Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011062003020Battery · faultedUPON DELIVERY FROM HANGAR, FLT CONTROL EICAS MESSAGE DISPLAYED. REPLACED LEFT FC BATTERY & POWER SUPPLY ASSY PER AMM, MESSAGE CLEARED.SDR UALA2011062002994Connector · unsecureFIRST CLASS SEAT EMERGENCY LIGHTS ALL INOPERATIVE. SECURED CONNECTOR UNDER SEAT 8D, OP CHECKED OKAY.SDR UALA2011062002988Acm · malfunctionedRT PACK TRIP REPLACED RIGHT ACM, OPS CHECK NORMAL. ALSO REPLACED ASCPC, ALL NO HELP, PACK TRIPS IN 8 MIN OR LESS. REPLACED RIGHT PACK FLOW SENSING VENTURI PER MM.SDR UALA2011061702980Controller · malfunctionedRT ANTI-ICE ENG FAULT, RTFL. ANTI-ICE RIGHT ENGINE FAULT ON EICAS. NO TIME TO T/S DEF PER MEL. REPLACED CONTROLLER AS PER MM. PERFORMED ENGINE RUN AS PER. JRH ALL INDICATIONS GOOD.SDR UALA2011061502958Light · inoperativeAFT EMERGENCY LIGHT ON SEAT 2F IS INOP. REPLACED AFT LIGHT ON SEAT 2F, OPS CHECKS GOOD.SDR UALA2011061502957Actuator · inoperativeON ARRIVAL FOUND STATUS MESSAGE 'RAM AIR INLET DOOR LT'. FOUND LATCHED. UNABLE TO UNLATCH. DEACTIVATED IN FULL OPEN POSITION. PER MEL PROCEEDURES. CHECKED MECHANICAL LINKAGE FOR THE RAM AIR INLET DOOR AND NO FAULT FOUND. REPLACED LT INLET DOOR ACTUATOR.SDR UALA2011061502940Slat · damagedRT WING NR 8 LEADING EDGE SLAT HAS DAMAGE.SDR UALA2011061702970Valve · failedEAI VALVE, RIGHT ENGINE ANTI-ICE (EAI) VALVE FAILURE. STATUS MSG-3010112 LATCHD ER MODE. LOCKED IN CLOSE POSITION DF FOR TIME. REMOVED CONNECTOR DM30211A FROM THE CONTROLLER. REPLACED ENG ANTI-ICE VALVE PER MM. RAN ENG ANTI-ICE VALVE, OPS GOOD.SDR UALA2011061502941Module · faultyINTERMITTENT STATUS MSG OF DISPLAY RESOURCES HAS OCCURRED. MSG 31-81052, CPM-GG M010 FAULTED. REPLACED M010 AND LOADED ALL SW AS NEEDED. SYSTEM CHECKS NORMAL.SDR UALA2011061402933Engine · oil consumptionNR 1 ENG OIL CONS EXCEEDS LIMIT. T-S PER FIM 71-05 T830. PER AD 2003-26-09, IF EXCD 0.5 QT PER HOUR AND NO CAUSE FOUND, BORO NR 3 WEEP MM TASK 72-00-88-290-803-N01 WITHIN 100 CY. FIM 71-05TSK830 WAS ACPD WITH NO DEFECTS FOUND, AFTER ECM DATA & ACFT OIL MONITSDR UALA2011061402930Idg · malfunctionedRIGHT ENG GEN FAULT, FLIGHT DIVERTED. REMOVED AND REPLACED NR 2 ENG IDG PER MM, OPS CHECK NORMAL.SDR UALA2011061402934Relay · failedELECTRIC STBY SYS EICAS AND STATUS MESSAGE. REPLACED RELAY K24013 IN P 210 PANEL. STBY PWR OPS CHECK GOOD. NO MSG DISPLAYED.SDR UALA2011061402932Gcu · faultyELEC GEN OFF R RIGHT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF, AND ENGINE NOT SHUT DOWN. ADVISORY. CREW COMMENTS: ATTEMPTED 1 RESET, UNSUCCESSFUL. APU NOW RUNNING FOR ELECTRICS. MSG-2431632 LATCHD TA MODE. REPLACED GCU PER MMSDR UALA2011061402931Controller · malfunctionedWINDOW HEAT INOP RIGHT FWD WINDOW. REPLACED WINDOW HEAT CONTROL PER MM.SDR UALA2011061302922Start Valve · faultyLEFT ENGINE START VALVE MESSAGE. VALVE IS DEFECTIVE. REPLACED START VALVE PER MM. OPS NORMAL.SDR UALA2011061302883Ballast · smokeDURING FINAL APPROACH 4000FT SEATS 44AB OVERHEAD LIGHT ASSEMBLY SMOKING. FOUND BALLAST UNIT WITH HEAVY BURNED ELECTICAL SMELL ABOVE SEATS 44ABC. NO EVIDENCE OF FIRE. CAPPED AND STOWED BALLAST UNIT. LIGHT BULB REMOVED.SDR CNMA20110031Lamp · inoperativeL3 EXTERIOR EMERGENCY LIGHT INOPERATIVE. RELAMPED. OPS CHECKED GOOD IAW AMM.SDR UALA2011061302912Circuit Card · malfunctionedCARGO HEAT VALVE AFT FAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). STATUS MSG-2112021 LATCHD ER MODE. REACTIVATED SYSTEM, RAN TEST ON MAT, TEST FAILED DUE TO CARD CONNECTION PROBLEMS WITH FIM MSG 45-19667. CYCLED POWER TO BOTSDR UALA2011061302911Coupler · faultyEAI VALVE R RIGHT ENGINE ANTI-ICE (EAI) VALVE FAILURE. REPLACED B23126 COUPLER OPBC-1 IN P111. OPS CHECKS GOOD, REACTIVATED EAI.SDR UALA2011061302893Valve · failedCENTER TANK SCAVENGE SYSTEM TRANSFERED FUEL BEFORE MAINS REACHED 50000LB SAMC TEXT: FUEL SHEET NOTED WITH \NR 2 TANK VTO EARLY'. FUEL SCAVENGE SYS FUNCTIONALTEST IAW MM. FOUND BOTH OUTLET FLOAT VALVES FAILED OPEN. FUEL KEEPS SCAVENGING FROM CTR TANK TO BOTSDR UALA2011061302880Idg · malfunctionedGENERATOR SYSTEM RT STATUS MESSAGE, IDG DROPPED OFF LINE, DISCONNECTED IDG PER FM. CMC FAULT SHOWS IDG RIGHT FREQUENCY IS LOW. REPLACED NR 2 IDG PER MM. RAN ENGINE OPS CHECKED OK. IDG DISCONNECTED AND RECONNECTED CHECKED OK.SDR UALA2011061302876Battery · dischargedEICAS MESSAGE AFTER PUSHBACK. MAIN BATTERY DISCHARGE NO LAND 3. REPLACED MAIN BATTERY AS PER MM, ALL OPS AND INDICATIONS NORMAL.SDR UALA2011061302885Module · faultyHEAT PITOT L LOSS OF LEFT PITOT HEAT. MAT SHOWS MAINT MSG 30-361 21. MEL 3031B PROCEDURES DONE. REPLACED LEFT ADM PER MM.SDR UALA2011061002858Structure · damagedFWD CARGO DOOR AFT LOWER CORNER HAS DAMAGE. DAMAGE IS (12 INCHES LONG) WITH SEVERAL RIVET HEADS POPPED. REPAIRED CARGO DOOR DAMAGE & REPLACED DAMAGED FASTENERS PER SRM. NDT COMPLETE, NO CRACKS NOTED. ACCOMPLISHED INSPECTION OF REPAIR, CHECKED OKAY.SDR UALA2011061002854Control Panel · faultyWX RADAR TILT LEVEL DISPLAY IS NOT CONSISTENT WITH SELECTED TILT LEVEL. REPLACED WX CONT PANEL, OPS CHECK OKAY.SDR UALA2011060902841Light · missingSEAT 1E AFT EMERGENCY LIGHT STRIP MISSING. REPLACED EMERGENCY LIGHT PER MM.SDR CNMA20110030Light · intermittentF/A REPORTED, EMERGENCY EXIT LIGHTS ILLUIMINATED SEVERAL TIMES DURING CLIMBOUT. OPS TEST OF EMERGENCY LIGHTS. CHECKED GOOD. NO FAULTS AT THIS TIME.SDR UALA2011060902846Warning System · malfunctionedFLAP-SLAT SKEW SENSORS FAILURE OF ONE OR MORE SLAT AND-OR FLAP SKEW DETECTION SENSORS. LOSS OF SLAT AND-OR FLAP SKEW DETECTION SENSOR REDUNDANCY. STATUSMSG-2720291 ACTIVE AP HARD. DURING FLAP OPS FOUND L2A INDICATION ABNORMAL -005. SUSPECT BAD L2A SKEW SENSDR UALA2011060902844Liner · tornNR 2 ENG 10:OCLOCK POSITION SEGMENT FAN EXIT LINER IS TORN APPROX 4-5 INCHES.SDR UALA2011060802827Lamp · inoperativeSEAT 5F EMERGENCY AFT EMERGENCY LIGHT INOP. RELAMPED, OPS GOOD.SDR UALA2011060802831Terminal Block · corrodedFOUND CORRODED TERMINAL BLOCK IN AFT PIT. PICS ON RVI. REPLACED GROUND BLOCK GB46008B, NORMAL OPERATION RESTORED TO AFT CARGO LOADING SYSTEM, CKS OKAY.SDR UALA2011060702789Idg · faultyL IDG DISCONNECT. FOUND MAINTENANCE MSG IN HISTORY: 24-31631 IDG L FREQUENCY IS LOW. ACCOMPLISHED FIM 24-11, TASK 805, INDICATES IDG REPLACEMENT. REMOVED L IDG. INSTALLED IDG ON LEFT ENGINE PER MM.SDR UALA2011060802829Valve · malfunctionedRIGHT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION OR STARTER AIR VALVE POSITION INDICATION IS LOST. STATUS MSG01- NOT ACTIVE ENGINE SHUTDOWN MODE DEPENDENT; STARTER AIR VALVE (SAV) (R ENG) IS NOT IN COMMANDED POSITION. DB- ELECTRONIC ENGINE CSDR UALA2011060602771Unknown · malfunctionedAFTER PUSHBACK, CREW STATES RT ENG FUEL VLV MSG DISPLAYED. TRIED 2 START ATTEPMTS, NO JOY. REPLACED NR 2 ENG FMU, NO HELP FOR MSG 73-60212, THEN HAD CORRELATED SPAR VLV MSG 28-14002, REPLACED R-RNG SPAR VLV ACT, NO HELP, REPLACED K28222 IN P101, R-ENG STARTESDR UALA2011060602769Shutoff Valve · faultyRIGHT PACK OFF LIGHT FLICKERS. REPLACED RT PACK SHUTOFF VALVE. OPS OK. UPPER FCV VALVE WAS REPLACED. ACFT RTBL WITH RT PACK SHOWING FLOW WITH RT PACK SELECTED OFF DURING ENGINE START. REPLACED LOWER RT FLOW CONTROL VALVE, NO HELP. REINSTALLED OLD VALVE ASDR UALA2011060602746Hinge · damagedEXTERNAL GROUND POWER DOOR PANEL HINGE DAMAGED. LOWER HINGE ON GROUND POWER DOOR IS BENT. DOOR NEEDS TO BE TAPED CLOSED AT DEPARTURE. ENSURE EXT PWR DOOR IS CLOSED LATCHED AND SECURE BEFORE EACH DEPARTURE. INSTALLED NEW SPEED TAPE TO MAINTAIN FAIRNESS WITHSDR UALA2011060702788Gcu · faultyELEC GEN SYS L FAULTS. DUE TO RECENT HISTORY OF ELEC GEN SYS L FAULT, ACP FIM TASK 24-23-837. ACCOMPLISH FIM TASK INCLUDING WIRING CKS. INCLUDE OHMS AND CONTINUITY READINGS IN SIGNOFF. IF NO FAULTS ARE FOUND REPLACE THE RIGHT GCB (566-0549) PER AMM THE LESDR UALA2011060602744Fan · faultyCREW REPORTS ELECTRICAL TYPE ODOR IN AFT SECTION OF ECONOMY CABIN-GALLEY AREA. SMELL TRACKED DOWN TO AFT CARGO PIT AND TRACED TO BULK CARGO VENT FAN. DEACTIVATED PER MEL. REPLACED BULK CARGO VENT FAN PER AMM, OPS CHK NORMAL.SDR UALA2011070503312Transceiver · unserviceablePORTABLE VHF TRANSCEIVER PLASTIC TAMPER BAG SHOWS SIGNS OF TAMPERING. REPLACED VHF A3-AFT GALLEY.SDR UALA2011060302725Window · faultySTATUS MSG FOR LT SIDE WINDOW RETURNED PRIOR DEPT. REPLACED WINDOW.SDR UALA2011060302724Duct · dentedPRECOOLER BLEED DUCT AT 90 ELBOW AFTER PRECOOLER HAS DENT. REPLACED LOWER PRECOOLER TO PYLON DUCT, LEAK CHECK OKAY.SDR UALA2011060302708Drain Line · damagedLEFT PACK WATER EXTRACTOR WATER DRAIN LINE HAS PIN HOLE ON IT. DEFERRED PER MEL 2151B. LEFT PACK INOPERATIVE. REMOVED AND REPLACED DAMAGED LINE. LEAK CHECK C-OUT. NO LEAKS. PACK OPS SATISFACTORY.SDR UALA2011060302722Bottle · emptyL2 DOOR AIR ASSIST BOTTLE EMPTY. REPLACED ASSIST BOTTLE PER MM.SDR UALA2011060302723Modulating Valve · failedBLEED FAMV R RIGHT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED, OR RIGHT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG-3610340 LATCHD TA MODE. VALVE LOCKED FULL OPEN POSITION PER MEL. NEED MORE TIME TO TROUBLESHOOT. RESDR UALA2011060302709Actuator · leakingDURING W-A NOTICED HEAVY HYD LEAK COMING FROM LT MAIN GEAR TILT ACTUATOR. REPLACED LT GEAR TILT ACTUATOR PER MM. LEAK CHECK OK. PART IS A LOAN UNIT.SDR UALA2011060202695Ace · malfunctionedFLIGHT CONTROL SYS ANY CONDITION OF THE FLIGHT CONTROL SYSTEM OR IT'S SYSTEM INTERFACES WHICH WOULD PREVENT DISPATCH. FLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS, STATUS MSG-2710302 LATCHED TA MODE. REPLACED ACE L2 PER MM. ACE TEST OK. PFC SSDR UALA2011053102663Tube · damagedNR 2 ENG PYLON INBD DRAIN TUBE BROKEN OFF. REPLACED BROKEN DRAIN TUBE WITH A TIME LIMITED REPAIR TUBE PER MT 54-UA3. A CF ITEM WAS CREATED FOR A PERMANENT REPAIR.SDR UALA2011053102666Connector · shortedEMERGENCY LIGHTS ARE ON ONLY AT DOORS 4L AND 4R. FOUND CONNECTOR D3114P SHORTED INTERNALLY, WHICH IS POPPING CIRCUIT BREAKER H18 ON P11 IN FLIGHT DECK. USED WIRING DIAGRAM 33-51-16. CONNECTOR D3114P IS ABOVE DOOR 4R. REPLACED CONNECTOR D3114P WITH THE EXCEPSDR UALA2011060102676Module · faultyPA MSG, CSCP FAULTED SPEAKER DRIVER MODULE M23045. REPLACED SDM M23045, INSTALLED DATABASE, MESSAGE CLEARED. NEED DATABASE REINSTALLED AFTER SMC9 CONNECTOR REPAIR COMPLETE AT DR4R. CSCP STILL FAULTING OEU ABOVE DOOR 4R. CSCP STILL FAULTING OEU ABOVE DOOR 4RSDR UALA2011060102677Idg · overservicedELEC GEN SYS L IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (L) FREQUENCY IS LOW. DB- GENERATOR C
Back to Boeing 777-222