SDR 2008UALA05847Angle · damaged2 ANGLE SIDE PANELS AT STA 1600 DAMAGED. REPLACED SIDE PANELS AT STA 1600 AS REQUIRED.SDR 2008UALA05843Line · damagedHYDRAULIC PRESSURE PROBLEM, RTFL. FOUND CENTER HYD SYSTEM RETURN LINE AT STA 16 DAMAGED IN AFT CARGO PIT FROM APU BLEED AIR DUCT FAILURE. REPAIRED HYD LINE AT STA 16 IN AFT PIT. LEAK CK GOOD.SDR 2008UALA05841Cover · damagedEMERGENCY LIGHT DAMAGED AT SEAT 9D. REPLACED LIGHT COVER AT 9D. OPS CHECK OK.SDR UALA2008111305837Oil Cooler · faultyL ENG OIL QTY INDICATION DROPPING INDICATED 2QTS WITH TEMP RISING. CREW REPORT. RPLD AIR COOLED OIL COOLER. RUN, OPS LEAK CK OK.SDR 2008UALA05837Oil Cooler · malfunctionedL ENG OIL QTY INDICATION DROPPING INDICATED 2 QTS WITH TEMPERATURE RISING, CREW REPORT. REPLACED AIR COOLED OIL COOLER. RUN, OPS LEAK CHECK OK.
SDR 2008UALA05809Valve · inoperativeANTI ICE ENG R -EICAS STATUS MESSAGE. RT ANTI-ICE VALVE FAILED. REPLACED VALVE. OPS CHECKS OKAY.SDR 2008UALA05825Light · unsecureSEAT 1E EMERGENCY LIGHT FELL OFF, CREW TAPED COVER AT FC GALLEY WALL. FOUND LIGHT OUT OF POSITION. SECURED ASSEMBLY. OP CHECKS NORMAL.SDR 2008UALA05804Wire · damagedWHILE RETRACTING FLAPS DURING TESTING OF CALLOUT AM6818 SKEW SENSOR R8A BLANKS TO ZERO ON EICAS. FLAP POS 1 TO 5 AND AGAIN FROM 5 TO 15. FOUND WIRE 8478-2003B DAMAGED NEAR DM27324 SNSR 7A. REPAIRED REF GNMM 2-0-15. FSEU SYSTEM TEST OK.
SDR 2008UALA05800Engine · failedAPU EMITS SMOKE FROM TAIL PIPE. OIL QTY RAPIDLY DROPPED TO ZERO. TURBINE BLADE TIP DAMAGE ON OLD APU. REPLACED APU. OPS NORMAL.SDR 2008UALA05789Seal · leakingNR 2 ENG HAS EVIDENCE OF OIL LEAK ON CORE COWL. RAN ENG AND FOUND BACK UP GEN DRIVE DRAIN TUBE LEAKING. REPLACED BACK UP GEN DRIVE SEAL. REPLACED BUG.SDR 2008UALA05780Battery · faultyAPU BATTERY VOLTAGE TO LOW TO START THE APU. CAN BE STARTED PNEUMATICALLY. RESET CIRCUIT BREAKER P320 K12, CHARGER OPERATES NORMAL. BATTERY CHARGED AND APU START NORMAL.SDR 2008UALA05773Lamp · inoperativeEMERGENCY LIGHT INOP 2E. RESECURED LOOSE CONNECTOR. RELAMPED EEL STRIP AT 2E BATH LIGHTS. OPS NORMAL.SDR 2008UALA05750Fan · damagedCABIN AND FLIGHT DECK TEMP PROBLEMS. FOUND RT LAV GALLEY VENTILATION FAN HAD NO BLADES. REPLACED RT LAV GALLEY VENTILATION FAN. OP CHECKS NORMAL.
SDR UALA2008111305786Probe · faultyRECEIVED UNBALANCED FUEL EICAS TWICE WITH FAULTY R FUEL QUANTITY. REPLACED LEFT CTR TANK PROBE NR 2.SDR 2008UALA05786Indication Sys · malfunctionedGOT UNBALANCED FUEL EICAS TWICE WITH FAULTY R FUEL QUANTITY.SDR 2008UALA05739Connector · disconnectedEMERGENCY LIGHT AT SEAT 2F AFT LIGHT WILL NOT WORK. FOUND UNPLUGGED. RECONNECTED. OP CHECKS OKAY.SDR 2008UALA05738Light · inoperativeEMERGENCY LIGHT IN AFT GALLEY FLOOR LEVEL LT SIDE WILL NOT WORK. FOUND DEFECTIVE LAMP. REPLACED LAMP. TESTS OKAY.SDR 2008UALA05737Light · inoperativeEMERGENCY CEILING LIGHT IN AFT GALLEY WILL NOT WORK. LIGHT FOUND INOP. REPLACED LAMP. TESTS OKAY.SDR 2008UALA05736Cable · disconnectedEMERGENCY LIGHT AT SEAT 38C WILL NOT WORK. FOUND CABLE DISCONNECTED. RE-SECURED CABLE. TESTS OKAY.SDR 2008UALA05735Light · inoperativeEMERGENCY LIGHT AT SEAT 25C WILL NOT WORK. LIGHT FOUND INOP. REPLACED LAMP. OP CHECKS OKAY.SDR 2008UALA05693Control Valve · failedNR 1 SLATS PRIMARY FAIL UPPER EICAS. *S/D* SLAT PRIMARY CONTROL VALVE FAILURE. REPLACED SLAT PRIMARY CONTROL VALVE & SVC'D CENTER HYD RESERVOIR. A/C OK FOR SERVICE.SDR 2008UALA05691Generator · faultedLEFT BACK UP GENERATOR BLOCKED FILTER MSG ON SYNOPTIC PAGE. *S/D* FOUND GENERATOR FAULTY. REPLACED NR 1 ENGINE BACK UP GENERATOR. ALL OPS NORMAL.SDR 2008UALA05732Coffeemaker · defectiveSMOKE AND ELECTRICAL SMELL IN FORWARD GALLEY. DEFECT FOUND IN COFFEEMAKER. REPLACED COFFEEMAKER. NO STRUCTURAL DAMAGE TO GALLEY. SYSTEM OP CHECKS OKAY.
SDR 2008UALA05678Generator · leakingRIGHT BACK UP GENERATOR OFF OR FAILED. RIGHT BUG WILL NOT HOLD OIL LEAKING ON ENG RUN. NR 2 ENGINE BUG FOUND UNDERSERVICED. SERVICED UNIT RAN ENGINE, WITHIN 2 MINUTES OIL COULD BE SEEN EVACUATING FROM OVERFILL DRAIN. REMOVED BUG. INSTALLED REPLACEMENT BACSDR 2008UALA05686Light · missingSEAT 2E MISSING FLOOR PROX EMERGENCY PATH MARKING LIGHT. DISCOVERED LIGHT MISSING. NEW LIGHT ASSY INSTALLED. OK FOR SERVICE.SDR 2008UALA05647Bleed Air Sys · inoperativeAPU BLEED AIR SYSTEM INOP. OIL FOUND IN APU INLET PLENUM ASSY. REPLACED APU ASSY. REPLACED IGV ACTUATOR. OPS NORMAL
SDR 2008UALA05634Lamp · brokenEMERGENCY LIGHT BROKEN AT SEAT 39G. DISCOVERED BROKEN LAMP. REPLACED LAMP. OPS CHECK GOOD.SDR 2008UALA05607Idg · faultyELEC BACKUP GEN L DISPLAYED ON EICAS AND STATUS PAGE. FOUND FAULTY BUG. REPLACED LEFT BACKUP GENERATOR. OK FOR SERVICE.SDR 2008UALA05628Charger · inoperativeSTATUS MESSAGE APU. APU BATTERY AND CHARGER INOP, NEEDS REPLACEMENT. CHARGER NOT CHARGING. FOUND APU BATTERY & CHARGER INOP. REPLACED APU BATTERY & APU BATTERY CHARGER. OPS CHECK NORMAL.SDR 2008UALA05666Idg · faultyRIGHT IDG HAS BLOCKED MESSAGE ON EICAS CHAPTER 24 MAINTENANCE PAGE. IDG FOUND FAULTY. REPLACED IDG. OP CHECK & LEAK CHECK GOOD. RESERVICED RT IDG. OK FOR SERVICE.SDR 2008UALA05644Starter · inoperativeNR 1 ENG STARTER INOP. FOUND STARTER INOP. REPLACED STARTER. ENG DRY MOTOR & LEAK CHECKED NORMAL. OK FOR SERVICE.
SDR UALA2008111305610Thermocouple · faultyRIGHT ENG 2.9 STAB BLEED VALVE TC PROBE CHANNEL B SIGNAL OUT OF RANGE. REPLACED NR 2 ENG EEC PER MM 73-21-04. NO HELP CORRECTING PROBLEM. EEC OP CHECKS NORMAL. INSTALLED NEW GOOD PROBE IN 'B' POSITION, CHECKS OK.SDR 2008UALA05649Skin · dentedBS 633-641 BETWEEN S27-28L MATERIAL REMOVED AND DENT IN SKIN AND IN SHEAR TIE BEYOND SRM LIMITS. INSTALLED DOUBLER REPAIR.SDR 2008UALA05612Light · inoperativeSEAT 2E EMERGENCY LIGHT INOP WHEN TESTED. FOUND LIGHTS INOP. REPLACED BOTH EMERGENCY LIGHTS AT SEAT 2E. BOTH OP CHECK GOOD.
SDR 2008UALA05610Probe · out of toleranceRIGHT ENG 2.9 STAB BLEED VALVE TC PROBE CHANNEL-B SIGNAL OUT OF RANGE.SDR UALA2008111305595Duct · damagedNR 1 ENGINE HPT DAMAGE. REPLACED NR 1 ENGINE. SHOP TEARDOWN FOUND A MISSING HP TURBINE STAGE-2 DUCT SEGMENT. ADJACENT SEGMENTS HAD FOREIGN MATERIAL LODGED IN THE INTERNAL COOLING PASSAGES THAT CHOKED OFF COOLING AIR. THIS CAUSED BOWING, WHICH LEAD TO HEAVYSDR 2008UALA05609Light · missingSEAT 1F MISSING AFT EMERGENCY PATH EXIT LIGHT ASSY. REPLACED LIGHT ASSY, OPS NORMAL.
SDR 2008UALA05595Turbine · damagedNR 1 ENGINE HPT DAMAGE.SDR 2008UALA05594Light · missingEEL 1F MISSING 2F HANGING LOOSE. LIGHT MISSING. REPLACED EMERGENCY LIGHT AT SEAT 1F.SDR UALA2008111305581Bearing · failedNR 2 ENGINE IFSD. FLIGHT DIVERTED. REPLACED ENGINE PRIOR TO FURTHER FLIGHT. SHOP TEARDOWN REVEALED THAT THE MAIN GEARBOX (MGB) HAD A FAILURE OF THE MB7 BEARING, THE MB8 BEARING, AND DRIVESHAFT ASSEMBLY. ROOT CAUSE FOR THIS FAILURE, AND CORRECTIVE ACTION, ASDR UALA2008111305578Smoke Detector · faultyCHANNEL 1 E-E SMOKE DETECTOR EICAS MESSAGE. REPLACED E-E COOLING SMOKE DETECTOR.SDR 2008UALA05584Controller · malfunctionedSTRONG ODOR IN CABIN. SUSPECT FAULTY CONTROLLER. REPLACED LEFT CABIN TEMPERATURE CONTROLLER. CHECKS OKAY & NO ODOR ON DEPARTURE.SDR 2008UALA05580Light · missingAFT EMERGENCY LIGHT AT SEAT 1E MISSING. REPLACED EMERGENCY LIGHT. OPS NORMAL.SDR 2008UALA05579Light · brokenAFT EMERGENCY LIGHT AT SEAT 1F BROKEN. REPLACED EMERGENCY LIGHT ASSY. OK FOR SERVICE.SDR 2008UALA05578Smoke Detector · faultyCHANNEL 1 E&E SMOKE DETECTOR EICAS MESSAGE.SDR UALA2008111305554Sensor · faultyEQUIP COOLING CTRL R RIGHT ECC REPORTS FAILED FOR 10 SECONDS AND POWER IS AVAILABLE FOR THE ECC. STATUS MSG-2117112 INACTV ER MODE MSG-2117112 LATCHED ER MODE MSG-2117132 LATCHED ER HARD. SUSPECT LOW FLOW SENSOR. REPLACED LOW FLOW SENSOR, OP CHECK GOOD. ACSDR 2008UALA05554Sensor · failedEQUIP COOLING CTRL R RIGHT ECC REPORTS FAILED FOR 10 SECONDS AND POWER IS AVAILABLE FOR THE ECC. STATUS MSG-2117112 INACTV ER MODE, MSG-2117112 LATCHD ER MODE, MSG-2117132 LATCHED ER HARD.SDR 2008UALA05543Lamp · inoperativeSEAT 9F FWD EEL PROX LIGHT INOP. LIGHT FOUND DEFECTIVE. REPLACED LAMP. OPS CHK GOOD.SDR 2008UALA05542Light · inoperativeSEAT 8F AFT EEL PROX LIGHT INOP. FOUND LIGHT INOP. REPLACED LIGHT ASSY. OPS CHECKED GOOD.
SDR 2008UALA05541Light · inoperativeSEAT 3F HAS BOTH FWD AND AFT EEL PROXS LIGHTS INOP. FOUND FAULTY HARNESS. REPLACED SEAT EEL LIGHT HARNESS. OP CHKS OKAY.