Boeing 767-432ER
Service difficulty reports · 3,098
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2021031801549Power Supply · inoperativeSHIP 1820 BATTERY SUPPLY M736 IS INOPERATIVE. MAINTENANCE REPLACED BATTERY SUPPLY. SYSTEM OPERATION IS NORMAL. (LP 1757157)SDR DALA2021031801546Failsafe · crackedSHIP 1820 - DURING UT INSPECITON MAINTENANCE FOUND RH STA 955 FAIL-SAFE STRAP FOUND CRACK INDICATION. FAIL SAFE STRAP REPAIRED. (LP 175186)SDR DALA2021031801545Floor Support · corrodedSHIP 1820 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 PAX CABIN FLOOR STRUCTURE CORROSION AT STA 325 LBL55. REPAIRED PER ERA 590091-14. (LP 175183)SDR DALA2021031801544Seat Track · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SEAT TRACK AT RBL 88.5 STA1219 TO STA 1417. C/W ERA 589988-14. (LP 1756355)SDR DALA2021031801543Failsafe · crackedSHIP 1820 - DURING OPEN HOLE INSEPCTION MAINTENANCE FOUND CRACK INDICAITONS ON THE LOWER OF THE THREE FASTENERS HOLES ON THE LH STA955 FAIL-SAFE STRAP. DAMAGED AREA REPAIRED (LP 1756366)SDR DALA2021031801542Failsafe · crackedSHIP 1820 OPEN HOLE INSPECTION FOUND CRACK INDICATION ON THE FAIL-SAFE STRAP AT THE LOWER OF THE THREE FASTENER HOLES COMMON TO THE LH STA955 FAIL-SAFE STRAP AND T FITTING. DAMAGED HOLE ON FITTING REPAIRED. (LP 1756352)SDR DALA2021031801541Failsafe · crackedSHIP 1820 - DURING INSPECTION MAINTENANCE FOUND LH STA955 FAIL-SAFE STRAP WITH CRACK INDICATION. FAIL SAFE STRAP REPAIRED. (LP 1756346)SDR DALA2021031801540Failsafe · crackedSHIP 1820 DURING OPEN HOLE HFEC INSPECTION MAINTENANCE FOUND CRACK INDICATION ON THE LOWER OF THE THREE FASTENER HOLES ON THE RH STA955 FAIL-SAFE STRAP. DAMAGED HOLES WERE REPAIRED. (LP 1756288)SDR DALA2021031801539Structure · wornSHIP 1821 DURING INSPECTION MAINTENANCE FOUND R/H WING #9 SLAT O/B UPPER CORNER FOUND WORN. SLAT REPAIRED PER SRM 51-70-10. (LP 1756195)SDR DALA2021031801538Structure · wornDURING INSPECTION MAINTENANCE FOUND R/H WING #10 SLAT I/B UPPER CORNER FOUND WORN. REPAIRED PER SRM 51-70-10. (LP 1756188)SDR DALA2021031601484Tee Fitting · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION ON "T" FITTING. FITTING REPLACED. (LP 1756344)SDR DALA2021031801537Stiffener · crackedDURING INSPECTION MAINTENANCE FOUND CRACK ON RH NOSE WHEEL VERTICAL STIFFNER FILLET RADIUS AT WL172 APPROX 1 INCH LONG REPAIRED ON WORK CARD 5312-01186-02B, (LP 1755420)SDR DALA2021031801536Stiffener · crackedDURING INSPECTION MAINTENANCE FOUND 01EA CRACK ON NOSE WHEEL LH VERTICAL STIFFENER FILLET RADIUS AT WL172 APPROX 1 INCH LONG. CRACKED AREA REPAIRED. (LP 1755419)SDR DALA2021031601485Sign · inoperativeSHIP 1802 CREW REST FORWARD EMERGENCY EXIT LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE EXIT SIGN ASSEMBLY. SYSTEM OPERATION IS NORMAL. (LP 7427077)SDR DALA2021031601483Fairing · dentedDURING INSPECTION MAINTENANCE FOUND NO.2 PYLON UPPER FWD FAIRING (441AT) FOUND DENT FROM L /E 44.2 INCH CROSS O/B EDGE 14 INCH AND REPAIRED PER SRM 54-55-70 AND 51-70-17. (LP 1753781)SDR DALA2021031601482Fairing · erodedDURING INSPECITON MAINTENANCE FOUND EROSION ON NO.2 PYLON AFT FAIRING O/B ACCESS DOOR L/E AREA AND REPAIRED PER SRM 51-70-04. (LP 1753705)SDR DALA2021031601481Fairing · erodedDURING INSPECTION MAINTENANCE FOUND EROSION NO.2 PYLON AFT FAIRING I/B ACCESS DOOR L/E AREA AND REPAIRED PER SRM 51-70-04. (LP 1753700)SDR DALA2021031601480Frame · crackedDURING INSPECITON MAINTENANCE FOUND 1 EA CRACK OF THE FWD OUTER CHORD (INTERNAL) AT STRINGER 7R BULKHEAD AT STA1809. S-7R. FRAME FWD OUTER CHORD. 01EA 5MM( 0.1968") CRACK REPAIRED PER SRM 53-80-08. (LP 1752898)SDR DALA2021031601479Stringer · crackedDURING INSPECTION MAINTENANCE FOUND 1 EA CRACK ON THE S-13AR STA 1662 ABOUT 0.5 INCH LONG AND REPAIRED PER SRM 53-80-04. (LP 1752719)SDR DALA2021031101381Seat Track · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SEAT TRACK AT LBL88.5 STA 1362 TO 1480. SEAT TRACK REPLACED. (LP 1750909)SDR DALA2021030901352Floorbeam · crackedDURING INSPECTION AFT CARGO COMPARTMENT STA 1109 FLOOR PANEL SUPPORT BEAM CRACK AT LBL 26 AND RBL 26. REPLACED FLOOR SUPPORT. (LP 1749250)SDR DALA2021030801330Warning Light · false activationSHIP 1807 ON TAKE OFF, HAD AVER BRIEF RIGHT FORWARD ENTRY DOOR MESSAGE, THAN OFF FOR DURATION OF FLIGHT. SYSTEM RESTORED ITSELF. AS A PRECAUTION CLEANED DOOR SENSOR AT R1 DOOR. SYSTEM OPERATION IS NORMAL. (LP 7573712)SDR DALA2021030901350Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND PASSENGER CABIN FLOOR STRUCTURE CORROSION AT STA 246 LBL13. REPAIRED PER SRM. (LP 1749166)SDR DALA2021030501283Wire · looseSHIP 1815 EMERGENCY ARM SWITCH LIGHTS INTERNAL SPRING WIRE LOOSE. MAINTENANCE FOUND EMERGENCY LIGHTS SWITCH GUARD OPERATES NORMAL. SYSTEM OPERATION IS NORMAL. (LP 7288015)SDR DALA2021030501281Failsafe · crackedDURING INSPECTION MAINTENANCE FOUND CRACK INDICATION ON RH STA955 FAIL-SAFE STRAP AND REPAIRED. (LP 1746616)SDR DALA2021030501280Failsafe · crackedDURING INSPECTION MAINTENANCE FOUND CRACK INDICATION ON LH STA955 FAIL-SAFE STRAP. CRACKED REPAIRED. (LP 1746613)SDR DALA2021030501279Tee Fitting · damagedDURING INSPECTION MAINTENANCE FOUND T FITTING WITH 1 EA HOLE DAMAGED. FITTING REPLACED. (LP 1746607)SDR DALA2021030501278Closeout Panel · corrodedDURING INSPECTION SEVERE CORROSION WAS FOUND ON LH MAIN LANDING GEAR WEB CLOSURE PANEL AT FS957 AND LBL88.5. REPAIRED PER ERA 534278-14. (LP 1746604)SDR DALA2021030501277Seat Track · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SEAT TRACK AT RBL54.75 STA1362 TO STA1480. SEAT TRACK REPAIRED PER SRM 53-00-52. (LP 1746599)SDR DALA2021030901349Floorbeam · corrodedDURING INITIAL CORROSION LEVEL 2 FOUND PASSENGER CABIN FLOOR STRUCTURE CORROSION AT STA1480 LBL41 TO LBL53. REPAIRED PER ERA 529123-14. (LP 1749097)SDR DALA2021030101155Shear Tie · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SHEAR TIE AT STA368 AND S-36L TO S-37L FWD CARGO COMPARTMENT. SHEAR TIE WAS REPLACED. (LP 1742902)SDR DALA2021030101161Battery Pack · inoperativeSHIP 1819 DURING SERVICE CHECK MAINTENANCE FOUND EMERGENCY LIGHTS AT SEATS 50FG-56FG ARE INOPERATIVE. THE BATTERY AND CHARGER WERE REPLACED. SYSTEM OPERATION IS NORMAL. (LP 5369963)SDR DALA2021031101384Seat Track · corrodedMAINTENANCE FOUND CORROSION LEVEL 2 ON CABIN SEAT TRACK AT STA 368 RBL AND REMOVED. (LP 1741576)SDR DALA2021031101383Floor Support · corrodedDURINING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON CABIN FLOOR STRUCTURE AT STA 1350 TO 1562 RBL 83. T-CHORD REPAIRED. (LP 1741566)SDR DALA2021031101382Seat Track · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON CABIN SEAT TRACK AROUND STA 368 LBL AND REMOVED. (LP 1741570)SDR DALA2021030101159Sign · misinstalledSHIP 1813 MAINTENANCE FOUND LLCR EXIT SIGN NOT INSTALLED PER MOD PAPER WORK SPECIFICATIONS. CORRECTIVE ACTION: REPLACED EMERGENCY LIGHT SIGN ASSEMBLY UNDER THE STAIRS. SYSTEM OPERATION IS NORMAL. (LP 7621254)SDR DALA2021030101158Sign · inoperativeSHIP 1813 MAINTENANCE FOUND EXIT SIGN ON AFT LOWER CREST WALL INOPERATIVE AND REPLACED SIGN ASSEMBLY. (LP 7621253)SDR DALA2021030101153Panel · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON AROUND STA 324, LBL 55 CABIN FLOOR STRUCTURE. THE CORROSION REMOVED AND CUT THE DAMAGED SECTION CHORD. (LP 1741583)SDR DALA2021030101152Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON CABIN FLOOR BEAM AROUND STA 303, LBL 48. THE CORROSION REMOVED AND CUT THE DAMAGE SECTION CHORD. (LP 1741579)SDR DALA2021030101160Sign · inoperativeSHIP 1815 EMERGENCY LIGHT R2 AFT DOOR INOPERATIVE. MAINTENANCE REPLACED THE PASSENGER EXIT SIGN ASSEMBLY. (LP 7595476)SDR DALA2021030901351Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 PASSENGER CABIN FLOOR STRUCTURE CORROSION AT STA 325 RBL22-RBL55.SDR DALA2021030101162Indicator · inoperativeSHIP 1810 L2 DOOR SLIDE INDICATOR INOPERATIVE. MAINTENANCE REPLACED L2 DOOR SLIDE ARM LIGHT ASSEMBLY. (LP 1740165)SDR DALA2021022501110Switch · abnormalL2 DOOR SLIDE DOES NOT ILLUMINATE WITH DOORS ARMED. MAINTENANCE FOUND BASE OF SLIDE LIGHT SWITCH OFF AND REINSTALLED BASE. SYSTEM OPERATION IS NORMAL. (LP 1739035)SDR DALA2021022201022Door · out of sequenceFLIGHT ATTENDANT HAD DIFFICULTY CLOSING AND ARMING L@ DOOR. MAINTENANCE FOUND DOOR OUT OF SEQUENCE AND RESET. SYSTEM OPERATION IS NORMAL.SDR DALA2021030101154Shear Tie · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SHEER TIE AT AT STA 1197+ 154 AND S-38R AND REPLACED SHEER TIE. (LP 1742880)SDR DALA2021030101149Skin · damagedMAINTENANCE FOUND EVIDENCE OF SEVERAL LIGHTNING STRIKES NEAR FWD CARGO DOOR. REPAIRED PER SRM 53-00-01. (LP 1731856)SDR DALA2021021600871Battery Pack · inoperativeSHIP 1814 LLCR EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED LLCR BATTERY PACK. SYSTEM OPERATION IS NORMAL. (LP 7604909)SDR DALA2021020800714Battery Pack · inoperativeDURING EMERGENCY LIGHTING LOWER LEVEL CREW REST INSPECTION MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL. (LP 9397499)SDR DALA2021020300657Connector · unsecureSHIP 1816 CEILING EMERGENCY LIGHTS ABOVE SEAT 43FG ARE INOPERATIVE. MAINTENANCE SECURED CANNON PLUG ON THE LIGHT ASSEMBLY L3300. SYSTEM OPERATION IS NORMAL. (LP 7486741)SDR DALA2021020300658Fuse · blownMAINTENANCE FOUND R4 DOOR EXTERNAL EMERGENCY LIGHTS INOPERATIVE. FUSE IN POWER SUPPLY M0734 WAS REPLACED. SYSTEM OPERATION IS NORMAL. (LP 6225956)
Back to Boeing 767-432ER