Boeing 767-38E
Service difficulty reports · 1,058
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76738E' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76738E' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2014062700287Light · brokenFLOOR EMER ESCAPE PATHWAY PRX LIGHT ASSEMBLY IS BROKEN AT 37J, THE LENS IS ALSO MISSING. REMOVED & INSTALLED NEW LIGHT ASSEMBLY & COVER. RELAMPED EMER TRACK LIGHTS. OPERATIONS TESTED GOOD IAW AMM 33-51-10.SDR UIEA2014062700286Clamp · brokenV BAND COUPLING BETWEEN NR 1 ENG START VLV & STARTER BROKE. R & R V BAND CLAMP ON NR 1 ENG START VLV IAW AMM 80-11-02.SDR UIEA2014062700285Detector · bentLOW FLOW DETECTOR TS 104 FWD CARGO BENEATH FLOOR, LT SIDE FWD END HAS BENT CONNECTOR. R & R LOW FLOW DETECTOR TS 104 FOR THE FWD RACK & EQUIPMENT COOLING IAW AMM 21-58-17.SDR UIEA2014062700284Clamp · deterioratedRIGHT PACK AREA TUBING CLAMP IS DETERIORATED. REPLACED RT PACK AREA DETERIORATED TUBING CLAMP IAW SRM 51-40-02.SDR UIEA2014062700283Regulator Valve · defectiveENGINE 1 PRV MANUAL LOCK OUT WITH WRENCH HAS EXCESSIVE PLAY. R & R NR 1 ENG PRESS REGULATING VLV IAW AMM 36-11-18, LEAK CHECKED GOOD.SDR UIEA2014062700282Shutoff Valve · defectiveLEFT ENG HPSOV WILL NOT CLOSE, STICKS WEAK RETURN SPRING. R & R NR 1 ENG HPSOV IAW AMM 36-11-07, OPERATIONS & LEAK CHECKED GOOD.SDR UIEA2014062700281Tube · damagedENG 2 TURBINE CASE COOLING HIGH PRESS AIR SUPPLY TUBE DENTED. R & R NR 2 ENG TURBINE CASE COOLING HIGH PRESS AIR SUPPLY TUBE IAW AMM 70-00-00.SDR UIEA2014062700280Wire · damagedMULTIPLE AREAS OF EMER PATHWAY LIGHTING WIRES DAMAGES. REPAIRED EMER FLOOR PATH LIGHTING IN ACFT CABIN AREA AS REQUIRED IAW AMM 33-51-00 & SWPM 20-10-13. PERFORMED SATISFACTORY OPERATIONS TEST IAW AMM 33-51-07-612-035.SDR UIEA2014062700279Duct · out of positionLEFT WING BLEED AIR DUCT IN LE JUST INBD OF NR 1 ENG IS LEAKING AT CLAMP. REPOSITIONED DUCT & ADJUSTED CLAMPS IAW AMM 36-11-01, NO LEAKS.SDR UIEA2014062700278Coupling · defectiveLEFT ENG HPSOV FWD CLAMP NUT HAS NO RUN ON TORQUE. R & R COUPLING ON HPSOV NR 1 ENG FWD LOCATION IAW AMM 36-11-07 PAR E 11 A - E, LEAK CHECKED GOOD.SDR UIEA2014062700277Light · missingEMERGENCY FLOOR PATH LIGHTING AT ROW 1C & 40J MISSING LIGHT ASSEMBLY & COVER. INSTALLED LIGHT ASSEMBLY & COVER AT SEATS 1C & 40J FOR EMER PATH LIGHTING IAW AMM 33-51-10. OPERATIONS CHECKED GOOD.SDR UIEA2014062700276Light · unsecureFLOOR EMER ESCAPE PATHWAY LIGHTING FLOOR TRACK IS LIFTING & PULLED FROM FLOOR 28J & 40J LOG BOOK PG 598850 M2. SECURED PATHWAY LIGHTING TRACK TO FLOOR PANEL AT SEAT AREAS 28J & 40J IAW AMM 25-27-09 ITEM M2 OF LOG BOOK PAGE 598850 CLEARED.SDR UIEA2014062700275Battery · defectiveEMERGENCY LIGHTING BATTERY M737 STATION 988 LT SIDE & M1209 STATION 916 RT SIDE WILL NOT HOLD A CHARGE. R & R EMER LIGHTING BATTERY M737 STATION 988 LT & M1209 STATION 916 RT IAW AMM 33-51-07-022-001. PERFORMED SATISFACTORY BATTERY PACK CAPACITY TEST IAW AMMSDR UIEA2014062700274Smoke Barrier · missingAFT CARGO COMPARTMENT FWD LT WALL LOWER SMOKE BARRIER MISSING. REMOVED FLOORBOARD & CARGO TAPE. REATTACHED SMOKE BARRIER & REINSTALLED CARGO TAPE FT CARGO COMP FWD WALL LOWER LT & INSTALLED FLOOR PANEL IAW AMM 20-11-00, 25-52-01 & SOPM 20-50-12.SDR UIEA2014062700273Hook And Loop · missingAFT CARGO COMP FWD CTR LT WALL BOTTOM VELCRO WORN, MISSING IN AREAS DISBONDED. REPLACED ALL WORN VELCRO & REGLUED DISBONDED AREA IAW SOPM 20-50-12.SDR UIEA2014062700272Hook And Loop · debondedAFT CARGO COMP FWD RT WALL LOWER SMOKE BARRIER VELCRO WORN & DISBONDING. REMOVED FLOORBOARD & REATTACHED LOWER SMOKE BARRIER & VELCRO. REINSTALLED FLOORBOARD IN AFT CARGO COMP FWD RT ALL IAW AMM 20-11-00 & 25-52-01 SOPM 20-50-12.SDR UIEA2014062700271Stud · brokenTWO BROKEN STUDS IN ANCHOR NUTS IN FLANGE THAT MOUNTS APU AIR INTAKE TO FUSELAGE LOWER ROW. R & R TWO ANCHOR NUTPLATES CONTAINING BROKEN STUDS AT APU AIR INTAKE TO FUSELAGE LOWER ROW ATTACHMENT IAW SRM 51-40-02.SDR UIEA2014062700269Skin · puncturedPUNCTURE IN FUSELAGE SKIN AT STATION 699 LT JUST BELOW STRINGER 24L. REPAIRED PUNCTURE IN FUSELAGE SKIN AT STATION 699 LT JUST BELOW STRINGER 24L IAW SRM 53-00-01 FIG 201.SDR UIEA2014062700268Bushing · wornNUMBER 1 ENG PRE COOLER LINK SUPPORT ASSEMBLY RACEWAY & BUSHING WORN. REPLACED NR 1 ENG PRE COOLER LINK SUPPORT ASSEMBLY RACEWAY & BUSHING IAW AMM 36-11-15.SDR UIEA2014062700267Socket · brokenEMERGENCY LIGHTING STRIP HAS WIRES PULLED FREE FROM CTR SEATING AT ROW 19. REPLACED BROKEN SOCKETS IAW SWMP 20-64-17. REFORMED OPERATIONS CHECK GOOD IAW AMM 33-51-00-715-200.SDR UIEA2014062700266Latch · wornRT SLIDE COMPARTMENT DOOR LATCH NR 3 IS WORN. REPLACED RT SLIDE COMPARTMENT DOOR LATCH NR 3 IAW AMM 25-65-09.SDR UIEA2014072700265Track · brokenFLOOR EMER ESCAPE PATHWAY FLOOR TRACK IS BROKEN AT 1J, 8J, 17J, 40J, 5A, 7A, 8A, 9A, 17A & 22A, REPLACEMENT REQUIRED CANNOT BE REPAIRED. R & R EMER ESCAPE PATHWAY FLOOR TRACK IAW B767-300 AMM 25-27- 09. )SDR UIEA2014072700264Arm · brokenLEFT SLIDE SIDE COMPARTMENT DISCONNECT HOUSING ARM IS BROKEN. R & R LT SLIDE COMPARTMENT DISCONNECT HOUSING ARM IAW AMM 25-65-04.SDR UIEA2014062700260O-Ring · damagedAPU SHROUD DRAIN LINE FAILED SYS LEAK TEST IAW AMM 28-25-00. PRESS DECREASES MORE THAN 0.1 PSIG FOR 5 MIN. R & R O RING FROM CONNECTION IN FWD COMPARTMENT OF OFF WING ESCAPE SLIDE BOTTLE IAW AMM 20-10-19. PERFORMED APU SHROUD DRAIN LEAK TEST. LEAK TESTED GSDR UIEA2014062700259Control Valve · faultySTEP E 1 F FAILED OF THE CARGO FIRE EXIT ARMED SWITCHES ROUTINE CARD FWD CARGO HEAT MX MSG FAILED TO SHOW THE LOWER EICAS DISPLAY. REMOVED & INSTALLED NEW FWD CARGO HEAT CONTROL VLV IAW AMM 21-43-00-705-047-003.SDR UIEA2014062700258Precooler · damagedNUMBER 1 ENG PRE COOLER HAS BENT FINS & MISSING FINS ON OTBD SIDE. R & R NR 1 ENG PRE COOLER IAW AMM 36-11-15.SDR UIEA2014062700257Precooler · damagedNUMBER 2 ENG PRE COOLER HAS BENT FINS & IS CLOGGED ON THE INBD SIDE. R & R NR 2 ENG PRE COOLER IAW AMM 36-11-15. OPERATIONS & LEAK CHECKED GOOD.SDR UIEA2014062700256Door · dirtyAFT GALLEY RT WASTE LID WILL NOT CLOSE. CLEANED AFT GALLEY RT WASTE LID SO IT CLOSES PROPERLY AMM 25-00-00.SDR UIEA2014062700255Spring · defectiveR2 DOOR GAS SPRING FOR SLIDE DEPLOY BAR ON RT FWD DOOR WON`T HOLD THE BAR UP. R & R R2 GAS SPRING IAW AMM 25-66 -03.SDR UIEA2014062700254Spring · defectiveR1 DOOR GAS SPRING FOR SLIDE DEPLOY BAR ON RT FWD DOOR WON’T HOLD BAR UP. R & R GAS SPRING FOR SLIDE DEPLOY BAR ON RT FWD DOOR IAW AMM 25-66 -03.SDR UIEA2014062700253Fire Loop · brokenLEFT MLG WW FIRE LOOP IS BROKEN. R & R RIVET ON LT MLG WW LOOP IAW SRM 51-40-02.SDR CA140502003Autopilot Sys · failed(CAN) SHORTLY AFTER TAKEOFF, FLIGHT CREW UNABLE TO ENGAGE AUTO-PILOT. FLIGHT HAD DEPARTED WITH 1 INOPERATIVE ON MEL, BUT APPARENT FAILURE OF ALL 3 OCCURRED. WORKED WITH MOC FOR POSSIBLE RE-SETS, BUT UNABLE. RETURNING TO STATION, AND IS EXPECTED TO LAND APPROXSDR UIEA2014041600150Connector · looseRIGHT ENG ANTI-ICE VLV LIGHT INOPERATIVE. FOUND RT ENG ANTI- ICE VLV LIGHT BULBS GOOD. FOUND WIRING CONNECTOR LOOSE ON BACK OF LIGHT & BUTTON ASSEMBLY, SECURED WIRE. OPERATIONS CHECKED IAW AMM 30-21-03.SDR UIEA2014041100144Engine · defectiveNR 2 ENG FAILED BORESCOPE IAW JOB CARD A-72-307-C1-2. R & R NR 2 ENG.SDR UIEA2014040100136Shutoff Valve · failedSTATUS MESSAGE ILLUMINATED ON RT IDG VALVE . REPLACED IDG AIR OIL HEAT EXCHANGER AIR SHUTOFF VALVE IAW AMM 24-11-07.SDR UIEA2014033100135Fan · vibrationFWD EQUIPMENT COOLING FAN VIBRATING CAN BE HEARD FROM SEAT 1C. R & R FWD EQUIP COOLING FAN, OPERATIONS CHECKED NORMAL.SDR UIEA2014032500127Light · inoperativeRT ENG ANTI-ICE VLV LIGHT INOPERATIVE. PLACED ON MEL DDG 30-21-02-01A, VLV OPERATIONS VERIFIED, MDDR 47124.SDR UIEA2014032200126Light · defectiveFLIGHT DECK EMERGENCY EXIT, PORTABLE, LIGHT BATTERY IS DISCHARGED & WILL NOT RECHARGE. REPLACED & TESTED OK IAW AMM 33-51-01 207 & 208 OFF SN NSN & PN 10-0067-9.SDR UIEA2014032200125Valve · leakingLT ENG DRAIN MAST DRIPPING FUEL, FOLLOWED LINE TO TCC VLV. R & R LPTCC VLV IAW AMM 75-24-01 206. COMPLIED WITH TEST 12, EEC, ECU ACTUATORS IAW AMM 71-00-00 PP 593, NO LEAKS, LPTCCV FULL TRAVEL OBSERVED.SDR UIEA2014030400094Fire Loop · contaminatedPRIOR TO DEPARTURE RT ENG FIRE LOOP 2 STATUS MESSAGE DISPLAYED. OIL CONTAMINATION FOUND AT FWD LOWER FIRE LOOP AREA, CLEANED & INSPECTED. FIRE TEST CARRIED OUT IAW AMM 26-11-01, TEST SATISFACTORY, MDDR 46629 CLOSED.SDR UIEA2014022500085Control Panel · defectiveEICAS MESSAGE FUEL QTY BITE MESSAGE. REPLACED FUEL QTY LOAD SELECT CONTROL PANEL IAW AMM 28-21-13 401. TESTED IAW AMM 28-21-13 EDSD MX PRACTICES OBSERVED IAW AMM 20-41-01 201.SDR UIEA2014022400084Lens · missingEMERGENCY LIGHTING FLOOR PROXIMITY LIGHTING, LIGHT LENS IS MISSING, RT SIDE FWD OVERWING ESCAPE DOOR. INSTALLED A SERVICEABLE LENS & LAMP COVER IAW AMM 33-51-10, OPERATIONS CHECKED OK.SDR UIEA2014021700070Indication Sys · malfunctionedLEFT & RT PIMU MAINT MESSAGE. ACCOMPLISHED FIM71-01 FAULT TREE 810 CLEARED FAULT 155.15 A/B T25 SENSE DISAGREE & RT PIMU FAULT 352-15 A/B T25SENSOR DISAGREE FAULT ISOL PERFORMED, PIMU GND TEST IAW AMM 77-35-00 201NO FAULTS PRESENT OR RECORDED.SDR UIEA2014021300057Light · inoperativeR1 & L2 EXTERIOR EMERGENCY EXIT LIGHTS INOPERATIVE. RELAMPED, TESTED EXTERIOR EMERGENCY LIGHTING AT R1 & L2, PASSED IAW AMM 33-51-06 201.SDR UIEA2014020600045Control Valve · faultyLEFT PACK INOPERATIVE. R & R LT PACK CONTROL VLV IAW AMM 21-51-01 401. OPERATIONS CHECKED OK. PN OFF 396462, SN OFF 7100.SDR UIEA2014020600044Unknown · malfunctionedLEFT PACK INOPERATIVE LIGHT ON IN AUTO. PERFORMED BITE TEST ON PACK CONTROLLER PE AMM 21-25-00 NO FAULTS. MANUALLY CYCLED PACK CONTROL VLV OPERATIONS CHECKED NORMAL.SDR UIEA2014011800014Control Valve · defectiveRIGHT PACK TEMP CONTROL INOPERATIVE AUTO, STBY OK. R & R RT PACK TEMP CONTROL VLV IAW AMM 21-51-12. OPERATIONS & LEAK CHECKED GOOD.SDR UIEA2014010700002Oxygen Bottle · unserviceablePORTABLE OXYGEN BOTTLE AT POSITION R4 UPPER READS 1600 PSI. R & R O2 BOTTLE IAW AMM 25-31-01.SDR UIEA2013123000619Control Valve · leakingHMG CONTROL VLV LEAKING. R & R HMG CONTROL SHUT OFF VLV IAW AMM 24-25-03.SDR UIEA2013122700617Inverter · faultySTATUS MESSAGE STANDBY INVERTER DISPLAY. R & R STATIC INVERTER IAW AMM 24-33-05 TESTED OK.
Back to Boeing 767-38E