SDR DL764080364Pin · backed outDURING CHK OF EMERGENCY LIGHTS/OXY PANEL FOUND MANUAL DEPLOYMENT FAIL. FOUND K466 ON P19 BAD ALSO PIN 3 OF RELAY SOCKET PUSHED BACK. RESECURED PIN 3 AND REPLACED RELAY K466 CHKS GOOD PER AMM.SDR DL764080363Switch · intermittentEMERGENCY LIGHTS ILLUM WITH ALL EMERG SWITCHES IN OFF DISARMED POSITION WHEN EXTERNAL PWR TURNED OFF. FOUND EMERGENCY LIGHTS ARMING SWITCH INTERMITTENT. REPLACED PANEL, CHKS GOOD PER AMM.SDR DL764080317Blades · shearedCREW REPORTS RT ENG COMPRESSOR STALL DURING INITIAL PWR FOR T/O. ABORTED T/O AT 10 KTS, CREW OBSERVED RT EGT DROP TO NEAR ZERO FOR A BRIEF SECOND AFTER BANG. NO EICAS MESSAGES, MTC IN PROGRESS. ALITALIA BORO INSP IN WORK. BOROSCOPE INSPECTION REVEALED 3 BLSDR DL764080304Isolation Valve · inoperativeREPEAT EICAS MSG R BLEED ISOLATION VALVE DISPLAYED WITH R ISLN LIGHT ILLUM WITH SWITCH UNLATCHED. BOTH ENGINES RUNNING AND APU SHUTDOWN. REMOVED AND REPLACED RT BLEED ISOLATION VALVE. RAN RT ENG, OPS AND LEAK CHECK GOOD.SDR DL764080300Start Valve · inoperativeL ENGINE START VALVE FAILED TO OPEN. AIR PRESSURE WAS NORMAL-30PSI. VALVE DISAGREE LIGHT REMAINED ON. L ENGINE START VALVE FAILED TO OPEN. AIR PRESSURE WAS NORMAL-30PSI. VALVE DISAGREE LIGHT REMAINED ON. FWD TO MCO PLACARD PER MEL 80-20-02.SDR DL764080270Sensor · malfunctionedON TAXI TO RUNWAY, THE FOLLOWING LIGHTS REMAINED ON AFTER ENG START, LEFT CTR FUEL PUMP/L ENG BLEED VALVE/LEFT EFIS CONTROL. T/S PER FIM 77-12-0, EXAMINED CIRCUIT BETWEEN N2 SENSOR AND DCUS FOUND OK. VERIFIED RESISTANCE OF N2 SENSOR OK CLEANED AND REINSTALLESDR DL764080246Rudder Pedal · out of adjustDURING FLT CONTROL CHECK, F/O RT RUDDER PEDAL HITS THE AFT STOP COVER. RTB ADJ RUDDER PEDALS TO NML CONFIG. RAN PEDALS FULL LT AND RT PEDAL DOES NOT HIT THE SHROUD. PEDALS ARE EVEN ALL POS AND IND NML.SDR DL764080251Line · leakingAPU LEAKING OIL AT SCAVENGE LINE FITTING TURBINE BEARING. REMOVED AND REPLACED APU PER TRANSMITTAL 14T102 OP AND LK CK OK.SDR DL764080189Unknown · malfunctionedLEFT VHF PANEL STARTED DISPLAYING FAIL INTERMITTENTLY THEN CONTINUOUSLY. RESET CB, FAIL WENT AWAY BUT COULD NOT TRANSMIT OR RECEIVE ON VHF OR STACOM. RT VHF AND STACOM WAS ABLE TO RECEIVE BUT NOT TRANSMIT. AFTER 10 MIN, RT VHF COULD TRANSMIT ON A HANDFULL OSDR DL764080187Actuator · leakingCENTER HYDRAULIC QUANTITY DROPPED AT 28 PERCENT IN FLIGHT FL 300. FOUND RT MLG RETRACT ACTUATOR LEAKING. REPLACED ACT PER M/M LEAK CHECK GOOD.SDR DL764080180Valve · failedRTB - RT HYD SYSTEM QTY WENT TO ZERO. REPLACED B BRAKE RT SIDE FUSE AND ANTI-SKID VLV ON RT SIDE BRAKE ANTI-SKID MODULE PER AMM. LK CK OK. OPS CKS GOOD PER MM. SERVICED HYD SYSTEM RT SIDE PER MM.SDR DL764080175Liner · failedREPLACE RT ENG DUE TO FAILED BORO 50131. COMP INNER LINER AXIAL CRACKS. ON 25 CYCLE FLYBACK, REPLACED ENGINE.SDR DL764080170Connector · damagedFOUND SEAT 7AB EEPL CONNECTOR IS DAMAGED. REPLACED CONNECTOR AT SEAT 7AB, OPERATIONALLY CHECKS GOOD IN ACCORDANCE WITH B767-400 MM 33-51-00-715-200.SDR DL764080169Connector · damagedEMERGENCY LIGHTS INOP AT SEATS 38FG THRU 44FG, REMOVED AND REPLACED ELECTRICAL CONNECTOR AT SEAT ROW 44FG IAW SWPM 20-10-13 AND OPS CHECKED GOOD IAW B767-400 MM 33-51-10.SDR DL764080167Connector · looseEMERGENCY LIGHTS INOP FROM 38A TO 41A, CABLE CONNECTOR AT SEAT 42A WAS LOOSE, RECONNECTED CABLE CONNECTOR AT SEAT 42A. PERFORMED GOOD OPS CK OF EMERGENCY LIGHTS FOR SEATS 38A-41A IAW DAL B767-400MM 33-51-00 AND 33-51-05.SDR DL764080135Oven · overheatedFIRST GLASS OVEN CB POPPED AND ELECTRICAL SMELL. REPLACED NR 2 OVEN. CKS GOOD. REMOVED MCO AND PLACARD.SDR DL764080123Filter · dirtyRETURN TO GATE AFTER ENGINE START. EICAS MSG RT ENG FUEL FILTER. REPLACED RT ENG FUEL FILTER ELEMENT AS PER AMM 73-11-02-004 AND AMM 73-11-02-404 CHECKED OK.SDR DL764080118Pump · malfunctionedLT AFT FUEL PUMP LIGHT AND MSG ON AFTER PUSHBACK. PER DISPATCHER NEEDED MORE FUEL IN ORDER TO DISPATCH WITH MEL APPLIED. RETURNED TO BLOCK FOR FUEL. MX PLACED PUMP ON MCO PER MEL 28-22-01A. SECURED C/B.SDR DL764080105Battery · inoperativeBATTERY AT CHARGER M12 STA 1545 RBL 53 BATTERY WON`T CHARGE. REMOVED AND REPLACED BATTERY, DURING HMV1 AT TIMCO IN GSO ON NR 44981.SDR DL764080104Charger · inoperativeBATTERY CHARGER M1208 STA 284 LBL 53 INOP. REMOVED AND REPLACE BATTERY CHARGER ON N/R 44980 DURING HMV1 AT TIMCO IN GSO.SDR DL764080103Charger · inoperativeBATTERY CHARGER M734 STA 1384 RBL 95 LIGHTS INOP AFTER 5 MINUTES. REMOVED AND REPLACED BATTERY CHARGER M734 ON NR 44975, DURING HMV 1 AT TIMCO IN GSO.SDR DL764080102Charger · inoperativeBATTERY CHARGER M7236 STA 1197 PLUS 77 LBL 94 LIGHTS INOP AFTER 5 MINUTES. REMOVED AND REPLACED BATTERY CHARGER M7236 DURING HMV 1 AT TIMCO IN GSO ON NR 44974.SDR DL764080101Charger · inoperativeBATTERY CHARGER M6759 STA 841 LBL 94 LIGHTS INOP AFTER 5 MINUTES. REMOVED AND REPLACED BATTERY CHARGER DURING HMV 1 AT TIMCO AT GSO ON NR 44973.SDR DL764080100Charger · inoperativeBATTERY CHARGER M7235 STA 654A PLUS 33 LBL 94 LIGHTS INOP AFTER 5 MINUTES. REMOVED AND REPLACED BATTERY CHARGER M7235 ON NR 44972, DURING HMV AT TIMCO IN GSO.SDR DL764080099Charger · inoperativeBATTERY CHARGER M730 STA 401 RBL 95 LIGHTS INOP AFTER 5 MINUTES. REMOVED AND REPLACED BATTERY CHARGER OPS CK GOOD. REPLACED DURING HMV1 ON N/R 44971 AT TIMCO IN GSO.SDR DL764080074Compressor · failedATB DUE NR 2 ENGINE SURGE ENGINE WAS NOT SHUTDOWN C/FOUND METAL IN TAILPIPE. REPLACED NR 2 ENG. REPLACED RIGHT ENGINE.SDR DL764080028Monitor · malfunctionedRTO DUE AT 60 KTS LT HYD QTY INDICATION DROPPED TO ZERO. MTC FOUND LT QTY IND AT TANK FULL. FWD LT QTY IND TO MCO AND PLACARD. INSPECTED AND SHOOK DOWN WIRING AND CP AT TRANSMITTER. NTF. CO NOT DUPLICATE REPLACED HYD QTY MONITOR M122 AS PRECAUTION DUE TOSDR DL764080033Actuator · leakingCENTER HYD RSVR LIGHT JUST AFTER LEVEL-OFF FOLLOWED CHECKLIST RETURNED FOR LANDING LND WT 398.0LBS. FOUND RIGHT ELEVATOR CENTER HYD PCA LEAKING. REPLACED PER AM LEAK CHECK OK. RII INSPECTION COMPLETED PER TOPP 40-30-05.SDR DL764080026Actuator · leakingSHORTLY AFTER TAKEOFF FROM HNL FLIGHT 1282 NOTIFIED MCC THAT CTR SYS HYD WAS LOSING FLUID. HAD THE CREW SECURE CTR PUMPS AND QTY STABILIZED. CREW RETURNED TO HNL. TROUBLESHOOTING IN PROGRESS. FOUND RT ELV PCA LEAKING. REPLACE CK OK.SDR DL764080025Relay · malfunctionedAT DEPARTURE EMERGENCY LIGHT WOULD NOT TURN OFF. REPLACED BATTERY PACK M1208 AND M796. SYSTEM WORKED FOR A SHORT TIME AND THEN FAILED AGAIN. TROUBLESHOOTING IN PROGRESS. REPLACED RELAY K10361 ALL EMERGENCY LIGHTS CK NORMAL.SDR DL764080009Battery · overheatedON PRE-DEPARTURE CHECK ALL PASSENGERS OFF AIRCRAFT. FOUND SMOKE IN AFT CABIN. CORRECTIVE ACTION WAS TO REPLACE APU BATTERY FOR SMOKE AND APU BATTERY CHARGER PRECAUTIONARY.SDR DL764090009Start Valve · inoperativeEICAS MSG RT STARTER CUTOUT ILLUMINATED IN FLIGHT. DUE TO QRH PROCEDURES AND ICING CONDITIONS IN ATL HAD TO DIVERT TO MIA FOR REPAIR. REMOVED AND REPLACED RT ENG START VALVE PER AMM. SPUN ENG AT GATE. START VALVE CKS GOOD.SDR DL764071640Skin · dentedDURING HMV AT TIMCO GSO, THE FUSELAGE SKIN WAS FOUND DENTED OUT OF LIMITS AT STA 1373 BETWEEN S-28R AND S-29R. THE DAMAGE WAS CUT OUT AND REPAIRED PER ER/A 465100-14.SDR DL764071629Skin · dentedSKIN DENTED AT FS 654A+110 TO FS 654 S29R TO 30R. DAMAGE CUTOUT AND A REPAIR DOUBLER INSTALLED.SDR DL764071627Light · inoperativeL2 EXTERIOR EMERG SLIDE LIGHT IS INOP. RELAMPED L2 EXTERIOR EMERGENCY SLIDE LIGHT, LIGHT OPS CHECKS GOOD IAW B767-400 MM 33-51-06.SDR DL764071626Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK ROW 24 LEFT IS DEFECTIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK IAW B767-400 AMM 33-51-07. NO FAULTS NOTED ON OPS CHECK IAW B757-400 AMM 33-51-07.SDR DL764071630Power Supply · inoperativeLT EMERGENCY LIGHTS IN C ZONE ARE INOP. T/S SUPPLY POWER NO OUT RT REPLACED POWER SUPPLY OPS CHECK GOOD PER B767 MM 33-51-08.SDR DL764071628Light · inoperativeR4 EXTERIOR EMERG SLIDE LIGHT IS INOP. RELAMPED R4 EXTERIOR EMERGENCY SLIDE LIGHT, LIGHT OPS CHECKS GOOD IAW B767-400 MM 33-51-06.SDR DL764071625Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK ROW 32 RIGHT IS DEFECTIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AND POWER SUPPLY IAW B767-400 AMM 33-51-07. NO FAULTS NOTED ON OPS CHECK IAW B757-400 AMM 33-51-07.SDR DL764071624Charger · defectiveEMERGENCY LIGHT BATTERY CHARGER ROW 6 LEFT IS DEFECTIVE. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY IAW B767-400 AMM 33-51-07. NO FAULTS NOTED ON OPS CHECK IAW B767-400 AMM 33-51-07.SDR DL764071604Skin · damagedFOUND DEBRIS STUCK FUSELAGE AT FS 1395-1439. INSTALLED SKIN REPAIR DOUBLER.SDR DL764071581Fan Blade · bird ingestionBIRD STRIKE DURING T/O OUT OF DKR, LT ENG VIBS WENT TO 5.0. ALL OTHER PARAMETER NORMAL. RETURNED TO DKR. MTC FOUND 5 FAN BLADES DAMAGE OUT LIMITS AND 1 OGV WITHIN LIMITS. SENDING PARTS ON FLT 34/02. WILL NEED UPDATE WHEN MTC COMPLETE MA KEY 5-0145. REMOVSDR DL764071580Oven · unserviceableFAS REPORTED A SCREECHING SOUND WHEN STARTING FWD NR 1 OVEN. SUBSEQUENT HOT ELECTRICAL SMELL IN FWD GALLEY. FWD OVENS WERE SHUT OFF AND SMELL DISSIPATED. NR 1 OVEN IS BELIEVED TO BE SOURCE OF ODOR. PULLED FWD GALLEY U-33 CIRCUIT BREAKER AS PRECAUTION. RESSDR DL764071516Charger · inoperativeRT EMERGENCY LIGHTS ROW 30-37 OUT. REMOVED AND REPLACED BATTERY CHARGER AT ROW 37 RIGHT. OPS CHECK GOOD IAW B767-400 MM 33-51-04.SDR DL764071513Lamp · inoperativeRI DOOR SLIDE LIGHT INOP. RELAMP LIGHT INDICATOR IAW DALB767-400 MM 33-13-00. OPS CHECK GOOD IAW DAL B767-400 MM 52-73-00 STEP E1-E9.SDR DL764071514Light · inoperativeSLIDE LIGHT AT 1L DOOR INTERMITENT. RELAMP SLIDE LIGHT IAW DAL B767-400 33-13-00. OPS CHECK GOOD IAW B767-400 MM 52-73-00 STEP E1-E9.SDR DL764071515Wire · brokenLEFT WING EMERGENCY EXIT LIGHT IN COCKPIT. TROUBLESHOOT FOUND BROKEN WIRE NR 916-222R-20 IN CROWN OF CABIN IAW DAL B767-400 WDM 52-71-15, SPLICED WIRE W916-222R-20 IAW BSWPM 20-10-13. OPS CHECK GOOD IAW DAL B767-400 MM 52-71-00.SDR DL764071501Relay · failedA/C FAILS AUTO O2 DEPLOYMENT. REMOVED AND REPLACED RELAY K455 IAW B767-400 WDM 35-51-21-11. PERFORMED OPS CHECK OF AUTO DEPLOY O2 SYSTEM IAW B767-400 MM 35-21-00-705-054. PROCEDURE F OPS CHECK GOOD.SDR DL764071500Battery Pack · dischargedEMERGENCY LIGHTS AT SEATS 30 GF THRU 37GF ARE INOP. REMOVED AND REPLACED BATTERY PACK IAW B767-400 MM 33-51-07-022-005. OPS CHECKS GOOD IAW B767-400 MM 33-51-07-022-05.SDR DL764071499Connector · not seatedPSU AT SEAT 46CDE FAILS O2 DEPLOYMENT. RESEATED LOOSE CONNECTOR. PERFORMED OPS TEST OF PASSENGER OXYGEN SYSTEM IAW B767-400 MM 35-21-00-705-054. OPS TEST GOOD.
Back to Boeing 767-432ER