Boeing 767-432ER
Service difficulty reports · 3,098
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019041502446Skin · punctured#7 SPOILER LOWER SKIN HAS A PUNCTURE, REPAIRED PER SRM 51-70-17.SDR DALA2019040502213Rib · damagedLH ELEVATOR LE RIB AT ELEVATOR STA 192.7 FOUND DAMAGE. REPAIRED PER SRM 55-20-02. (LP 1017418)SDR DALA2019040502215Structure · damagedRIGHT INBOARD SIDE OF #1 ENG THRUST REVERSER WIRE MESH CLOTH DAMAGE 12 " X 9 " C/W E/RA 569315-14. (LP 5553050)SDR DALA2019040502214Screw · looseL1 SLIDE LIGHT BLINKING ON/OFF. FOUND RING TERMINAL SCREW 2 LOOSE ON SLIDE WARNING LIGHT M1328. SECURED RING. SYSTEM OPERATION IS NORMAL.SDR DALA2019040402212Battery Pack · inoperativeEXIT LIGHTS BY 4L DOOR INOPERATIVE. REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2019040432188Connector · looseEMERGENCY LIGHTS AT 21-22 AB ARE INOPERATIVE. MAINTENANCE FOUND LOOSE CONNECTOR AT SEAT 20AB AND SECURED CONNECTOR. SYSTEM OPERATION IS NORMAL.SDR DALA2019040202094Skin · damagedRW INBD MAIN FLAP HAS GROOVE WORN INTO COMPOSITE ON UPPER SURFACE AT OUTBD END REPAIRED GOUGE ON RW INBD MAIN FLAP OTBD EDGE USING A VACUUM BAG HEAT BLANKET CURE. REPAIRED PER SRM 57-53-01.SDR DALA2019040432187Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK INOPERATIVE. REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA20190402093Battery Pack · inoperativeEMERGENCY LIGHTS ROW 38-45AB ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY AND CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2019040402190Skin · crackedSKIN STA 1654, S13AR CRACKED. C/W E/RA 567634-14.SDR DALA20190402089Skin · delaminatedR/H WING NO.8 SLAT INTERNAL SURFACE FOUND DELAMINATION FROM O/B EDGE 31.5 INCH. REPAIRED PER SRM 51-70-10. (LP 1007150)SDR DALA2019061103514Outlet · sparksPOWER OUTLET SPARKED WHEN PLUG WAS PULLED OUT OF OUTLET. C/B POPPED AND WAS NOT RESET. ON GALLEY POWER CONTROL PANEL BY 1R DOOR RESET CB - OUTLET CHECKS NORMALSDR DALA2019032702018Web · corrodedNR 2 PYLON UPPER SIDE CLOSEOUT WEB IS CRACKED ON I/B SIDE BY MIDSPAR FITTING. REPLACED WEB. (LP 1002998)SDR DALA2019032902017Splash Guard · corrodedFOUND OUT 01EA SPLASH GUARD OF DOOR LOWER MAIN SILL CORROSION AT STA 246 TO STA 266 RBL 73. THE SPLASH GUARD WAS REPLACED.SDR DALA2019032101956Failsafe · damagedLEFT STA 955 FAIL SAFE DAMAGED AND REPAIRED. (LP 0994880)SDR DALA2019032902013Battery Pack · failedEMERGENCY LIGHTS BATTERY PACK M736 FAILED CAPACITY CHECK. MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2019032101963Angle · crackedNR 2 PYLON STRUT BOX NAC STA 295. CLOSEOUT ANGLE CRACKED I/B. VIEWED FROM ACCESS 446AR LOOKING I/B & UP AFT. REPLACED ANGLE. (LP 0994198)SDR DALA2019032001951Power Supply · failedFOUND EMERGENCY BATTERY POWER SUPPLY TEST FAILED AT CREW REST. MAINTENANCE REPLACED THE BATTERY POWER SUPPLY ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR DALA2019032001953Battery Pack · dischargedEMERGENCY LIGHTS AT 38-45AB ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2019032001952Connector · disconnectedEMERGENCY LIGHTS ARE INOPERATIVE AT SEAT 19-21FG. MAINTENANCE RECONNECTED C/P AT L3348. SYSTEM OPERATION IS NORMAL.SDR DALA2019031901807Skin · wornLEFT WING NR 3 SLAT INNER UPPER SURFACE FOUND WORN AT LES 710. REPAIRED PER SRM 57-43-02. (LP 0990231)SDR DALA2019032902019Transceiver · faultySHIP 1807 - ATO - DUE TO WIND SHEAR WARNING AT 70 KIAS. CORRECTIVE ACTION: MAINTENANCE C/W NO GO ODI PROCEDURES. WEATHER RADAR TRANSCEIVER DID NOT TEST CORRECTLY AND WAS REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA2019031901812Shear Tie · corrodedCORROSION LEVEL: 2FWD CARGO COMPARTMENT FOUND SHEAR TIE CORROSION AT STA 742, BETWEEN S-39L AND S-39R. REPLACED FWD CARGO COMPARTMENT SHEAR TIE. (LP 0990575)SDR DALA2019031901811Shear Tie · corrodedCORROSION LEVEL: 2-BULK CARGO SHEAR TIE FOUND CORROSION AT STA1417, BETWEEN S-38R AND S-37R. REPLACED SHEAR TIE. (LP 0990567)SDR DALA2019031901810Shear Tie · corrodedCORROSION LEVEL: 2 BULK CARGO SHEAR TIE FOUND CORROSION AT STA1417, BETWEEN S-39L AND S-38. REPLACED SHEAR TIE. (LP 0990559)SDR DALA2019031901809Shear Tie · corrodedCORROSION LEVEL: 2 -BULK CARGO SHEAR TIE FOUND CORROSION AT STA1417, BETWEEN S-39R AND S-38R, OUT OF LIMITS. REPLACED SHEAR TIE. (LP 0990554)SDR DALA2019031901808Shear Tie · corrodedCORROSION LEVEL: 2 BULK CARGO SHEAR TIE FOUND CORROSION AT STA1417, BETWEEN S-38L AND S-37L OUT OF LIMITS. REPLACED SHEAR TIE. (LP 0990542)SDR DALA2019031801806Seal · crackedMTC TASK- LT WING FIXED LEADING EDGE SEAL STRIP FOUND CRACKED AT NR 4 SLAT STOP FITTING AREA. REPAIRED PER ERA 595838-14. (LP 0988388)SDR DALA2019031501739Beam · corrodedCORROSION LEVEL: 2 FOUND OUT STUB BEAM CORROSION ABOVE FUEL TANK STA871 BETWEEN LBL77 AND LBL88. REPAIRED (LP 0986732)SDR DALA2020030901740Intercostal · damagedDURING MIDLIFE VISIT AT STAG, TWO INTERCOSTALS WERE FOUND WITH SEVERAL ELONGATED HOLES BETWEEN STA 654+88 AND 654+110, LBL AND RBL 26. ER/A 576046-14 SECTION I WAS ACCOMPLISHED. FOLLOW ON ACTION IS REQUIRED FOR DTE. ACCOMPLISH ER/A 576046-14 SECTION II BY 08MASDR DALA2019031101733Charger · inoperativeEMERGENCY LIGHTS AT SEAT 15AB-20AB ARE INOPERATIVE. REPLACED EMERGENCY LIGHT POWER SUPPLY CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2019031101740Beam · crackedNR 2 PYLON OUTBD HYD BAY LOWER BEAM IS CRACKED @ FORWARD END C/W EAR 524549-14. (LP 0975491)SDR DALA2019030701632Bulkhead · crackedHFEC INSPECTION FOUND 01 EA CRACK AT STA 1809 BULKHEAD, LEFT HORIZONAL INNER CHORD APPROX 1 INCH LONG REPAIRED PER SRM 53-80-08. (LP 0973400)SDR DALA2019030701631Floorbeam · corrodedCORROSION LEVEL: 2 CABIN FLOORBEAM AT STA 1540 RBL15-RBL40 UPPER FLANGE FOUND CORROSION AND REPAIRED. (LP 0973275)SDR DALA2019031101618Restrictor Valve · faultySHIP 1813 - ATB - RETURNED TO JFKI DUE TO GEAR DISAGREE AND GEAR DOOR EICAS MESSAGES APPEARED AFTER TAKEOFF. COMPLIED WITH CHECKLIST, PUT THE GEAR DOWN AND ALL INDICATORS NORMAL CORRECTIVE ACTION- REPLACED RT MLG RESTRICTOR VALVE AND RT MLG DOOR SAFETY VALVE. SDR DALA2019030601630Connector · disconnectedEMERGENCY LIGHTS AT SEATS 20-21A ARE INOPERATIVE. MAINTENANCE FOUND CONNECTOR DISCONNECTED AT 19A AND RECONNECTED. SYSTEM OPERATION IS NORMAL.SDR DALA2019030501636Skin · damagedFUSELAGE SKIN SCRIBE LINES STA 1351-1373, S-12L - S-14L. REPAIRED C/W 575832-14. (LP 0969469)SDR DALA2019022801353Stiffener · crackedMFEC INSPECTION FOUND 01 EA CRACK AT NOSE WHEEL WELL, LT VERTICAL STIFFENER FILLET RADIUS BETWEEN WL 159.00 TO WL 185.00 APPROX 0.5 INCH. WORK COMPLETED. (LP 09633211)SDR DALA2019022801352Stiffener · crackedMFEC INSPECTION FOUND 01EA CRACK AT NOSE WHEEL WELL, RT VERTICAL STIFFENER FILLET RADIUS BETWEEN WL 159.00 TO WL 185.00 APPROX 0.5 INCH. WORK COMPLETED. (LP 0963061)SDR DALA2019022601314Seat Track · corrodedCORROSION LEVEL: 2 SEAT TRACK-CABIN SEAT TRACK AT STA347 RBL88.5 FOUND CORROSION. REPLACED SEAT TRACK. (LP0959984)SDR DALA2019022651227Sequence Valve · failedSHIP 1813 - ATB - AFTER TAKEOFF WHEN GEAR HANDLE SELECTED UP RECEIVED RIGHT MAIN LANDING GEAR UNSAFE LIGHT, GEAR DISAGREE MESSAGE, AND GEAR DOOR MESSAGE. VIBRATIONS FELT AT SPEEDS UP TO 240 KIAS. CORRECTIVE ACTION - REPLACED MAIN GEAR OPERATED SEQUENCE VALVE ASDR DALA2019032601960Skin · corrodedDURING HCK AT STAG, CORROSION WAS NOTED ON THE CENTER WING TANK UPPER SKIN, STA 871, LBL 86. C/W ERA 57453-14. (LP 0955771)SDR DALA2019022621229Relay · failedSHIP 1805 -FUME- WHILE AT THE GATE, APU WAS ON LINE AND THE RAMP PULLED EXTERNAL POWER. THERE WAS A BURNING ELECTRICAL SMELL IN THE COCKPIT AND FORWARD GALLEY. SEVERAL CB'S TRIPPED IN THE COCKPIT. CORRECTIVE ACTION: INSPECTION OF WIRES/ TERMINAL LUGS OK. R/R KSDR DALA2019022611228Tee Fitting · corrodedCORROSION LEVEL: 2 DETAIL INSP."T" FITTING FOUND LOWER HOLE COROSION. "T" FITTING REPLACED. (LP 0952478)SDR DALA2019022101112Strap · crackedOPEN HOLE HFEC INSPECTION FOUND 01EA CRACK IN THE LOWER OF THE THREE FASTENER HOLES ON THE FAIL-SAFE STRAP. REPAIRED CRACK.SDR DALA2019022101111Strap · crackedSURFACE HFEC INSPECTION FOUND 01EA CRACK APPROXIMATELY .0.55" IN LENGTH AROUND THE LOWER OF THE THREE FASTENER HOLES ON THE FAIL-SAFE STRAP SURFACE. CRACKED REPAIRED.SDR DALA2019022101107Pump · fireFLIGHT 109 - WHILE PASSENGER DEPLANING NEARLY COMPLETED DURING MAINTENANCE POST FLIGHT INSPECTION DISCOVERED THE ADP ON FIRE IN THE LEFT SIDE OF THE FUSELAGE. THE FIRE WAS EXTINGUISHED WITH A PORTABLE FIRE EXTINGUISHER. REPLACED ADP AND RELAY K684. SYSTEM OPERSDR DALA2019022001108Connector · brokenSLIDE INDICATOR LIGHT INOPERATIVE. MAINTENANCE FOUND BROKEN CONNECTOR TO THE SWITCH, CRIMPED BROKEN WIRE AND INSTALLED NEW SWITCH. SYSTEM OPERATION IS NORMAL.SDR DALA2019022001104Light · inoperativeEMERGENCY LIGHT ABOVE COCKPIT DOOR IS INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND BATTERIES. SYSTEM OPERATION IS NORMAL.SDR DALA2019021901060Connector · corrodedL2 AND L3 EXTERIOR EMERGENCY SLIDE LIGHTS ARE INOPERATIVE. CLEANED CORRODED CONNECTIONS AND RE-LAMPED. SYSTEM OPERATION IS NORMAL.
Back to Boeing 767-432ER