SDR UIEA2017103102150Pitot Head · inoperativeFIRST OFFICER`S PITOT HEAT INOPERATIVE. REMOVED AND REPLACED THE PITOT TUBE IAW AMM 34011-01, OPS AND LEAK CHECKED GOOD IAW 34-11-00-501, NO LEAKS NOTED.SDR UIEA2017102101989Radar · malfunctionedLEFT WEATHER RADAR DURING DESCENT, PAINTED A 15 MILE ARC DURING NUMEROUS HEADING CHANGES , DID NOT TRY THE RT RADAR. PERFORMED A WEATHER RADAR TEST IAW AMM 34-43-00, OPS CHECKED GOOD ON GROUND.SDR UIEA2017102001987Pump · warning messageRT AFT FUEL PUMP EICAS MESSAGE. REMOVED AND REPLACED RIGHT AFT FUEL PUMP PRESSURE SWITCH IAW AMM 28-42-01. OPS CHECKED GOOD, NO LEAKS NOTED.SDR UIEA2017101901981Shutoff Valve · failedRIGHT ENGINE IDG OUT TEMP MAINTENANCE MESSAGE. REMOVED AND REPLACED THE NR 2 ENGINE AIR SHUTOFF VALVE IAW AMM 24-11-07, OPS CHECKED GOOD.SDR UIEA2017101901982Squib · no testOVERWING SQUIBS WILL NOT TEST. DISARMED AND REARMED THE OVERWING ESCAPE SYSTEM IAW AMM 25-65-00. OPS CHECKED GOOD.SDR UIEA2017101301962Warning Message · false activationIDLE DISAGREE EICAS MESSAGE ON LANDING. RAN FIM 22-03 F/T'S 803 & 810, TESTS 2 & 10 ON MCDP. OPS CHECKED NORMAL.SDR UIEA2017101101947Heat Exchanger · leakingLEFT DUCT LEAK AFTER LANDING. REMOVED AND REPLACED THE SECONDARY HEAT EXCHANGER. LEFT SIDE IAW AMM 21-51-02. NO LEAKS, OPS CHECKED NORMAL.SDR UIEA2017101201954Warning Message · false activationRIGHT ENGINE IDG OUT TEMP. RT ENG READING HIGH. PERFORMED 24-26 FAULT TREE 807, OUT TEMP DISPLAY. NO FAULT ON WIRING NOTED. RESISTANCE CHECKED WITHIN LIMITS. OPS CHECKED NORMAL.SDR UIEA2017100701937Warning Message · false activationIDG OUT TEMP MTC MESSAGE, RT ENGINE READING HIGH. CONFIRMED IDG SERVICING IAW AMM 12-13-03, COMPLIED WITH FIM 24-20 FT 807, NO FAULTS NOTED, IDG OK FOR SERVICE.SDR UIEA2017100401928Switch · inoperativeFWD CARGO HEAT OV/HEAT INOP. R&R SWITCH ASSY FOR FWD CARGO HEAT, OPS CKD GOOD PER AMM 33-13-00.SDR UIEA2017100101910Pressure Switch · leakingAPU HAS AN OIL LEAK, FOUND ON POST ACFT POSITIONING WALK AROUND. R & R THE OIL PRESSURE SWITCH IAW AMM 49-94-02, LEAK CHECKED GOOD.SDR UIEA2017092501855Pressure Switch · leakingOIL LEAK FROM THE APU. R & R THE OIL PRESSURE SWITCH, OPS CHECKED GOOD, LEAK CHECKED GOOD IAW AMM 49-94-02.SDR UIEA2017091101632Control Valve · malfunctionedRIGHT PACK OFF LIGHT WITH ALL OTHER PARAMETERS NORMAL AND PACK RUNNING. REPLACED THE RIGHT PACK FLOW CONTROL VALVE IAW AMM 21-51-01. OPS CHECKED NORMAL.SDR UIEA2017091001625Idg · malfunctionedRIGHT GENERATOR DRIVE EICAS MESSAGE ILLUMINATED AFTER RIGHT ENGINE START AND STAYS ON FOR 2 TO 3 MINUTES. REMOVED AND REPLACED THE RIGHT IDG IAW AMM 24-11-01, ENGINE RUN AND GENERATOR GROUND OPERATIONS NORMAL.SDR UIEA2017090801622Circuit Card · failedRIGHT PACK OFF LIGHT ILLUMINATED. REMOVED AND REPLACED THE RT PACK FLOW CONTROL CARD IAW AMM 21-51-09. OPS CHECKED GOOD.SDR UIEA2017090601608A/C Pack · malfunctionedRIGHT A/C PACK OFF MESSAGE. A/C PACK RESET & BITE TEST CARRIED OUT IAW AMM 21-51-00. NO ACTIVE MESSAGES, OK FOR SERVICE.SDR UIEA2017082801561Actuator · failedAPU FAILED ON START FIRST ATTEMPT, APU DOOR STATUS MESSAGE. REMOVED AND REPLACED THE AIR INTAKE DOOR ACTUATOR IAW AMM 49-15-06. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR UIEA2017082501542Clamp · looseRIGHT DUCT LEAK AND ASSOCIATED EICAS MESSAGE DISPLAYED WHEN PARKED ON RAMP , QRH PROCEDURE COMPLIED WITH. FOUND LOOSE CLAMP ON THE RT ISOLATION VALVE , TIGHTEN THE CLAMP IAW AMM 36-11-04, OPS CHECKED SATISFACTORY, NO FURTHER MESSAGES.SDR UIEA2017082801562Warning Message · false activationAPU DOOR MESSAGE SELF ERASED AFTER RESET OF CIRCUIT BREAKER AND BITE TEST OF ECU IAW AMM 49-61-05. OPS CHECKED GOOD.SDR UIEA2017082401536Apu · malfunctionedAPU FAILED TO START, 2 ATTEMPTS. APU DOOR STATUS MESSAGE. RESET DOOR INLET CIRCUIT BREAKER & BITE TESTED THE APU ECU IAW AMM 49-61-05. OPS CHECKED SATISFACTORY.SDR UIEA2017081701500Circuit Breaker · trippedAPU WOULD NOT START AFTER FLIGHT , APU DOOR STATUS MESSAGE. FOUND APU DOOR CIRCUIT BREAKER TRIPPED, RESET, STARTED APU SEVERAL TIMES AND CHECKED GOOD IAW AMM 49-41-00</P>)SDR UIEA2017081401481Actuator · failedWHILE ATTEMPTING TO START APU. APU DOOR ACTUATOR CIRCUIT BREAKER TRIPPED. R & R APU DOOR ACTUATOR IAW AMM 49-15-06, OPS CHECKED GOOD.SDR UIEA2017090501596Warning Message · false activationRIGHT PACK OFF MESSAGE. RT PACK RESET & A BITE TEST WAS CARRIED OUT IAW AMM 21-51-01. NO ACTIVE MESSAGES, OK FOR SERVICE.SDR UIEA2017080301413Isolation Valve · malfunctionedRIGHT BLEED ISLN VAL EICAS CAUTION MSG WHILE STILL ON THE BLOCK. REMOVED AND REPLACED RIGHT ISOLATION VALVE IAW AMM 36-11-04. OPS AND LEAK CHECK GOOD.SDR UIEA2017072801345Controller · false indicationEICAS MESSAGE FOR THE L2 SIDE WINDOW. QRH PROCEDURES ACCOMPLISHED. REMOVED AND REPLACED LT WINDOW HEAT CONTROLLER IAW AMM 30-41-01, OPS CHECKED GOOD.SDR UIEA2017072701326Warning Message · false activationEICAS MESSAGE FOR THE LT SIDE WINDOW DISPLAYED. ACCOMPLISHED QRH. PERFORMED FIM 30-41 FT 804 AND BITE TEST. HEAT CONTROLLES. NO FAULTS NOTED. WINDOW HEAT OK.SDR UIEA2017072601319Idg · lowRIGHT GENERATOR DRIVE LIGHT AND EICAS MESSAGE ILLUMINATED AND SHOWN APPROX FOR 90 SECONDS AFTER ENGINE START. SERVICED THE RT IDG OIL IAW AMM 12-13-03, NO DISCREPANCIES NOTED.SDR UIEA2017072801344Apu · malfunctionedAPU SHUTDOWN UNCOMMANDED ON RAMP. PERFORMED BITE TEST OF APU CONTROL UNIT IAW AMM 49-61-05, 49-61-05-742-027. NO FAULTS FOUND.SDR UIEA2017072101259Indicator · inoperativeLEFT ENGINE SPAR VALVE LIGHT INOPERATIVE.SDR UIEA2017072001247Gcu · unknownREMOVED AND REPLACED RT GENERATOR CONTROL UNIT IAW AMM 24-22-02 OPS CHECK GOOD IAW AMM 71-00-00 NO FUTHER DEFECT NOTED AT THIS TIME.SDR UIEA2017072101251Warning Message · false activationLEFT SIDE WINDOW EICAS. PERFORMED FIM 30-41 FT 804 &. CHECKED WINDOW HEAT CONTROLLER, NO FAULT NOTED. OPS CHECKED OK.SDR UIEA2017071701232Sensor · malfunctionedLEFT SIDE WINDOW EICAS MESSAGE DISPLAYED. ACCOMPLISHED QRH, PERFORMED FIM 30-41 FT 804, TASK 802, SWAPPED LT WINDOW NR 3 TO SPARE SENSOR IAW AMM 30-41-00, OPS CHECKED NORMAL AT THIS TIME.SDR UIEA2017071301218Warning Message · false activationLEFT SIDE WINDOW EICAS MESSAGE. ACCOMPLISHED QRH. PERFORMED BITE ON THE WINDOW HEAT CONTROLLER, NO FAULTS. WINDOW HEAT CHECKED NORMAL IAW AMM 30-41-01.SDR UIEA2017070301092Warning Light · false activationLEFT SIDE WINDOW CAUTION MESSAGE ON EICAS DURING FLIGHT. WINDOW HEAT CONTROL UNIT BITE TEST CARRIED OUT IAW AMM 30-41-01, NO FAULTS, OK FOR SERVICE.SDR UIEA2017062901073Idg · underservicedRIGHT GENERATOR DRIVE EICAS MESSAGE, AFTER START. EXTINGUISHED IN 60 SECONDS. PERFORMED A RT IDG OIL SERVICING IAW AMM TASK 12-13-03-613-027.SDR UIEA2017063001075Warning Message · false activationRT AFT FUEL PUMP MESSAGE DURING FLIGHT, COMPLIED WITH QRH. PERFORMED SYSTEM TEST IAW FIM 28-22-820. NO FAULTS NOTED. OK FOR SERVICE.SDR UIEA2017062901072Warning System · false activationR AFT FUEL PUMP MSG INFLIGHT C/W QRH, PERFORMED SYSTEM TEST & IAW AMM 28-22-820. NO FAULTS NOTED OK FOR SERVICES.SDR UIEA2017052700863Apu · faultedAPU SHUTDOWN WITH A FAULT INDICATION AFTER BLOCK IN. RESTART NORMAL. PERFORMED APU BITE IAW AMM 49-61-05, NO FAULTS INDICATED. PERFORMED START IAW AMM 49-11-00.SDR UIEA2017052000824Warning Message · false activationDURING CLIMB OUT, THE FWD EQUIPMENT OVERHEAT EICAS MESSAGE ACTIVATED. COMPLETED QRH, MESSAGE DID NOT ILLUMINATE AGAIN. RETURNED EQUIPMENT COOLING SWITCH TO AUTO AND COMPLIED WITH SYSTEM OPS CHECK IAW AMM 21-58-00, NO FAULTS INDICATED.SDR UIEA2017051600796Shutoff Valve · faultedRIGHT ENGINE IDG OUT TEMP MAINTENANCE MESSAGE. PERFORMED FIM 24-20 FAULT TREE 807, FOUND IDG AIR/OIL COOLER VALVE TO BE FAULTY, REMOVED AND REPLACED AIR/OIL HEAT EXCHANGER AIR SHUTOFF VALVE IAW AMM 24-11-07. OPS CHECKED NORMALSDR UIEA2017051500790Control Valve · malfunctionedMESSAGE FOR THE LT PACK BITE. REMOVED AND REPLACED THE LT PACK TEMP CONTROL VALVE IAW AMM 21-51-12. OPS CHECKED NORMAL.SDR UIEA2017051500788Connector · disconnectedLEFT ROW 4-9 EMERGENCY LIGHT INOPERATIVE. INSTALLED THE CONNECTORS IAW AMM 33-51-10. OPS CHECKED NORMAL.SDR UIEA2017051500787Lamp · inoperativeRIGHT UPPER CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-05.SDR UIEA2017051500785Spring · missingAPU SURGE VALVE FILTER ELEMENT SPRING MISSING. INSTALLED THE SPRING IAW AMM 49-53-06.SDR UIEA2017051500783Isolation Valve · inoperativeRIGHT ISOLATION VALVE INOPERATIVE. REMOVED AND REPLACED THE ISOLATION VALVE. OPS CHECKED NORMAL, NO LEAKS IAW AMM 36-11-04.SDR UIEA2017051500781Idg · failedMESSAGE FOR THE IDG OUT TEMP RT ENG. REMOVED AND REPLACED THE IDG IAW AMM 24-11-01. OPS CHECKED NORMAL.SDR UIEA2017050900764Isolation Valve · failedRIGHT ISOLATION VALVE FAILED. R&R RT ISOLATION VALVE, OPS CHECK NORMAL, NO LEAKS IAW AMM 36-11-04.SDR UIEA2017050900762Warning Message · false activationMAINTENANCE MESSAGE FOR RT IDG OUT TEMP. CHECKED SERVICING OF IDG IAW AMM 12-12-03. CHECKED GOOD. CLEARED MAINTENANCE MESSAGE, NO FILTER BYPASS BUTTON POPPED.SDR UIEA2017042300624Rivet · looseDURING PRE-FLIGHT, MULTIPLE ENGINE COWL RIVETS LOOSE IN THE NR 1 ENGINE. REMOVED AND REPLACED THE RIVETS IAW SRM 51-40-02-0G-0, AND CMM 71-11-16, FIG 1. LT NOSE COWL RIVETS SMOOTH AND SECURE ACFT RELEASE TO CONTINUE SERVICE.SDR UIEA2017042000613Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT THE RT EMERGENCY ESCAPE HATCH AND AT SEAT 1J. REMOVED AND REPLACED EMERGENCY LIGHT ASSY IAW AMM 33-51-05, OPS CHECKED GOOD.
Back to Boeing 767-38E