Boeing 767-34AF
Service difficulty reports · 6,321
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014011701451Cargo Track · wornC09 INSPECTION, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 879, LBL 11. REPAIRED IAW SRM 53-00-52, REPAIR 8, REV 58.00.SDR IPXA2014011701450Floor Panel · crackedC09 INSPECTION, FOUND CRACK DAMAGE ON CARGO FLOOR PANEL 232GFF AT BS 529 TO 654 +22, RBL 33 TO 54.75. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA2014011701449Floor Panel · crackedC09 INSPECTION, FOUND CRACK DAMAGE ON CARGO FLOOR PANEL 231FFF AT BS 529 TO 654+ 22, LBL 11 TO RBL 11. FABRICATED THE REPLACEMENT FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA2014011701448Floor Panel · crackedC09 INSPECTION, FOUND CRACK DAMAGE ON M/D CARGO FLOOR PANEL 231JFF AT BS 529 TO 654+ 22, LBL 54.75 TO 77.5. FABRICATED THE REPLACEMENT FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA2014011701447Floor Panel · crackedC09 INSPECTION, FOUND CRACK DAMAGE ON CARGO FLOOR PANEL 231BFF AT BS 412 TO 529 , LBL 11 TO 33. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA2014011701446Floor Panel · crackedC09 INSPECTION, FOUND CRACK DAMAGE ON CARGO FLOOR PANEL 231CFF AT BS 412 TO 529, LBL 33 TO 54.75. FABRICATE THE REPLACEMENT FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA2014011001250Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP.SDR IPXA2014010801213Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL DAMAGED. FABRICATED NEW FLOOR PANEL IAW EOB767-5320-53058-A.SDR IPXA2014010201191Latch · brokenCAPTAIN'S OVERHEAD ESCAPE ROPE DOOR LATCH INOPERATIVE. OVERHEAD PANEL ASSY R & R IAW AMM TASK 25-1 4-02. ROPE INSTALLED IAW AMM TASK 25-61-02-682-001, REV 110, 02.SDR IPXA2013122301111Transmitter · inoperativeAIR TURNBACK DUE TO FLAP ASSEMETRY INDICATION. LT T/E FLAP INDICATOR STAYED AT 15 DEGREES AND THE RT WENT TO 5 DEGREES. DETERMINED THAT THE FLAP SPLIT WAS INDICATION ONLY. R & R LEFT FLAP NR 1 POSITION TRANSMITTER IAW AMM 27-517-45. OPS CHECKED GOOD.SDR IPXA2013122001089Lamp · burned outEXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP, OP CHECKED NORMAL.SDR IPXA2013120200978Fan · failedAIR TURN BACK DUE TO FWD EQUIPMENT OVERHEAT AND SMOKE IN COCKPIT. R & R FWD PACK SUPPLY FAN IAW AMM 21-58-06 AND OPS CK NORMAL.SDR IPXA2013112700955Shutoff Valve · inoperativeAIR TURNBACK DUE TO FLAPS WOULD NOT MOVE WHEN SELECTED FROM 5 TO 10 DEGREES. REPLACED FLAP/SLAT SHUTOFF VALVE IAW AMM 27-51-48-022-001.SDR IPXA2013112700969Flap System · inoperativeATB -DURING CLIMB FLAPS WOULD NOT RETRACT. EMERGENCY DECLARED PERFORMED FSEU BITE IAW FIM 27-51-00-815. NO FAULTS NOTED. CYCLED FLAPS SEVERAL TIMES. SYS WORKING OK.SDR IPXA2013611010736Relay · inoperativeDURING CLIMBOUT, FLAP INDICATOR DISPLAYED POS 1 WITH THE FLAP LEVER IN THE UP OR ZERO POSITION. NO EICAS MESSAGE DISPLAYED. NO WARNINGS OR CAUTION LIGHTS ILLUMINATED. SPEED REMAINED WITHIN LIMITS. ACCOMPLISHED FIM27-58-00-815-803, UP TO BLK 36. PERFORMEDSDR IPXA2013311040760Window · failedCAPTAIN'S WINDOW AUDIBLY POPPED AND SEVERELY CRACKED AT FL 35, ENROUTE. R & R CAPTAIN`S L1 WINDOW. OPS CHECKED GOOD IAW MM 56-11-01-404-017.SDR IPXA2013103000721Lamp · inoperativeDURING MAINTENANCE INSPECTION, FWD EXTERIOR EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED LAMP IAW AMM 33-51-16-201, OPS CHECKED GOOD.SDR IPXA2013102800712Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LAMP, OPS GOOD IAW AMM 33-51-16-201.SDR IPXA2013102800696Bulb · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP & OPS CHECKED GOOD IAW AMM 33-61-16-201.SDR IPXA2013102500686Floor Panel · damagedINSPECTION C08, MAIN DECK CARGO FLOOR PANEL 252BFF DAMAGED AT BS 1109 - 1197+22, RBL 33- 54.75 FABRICATED FLOOR PANEL IAW B767-5320-9693-H.SDR IPXA2013102100653Floor Panel · damagedFLOOR PANEL 3, & 4R DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B767-5320-9693.SDR IPXA2013110100745Cargo Track · wornC08 INSPECTION, FOUND WORN OUT ON THE STUD HOLE OF CARGO TRACK AT BS 1197+66, LBL 77.50. REPAIR IAW SRM 53-00-52, REPAIR 9, REV 57.00.SDR IPXA2013101800612Warning Message · false activationFWD CARGO DOOR EICAS MESSAGE. LIGHT EXTINGUISHED AFTER APPROXIMATELY FIVE MINUTES WITH ACFT DEPRESSURIZED. EMERGENCY DECLARED VERIFIED FWD CARGO DOOR CLOSED AND LOCKED IAW DMP 52-71-1-1. PERFORMED BITE PROCEDURE FOR THE PSEU. NO CODE FOUND RELATED TO THE FWSDR IPXA2013101100544Strap · crackedINSPECTION TYPE:C08, CRACK ON THE FASTENER HOLE OF BULKHEAD OUTER CHORD STRAP (PN:148T2130 -6) NEAR STA 1725.50 AND STR-7R. REPAIR IAW 767-300F, SRM 53-80-01. REPAIR 5, REV.57.00 SR NR:2-253998286 & FAA FORM 8100-9.SDR IPXA2013100900517Spring · brokenDUE TO ABNORMAL PITCH RESPONSE VS CONTROL INPUT. ROUND SPRINGS 690, IAW CMM 27-31-09, BROKEN ON EICU FEEL UNIT. R &R SPRING IAW CMM. SYS TEST CHECKED GOOD IAW AMM 27-31-00-825-060, PAR 3, STEP B.SDR IPXA201310070495Skin · dentedC08 INSPECTION, T/E WEDGE LOWER SKIN OF RT WING INBD AFT FLAP AT IFS 141 DENTED. REPAIRED IAW SRM 57-53-01-2R-1, FIG 201,REV 57.00, 2, SRM 51-70-10-2R-4 FIG 201 SHEET 3, REV.57.00, 3. & SRM 51-70-03-0G, REV.57.00.SDR IPXA3680409Skin · dentedNR 3 SLAT T/E SKIN DENTED 144 INCHES FROM OTBD EDGE. REPAIR IAW EO B767-5750-52263-A.SDR IPXA3680402Skin · damagedNR 5 SLAT DENTED ON T/E WEDGE LOCATED 84 INCHES FROM OTBD EDGE AND 4.5 INCHES FROM T/E. REPAIRED IAW SRM 51-70-10-2R.SDR IPXA3680399Skin · damagedNR 1 L/E SLAT HAS 1" CUTOUT IN UPPER SKIN OF T/E WEDGE LOCATED 83.25" FROM INBD EDGE 7.5" FROM T/E REPAIRED IAW EO-B767-5750-52279-A.SDR IPXA2013110600767Skin · damagedNR 3 SLAT LOWER SKIN DAMAGED. REMOVED DAMAGE IAW SRM 57-43-02, FIG 201. OK TO INSTALL REPAIR C/W INSTALL PERMANENT REPAIR IAW B767 57-43-02, SEAL & PAINT IAW B767 57-43-02.SDR IPXA201310070494Floor Panel · damagedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL 241HFF, AT BS 833-929, LBL 37-39. FABRICATEED FLOOR PANEL IAW EO NR B767-5320-9693-H AND COMPLETE POTTED INSERT INSTALLATION IAW DWG 145T5876, REQUIREMENTS.SDR IPXA201310070493Floor Panel · crackedC08 INSPECTION, FOUND M/D CARGO FLOOR PANEL 241CFF CRACKED AT BS 731-833, LBL 37-39. FABRICATED FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070492Floor Panel · crackedC08 INSPECTION, FOUND M/D CARGO FLOOR PANEL 231HFF CRACKED AT BS 629-654+22, LBL 37-39. FABRICATE THE FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070491Floor Panel · damagedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL 231TFF AT BS 687-731,LBL 37-39. FABRICATED THE FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070490Floor Panel · crackedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL AT BS 654+22-686, LBL 37-39. . FABRICATED FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070489Floor Panel · damagedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL AT BS 929-970.5, LBL 37-39. FABRICATED FLOOR PANEL IAW EO NO B767-5320-9693-H AND COMPLETE POTTED INSERT INSTALLATION IAW DWG 145T5876.SDR IPXA201310070488Floor Panel · brokenC08 INSPECTION, FOUND BROKEN ON M/D CARGO FLOOR PANEL 241PFF AT BS 969.5-971, LBL 61.5-62.5. FABRICATE FLOOR PANEL IAW EO NT B767-5320-9693-H AND COMPLETE INSERT INSTALLATION IAW DWG 145T5876.SDR IPXA3680327Floor Panel · damagedFLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50.SDR IPXA3680255Floor Panel · damagedMCD FLOOR PANEL REPAIR AT POS 6 CTR LINE REF DEF 510990, FABRICATED NEW FLOOR PANEL REF EO B767-5320-9693-H.SDR IPXA3680236Actuator · inoperativeLIFE RAFT STOWAGE COMP. DOOR GAS ACTUATOR INOPERATIVE. R & R WITH NEW DOOR ACTUATOR IAW MM INTRO PG 1, PAR 1.SDR IPXA3680184Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA13680210Floor Panel · damagedMCD FLOOR PANEL DAMAGED. REMOVED DAMAGE IAW SRM 53-00-50-2R (D,2). DENTS REMOVED. C/W STEP 4-8, SRM 53-00-50-2R. REPAIR INSTALLED. PRECURED REPAIR DOUBLER IAW SRM 53-00-50-2R, PARA 4D, STEPS 9 & 10. CURE C/W OF REPAIR DOUBLER .SDR IPXA3680210Floor Panel · damagedPOS NR 6, AFT RT BL-4 MCD FLOOR PANEL DAMAGED.SDR IPXA3680175Floor Panel · damagedFLOOR PANEL NR 5 IS DAMAGED. FABRICATED FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA3680181Floorboard · dentedTWO DENTS IN FLOORBOARD 5.5 INCHES FROM RT EDGE. 46 INCHES FROM FWD/EDGE. REPAIR FLOORBOARD IAW SRM 53-00-50-2R.SDR IPXA3680171Floor Panel · damagedFLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA3680083Floor Panel · puncturedFLOOR PANEL HAS 1.5" X 1" PUNCTURE THRU FACE SHEET. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA3679981Skin · damaged.8 INCH HOLE IN NR 8 SLAT T/E WEDGE UPPER SKIN 45.8" FROM OTBD END AND 7.5" FWD OF T/E. REPAIRED IAW EO B767-5750-51892-A.SDR IPXA3679743Floor Panel · dentedINSPECTION TYPE:C08, FOUND DENT ON MAIN DECK CARGO FLOOR PANEL 252HFF AT BS 1197+70, RBL 83. REPAIR IAW EO B767-5320-9693-H.SDR IPXA3679742Floor Panel · dentedINSPECTION TYPE: C08, FOUND TWO DENTS ON MAIN DECK CARGO FLOOR PANEL 251UFF AT BS 1380, LBL 65 AND 70. . REPAIR IAW EO B767-5320-9693-H.
Back to Boeing 767-34AF