SDR UALA2008112006583Light · brokenSEAT 1F EMERGENCY LIGHT BROKEN. REPLACED LIGHT ASSY & CHECKS OKAY.SDR UALA2008112006573Light · inoperativeEMERGENCY LIGHTS INOP AT SEATS 22C AND 39C.SDR UALA2008112006572Oven · odorCREW REPORTS AFTER DESCENT AND LEVEL AT APPROX 12K FT, SMELLED A BURNING ELECTRIC ODOR WHICH DISSIPATED AFTER A FEW MINUTES. CONTINUED APPROACH AND GEAR WAS SELECTED DOWN AND POWER INCREASED THE ODOR RETURNED UNTIL LANDING. CREW ALSO STATES THAT ODOR WAS ONLSDR UALA2008112406615Battery · faultySTATUS MSG BATTERY CHARGER MAIN. REPLACED MAIN BATTERY CHARGER AND BATTERY, NO HELP. SWAPPED APU BATTERY WITH MAIN BATTERY AND CHECKS OKAY.SDR UALA2008112106605Cylinder · low pressureINFLATION CYLINDER OUT OF GREEN BAND. IMPROPER CYLINDER FILL. TOP OFF CYLINDER.SDR UALA2008112006575Light · inoperativeSEAT 2E REAR EEL LIGHT STRIP INOP.SDR UALA2008112106604Valve · malfunctionedNO WATER PRESSURE THROUGHOUT ACFT. FLIGHT DIVERTED. REPLACED PRESELECT OVERFLOW (V38102) ON ACCOUNT NOT FULLY CLOSING. WATER SYS PRESS CHECKS NORMAL.SDR UALA2008111806548Oil Filter · cloggedAPU APUC DETECTED FAULT THAT WOULD CAUSE AUTOMATIC SHUTDOWN OF APU IN UNATTENDED MODE OPERATION, OR COMPLETE LOSS OF APUC BUS ACTIVITY (BOTH L AND R 629) FOR 3 SECONDS AFTER THE APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TEN SECONDS. STATUS MSGSDR UALA2008111806547Igniter · inoperativeL ENG IGNITOR 1 INOPERATIVE.SDR UALA2008111706536Connector · unsecureSEAT 1E BOTH EEL LIGHTS INOP. SECURED CONNECTOR, CHECKS OK.SDR UALA2008111706535Smoke Detector · faultyALL TEST FAULTED OUTBOARD FWD LAV SMOKE DETECTOR. REPLACED SMOKE DETECTOR. OPS CHECK GOOD.SDR UALA2008111706534Light · inoperativeEEL LIGHT ON SEAT 13G FWD LIGHT INOP. RELAMPED, OPS CHECK OKAY.SDR UALA2008111706519Light · inoperativeEXTERIOR EMERGENCY LIGHTS ON DOORS 3 AND 4 LT INOP. RELAMPED EMERGENCY LIGHTS ON DOORS 3 AND 4 LEFT, OPS CHECK OK.SDR UALA2008111706518Connector · not seatedAFT EEL LIGHT ON SEAT 3E INOP. RESEATED CONNECTOR, OPS CHECK OK.SDR UALA2008111406507Scavenge Pump · faultyRIGHT ENG TOOK 10 QUARTS OF OIL ON ARRIVAL. BORO'D NR 3 WEEP TUBE FOUND CLN, NO OIL. HOC ON RIGHT ENG. REPLACED SCAVENGE PUMP. REPLENISHED OIL TANK TO FULL. ACCOMPLISHED ENGINE RUN. ENGINE OIL PRESSURE WITHIN LIMITS. NO LEAKS NOTED ON ENG RUN.SDR 2008UALA06507Oil System · lowRIGHT ENG TOOK 10 QUARTS OF OIL ON ARRIVAL. BOROSCOPED NR 3 WEEP TUBE, FOUND CLEAN NO OIL.SDR UALA2008111306499Wire Harness · faultyNR 2 ENG IDG WILL NOT DISCONNECT. SWAPPED NR 1 AND NR 2 IDG DISCONNECT SWITCH ON OVERHEAD, NO HELP. REMOVED ALL IDG ELECTRICAL CONNECTORS, NO BENT PINS OR DEFECTS NOTED. SUSPECT BAD IDG FROM STOCK. NEW IDG ON ORDER. REPLACED IDG, NO HELP. GCU BITE TEST OSDR 2008UALA06499Wire Harness · shortedNR 2 ENG IDG WILL NOT DISCONNECT. SWAPPED NR 1 AND NR 2 IDG DISCONNECT SWITCH ON OVERHEAD, NO HELP. REMOVED ALL IDG ELECTRICAL CONNECTORS, NO BENT PINS OR DEFECTS NOTED. SUSPECT BAD IDG FROM STOCK. NEW IDG ON ORDER. REPLACED IDG PER MM 24-11-01-401, NO HESDR 2008UALA06512Light · looseTHE 2E EXIT PATH LIGHT ON SEAT IS FALLING OFF. SECURED LIGHT ASSY, CHECKED OKAY.SDR 2008UALA06489Light · inoperativeSEAT 32E EEL LIGHT INOP. REPLACED LIGHT ASSY, OPS TEST GOOD.SDR 2008UALA06449Connector · looseEEL LIGHTS ON SEATS 41C&G, 42C&G, 43C&G ARE INOPERATIVE DURING TEST OF LIGHTING. CONNECTED LOOSE CONNECTOR, CHECKS OKAY.SDR 2008UALA06435Light · inoperativeSEATS 1E AFT, 2E BOTH AND 1F FWD EEL LIGHTS INOP. REPAIRED 1E AND 1F. CURRENTLY 2E EEL LIGHTS STILL INOP. NEED INVERTER LOCATED ON 3E STOWAGE BOX.SDR 2008UALA06434Light · missingAFT EEL STRIP MISSING AT SEAT 3F. REPLACED EEL ASSY AND CHECKED OKAY.SDR UALA2008111306469Relay · faultyHEAT PITOT C MSG AFTER START. STATUS MSG - HEAT PITOT C - MAINT MSG 30-3612. REPLACED PROBE HEAT SENSOR RELAY. CHECKED OPS OK. NO STATUS MSG ON EICAS.SDR 2008UALA06484Oxygen System · malfunctionedF/O OXYGEN MASK TEST DOES NOT TEST. REPLACED O2 BOX. OPS OKAY, LEAK CHECKED GOOD.SDR 2008UALA06469Relay · failedHEAT PITOT C MSG AFTER START. STATUS MSG - HEAT PITOT C - MAINT MSG 30-36122. REPLACED PROBE HEAT SENSOR RELAY. CHECKED OPS OKAY. NO STATUS MSG ON EICAS.
SDR 2008UALA06426Circuit Card · faultyANTI-ICE WING EICAS MESSAGE. REPLACED ACIPS CARD. OPS GOOD.SDR UALA2008111306387Filter · dirtyALL FLIGHT ATTENDANTS FROM BUSS CLASS AFT REPORT STALE STUFFY AIR QUALITY SAMC TEXT: FLT CREW REPORTED MORE THAN 10 F/A'S FELL ILL WITH EFFECTS OF DIZZINESS AND LIGHTHEADED. ONE FLT CREW FELT SAME EFFECTS WHEN TRAVELED TO BACK OF CABIN. F/A'S FROM MID CABINSDR UALA2008111306414Hydraulic Line · leakingRIGHT MLG WHEEL WELL HYD LEAK. FOUND TUBING THAT IS LEAKING. REMOVED LEAKING HYDRAULIC LINE FROM AIRCRAFT AND ROUTED TO TUBE SHOP FOR MANUFACTURING OF NEW LINE. NEW LINE WILL BE READY AROUND 2100. INSTALLED NEW DOOR LOCK LOWER HYD LINE FROM ACTUATOR TO TEESDR 2008UALA06415Pressure Switch · failedENGINE OIL FILTER SENSOR L THE PRESSURE SWITCH FOR DETECTING IMPENDING OIL FILTER BYPASS ON THE LEFT ENGINE HAS FAILED. STATUS MSG-7960861 ACTIVE ERROR MODE MSG-7960861 ACTIVE ER MODE. ACPD LEFT ENG OIL TANK MASTER CHIP DETECTOR FOR CONTAMINATION. CHIP DETESDR 2008UALA06414Hydraulic Line · leakingRT MLG WHEEL WELL HYD LEAK. FOUND TUBING THAT IS LEAKING. REMOVED LEAKING HYDRAULIC LINE FROM AIRCRAFT AND ROUTED TO TUBE SHOP FOR MANUFACTURING OF NEW LINE. NEW LINE WILL BE READY AROUND 2100. INSTALLED NEW DOOR LOCK LOWER HYD LINE FROM ACTUATOR TO TEE FISDR 2008UALA06387Filter · unknownALL FLIGHT ATTENDANTS FROM BUS CLASS AFT REPORT STALE STUFFY AIR QUALITY. FLT CREW REPORTED MORE THAN 10 F/A'S FELL ILL WITH EFFECTS OF DIZZINESS AND LIGHTHEADED. ONE FLT CREW FELT SAME EFFECTS WHEN TRAVELING TO BACK OF CABIN. F/A'S FROM MID CABIN FELT ILL SDR 2008UALA06386Duct · wornAPU PRESSURE DUCT FOUND WORN BEYOND LIMITS, BY CONTACT WITH STRUCTURE CUTOUT AT STA 2360 FRAME. REMOVED DUCT, WELD REPAIRED. REINSTALLED AND LEAK CHECKED. REPLACED SUPPORT NYLON SLEEVE.SDR 2008UALA06411Shutoff Valve · faultyWITH RIGHT ENGINE BLEED SELECTED DO NOT GET GREEN BAR ON AIR PAGE TO OPERATE PACKS. PRSOV VALVE OPENS ONLY. STATUS MESSAGE R PRSOV BLEED. MAT MESSAGE 36-10380. FOUND R PRSOV MUSCLE LINE GALLED. REPLACED R PRSOV AND R PRSOV CONTROLLER. ENGINE RUN RIGHT BLESDR 2008UALA06371Light · inoperativeSEAT 3E AFT EMERGENCY LIGHT INOP. LIGHT CHECKS OKAY.
SDR 2008UALA06358Fan · odorODOR OF SMOKE IN COCKPIT. FOUND FAN BEARING BAD ALSO BLACK SMOKE AT FAN BLADES. REPLACED EQ COOLING FAN.
SDR UALA2008111306361Controller · faultyAPU BLEED AIR APUC DETECTED LOSS OF ABILITY TO PNEUMATICALLY LOAD APU. MESSAGE IS TRIGGERED BY IGV OR SURGE CONTROL SYSTEM FAULTS. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; SURGE CONTROL VALVE (PNEUMATIC CLUSTER) DOES NOT FOLLOW COMMAND. DB- ASDR 2008UALA06364Lamp · inoperativeEMERGENCY ESCAPE PATH LIGHTS AT SEAT 1F AFT AND 3E FWD ARE INOP OR MISSING. REPLACED EMERGENCY LIGHT ASSY. OPS NORMAL.SDR 2008UALA06361Controller · faultyAPU BLEED AIR APUC DETECTED LOSS OF ABILITY TO PNEUMATICALLY LOAD APU. MESSAGE IS TRIGGERED BY IGV OR SURGE CONTROL SYSTEM FAULTS. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; SURGE CONTROL VALVE (PNEUMATIC CLUSTER) DOES NOT FOLLOW COMMAND. DB- APUSDR UALA2008111306339Light · looseEEL STRIP AT SEAT 2E IS LOOSE WITH WIRES SHOWING. SECURED LIGHT, CHECKS GOOD.SDR 2008UALA06339Light · looseEEL STRIP AT SEAT 2E IS LOOSE WITH WIRES SHOWING. SECURED LIGHT, CHECKS GOOD.SDR 2008UALA06338Lamp · looseEMERGENCY EVAC LIGHT ON SEAT 1E DANGLING LOOSE. REPLACED LAMP, OPS NORMAL.SDR UALA2008112006574Relay · faultyNO LAND 3 DEGRADATION IN AUTOLAND SYS PRIOR TO APPROACH (BEFORE LAND 3 AUTOLAND STATUS ANNUNCIATION). AUTOLAND SYS IS NO LONGER FAIL-OPERATIONAL. ADVISORY MSG01- ACTIVE CRUISE MODE DEPENDENT; BUS ISOLATION IS NOT AVAILABLE. DB- AUTOPILOT FLIGHT DIRECTOR COMPUSDR UALA2008111306307Regulator · blockedLOSS OF ALL WATER PRESSURE. FLIGHT DIVERTED. FOUND BLEED AIR PRESSURE REGULATOR BLOCKED. CLEANED AND NOW WATER PRESSURE TO LAV AND GALLEY NORMAL.SDR 2008UALA06310Pump · failedFUEL PUMP R FWD RIGHT FORWARD (BOOST) FUEL PUMP SWITCH ON AND PUMP OUTPUT PRESSURE LOW. STATUS MSG01- ACTIVE CLIMB MODE DEPENDENT; RELAY (R FWD FUEL BST PMP SWITCH) IN P110 IS NOT IN COMMANDED POSITION. DB- ELMS P110 ELECTRONICS UNIT MSG-2811007 ACTIVE CL MOSDR 2008UALA06307Water System · malfunctionedLOSS OF ALL WATER PRESSURE. FLIGHT DIVERTED.SDR 2008UALA06299Electrical Sys · malfunctionedFLIGHT REPORTED ELECTRICAL PROBLEM. FLIGHT DIVERTED.SDR 2008UALA06288Battery · inoperativeF/A FLASHLIGHT IN FWD GALLEY AREA INOP. REPLACED FLASHLIGHT AND BATTERY, OPS OK. REPLACED SEAL.SDR 2008UALA06296Battery · faultyAPU BATTERY AND APU CHARGER STATUS MESSAGE. REPLACED APU BATTERY & CHARGER. OP CHECKS NORMAL.SDR 2008UALA06231Light · missingEEL LIGHT MISSING ON SEAT 1E. DISCOVERED LIGHT MISSING. REPLACED MISSING EEL LIGHT ASSEMBLY, TESTS GOOD.