SDR 2008UALA01003Toilet · leakingFLIGHT DIVERTED DUE TO WATER LEAK/OVERFLOW FROM DOOR 3 LAVATORY COMPLEX. FOUND FAULTY WATER VALVE. REPLACED TOILET. TEST SYSTEM OPS NORMAL NO LEAKS. ACFT OK FOR SERVICE.SDR 2008UALA01023Skin · dentedA DENT WAS FOUND ON FUSELAGE SKIN AT STA 667, BETWEEN STR 26L AND 27L. DENT IS 4" X 5". CUT OUT DENT AND ACP HEFC INSP FOR DAMAGE FREE. ACP OPEN HOLE HFEC INSP FOR FASTENER HOLES. INSTALLED DOUBLER REPAIR. THE REPAIR IS CAT B REQUIRES FUTURE REINSPECTION AFSDR 2008UALA01004Bearing · failedFOUND EXCESSIVE BLACK METAL COVERING CHIP DETECTOR HEAD, AT NR 2 ENG MAIN OIL TANK (MCD). FOUND GEARBOX (MCD) FULL OF METAL CONTAMINATION. ENGINE REPLACED AT ORD. THE MB-7 AND MB-8 BEARINGS IN THE MAIN GEARBOX WERE FOUND TO HAVE FAILED. PRATT & WHITNEY HAS RSDR 2008UALA01001Hose · failedFLIGHT LANDED UNDER AMBER ALERT DUE TO A FAILED CENTER HYDRAULIC SYSTEM. NORMAL LANDING, BUT FLIGHT HAD TO BE TOWED TO GATE. FOUND FLEX HOSE TORN BY NOSE STEERING ACTUATOR. REPLACED HOSE. SERVICED HYD SYS. OP CHECKED OK. NO LEAK. ACFT OK FOR SERVICE.SDR 2008UALA01000Control Box · faultyFLIGHT CONTROL SYSTEM MESSAGE OCCURRED IN FLIGHT. PERFORMED EXTENSIVE TROUBLESHOOTING, & CHRONIC SYSTEM REVIEW. MANY UNITS PREVIOUSLY REPLACED BUT PROB NOT ENTIRELY CORRECTED. REPLACED POWER SUPPLY ASSY & ACE L-1 A SECOND TIME. ALL TESTS PERFORMED WITH GOOSDR 2008UALA01007Power Supply · dischargedDOOR 2R EMERGENCY SLIDE LIGHT INOP. REPLACED POWER SUPPLY.SDR 2008UALA01006Fuel Control · failedAPU NO START AT DISPATCH. FOUND FUEL& LUBE CLUSTER SHAFTS NOT TURNING. REPLACED FUEL CLUSTER. REPLACED LUBE CLUSTER. PENALTY RUN ACCOMPLISHED, FLITERS & OIL REPLACED, NO DISCREPANCIES FOUND AFTER RUNS. ACFT OK FOR SERVICE.SDR 2008UALA00987Light · inoperativeSEAT 3E EMERGENCY LIGHTS ARE INOP. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00986Light · missingSEAT 2E, AFT EMERGENCY LIGHT IS MISSING. REPLACED LIGHT.SDR 2008UALA00985Anti-Ice System · failedWINDOW HEAT LT SIDE FAILURE OF LT NR 2 SIDE WINDSHIELD HEATING CIRCUIT (LOSS OF WINDOW COATING, WIRING OR THE INDIVIDUAL WHCU CIRCUIT FOR THAT WINDOW). TESTED SYSTEM OPS NORMAL. ACFT OK FOR SERVICE.SDR UALA2008111300951Controller · faultyFUEL LEAK DETECTED FROM DRAIN MAST BETWEEN MLG DOORS. REPLACED SEALS ON ALL FIVE GAMMA COUPLINGS ON FWD TRANSFER TUBE IN CENTER TANK DRY BAY. REPLACED FUEL VALVE CONTROLLER, OPS AND LEAK CHECKED OK. REPLACED APU FUEL FEED LINE GAMMA COUPLING O-RINGS.SDR 2008UALA00983Seal · leakingFUEL LEAK RT WING UNDERSIDE OUTBOARD OF RT ENGINE PYLON. SUSPECT SEAL ON FUEL TANK ACCESS PLATE. REPLACED SEAL. ACFT OK FOR SERVICE.
SDR 2008UALA00951Fuel · leakingFUEL LEAK DETECTED FROM DRAIN MAST BETWEEN MLG DOORS.SDR 2008UALA00894Unknown · odorAFTER ENG START CREW REPORTED STRONG OIL ODOR ON FLT DECK. SUSPECT OIL LEAK FROM ENGINE OR APU. CHECKED APU & BOTH ENGINES. NO LEAKS OR OIL CONTAMINATION NOTED. NO ABNORMAL OIL CONSUMPTION NOTED. OK PER FIM 21-00 TASK 808. ACFT OK FOR SERVICE. NO REPEATSDR 2008UALA00893Control Unit · faultyANTISKID EICAS MSG ON TAXI. SUSPECT BRAKE SYSTEM CONTROL UNIT. REPLACED BRAKE SYSTEM CONTROL UNIT AS PER MM 32 -42-01, PASSED MAT TEST. AC OK FOR SERVICE.SDR 2008UALA00784Wire · sparksFAINT BURNING ODOR DETECTED FROM OVEN R31. NO ODOR WITH POWER OFF. INSIDE OF THE R31 OVEN WAS CLEAN. NO BURNING ODOR FROM OVEN. ONE ELECTRICAL TERMINAL IN THE CHILLER FOOD CART DOCK (COMPARTMENT 300) WAS BROKEN LOOSE. DAMAGE CAUSED SPARK AND BURNING ODOR. SDR 2008UALA00785Receptacle · malfunctionedTHE 12B LAPTOP POWER OUTLET SMOKED WHEN PLUGGED IN, PER F/A PASSENGER STOPPED USING IT. TESTED PLUG. NO SIGN OF BURNED PINS OR SMOKE DAMAGE. UNABLE TO DUPLICATE PROBLEM.SDR 2008UALA00772Filter · unknownFOUND RIGHT HAND ENG IDG FILTER BYPASS D, P, I POPPED OUT. REPLACED IDG PER MM 24-11-01. OPS. CHECK NORMALLY. SUSPECT IDG BEARING & SEAL DETERIORATION. COMPLETED VERIFICATION FLT & RT ENGINE IDG CHECKD GOOD FOR SERVICE.
SDR CA080903007Collar · cracked(CAN) FOUND DURING INSP, SEVERAL HI-LOCK COLLARS CRACKED. ALL HI-LOCK COLLARS REPLACED IAW SRM 51-40-02.SDR 2008UALA00795Light · inoperativeEMERGENCY EXIT LIGHTS ARE INOP AT SEATS 1F, 24C, 32G AND 39C. REPLACED LIGHT ASSEMBLY.
SDR 2008UALA00710Oil System · leakingRTFL DUE TO NR 1 OIL QUANTITY LOSS INDICATION. THE ENGINE'S ANGLE GEARBOX (AGB) WAS REPLACED AT HNL, AND THE AIRCRAFT RETURNED TO SERVICE. PROBLEM DID NOT RECUR. SHOP INVESTIGATION FOUND THAT THE AGB SNOUT PACKING (IPC 72-62-00-001-001) WAS WORN FLUSH WITH TSDR 2008UALA00704Lens · missingFOUND DOOR 4R AFT EMERGENCY EXIT LIGHT LENS COVER MISSING. REPLACED LENSSDR 2008UALA00773Lamp · inoperativeEEL LIGHTS INOP MID GALLEY RT SIDE. RELAMPED.SDR 2008UALA00711Filter · cloggedEQUIP COOLING EQUIPMENT COOLING FUNCTION IS INOPERATIVE (LOW FLOW), OR COOLING SUPPLY AIR TEMPERATURE IS EXCESSIVE ON THE GROUND, OR BOTH EQUIPMENT COOLING OVERRIDE VALVE ACTUATORS (NR 1 AND NR 2) HAVE FAILED BITE TEST OR HAVE FAILED TO REACH COMMANDED POSITIOSDR 2008UALA00706Lamp · inoperativeEEL LIGHTS INOPERATIVE MID GALLEY RT SIDE. RELAMPED.SDR 2008UALA00705Lamp · inoperative3L EXTERIOR MED EMERGENCY LIGHT INOP. SUSPECT FAULTY BULB. RELAMPED. OPS CHECKED OK. ACFT OK FOR SERVICE.SDR 2008UALA00643Bearing · failedRECEIVED A REPORT OF A FIRE IN VICINITY OF RT MAIN GEAR FROM CDG TOWER. ACFT DEPLANED IN TAXIWAY (ALL EIGHT SLIDES). NR 4 MLG (RT GEAR RT FRONT) OUTER WHEEL BEARING FAILED. NR 4 MLG (RT GEAR, RT FRONT) OUTER WHEEL BEARING FAILED. RT GEAR FWD AXLE IS HEAT SDR 2008UALA00618Solenoid · faultySTATUS MESSAGE FLAP-SLAT CONTROL 2 DISPLAYED. SUSPECT VALVE SHUTOFF SOLENOID. CHECKED RESISTANCE AT PRIMARY CONTROL SHUTOFF VALVE SOLENOID (V27004). FOUND SOLENOID NEEDS REPLACEMENT. REPLACED SOLENOID. ACFT OK FOR SERVICE.
SDR 2008UALA00639Fitting · brokenDOOR 4L AFT GIRT FITTING END BROKEN. REPLACED BRACKET. CHECKED DOOR GIRT BAR OPERATION PER 25-66-01 NORMAL. ACFT OK FOR SERVICE.
SDR 2008UALA00619Engine · damagedSILENT SURGES DETECTED IN NR 1 ENGINE. ENGINE REPLACED AT SFO DUE TO HEAVY HP COMPRESSOR BLADE DAMAGE FOUND BY BORESCOPE INSPECTION. ONE BLADE WAS FOUND BROKEN IN THE AIRFOIL. SUSPECT DAMAGE TO BE THE RESULT OF VSV INNER TRUNNION BUTTON LIBERATION. THIS ISDR 2008UALA00617Power Supply · inoperativeALL EMERGENCY LIGHTS ON SEATS IN AFT SECTION OF COACH ARE INOP. REPLACED EMERGENCY POWER SUPPLY AT DOOR 3R.SDR 2008UALA00640Engine · making metalENG OIL FILTER L DISPLAYED ON EICAS. ENGINE REPLACED AT SFO DUE TO FERROUS METAL FOUND ON ALL MAGNETIC CHIP DETECTORS (MCD'S). AS OF 03/04/08 ENGINE IS IN UA'S ENGINE SHOP UNDERGOING TEARDOWN INVESTIGATION. EXPECT FINAL FINDINGS BY 03/31/08.SDR 2008UALA00586Panel · puncturedOUTBOARD PANEL, ABOVE T/E FLAP PUNCTURED FROM FLAP GUIDE TRACK. SUSPECT FLAP TRACK SNAPPED. REMOVED PANEL AND ROUTED TO SHOP ON R & R NR R16520. REINSTALLED PANEL. ACFT OK FOR SERVICE.SDR 2008UALA00508Oxygen System · low pressureCREW OXYGEN IS LOW. SUSPECT LOW DUE TO PRE FLIGHT CHECKS. SERVICED CREW OXYGEN BOTTLE. ACFT OK FOR SERVICE.SDR 2008UALA00507Skin · nickedRIGHT I/B MAIN FLAP UPPER PANEL HAS A NICK AROUND A FASTENER HOLE, APPROX 1.8 INCHES FROM O/B END AND 36.10 FROM AFT END. SUSPECT FOREIGN OBJECT DAMAGE
REPAIRED PER SRM 51-00-04, OK TO CF PER EVA-71089. ACFT OK FOR SERVICE.SDR 2008UALA00504Unknown · smokeFLIGHT DIVERTED DUE TO SMOKE AND ODOR REPORTED IN CABIN AND COCKPIT.SDR 2008UALA00494Hinge · brokenSEAT 26HJ OXYGEN MASK BOX DEPLOY PANEL HAS BOTH HINGES BROKEN. SUSPECT BROKEN BOX ASSEMBLY REPLACED 2 EACH HINGES AND SECURED PANEL. ACFT OK FOR SERVICE.SDR 2008UALA00499Pump · malfunctionedR CENTER BOOST PUMP UNABLE TO OPERATE. SUSPECT FAULTY FUEL PUMP. REPLACED CENTER RT ELECTRIC OVERRIDE FUEL PUMP. OPS CHECKS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA00482Fire Loop · failedRTFL DUE TO NR 2 ENGINE FIRE DETECTION LOOP FAILURE.SDR 2008UALA00461Light · out of positionEMERGENCY PATH LIGHT IS OUT OF ITS TRACK 3F. RESECURED PATH LIGHTING.SDR 2008UALA00529Lug · corrodedFOUND NR 2 ENGINE GENERATOR FEEDER LUGS DISCOLORED, PITTED AND PROTECTIVE COATING FLAKED OFF. SUSPECT PITTING AND CORROSION. REPLACED TERMINAL LUGS PER SWPM 20-15-21. PAGE 5.ACCOMPLISHED ENGINE RUN AND OPS GOOD PER MM-24-11-19 P410. ACFT OK FOR SERVICE.SDR 2008UALA00449Oven · smokeAFT GALLEY HAD SMOKE AND CONTROL PANEL VERY HOT. ALL AFT GALLEY C/B PULLED. SMOKE HAS DISSIPATED. OVEN SHORT -FOUND OVEN R52 SMOKING. REPLACED OVEN. TURNED ON ALL GALLEY EQUIPMENT NO SMOKE NOTED IN AFT GALLEY,CONTROL PANEL IS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA00443Unknown · smokeFLIGHT DIVERTED AFTER A PACK VALVE EICAS MESSAGE WAS DISPLAYED & SMOKE WAS DETECTED.
SDR 2008UALA00435Battery Pack · dischargedEMERGENCY DOME LIGHT IN COCKPIT IS INOP. REPLACED BATTERY PACK. REPLACED BATTERY PACK.SDR 2008UALA00413Light · missingSEAT 3E IS MISSING AFT EEL LIGHT. REPLACED EEL LIGHT.SDR 2008UALA00387Battery · dischargedA/C LOST POWER AT GATE PRIOR TO DEPARTURE. ACFT WILL NOT POWER UP. SUSPECT BATTERY VOLTAGE LOW. REPLACE MAIN AND APU BATTERYS. REPLACED APU BATTERY CHARGER. OPERATION NORMAL. REPLACED MAIN BATTERY CHARGER. GRD CHECKED NORMAL. ACFT OK FOR SERVICE.
SDR 2008UALA00386Connector · damagedBLEED LOOP 2 BODY FAILURE OF BODY DUCT LEAK DETECTION LOOP OR RIGHT DUCT LEAK OVERHEAT DETECTION SYSTEM (DLODS) CARD. SUSPECT POSSIBLE HIGH RESISTANCE. CONNECTOR DP8402 PINS 45 AND 46 HAVE A RESISTANCE OF 136.9 OHMS. SHOULD BE 128.7 (+-12.9) . RE-TORQUED CONSDR 2008UALA00341Light · brokenEMERGENCY LIGHTING STRIP BROKEN ON SEAT 2F. REPLACED LIGHT STRIP.SDR 2008UALA00343Light · inoperativeEMERGENCY EXIT LIGHT OUTSIDE DOOR 3L INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00344Fire Detector · false indicationPER FLIGHT ATTENDANT PANEL AT DOOR 1 LEFT FLASHED RED WITH FIRE DETECTED AND AT DOOR 3 RIGHT GOT A RED FIRE INDICATION. RESET PAX SERVICE ENTERTAINMENT UNIT (PSEU) AND ACCOMPLISHED PSEU ADJUSTMENT. TESTED & CHECKED FIRE DETECTION SYSTEM PER MM'S 26- 10-01,