Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010010400053Connector · dirtyCREW OXYGEN PRESSURE LOW, FLT DIVERTED. INSTALLED NEW OXYGEN BLEED VALVE, NO HELP. REINSTALLED ORIGINAL BLEED VALVE. CONNECTER FOUND SOILED. CLEANED CONNECTOR, OPS CK OK. OXYGEN PRESSURE HOLDING 1740 PSI.SDR UALA2010010400047Connector · unsecureAFT EMERGENCY LIGHT AT SEAT 2F INOP. SECURED CONNECTOR, OPS CHECK NORMAL.SDR UALA2010010400040Fan · faultyF/A REPORTED ELECTRICAL ODOR IN CABIN. DURING FLT AFT CABIN ECONOMY PLUS REPORTED ELECTRICAL ODOR. CREW TURNED ALL 4 CABIN RECIRC FANS AND ODOR CLEARED. FOUND AFT UPPER RECIRC FAN POPS CB WHEN TURNED ON. VENTILATED AIRCRAFT. RAN REMAINING FANS, NO FURTHER SDR UALA2010010400054Connector · damagedPACK L OVERHEAT AT LT PACK OUTLET OR LT PACK COMPRESSOR OUTLET OR LT PACK FLOW CONTROL VALVES (FCV) ARE CLOSED DUE TO: FCVS FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (CTC) BECAUSE OF FAULT, OVERHEAT, OR PACK CONTROL SWITCH COMMANDED OFF, OR NSDR UALA2010010400004Light · missing2E EEL LIGHTING MISSING. REPLACED LIGHT ASSY, OP CHECKED GOOD.SDR UALA2009123104066Fan · failedSMOKE IN COCKPIT, FLIGHT DIVERTED. RT EQUIP COOLING SUPPLY FAN IS DEFECTIVE. CONFIRMED FAN BEARING ASSY FAILURE CAUSE OF FAULT AND RESULTANT ELECTRICAL ODOR. REPLACED RT EQUIP COOLING SUPPLY FAN ASSY. ALL OPS NORMAL.SDR UALA2009123004059O-Ring · leakingACFT LEAKING FUEL AT GATE. RIGHT WING PANEL 652HB REMOVED FOR T-SHOOTING FUEL LEAK. FOUND RT JETTISON PUMP LEAKING. REPLACED RT JETTISON PUMP O-RINGS. OPS CHKS NORMAL, NO LEAKS NOTED. REINSTALLED WING PANEL.SDR UALA2009123104071Engine · making metalAPU WILL NOT START. RESET CB'S B06, B07 ON P310 PANEL AND 'A03' ON P49 PANEL. NO HELP. INSTALLED NEW BYPASS VALVE SWITCH, NO HELP. CHECKED ACCESSORY CASE MASTER CHIP DETECTOR FOUND LARGE METAL CHUNKS. SUSPECT APU IS SEIZED. REMOVED AND REPLACED APU. OPS CHKSDR UALA2009123004058Shutoff Valve · inoperativeENGING DRIVEN PUMP SUPPLY VALVE INOPERATIVE. REPLACED ENG DRIVE PUMP SHUTOFF VALVE. OPOS CHECKED GOODSDR UALA2009122904053Generator · malfunctionedAFTER ENG RUN, LOST APU ELECTRICAL COULD NOT RESET. REPLACED APU GCU, NO HELP. REPLACED APU GENERATOR. OPS CHECKED NORMAL.SDR UALA2009122804035Cable · faultyPERSONAL VIDEO MONITOR DISPLAY INOP AT 37HJ THRU 42HJ. FOUND BB3-J18 CB POPPING. ISOLATED J18 SEAT GROUP, CB J18 STILL POPS, SUSPECT INPUT CABLE OR BUFFER BOX 3. REPLACE BUFFER BOX, NO HELP CB J18 STILL POPS. NO CABLE IAD. SEAT CABLE TO BE SENT TO IADMM UNDERSDR UALA2009122804030Igniter · failedENGINE IGNITOR L1 LT ENG FAILED TO IGNITE USING IGNITOR 1. STATUS CREW COMMENTS: STATUS MSG ENG IGN L1 MSG-7461491 INACTV ES MODE. REPLACED L1 UPPER IGNITOR PLUG. REPLACED L1 UPPER IGNITOR. CABLE AND REPLACED L1 UPPER IGNITOR. EXCITER BOX. ACCMP'D AUDIBLE SDR UALA2009122403990Control Valve · faultyFLOW CONTROL VALVE CAUSES RT PACK TO SHUTOFF. UPPER & LWR FCV'S LATCHED MX. REPLACED LWR FLOW CONTROL VALVE AND TESTED WIRING TO THE ECONO VLV IAW FIM. WIRING TESTED GOOD. RETESTED AND TEST FAILED. UPPER FCV STILL NEEDS REPLACING AND CABIN TEMP CONTROLLERSDR UALA2009122403996Seal · leakingUPON ARRIVAL, FUEL WAS LEAKING FROM THE FWD SIDE OF PANEL 533BB (5TH PANEL OUT FROM WINGROOT) UNDER WING ACCESS PANEL. REPLACED SEAL AND MESH GASKET. LEAK ABATED.SDR UALA2009122303985Control Valve · malfunctionedPACK FCV L STATUS MSG. ON LT PACK TROUBLESHOOTING, BOTH PACK FCVS HAD DIFFERENT PROBLEM ON GROUND TEST. SWAPPING ONE BENEATH THE OTHER UPPER AND LOWER PACK FCV. NOW THE UPR FLOW CONTROL VALVE OPS & INDICATION NORMAL. TEST THROUGH CABIN CTLR PASSED. THE LOSDR UALA2009122303986Inlet · gougedNR 2 ENG INLET WAS GOUGED AND SCRATCHED AT THE 4:30 POSITION WHEN THE FLIGHT CREW TAXIED INTO A BREAKAWAY STOP SIGN.SDR UALA2009122303984Antenna · damagedUPON ARRIVAL FOUND RT VHF ANTENNA DAMAGE. ANTENNA FOUND DAMAGED. REPLACED RT VHF ANTENNA. OP CHKS GOOD.SDR UALA2009122203971Circuit Card · faultyBLEED ISOLATION VALVE C CENTER BLEED ISOLATION VALVE NOT IN COMMANDED POSITION. STATUS MSG-3610150 LATCHD CL MODE MSG-3610170 INACTV CL MODE. NEEDS ASCPC. REPLACED LEFT ASCPC, NO HELP. REINSTALLED OLD CONTROLLER. SUSPECT BAD VALVE. INSTALLED NEW VALVE, NO HELPSDR UALA2009122203970Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT DR 2 LT IS OUT. RELAMPED. OPS CHECKS GOOD.SDR UALA2009122203969Light · missingSEAT 2E EMERGENCY LIGHT MISSING. REPLACED LIGHT ASSY. OPS CHECKS GOOD.SDR UALA2009122203968Light · inoperativeEMERGENCY LIGHT AT SEAT 33G IS OUT. REPLACED LIGHT ASSY. LIGHT OP CHECKS OK.SDR UALA2009122203967Light · inoperativeEMERGENCY LIGHT AT SEAT 41D IS OUT. REPLACED LIGHT ASSY. LIGHT OP CHKS OK.SDR UALA2009122203966Light · faultyEMERGENCY LIGHT AT SEAT 9D LENSE COVER. REPLACED LIGHT ASSY. LIGHT OP CHKS OK.SDR UALA2009122203964Controller · faultyPASSENGER ADDRESS STATUS MESSAGE ON EICAS. REPLACED PASSENGER ADDRESS CONTROLLER AND CABIN SYS MANAGEMENT UNIT, RESET ACFT. OP CHKS NORMAL.SDR UALA2009122203973Display · inoperativeSATCOM SYS STATUS MSG. RESET NO HELP. REPLACED SDU. BITE TEST OK.SDR UALA2009122203975Valve · faultedRT WING ANTI-ICE (WAI) VALVE FAILURE. FOUND WAI VALVE AT FAULT. REPLACED VALVE AND OPS CHECKS OK.SDR UALA2009122103956Fan Blade · damagedPOSSIBLE BIRDSTRIKE TO NR 1 ENG. ACCOMPLISHED BORESCOPE INSP. HPC 5TH, 6TH, AND 10TH STAGE BLADES AND GAS PATH NO DAMAGE FOUND. BIRD STRIKE DAMAGE FOUND ON NR 1 FAN BLADE. HAS 3 DENTS ON CONVEX SIDE AT MIDSPAN 15 IN FROM BLADE ROOT. REPLACED NR 1 BLADE INDSDR UALA2009122103943Line · brokenMANIFOLD AY-SENSING PT4.95 LINE BROKEN AT 6 O'CLOCK POSITION. REPLACED SENSE LINE. ACP'D ENGINE RUN AND TEST AS REQUIRED. ALL INDICATIONS NORMAL.SDR UALA2009122103932Module · faultySTDBY ALTIMETER AND STDBY AIRSPEED PROBLEM. A-S INDICATOR BLANKS OUT IN BOTH POSITIONS A-S POSITION AND ALSO IN ALTITUDE POSITION. BAD A-S INDICATOR. FLUSHED CENTER STATIC STBY. ACP WIRING CHECKS AND RINGOUTS. ACP LEFT PSA REPLACEMENT FOR STBY ATTITUDE FLUCTUSDR UALA2009122203961Hinge · damagedDOOR FOR 02 MASKS AT SEATS 34 CDEFG HAS BROKEN HINGES. DOOR IS SECURED CLOSED. NEED TO REPLACE BOX ASSY. REPLACED BOX ASSY AND PERFORMED DROP TEST. OP CHKS GOOD.SDR UALA2009122103930Line · looseR WING ANTI-ICE FAULT, FLT DIVERTED. REPLACED ENG ANTI ICE VALVE AND CONTROLLER (P/N 810503-7 (S/N 162). NO HELP, FOUND LOOSE LINE. SECURED LOOSE MUSCLE LINE. SYS OPS TEST GOOD. ACFT GOOD FOR SVC.SDR UALA2009122103952Line · leakingWASTE TANK RINSE LINE FOR CTR TANK HAS A LEAK JUST PAST THE SERVICE PANEL. BEST TO ACCESS FROM REAR MANUAL PIT ACCESS PANEL ON FLOOR. LEAK IS 2 INCHES PAST EXTERIOR SERVICE PANEL. LAV TANK RINSE LINES REQUIRE RPLCMENT. NO PARTS ORD. REPLACED THE FWD AND AFSDR UALA2009121703909Controller · malfunctionedPRE-DEPT FOUND STATUS MSG 'CABIN TEMP CONTROLLER LT'.TRIED TO RESET CB AND RACK CTC L, NO HELP. POWER DOWN, ALSO NO HELP. REPLACED CABIN TEMP CONTROLLER. MAT GROUND TEST PASS. REINSTALLED OPS AND OPC SOFTWARE, CKD OK.SDR UALA2009121603900Line · leakingCTR HYD SYS FAILED AFTER LOWERING GEAR. PRESSURE LESS THAN 1200 PSI. RESERVOIR (CENTER) FLUID QUANTITY IS LOW. FOUND NOSE GEAR STEERING HYD HOSE RUPTURED. RPL HOSE. REPLENISHED CTR HYD SYSTEM. LEAK CHK SATISFACTORY. A-C RELEASED FOR SERVICE.SDR UALA2009121603893Fcu · malfunctionedCREW REPORTS STATUS MSG PFC INTERFACE AND FLAP SLAT CONTROL MSG 1. FOUND FSEU 1 BAD, NO PARTS AND OK TO DF. REPLACED FSEU 1, NO HELP. RE-INSTALLED ORIGINAL ONE BACK, WHEN DOING OPS CHK IT FAULTS MSG 27-20271 (FSEU 1 SENSOR EXCITATION IS LOW). NEEDS MORE TIME SDR UALA2009121803912Transmitter · malfunctionedOIL QUANTITY (ENG) - LOW. LT ENG OIL QTY BELOW LIMIT. VISUALLY CONFIRMED LT OIL QTY FULL. MASTER CHIP DET CHECKED NO CONTAMINATION NOTED, OIL CONSUMPTION AVG 0042, NO ENG OIL LEAK NOTED, IND AT COCKPIT 13QT. CLEANED CONNECTOR, NO HELP. 25 QTS INDICATED BEFOSDR UALA2009121603894Controller · faultyBLEED PRSOV R RT ENG BLEED PRESSURE REGULATING SHUTOFF VALVE (PRSOV) FAILED OPEN OR CLOSED OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG-3610380 LATCHD ER MODE REMOVED AND REPLACE THE FOLLOWING NR 2 ENG PRSOV, PRSOV CONTROLLER AND HPSOV. SDR UALA2009121503884Valve · malfunctionedAPU BLEED AIR MSG. REPLACED SURGE VALVE. OPS NORMAL.SDR UALA2009121403855Latch · damagedAFT LAV SVC PANEL LH AFT LATCH DAMAGED. REPLACED DAMAGED LATCH ON LAV SERVICE PANEL.SDR UALA2009121503882Acm · faultyON APPROACH, STATUS MSG PACK ACM R. CONFIRMED ACM FAILURE. NEEDS ACM. REPLACED SEIZED ACM, OPS CHECK GOOD. ALSO FOUND LOW LIMIT VALVE BUTTERFLY DISK NOT CLOSING. REPLACED IAW MM, NO HELP. ALSO CHECKED RAM AIR INLET FOR BLOCKAGE IT WAS CLEAN. REPLACED ECONOMSDR UALA2009121403853Duct · unsecureDURING ENG START APU BLEED VALVE APPEARS TO MAKE NOISE HEARD AT DOOR 3&4. OPENED ACCESS TO LT F/A CREW REST AREA, LT SIDE OF AFT CARGO PIT, MAIN GEAR DOORS, AND APU AREA. INSPECTED ALL DUCTS FROM MLG BULKHEAD TO APU. FOUND LOOSE DUCT AT EXHAUST DUCT ADP1, SECSDR UALA2009120903803Light · inoperativeSEAT 1F AFT EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSY, OPS CHECK OKAY.SDR UALA2009120903810Sensor · failedHEAT TAT FAILURE OF TOTAL AIR TEMPERATURE (TAT) PROBE HEATING CIRCUIT. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; TAT PROBE HEATER POWER IS NOT AVAILABLE. DB- ELMS P110 ELECTRONICS UNIT MSG-3037120 LATCHED CL MODE. REPLACED TAT PROBE AND PERFORMED MAT TEST. SDR UALA2009120803800Eec · malfunctionedRIGHT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYSTEM IS OPERATING WITH REDUCED REDUNDANCY. REPLACED NR 2 EEC. RAN ENGINE, CK'D NORMAL. NO MESSAGES.SDR UALA2009120803797A/C Pack · failedRIGHT PACK TRIM AIR PRSOV STATUS MSG 21-24202 APPEARED WHILE TESTING RT PACK PROBLEM. WHILE TROUBLE SHOOTING RT PACK FAILED 21-51T816 WITH MSG 21-24202,WITH MANY HIS AT TAXI. REPLACED R TRIM AIR PRSOV. GRD TEST AGAIN PASS, NO EXISTING FAULT.SDR UALA2009120803795Light · inoperativeSIDEWALL LIGHT AT SEAT 41H INOPERATIVE. REPLACED LAMP, CKS OKAY.SDR UALA2009120803794Lamp · inoperativeAFT EMERGENCY LIGHT AT SEAT 2E INOPERATIVE. REPLACED AFT EMERGENCY LIGHT ON SEAT 2E. CHECKS GOOD.SDR UALA2009120703783Heat Exchanger · crackedRT PACK OVERHEAT. REPLACED INLET CONDITION TEMP SENSOR, NO HELP. WHILE REPLACING FLOW CONTROL VALVE AMT FOUND HEAT EXCHANGER WITH AN 8" CRACK, REPLACED HEAT EXCHANGER, NO LEAKS DETECTED.SDR UALA2009120803799Relay · malfunctionedON SHUTDOWN HAD ENG FUEL VALVE RT EICAS MSG. ENG SHUTDOWN BUT VALVE INDICATES NOT. HAS HISTORY. REPLACED RT ENG RELAY UNIT (ERU). OPERATIONAL CK ON ENGINE RUN & ENG SHUT DOWN -- NO EICAS MSG'S & FUEL VLVS SHOW NORMAL OPEN-CLOSE POS ON FUEL PAGE SYNOPTICS.SDR UALA2009120803798Controller · malfunctionedAPU STATUS MESSAGE. REPLACED APUC. OPS CKS NORMAL. NO MORE MESSAGES.
Back to Boeing 777-222