Failsafe · crackedDURING HFEC FOUND CRACK AT BS 955 FAILSAFE STRAP. REPAIR CARRIED OUT IAW ERA 512806-14AD.SDR DALA1309961401Frame · crackedCRACK FOUND ON LT SIDE BS 903.5 FRAME INNER CHORD DURING HFEC INSPECTION. REPAIR TO FRAME CARRIED OUT IAW WC 5311-01195-09-03A.SDR DALA1309951401Frame · crackedCRACK FOUND ON RT BS 883.5 FRAME INNER CHORD. REPAIR TO FRAME ACCOMPLISHED IAW WC 5311-01195-09-02B.SDR DALA1309941401Longeron Fitting · crackedDURING HFEC INSPECTION FOUND CRACK AT RT BS 783 LONGERON FITTING. RT LONGERON FITTING REPLACED AND ACCOMPLISHED EAJIC WC EA 01-499898-03, ME04, OPN 0401.SDR DALA1309931401Frame · crackedCRACK FOUND ON RT SIDE BS 903.5 FRAME INNER CHORD. DURING HFEC INSPECTION. REPAIRED FRAME IAW CARD 5311-01195-09-03B.SDR DALA1309870139Wire · looseDURING SERVICE CHECK, FOUND EMERGENCY LIGHTS INOPERATIVE FROM ROW 34AB. MX FOUND LOOSE CONNECTOR AT SEAT 33AB. SECURED WIRE AND CONNECTOR, SYS OPS IS NORMAL.SDR DALA1309660195Skin · damagedFUSELAGE SKIN BS 1425, S33-35L DENTED AND GOUGED. REPAIR CARRIED OUT IAW PRI 512813-14, REV O, FINAL ER/A 512813-14, REV O.SDR DALA1309750195Support · damagedSUPPORT HAS A OVERSIZED HOLE. REPAIRED IAW ERA 512835-14, REV ORIGINAL.SDR HALA2013041100037Actuator · inoperativeLT FUEL SPAR VALVE LIGHT REMAINED ILLUMINATED AFTER ENG SHUTDOWN. R & R LT ENGINE FUEL SHUTOFF VALVE ACTUATOR IAW AMM 28-22-11. OPS CHECKED NORMAL.SDR DALA1309921401Frame · corrodedCABIN FRAME BS 1131, BL 0 FOUND CORRODED. FRAME REPAIRED IAW SRM 53-00-07, FIG 201, REPAIR 1, REV 91.02.SDR DALA1308641401Seat Track · corrodedCABIN SEAT TRACK AT FS 347, RBL 55 - CORRODED. REPLACED SEAT TRACK IAW SRM 51-40-02, REV 91-02. (REJECTED DOES NOT MEET SDR REQUIRMENTS) NRC 220-058SDR DALA1308631401Floorbeam · corrodedCABIN FLOORBEAM AT FS 347, RBL 41-52 FOUND CORRODED. FLOORBEAM UPPER CHORD REPAIRED IAW SRM 53-00-51, FIGURE 201, REPAIR 1. REV 91-02.SDR DALA1308611401Frame · corrodedBS 412 FRAME BETWEEN S15 & 16R FOUND CORRODED OUT OF LIMITS. REPAIRED IAW SRM 53-00-07, FIG 201 REPAIR 1 REV 91-02.SDR DALA1308561609Frame · crackedMAIN DECK STA 903 WL200 RT FRAME INNER CHORD TRANSITION RADIUS CRACKED AT RADIUS APPROX .2500"LONG. REPAIRED IAW ERA 511795-14AD REV O.SDR DALA1308511703Power Supply · inoperativeEMERGENCY SEAT LIGHTS INOPERATIVE. REPLACED POWER SUPPLY M9009 AND BATTERY PACK IAW AMM 33-51.SDR HALA2013040700034Pressure Switch · failedAIR TURN BACK, RT OIL FILTER ANNUNCIATOR CAME ON IN CLIMB. FOLLOWED SHUTDOWN PROCEDURE RETURNED TO DEPARTURE. REPLACED SCAVANGE OIL FILTER ELEMENT AND OIL PRESSURE DIFFERENTIAL PRESSURE SWITCH IAW FIM TASK 79-35 FAULT TREE 803. LEAK CHECK OPS CHECK PENDINGSDR DALA2015040507863Floorbeam · damagedELONGATED HOLES AT BS 287 FLOORBEAM TO FRAME INTEGRATION AT RBL 85. REPAIR IAW ER/A 00-512821.
Back to Boeing 767-332