SDR IPXA13678209Floor Panel · crackedINSPECTION TYPE:C9. FOUND M/D CARGO FLOOR PANEL CRACKED AT BS 497, RBL 51.5-54. REPAIRED IAW EO NO B767-5320-9693-H.SDR IPXA13678208Floor Panel · dentedINSPECTION TYPE:C9, FOUND M/D CARGO FLOOR PANEL DENTED BETWEEN BS 412 AND 456, RBL 28. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA13678207Floor Panel · dentedINSPECTION TYPE:C9, FOUND M/D FLOOR PANEL DENTED BETWEEN BS 685 AND 690, RBL 17. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA13678206Floor Panel · dentedINSPECTION TYPE:C9, FOUND M/D CARGO FLOOR PANEL DENTED BETWEEN BS 654+22 AND 654+66, LBL 88. REPAIRED IAW EO NO B767-5320-9693-H.SDR IPXA13678205Floor Panel · dentedINSPECTION TYPE:C9, M/D CARGO FLOOR PANEL DENTED BETWEEN BS 370 AND 412, RBL 28. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA13678129Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 6C HAS A .3750" HOLE 5 INCHES AFT OF YELLOW LINE. REPAIRED IAW SRM 53-00-50-2R PAR 4B.SDR IPXA13678128Floor Panel · damagedMAIN CARGO DECK POS 6L NR 3 FLOOR PANEL HAS A .2500" HOLE 25 INCHES AFT OF RED LINE. REPAIRED REF SRM 53-00-50-2R, PAR 4B.SDR IPXA13678125Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL HAS 2.5 X .5 HOLE THRU TOP SKIN & CORE. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA13678108Cooling Fan · failedFUMES DETECTED IN COCKPIT AT FL 390. REPLACED FWD EQUIPMENT COOLING FAN IAW MM 21-58-06. OPS CHECKED GOODSDR IPXA3678108Cooling Fan · fumesCOOLING FAN PRODUCED FUMES IN COCKPIT AT FL 390 . OPENSDR IPXA13678203Skin · dentedINSPECTION TYPE:C9, LT WING NR 2 SLAT T/E WEDGE ASSY UPPER SKIN DENT AT OSS 916.DAMAGE SIZE IS MEASURED AS 0.5" (LENGTH) X 0.5" (WIDTH) AND THE CUTUOT IS MEASURED AS 0.6" DIAMETER. REPAIRED IAW SRM 57-43-02, REPAIR 1 AND 51-70-10, REPAIR 2, FIG 203, REV 56.SDR IPXA3678264Failsafe · damagedINSPECTION TYPE:C08, DURING WORK OF SB 53-0116 & REQUIREMENT OF SB 53A0100, FOUND CORROSION DAMAGE TO SKIN COMMON TO FAILSAFE STRAP INTERFACING SURFACE FROM S-20R TO OVERWING LONGERON. CORROSION DAMAGE TO REAR SPAR SIDE FRAME FITTING COMMON TO INTERFACING SURSDR IPXA13677984Floor Panel · dentedINSPECTION TYPE:C08. CARGO FLOOR PANEL DENTED BS 988 - 1004, LBL 82. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA13677983Floor Panel · delaminatedINSPECTION TYPE:C08, CARGO FLOOR PANEL DELAMINATED BS 1480, RBL 11. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA13677982Floor Panel · dentedINSPECTION TYPE:C08, CARGO FLOOR PANEL DENTED BETWEEN BS 1120 AND 1180, LBL 34 - RBL 45. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA13677981Floor Panel · dentedINSPECTION TYPE:C08, CARGO FLOOR PANEL DENTED BETWEEN BS 1520, LBL 55. REPAIRED IAW EO NO B767-5320-9693-H.SDR IPXA13677980Floor Panel · dentedINSPECTION TYPE:C08, FOUND CARGO FLOOR PANEL DENTED BETWEEN BS 1410 AND 1473, LBL 35 - 54. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA13677979Floor Panel · dentedINSPECTION TYPE:C08, FOUND CARGO FLOOR PANEL DENTED BETWEEN BS 1215 AND 1294, LBL 23-31. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA13677978Floor Panel · dentedINSPECTION TYPE:C08, MAIN DECK CARGO FLOOR PANEL DENTED BS 1480, RBL 54. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA13677976Floor Panel · dentedINSPECTION TYPE:C08, MAIN DECK CARGO FLOOR PANEL DENTED BETWEEN BS 1197+25 AND 1197 +45, LBL 8 - RBL 8. REPAIRED IAW EO NO B767-5320-9693-H.SDR IPXA13677975Floor Panel · dentedINSPECTION TYPE:C08, FOUND CARGO FLOOR PANEL BETWEEN BS 998 AND 1003,BL 0 -LBL 5 DENTED. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA13677934Floor Panel · damagedINSPECTION TYPE:C9, FOUND TWO HOLES ON MAIN DECK CARGO FLOOR PANEL AT BS 453, RBL 83.5. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA13677933Floor Panel · damagedINSPECTION TYPE:C9, FOUND TWO HOLES ON MAIN DECK CARGO FLOOR PANEL AT BS 630, RBL 83.5. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA13678238Stringer · crackedINSPECTION TYPE:C08, CRACK 1.1 INCHES, WAS FOUND ON STRINGER 20L BETWEEN BS 1502 AND 1518. REPAIR IAW SR 1-2419267958.SDR IPXA13677787Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL HAS LARGE HOLE THROUGH BOTH SKINS AND CORE. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA3677822Spar · damagedLT OTBD AILERON L/E SPAR UPPER SURFACE AT WS 923.34 TO 940, NINE WORN DAMAGED AREAS WERE FOUND.SDR IPXA3678257Bulkhead · crackedINSPECTION TYPE:C08, CRACK (0.65") WAS FOUND ON LT HORIZONTAL INNER CHORD OF STA 1809.5 BULKHEAD AT APPROX WL 257 AND LBL 28. THE CRACK WAS EXTENDED FROM THE FASTENER HOLE THRU THE EDGE OF INNER CHORD. REPAIR IAW SRM 53-80-08, REPAIR 10, REV 56.SDR IPXA3677768Audio Panel · interferenceEMERGENCY DECLARED FOR A SLAT ASSYMETRIC INDICATION. CREW PERFORMED CHECKLIST. CONTINUED APPROACH AND LANDED WITHOUT INCIDENT. FOUND THE 1ST OBS AUDIO SELECTOR PANEL PRODUCES ABNORMAL EMI THAT IS CAUSING PSEU SENSOR FAULTS WHEN RUDDER TRIM IS SELECTED. DUPLISDR IPXA3677713Floor Panel · puncturedMAIN DECK FLOOR PANEL POS 4R HAS A .500 DIA PUNCTURE INTO CORE. FABRICATED FLOOR PANEL IAW EO-B767-5320-9693-H.SDR IPXA3677601Floorboard · damagedPOS 6L 3RD FLOORBOARD IN FROM OTBD 3 INCHES FWD OF CTR LINE HAS .2500" HOLE INTERIM REPAIR. REPAIRED IAW EO B767-5320-50236-A AND EO B767-5320-9693-H.SDR IPXA3677672Unknown · odorINSPECTION TYPE:ETOP ELECTRICAL BURNING ODOR NOTED IN FLIGHT. BOTH PACKS RUNNING. ODOR DISSIPATED THEN NOTICED MORE STRONGLY UPON BLOCK IN. AFTER BLOCK IN, ODOR WAS STRONGER IN AFT RT TUNNEL OF E/E BAY. COULD NOT PIN POINT SOURCE. RAN BOTH ENGINES, PACKS. APSDR IPXA3677580Sensor · inoperativeDURING CLIMB FL 300 FWD CARGO DOOR EICAS MESSAGE. PERFORMED CHECKLIST AND PROCEDURES. DIVERTED. R & R DOOR LATCHED SENSOR IAW MM 52-71-02 AND OPS CHECKED NORMAL. ADJUSTED IAW MM 52-71-02. OK FOR SERVICE.SDR IPXA13677580Warning Message · illuminatedDURING CLIMB FL 300 FWD CARGO DOOR EICAS MESSAGE. PERFORMED CHECKLIST AND PROCEDURES. ACFT DIVERTED. OPENSDR IPXA13677574Seat Track · corrodedINSPECTION TYPE:C09 FOUND CORROSION ON RBL 88 SEAT TRACK AT BS 522 AND 566. REPAIRED IAW EO NR B767-5310-50212-A.SDR IPXA13677562Battery · inoperativeEMERGENCY LIGHTS WILL NOT TEST. R & R BATTERY ASSY IAW AMM 33-51-07-022-001. OPS GOOD.SDR IPXA13677530Skin · damagedLT WING INBD AFT FLAP LWR SKIN DAMAGED. REPAIRED IAW EO B767-5750-45073-C.SDR IPXA3677481Floor Panel · dentedINSPECTION TYPE:C01 2 DENTS ON M/D CARGO FLOOR PANEL 231FFF. REPAIRED IAW EO NR B767-5320-9693-H.SDR IPXA3677449Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL BETWEEN 8-9L HAS 2 INCH HOLE. FABRICATED FLOOR PANEL IAW EO B767-5320-9693-H AND REPLACED.SDR IPXA3677445Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL P7 HAS TWO HOLES IN CENTER. FABRICATED A NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA3677444Floor Panel · damagedMAIN CARGO DECK POS 7 HAS HOLE IN RT OTBD FLOOR PANEL. FABRICATED NEW FLOOR PANEL, REF EO B767-5320-9693-H.SDR IPXA3677437Skin · dentedINSPECTION TYPE:C01, A DENT WAS FOUND ON LT WING NR 3 SLAT UPPER SURFACE OF WEDGE AREA. DAMAGE SIZE IS MEASURED AS 1.75"(LENGTH) X 1.5"(WIDTH) X 0.031"(DEPTH) AT OSS 807. REPAIRED IAW SRM 57-43-02, REPAIR 1 AND 51-70-10, REPAIR 4, FIG 201, REV 55.SDR IPXA3677436Skin · dentedINSPECTION TYPE:C01, A DENT WAS FOUND ON LT WING NR 3 SLAT UPPER SURFACE OF WEDGE AREA. DAMAGE SIZE MEASURED AS 0.88" (LENGTH) X 0.62"(WIDTH) X 0.025" (DEPTH) AT OS S 804.5 REPAIR IAW SRM 57-43-02, REPAIR 1 AND 51-70-10, REPAIR 4, FIG 201, REV 55.SDR IPXA3677435Skin · dentedINSPECTION TYPE:C01, A DENT WAS FOUND ON LT WING NR 3 SLAT UPPER SURFACE OF WEDGE AREA. DAMAGE SIZE MEASURED AS 0.62" (LENGTH) X 0.55" (WIDTH) X 0.012"(DEPTH) AT OSS 805.5 REPAIRED IAW SRM 57-43-02, REPAIR 1 AND 51-70-10, REPAIR 4, FIG 201, REV 55.SDR IPXA3677434Skin · dentedA DENT WAS FOUND ON LT WING NR 3 SLAT UPPER SURFACE OF WEDGE AREA. DAMAGE SIZE IS MEASURED AS 0.78" (LENGTH) X 0.55" (WIDTH) X 0.012" (DEPTH) AT OSS 801.5. REPAIR IAW 767-300F SRM 57-43-02, REPAIR 1 AND 51-70-10, REPAIR 4, FIG 201, REV 55.SDR IPXA3677431Wedge · dentedINSPECTION TYPE:C01, LT WING NR 3 SLAT T/E WEDGE ASSY UPPER SKIN DENTED AT OSS 819. DAMAGE SIZE IS MEASURED AS 1.0" (LENGTH) X 0.66"(WIDTH) X 0.013"(DEPTH) AND THE CUT OUT IS MEASURED AS 1" DIAMETER. REPAIR IAW SRM 57-43-02, REPAIR 1 AND 51-70-10, REPAIR 4 FISDR IPXA13677280Escape Rope · frayedMAIN DOOR INGRESS ROPE FOUND FRAYED & TANGLED. R & R DOOR INGRESS ASSY IAW MM 25-61-04-002-003 AND 25-61-04-402-013SDR IPXA13677279Cover · tornMAIN ENTRY DOOR INGRESS ROPE FABRIC COVER TORN. R & R INGRESS ROPE COVER IAW AMM 25-61-01 & VERIFIED IPC 25-20-61-01, ITEM 080.SDR IPXA13677247Escape Rope · frayedREMOVED ROPE FWD ENTRY DOOR EMERGENCY/ESCAPE AND CHANNEL DUE TO ROPE & COVER RIPPED AND FRAYED. R & R ROPE CHANNEL EMERGENCY ESCAPE IAW AMM 25-61-04, PN ON 416T1601-6, SN ON TAG 058615A.SDR IPXA13677290Floor Panel · crackedINSPECTION TYPE:C08, CRACK-FOUND A CRACK ON CARGO FLOOR PANEL 251CFF AT BS 1118 AND LBL 34.5. THE DIMENSION OF CRACK LENGTH IS APPROX 6". REPAIRED IAW EO NO B767-5320-9693-H.SDR IPXA13677289Floor Panel · dentedINSPECTION TYPE:C08, DENT-FOUND A DENT ON CARGO FLOOR PANEL 251XFF AT BS 1491 AND LBL 84. THE DIMENSION OF DENT IS 4 IN(L) X 3 IN(W) X 0.214 IN(D). REPAIRED IAW EO B767-5320-9693-H.
Back to Boeing 767-34AF