Boeing 767-432ER
Service difficulty reports · 3,098
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2017030701887Lens · damagedEMERGENCY EXIT DIFFUSER LENS DAMAGED. INSTALLED A NEW LENS.SDR DALA2017030601837Bulb · missingWHITE EMERGENCY LIGHT BULB AT R1 CLOSET IS MISSING. REPLACED THE BULB.SDR DALA2017030601836Light · damagedLOWER CABIN AISLE EMERGENCY LIGHT ASSY DAMAGED. R & R THE EMERGENCY LIGHT ASSEMBLIES IAW AMM 33-51.SDR DALA2017030601835Lens · missingWHITE EMERGENCY LIGHT LENS MISSING FROM MID LEFT GALLEY, AFT LEFT GALLEY PARTITION AND R1 CLOSET. INSTALLED THE MISSING LENSES IAW AMM 33-51.SDR DALA2017030601834Contact · damagedDURING A SERVICE CHECK, FOUND THE R4 DOOR EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. CONTACT PUSHED BACK, SOLDERED THE CONTACT, OPS NORMAL.SDR DALA2017030201718Cover · looseEMERGENCY EXIT SIGN COVER LOOSE/LOCATIONS:102. FOUND COVER AND REINSTALLED, OK FOR SERVICE.SDR DALA2017030201717Cover · looseEMERGENCY EXIT SIGN COVER LOOSE. FOUND COVER AND REINSTALLED.SDR DALA2017022701600Panel · tornRT ELEVATOR TRIM PANEL FWD TORN. REMOVED AND REPLACED DAMAGED TRIM PANEL IAW AMM 53-54.SDR DALA2017022701604Lens · damagedEMERGENCY LIGHT DIFFUSER LENS DAMAGED. R & R LIGHT ASSY IAW MM 33-51.SDR DALA2017022701603Lens · damagedEMERGENCY LIGHT DIFFUSER LENS DAMAGED. R & R LIGHT ASSY IAW MM 33-51.SDR DALA2017022401602Lens · missingEMERGENCY LIGHT MISSING A RED LENS AT THE R1 DOOR. INSTALLED THE RED LENS.SDR DALA2017022401593Lens · missingFOUND R1 AND L1 RED EMERGENCY LIGHT MISSING. REPLACED THE MISSING LENS.SDR DALA2017022101415Socket · dirtyR2 & L2 EXTERIOR DOOR EMERGENCY SLIDE LIGHTS INOPERATIVE. CLEANED LIGHT SOCKETS OPS NORMAL IAW AMM 33-51.SDR DALA2017021701349Connector · looseEMERGENCY PATH LIGHTS INOP AT SEATS 36FG 37FG. FOUND LOOSE CONNECTION AT 36 FG AND 37 FG. PERFORMED OPS TEST PER AMM 33-51. OPS GOOD. OK FOR SVC.SDR DALA2017021401200Bypass Valve · failedDURING GEAR RETRACTION, BOTH MAIN GEAR FAILED TO FULLY RETRACT. CREW CONSULTED QRH, DECISION WAS MADE TO RETURN TO DEPARTURE AND DUMPED FUEL. EMERGENCY WAS DECLARED. REPLACED THE MLG SELECTOR BYPASS VALVE IAW AMM.SDR DALA2017020801055Skin · crackedNR 2 ENGINE RT CORE COWL SKIN HAS A 10 INCH CRACK AT THE TE. REPLACED THE COWL ASSY IAW AMM 71-11-06.SDR DALA2017020600964Connector · looseDURING EMERGENCY LIGHTS TEST 37FG ISLE LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE. SECURED THE CONNECTOR AND TESTED NORMAL IAW AMM 33-51.SDR DALA2017020200848Lens · looseEMERGENCY EXIT SIGN COVER LOOSE. SECURED LENS COVER.SDR DALA2017020200847Cover · looseEMERGENCY EXIT SIGN COVER LOOSE. ATTACHED THE COVER.SDR DALA2017012700702Web · cracked3 EA 1/4" HOLES HAVE CRACK INDICATIONS IN NR 2 PYLON UPPER WEB NAC 226, LBL 8. INCORPORATED AND C/W PER ERA 554545-14 REV ORIGINAL.SDR DALA2017012700700Web · crackedNR 2 PYLON NAC STA 226, LBL 3, 3/16TH HOLE HAS CRACK INDICATION IN PYLON WEB. INCORPORATED AND C/W PER ERA 554545-14 REV ORIGINAL.SDR DALA2017012700699Web · crackedNR 2 PYLON UPPER WEB: WEB IS CRACKED AT GENERATOR CABLE FEED THROUGH.SDR DALA2017012700698Skin Panel · crackedNR 2 PYLON I/B SKIN PANEL: CRACK AT FASTENER. ALSO, ADJACENT FASTENERS ARE LOOSE. C/W REPAIR PER PRI 554683-14, REV1 AND ERA 554683-14 REV ORIGINAL.SDR DALA2017012600653Line · leakingAIRCRAFT DIVERTED DUE LOSING HYDRAULIC FLUID FROM LEFT HYDRAULIC SYSTEM DOWN TO 43%. FOLLOWED THE QRH. AN EMERGENCY WAS DECLARED. FOUND ENGINE MOUNTED HYD PRESSURE LINE AND FITTING LEAKING. R & R LEFT ENGINE HYD PRESSURE LINE AND VALVE ASSY IAW AMM 29-11.SDR DALA2017012600654Lens · missingEMERGENCY LIGHT LENS MISSING FROM CONTROL PANEL. REPLACED THE LENS IAW AMM 33-51.SDR DALA2017012500610Skin · gougedA TWO INCH GOUGE IN THE SKIN AT BS 1197 +146 BETWEEN STRINGERS 24 AND 25L. BLENDED THE GOUGE PER FIGURE 101 , DETAIL II SRM 53-00-01.SDR DALA2017012300548Web · crackedNR 2 PYLON UPPER WEB CRACKED AT GENERATOR CABLE FEED THROUGH. REPAIR C/W PER ERA 554545-14 REV 0 ON NR 72 AT C CK.SDR DALA2017012300549Unknown · hazeFLIGHT ATTENDANTS REPORTED A LIGHT HAZE IN THE CABIN FROM ROWS 15 TO 22. HAZE PERSISTED FOR ABOUT 20 MINUTES BEFORE GRADUALLY DISSIPATING. ALL AIRCRAFT SYSTEMS APPEARED NORMAL.SDR DALA2017012000546Structure · crackedNR 1 PYLON CRACKED AT CUTOUT FOR GENERATOR FEEDER CABLES. REPAIRED IAW ERA 554502-14 REV 0.SDR DALA2017011900488Battery · dischargedEMERGENCY LIGHTS IN FWD GALLEY INOP. REPLACED BATTERY PER AMM 33-51.SDR DALA2017011900487Lens · damagedFWD DOOR 2R EMERGENCY LT LENS DAMAGED (EXTERIOR). REMOVED AND REPLACED 2R DOOR EMERGENCY LIGHT LENS PER AMM 33-51.SDR DALA2017011800469Light · unknownEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. RELAMPED EMER FLOOR LIGHTING PER AMM 33-51.SDR DALA2017011700416Unknown · odorAFTER T/O F/A NOTICED AN ELECTRICAL ODOR IN FIRST CLASS. THERE WERE NO VISIBLE SIGNS OF SMOKE. F/A REPORTED ELEC SMELL STRONGEST BY L1 AND FAINT BY R1 THRU MID B/C. T/S PER B767-4 FIM 21-00-21. CKD RECIRC FANS, GASPER FANS, IFE SYS, FWD GALLEY OVENS, COFFEE MASDR DALA2017020300934Fairing · delaminatedON WALKAROUND FOUND RT WING NR 7 FLAP LINKAGE FAIRING DELAMATED WITH SMALL HOLE. REPAIRED PER SRM 57-53-70 PG 103 STEPS A AND F APPLIED SEALANT AND SPEED TAPE NEED TO REINSPECT AT 300 FLT INTERVALS REPAIR ON OR BEFORE 3000 FLT CYCLES OR 18 MONTH. INSTALLED PERSDR DALA2017011100249Structure · damagedHOLES ELONGATED ALONG FWD EDGE OF GENERATOR CABLE PASS THROUGH CUTOUT APPROX NACELLE STA 227 NBR 1 PYLON UPPER SURFACE. REPAIRED PER PRI 553929-14 REV 0-3. PRI 553929-14 REV 0-3 INSTRUCTIONS MATCH FINAL ERA 553929-14 REV A INSTRUCTIONS. (2844045)SDR DALA2017011100248Structure · crackedPYLON CRACKED AT CUTOUT WHERE POWER FEED WIRES PASS THRU TO UPPER PYLON. REMOVED AND REINSTALLED O/B T/R ON AMDS 7831-4202. PRI 553929-14 INSTRUCTIONS REV. 0-4 MATCH FINAL ERA 553929-14 REV. A INSTRUCTIONS. (2844042)SDR DALA2017010300054Failsafe · crackedULTRASONIC INSPECTION IAW STEP 8 SHOWS A CRACK INDICATION IN THE FAILSAFE STRAP. REPAIRED IAW AMDS 5312-01170-10A.SDR DALA2017010300050Failsafe · crackedBHEC IAW STEP 2 OF 5312-01170-10A-02 REVEALS A CRACK INDICATION IN LOWER HOLE OF INSPECTED AREA IN LT FAILSAFE STRAP ONLY. REPAIRED IAW AMDS CARD 5312-01170-10A-02.SDR DALA2017010300051Battery Pack · inoperativeEMERGENCY LIGHTS AT SEATS 22B THRU 27B INOPERATIVE. REPLACED THE EMERGENCY LIGHT BATTERY AND CHARGER IAW AMM 33-51.SDR DALA2016123010164Connector · disconnectedEMERGENCY LIGHT 22GF TO 27GF INOPERATIVE. TROUBLESHOT IAW FIM 33-51. FOUND CONNECTOR FROM SIDE WALL TO SEAT DISCONNECTED IN SIDE WALL RECONNECTED ALL OPS NORMAL.SDR DALA2016122910162Lens · missingR1 DOOR RED TRACK EMERGENCY LIGHT LENS IS MISSING. REPLACED THE LENS.SDR DALA2016122110076Pitot Tube · inoperativeAFTER TAKE OFF, EICAS MESSAGE F/O PITOT. CIRCUIT BREAKER CHECKED IN. QRH COMPLIED WITH, CONSULTED WITH MX AND DISPATCH, DUE TO ICING CONDITIONS ACFT DIVERT. R & R FO'S PITOT TUBE IAW AMM 34-11-01. TESTED AND LEAK CHECKED GOOD.SDR DALA2016122110075Bushing · migratedNR 10 SPOILER LOWER ATTACH POINT BUSHING HAS MIGRATED. REMOVED SPOILER ACTUATOR FWD BOLT IAW AMM 27-61-02, INSPECT BUSHINGS IAW DWG 113T1420, OUT OF LIMITS IAW SPM 20-10-06. INSTALLED A NEW BUSHING IAW SPM 20-10-06 AND INSTALLED THE SPOILER ACTUATOR FWD BOLT SDR DALA2016121609924Skin · wornNR 12 SLAT T/E WEDGE LOWER SKIN WORN THRU AT OTBD TRACK. COMPLETED REPAIRS IAW SRM 57-43-02 REPAIR 1.SDR DALA2016121209766Battery Pack · inoperativeEMERGENCY BATTERY INOPERATIVE. REMOVED AND REPLACED THE BATTERY AND CHARGER ASSY IAW AMM 25-29-08.SDR DALA2016120909762Skin · corrodedCORROSION FOUND ON SKIN AT BS 929.60 RT SID. REPAIRED.SDR DALA2016120709661Charger · inoperativeEMERGENCY LIGHTS INOP FROM 30G-37G. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY CHARGER AT SEAT 30G.SDR DALA2016120709660Web · crackedNR 1 PYLON UPPER WEB CRACKED AT IDG FEEDER CABLE CUTOUT. C/W REPAIR OF NR 1 PYLON UPPER WEB PER PRI 553081-14 REV 3. PRI 553081-14 REV 3 AND ERA 553081-14 REV ORIGINAL.SDR DALA2016120709659Fastener · damagedLIGHTNING STRIKE AT STA 385, STR 28L. REMOVED DAMAGED FASTENER, PERFORMED DETAIL VISUAL INSP, TREATED AND PAINTED AREA, INSTALLED BLIND FASTENER PER SRM 53-00-01, FIG 201, REPAIR 8, SECT II. NEEDS REPETITIVE INSP EVERY 1500 CYCLES AND PERM REPAIR REQUIRED AT SDR DALA2016120709658Fastener · damagedLIGHTNING STRIKE AT STA 382, STR 29L. REMOVED DAMAGED FASTENER, PERFORMED DETAIL VISUAL INSP, TREATED AREA, INSTALLED BLIND FASTENER AND PAINTED AREA PER SRM 53-00-01, FIG 201, REPAIR 8 SECT II. NEEDS REPETITIVE INSP EVERY 1500 CYCLES AND PERM REPAIR REQUIRED
Back to Boeing 767-432ER