Boeing 767-3JHF
Service difficulty reports · 709
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673JHF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673JHF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2013030600117Control Unit · inoperativeLT SIDE WINDOW HEAT INOPERATIVE. R & R LEFT WHCU M192 IAW AMM 30-41-01. OPS CHECKED GOOD ON GROUND.SDR UIEA2013030100108Bleed Air Sys · inoperativeAPU BLEED AIR INOPERATIVE. RESTARTED APU, BLEED AIR OPS CHECK OK IAW AMM 49-11-00.SDR UIEA2013021900092Engine · making metalFOUND METAL CHIPS IN TAIL PIPE OF NR 1 ENGINE. R & R NR 1 ENGINE IAW AMM 71-00-00 ENG RUN & LEAK CHECKS SATISFACTORY.SDR UIEA2013021500088Relay · malfunctionedLEFT ENGINE FUEL VALVE LIGHT ILLUMINATED IN CRUISE. REPLACED LT ENGINE FUEL & IGNITION K1251 CONTROL RELAY IAW AMM 76-11-00, SYS OPS CHECKED NORMAL ON GROUND.SDR UIEA2013021400080Warning Light · illuminatedLEFT ENG FUEL VALVE EICAS ILLUMINATED ON CLIMB AT APPX 11,000 FT. REMAINED ON DURATION OF FLIGHT, ENGINE OPS NORMAL. PERFORMED TROUBLESHOOTING IAW FIM 76-11-812, NO FAULTS NOTED, COULD NOT DUPLICATE ON GROUND. SWAPPED M8/M9 DIMMER; PC CARDS IN P-29 PANEL FORSDR UIEA2013021200078Control Unit · malfunctionedLT ENG VALVE LIGHT ILLUMINATED APPROX 40 MIN DURING FLIGHT. NO EICAS MESSAGE(REPLACED LT ENG VALVE LIGHT DRIVER W/NEW UNIT IAW AMM 33-16-01, SYS OPS CK GOOD PN 434-093-001)SDR UIEA2013021000077Charger · inoperativeCREW REPORT "MAIN BAT CHARGER" STATUS MESSAGE. (REF: TROUBLESHOT IAW FAULT ISOLATION MANUAL 24-31, STATUS MSG CLEARED. OPS CHECK GOOD.)SDR UIEA2013013100046Indicator · intermittentSTANBY ENGINE INDICATION INTERMITTENT. REMOVED AND INSTALLED STANBY ENGINE INDICATOR IAW AMM 77-41-01, OPS CHECKED GOOD.SDR UIEA2013013000038Indicator · false indicationLEFT ENGINE OIL QTY DROPPED TO 7 AT 4+30 IN FLT, RECOVERED TO 10 OVER NEXT 2 HRS AC BLOCK IN 20 AT FLT TERMINATION. EICAS INDICATION AT BLOCK IN READS 19QTS CAP CHECK OIL INDICATION SHOWS FULL ADDED 1QT, IAW AMM 79-31-00 C/W ENGINE, INSPECTION FOR OIL LEAKAG
Back to Boeing 767-3JHF