Boeing 767-34AF
Service difficulty reports · 6,321
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2675132Floor Panel · gougedMAIN CARGO DECK POS 10R OTBD FLOOR PANEL GOUGED. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675131Floor Panel · gougedMAIN CARGO DECK POS 11R OTBD FLOOR PANEL HAS 2 INCH GOUGE. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675130Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 10R MID OTBD HAS HOLE. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675129Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 11L HAS HOLE. COMPLIED WITH EO B767-5320-9693-H.SDR IPXA2675128Floor Panel · gougedFLOOR PANEL FROM OTBD HAS GOUGED. COMPLIED WITH EO B767-5320-9693, FABRICATED NEW FLOOR PANEL.SDR IPXA2675127Floor Panel · damagedFLOOR PANEL POS 9R FWD HAS HOLE LESS 3 IN PANEL IS FROM POS 9R, FABRICATED REPLACMENT FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675126Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL AT POS 10R FWD OTBD HAS 2 GOUGES AND DENTS. FABRICATED REPLACMENT FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675125Floor Panel · gougedMAIN CARGO DECK FLOOR PANEL AT POS 14 SECOND PANEL FROM L/E LT HAS 2 GOUGES. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675124Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL AT POS 8, LT OTBD HAS A HOLE IDENTIFED PANEL FROM POS 8 LT OTBD. FABRICATED REPLACMENT FLOOR PANEL IAW EO B767-5320-9693H.SDR IPXA2675122Doubler · damagedDOUBLER DAMAGED AT BS 450. REPAIR IAW EO B767-5330-48402-A.SDR IPXA2675151Relay · inoperativeDURING CONFIGURATION FOR LANDING RECEIVED L/E SLAT ASYM MESSAGE. COMPLETED L/E SLAT ASYM CHECKLIST. NO FURTHER PROBLEMS IAW FIM. L/E SLAT SYS EICAS MSG L/E SLAT ASYM DISPLAYED L/E LGT ON WITH FLAP LEVER IN 1. BOTH FLAP POINTERS WERE CORRECT. EMERGENCY DECLASDR IPXA2675096Blade · damagedINSPECTION TYPE: ETOP ATB - NR 1 ENGINE BIRD STRIKE, EMERGENCY DECLARED. ACFT IS OOS. REPLACED 14 DAMAGED FAN BLADES ON NR 1 ENGINE; REPAIRED DAMAGE TO ACCOUSTIC LINER AFT OF FAN BLADES; BOROSCOPED ENGINE CORE AND UN-SHINGLED 12 TO 16 HPC 1ST STAGE BLADES.SDR IPXA12675096Engine · bird ingestionNR 1 ENGINE BIRD STRIKE, EMERGENCY DECLARED. OPEN.SDR IPXA2675048Door · out of sequenceCREW ENTRY DOOR OUT OF SEQUENCE, DOOR WILL NOT OPEN. PUT CEILING PANEL AND DOOR BACK IN SEQUENCE IAW AMM 52-12-34-404-014 OPS CHECKED GOOD.SDR IPXA12674933Adi · inoperativeAIR TURN BACK DUE TO CAPTAIN`S ADI INOPERATIVE, POPPING AND CRACKLING HEARD, AND AN ELECTRICAL ODOR FOR BRIEF PERIOD. WHEN BLOCK IN, FOUND CAPT ADI CIRCUIT BREAKER TRIPPED, TROUBLE SHOT IAW FIM 34-12, TASK 818. FOUND CAPTAIN`S ADI BAD. R & R AND TESTED OK ISDR IPXA2674863Sensor · malfunctionedON APPROACH PASSING THROUGH 6000 FT, CREW RECEIVED A SLAT ASYMMETRY WARNING. CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. REPLACED SPLICES SM7 AND SM9 FOR SALT PROXIMITY SENSORS S295 AND S294, REF WDM 27-88-22 AND SWPM 20-35-20. ALSO REF BOX TS2741SDR IPXA12674753Cooling Fan · inoperativeAFTER TAKEOFF FWD EQUIPMENT COOLING EICAS MESSAGE APPEARED, RAN QRH AND MESSAGE REAPPEARED, ACFT LANDED. IAW QRH TROUBLESHOOTING FWD EQUIPMENT COOLING IAW FIM 21-58-00-815-831-001-004-133. ALL TEST NOW PASS OK. OK FOR SERVICE.SDR IPXA2674843Floor Panel · damagedMAIN CARGO DECK POS 12L HAS A HOLE IN FLOOR PANEL AFT SIDE ON 2ND PANEL D408945. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA12674745Floor Panel · tornMAIN CARGO DECK FLOOR PANEL, BS 1263 HAS A TEAR. FABRICATED NEW PANEL IAW EO B767-5320-9693-H.SDR IPXA12674744Floor Panel · tornFLOOR PANEL, BS 1307 HAS A TEAR. FABRICATED NEW FLOOR PANEL IAW EO 767-5320-9693-H.SDR IPXA12674743Floor Panel · damagedFLOOR PANEL, BS 1463, POS 10-11, CTR HAS A HOLE PN 146T58 69-78. FABRICATED NEW FLOOR PANEL IAWEO 767-5320-9693-H.SDR IPXA12674732Floor Panel · damagedMAIN DECK CARGO FLOOR PANEL DAMAGED. FABRICATED FLOOR PANEL REF EO B767-5320-9693-H.SDR IPXA12674815Fairing · delaminatedINSPECTION TYPE:9C LT WING OTBD FLAP INBD L/E FAIRING DELAMINATED AT 55.5" FROM INBD EDGE. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PARA 5A(1), FIG 5, REV 52.SDR IPXA12674814Fairing · delaminatedINSPECTION TYPE:9C, LT WING OTBD FLAP MID L/E FAIRING DELAMINATED AT 119.5" FROM INBD EDGE. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PARA 5A(1), FIG 5, REV 52.SDR IPXA12674813Fairing · delaminatedINSPECTION TYPE: 9C, LT WING OTBD T/E FLAP MID L/E FAIRING DELAMINATED AT 119.5" FROM INBD EDGE. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM51-70-05, PARA 5A(1), FIG 5, REV 52.SDR IPXA12674812Fairing · delaminatedINSPECTION TYPE: 9C, LT WING OTBD FLAP MID L/E FAIRING DELAMINATED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05 PARA 5A(1), FIG 5, REV 52.SDR IPXA12674811Fairing · delaminatedINSPECTION TYPE:9C, LT WING OTBD FLAP INBD L/E FAIRING DELAMINATED 28.5" FROM INBD EDGE. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PARA 5A (1) FIG. 5, REV 52.SDR IPXA12674810Skin · crackedINSPECTION TYPE: 9C, NR 2 PYLON LT STRUT SKIN CRACKED APPROX 1.5" LONG AT ACCESS PANEL NR 442AL CUTOUT. REPAIRED IAW HX RS R-54-51-37402 REV A & EO B767-5430-48154-A JUST AT ACCESS PANEL NR 442AL CUTOUT AFT UPR CORNER AREA, SKIN & DOUBLER ORIG MATL ARE CLAD 2SDR IPXA12674789Skin · crackedINSPECTION TYPE: 9C, EMP STA-1725, STR-7R SKIN FOUND CRACKED. REPAIRED IAW SRM 53-80-01-2R-5 REPAIR 5 FIG 201, REV 53 AT BS 1725.5, STR-7R AREA, SKIN CRACK LENGTH 2.2", CHORD STRAP CRACK LENGTH 0.25", FINAL CUTOUT SIZE 3" X 4.25" & CHORD STRAP 1" X 1". CLASSISDR IPXA12674788Stiffener · crackedINSPECTION TYPE:9C, FUSELAGE RT STA 287, BL 25 NLG WW AFT BULKHEAD VERTICAL CHORD CRACK FOUND AT WL 173 APPROX .5" IN LENGTH. REPAIRED IAW SRM 51-70-12-0G, FIG 1, REV 52 JUST BTW WL 164 & WL 182, ORIG MATL: AND10140-4005-7075T6511, CRACK LENGTH: 0.75", FINAL SDR IPXA12674773Fairing · delaminatedINSPECTION TYPE: 9C, LT WING OTBD FLAP INBD L/E FAIRING DELAMINATED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PAR 5A (1), FIG 5, REV 52.SDR IPXA12674772Fairing · delaminatedINSPECTION TYPE:9C, RT WING INBD MAIN FLAP OTBD L/E FAIRING DELAMINATED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PAR 5A (1), FIG 5, REV 52.SDR IPXA12674771Wedge · delaminatedINSPECTION TYPE: 9C, RT WING OTBD FLAP T/E WEDGE MID AREA LOWER SURFACE DELAMINATED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5A (1), FIG 9, REV 52.SDR IPXA2674687Contact · dirtyTRAILING EDGE FLAP SYS EICAS MESSAGE T/E FLAP ASYM DISPLAYED. T/E LIGHT ON. NO FLAP MOVEMENT - EMERGENCY DECLARED. REMOVED FSEU AND CLEANED CONTACTS REINSTALLED FSEU AND OPS CHECKED IAW MM27-51-01-404-130.SDR IPXA12674816Floorboard · puncturedINSPECTION TYPE:9C, MAIN CARGO 4L, BS 540-654+22, L33 TO L55, HAS PUNCTURED FLOORBOARD. FLOORBOARD FABRICATED IAW EO B767-5320-9693H AND INSTALLED IAW AMM 53-01-06.SDR IPXA2674640Skin · damagedRUDDER T/E SKIN DAMAGED ON UPPER RT SIDE 12" UP FROM BOTTOM EDGE. REPAIRED IAW EO B767-5540-47177-B.SDR IPXA2674638Transceiver · inoperativeWEATHER RADAR FAIL DISPLAYED ON BOTH LOWER CRT AND WX S/R. DISPLAYED ON STATUS MESSAGE ON CLIMB OUT AND CRUISE. RADAR ON WX MODE, AND RANGE MODE MORE THAN 40 WOULD GIVE WXR FAIL. REMOVED RADAR TRANSCEIVER AND REPLACED WITH KNOWN GOOD UNIT FROM AC 302UP (SESDR IPXA2674637Control Panel · inoperativeWEATHER RADAR FAIL TRWS FORECAST ENROUTE. WEATHER RADAR FAILED ON HSI OK IN TEST. R & R WEATHER RADAR CONTROL PANEL IAW AMM 34-43-00-501.SDR IPXA2674591Skin · delaminatedINSPECTION TYPE: 7C, RT WING OTBD FLAP INBD LOWER PANEL INTERNAL FOUND DELAMINATED. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R. REPAIR 4, FIG 201, SHEET 3, REV 52.SDR IPXA12674550Stiffener · crackedINSPECTION TYPE: 7C, FUSELAGE MAIN EQUIPMENT CENTER STA 246 LBL 40 FLOORBEAM FWD FACE STIFFENER FOUND CRACKED. REPAIRED IAW SRM 53-10-51-2R4, REPAIR 4, FIG 201, REV 52, ORIG MATL IS BAC1490-2793-7075T62, CRACK LENGTH: 1.1", WITH MATERIAL CLAD 7075T6-0063" AS SDR IPXA2674383Floor Panel · damagedFLOOR PANEL, POS 2L, 3RD OTBD DAMAGED. FABRICATED FLOOR PANEL IAW EO B767-5320-9693-H AND REPLACED.SDR IPXA2674382Floor Panel · damagedFLOOR PANEL POS9 AFT CTR DAMAGED. FABICATED FLOOR PANEL IAW EO B767-5320-9693-H AND REPLACED.SDR IPXA2674405Skin · dentedRT WING INBD AFT FLAP DENTED. REPAIRED IAW EO B767-5750-47002-B.SDR IPXA2674404Skin · dentedLT WING INBD T/E FLAP DENTED. REPAIRED IAW EO B767-5750-47001-B.SDR IPXA2674225Floor Panel · damagedFLOORBOARD POS 12.2500 HAS A HOLE, REPAIRED IAW SRM 53-00-53-2R.SDR IPXA2674224Floor Panel · damagedPOS 10, FLOORBOARD 20" FWD OF POS 10/11 LBL DAMAGED. REPAIRED IAW SRM 53-00-50-R2.SDR IPXA2674223Floor Panel · crackedFLOOR PANEL HAS A .7500" CRACK 24" AFT OF POS 3/4, LBL 6.7500" DAMAGE SIZE, REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2674222Floor Panel · damagedHOLE IN FLOOR PANEL POS 9 42" FWD OF POS 9/10 RBL 5, REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2674221Floor Panel · damagedFLOOR PANEL 6R HAS HOLE .25" FWD OF POS 6/7 RBL 48, 1" DIA HOLE CUTOUT, REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2674220Floor Panel · damagedFLOORBOARD POS NR 9, 3" FWD OF POS 9/10 LBL 47 DAMAGED. REPAIRED IAW SRM 53-00-50-2R.
Back to Boeing 767-34AF