Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2004UALA00248Smoke · detectedSMOKE ORIGINATE MOMENTARILY AT BEGIN OF DESCENT ON CAPT'S SIDE IN COCKPIT. APU, SHOULDER-FOOT HEATERS OFF. THE REPORT OF SMOKE WAS ON A FLIGHT FROM LAX TO HNL. HNL MX CONDUCTED A COMPREHENSIVE CHECK OF NR 1 ENGINE FOR OIL LEAKS, BUT FOUND NONE. MAINTENANCESDR 2004UALA00234Fitting · out of adjustDOOR 4L AFT GIRT BAR PICK UP FITTING CRACKED. CAUSE LATER WAS DETERMINED TO BE THE THRESHOLD GIRT BAR FITTING OUT OF ADJUSTMENT, RESULTING IN A PRELOAD ON THE GIRT BAR AND THE GIRT BAR FITTING WHEN THE DOOR WAS CYCLED THROUGH ARM/DISARM. THE GIRT BAR FITTINGSDR 2004UALA00191Computer · malfunctionedLIGHTNING STRIKE ON FWD RADOME AND F/O WINDSHIELD WITH STATIC DISCHARGE. POSSIBLE RADIOS/NAVIGATION INTERMITTENT. ON APPROACH TO ICN, CREW REPORTED THE AUTOPILOT DISCONNECTED, IT WAS RESET BY CREW AND TRIPPED AGAIN. THERE WERE ALSO ABNORMAL ILS INDICATIONS.SDR 2004UALA00233Fitting · crackedI/B ACTUATOR FITTING CRACKED. REPLACED ACTUATOR FITTING.SDR 2004UALA00177Link Assy · crackedHYDRAULIC LINE SUPPORT BRACKET BROKEN AT TRUCK OF LEFT MAIN LANDING GEAR. LEFT MLG HYD TUBE SUPPORT LINK ASSY (P/N 272W6161-3) WAS FOUND CRACKED AT THE INBOARD LOWER ATTACH LEG. SUPPORT LINK ASSEMBLY WAS REPLACED. BOEING NOTIFIED THIS IS A REOCCURRING PROBLSDR 2004UALA00175Engine · overheatedRIGHT ENGINE OIL TEMP TO 145C AND OIL PRESSURE DROPPED TO 40-45 PSI TOP OF DESCENT INTO KIX. SHUT DOWN ENGINE. NR 1 BEARING FAILURE. THIS IS THE MAIN THRUST BALL BEARING SUPPORTING THE N1 ROTOR. OUTER RACE HEAVILY SPALLED THROUGH 100¡ ARC. ONE BALL HEAVILY SDR 2004UALA00176Idg · malfunctionedRIGHT GEN EICAS MSG, DISCONNECTED RIGHT GEN AND STARTED APU. CREW OBSERVED EICAS ADVISORY MSG, ELECT GEN DRIVE R, WITH MAINT MSG (LOW FREQ & LOW OIL PRESS), WHICH ILLUMINATED GEN DRIVE LIGHT. DISCONNECTED IDG. SHOP RECORDS INDICATED OVERHAUL 4/02. ON-WING ISDR 2004UALA00155Stator · misinstalledINTERMITTENT ODOR AND HAZE IN CABIN. T2 STATOR ASSEMBLY OFTEN SUPPLIED BY THE VENDER AS COMPLETELY ASSEMBLED. SUBASSEMBLY HELD TOGETHER BY TWO WRAPS OF SAFETY WIRE FOR SHIPMENT. UNITED SHOP PROCEDURES DOES STATE TO REMOVE WIRE IF PRESENT (OEM CMM USED). UNISDR 2004UALA00151Indicator · brokenEXIT PATH LIGHTING INDICATOR LOOSE-BROKEN 11F. REPLACED AND TESTED LIGHT ASSY.SDR 2004UALA00121Light · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE AT DOOR 4R. REPLACED LAMP. OPS CHECKED OK.SDR 2004UALA00120Skin · gougedTWO GOUGES IN EXTERIOR FUSELAGE SKIN AT STA 508 STR 47R-48R. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2004UALA00106Odor · detectedFA REPORTED RUBBER BURNING ODOR NEAR 2L. THE REPORT OF BURNING ODOR WAS ON A FLT FROM SFO TO OGG. PROBLEM COULD NOT BE DUPLICATED AT OGG: OGGMM RAN MID GALLEY POWER, OVEN, CHILLERS, AND UPR & LWR RECIRCULATION FANS, CHECKED MID GALLEY CEILING, BUT NOTED NO BUSDR 2004UALA00098Support Fitting · brokenDOOR 2L WILL NOT DISARM. ONE OF THE CASTINGS THAT LIFT THE SLIDE GIRT BAR WHEN ACTUATED BY THE DOOR ARM/DISARM LEVER, WAS FOUND BROKEN, PREVENTING THE SLIDE GIRT BAR FROM BEING LIFTED FREE OF THE FLOOR GIRT FITTING. THE FITTING WAS REPLACED AND THE GIRT BAR SDR 2004UALA00099Slide · deployedTHE 2R EMERGENCY EVACUATION SLIDE PARTIALLY DEPLOYED. DOOR 2R SLIDE/RAFT PARTIAL DEPLOYMENT OCCURRED DURING SLIDE INSTALLATION. DURING INSTALLATION SEQUENCE THE DOOR WAS ARMED, THEN WAS INADVERTENTLY OPENED SUFFICIENT TO RELEASE THE SLIDE PACK. AMM PROVIDES ASDR 2004UALA00095Lamp · inoperativeAFT EEL LIGHT AT 1E BROKEN IN TWO. REPLACED EEL LAMP ASSY.SDR 2004UALA00096Battery Pack · inoperativeEMERGENCY EXIT CEILING LIGHTS INOP FIRST ROW COACH TO DOOR 3L. REPLACED BATTERY PACK.SDR 2004UALA00094Circuit Breaker · failedBURNING ODOR FROM FORWARD GALLEY WITH SMOKE DRIFTING INTO FIRST CLASS CABIN AND DISBURSED IN BUSINESS. REPLACED CIRCUIT BREAKER C002.SDR 2004UALA00082Wire · overheatedFIRST CLASS GALLEY OVENS AND HOT PLATES INOPERATIVE. WIRES BECAME OVERHEATED AT CONNECTION POINT OF C1 LUG ON 15 AMP CIRCUIT BREAKER C003 SUPPLYING POWER TO A FIRST CLASS OVEN. THIS CIRCUIT BREAKER IS ALSO IN A PARALLEL CIRCUIT THAT SUPPLIES POWER TO ADDITIOSDR 2004UALA00051Wire Harness · damagedSEAT 1E EMERGENCY PROX LIGHTS OUT. SEAT 3E EMERGENCY PROX LIGHT OUT. SEATS 39G AND 34C EMERGENCY PROX LIGHTS OUT. REPLACED HARNESS. REPLACED LAMP ASSY. RELAMPED.SDR 2004UALA00052Fitting · crackedINBOARD AND OUTBOARD ACTUATOR FITTINGS CRACKED. REPLACED ACTUATOR FITTINGS.SDR 2004UALA00038Light · brokenEEL LIGHT BROKEN ON WALL BEHIND SEAT 9F. EEL LIGHTS INOP IN ROWS 1 THRU 9. EEL LIGHTS ARE INOP LEFT HAND WALL OF CENTER LAV 1. REPLACED LIGHT 2 & 3. SECURED CONNECTOR ON BATTERY PACK.SDR 2004UALA00053Fitting · crackedACTUATOR FITTINGS CRACKED. REPLACED FITTINGS.SDR 2004UALA00054Wedge · delaminatedT/E WEDGE DELAMINATED AND DENTED. REMOVED, REPAIRED AND REINSTALLED.SDR 2004UALA00008Engine · flamed outNR 1 ENGINE FLAMEOUT IN FLIGHT. CREW UNABLE TO RESTART ON 2 ATTEMPTS. FUEL PUMP MAIN STAGE FAILURE. IMPLEMENTING SOFT TIME THRESHOLD FOR OVERHAUL OF PUMPS AT SHOP VISIT. REMOVING HIGH-TIME PUMPS IN-SERVICE. TEARDOWN FINDINGS WILL BE ANALYZED TO DETERMINE IFSDR 2005UALA00028Skin · damagedLOWER FWD CORNER OF AFT PIT DOOR HAS TEMP REPAIR INSTALLED. AFT CARGO DOOR HAD A PREVIOUSLY INSTALLED TEMPORARY REPAIR. THE TEMPORARY REPAIR WAS REMOVED AND REPLACED WITH A PERMANENT REPAIR.SDR 2004UALA00003Fan Blade · contaminatedHIGH ENGINE VIBRATION ON NR 1. ENGINE CONDITION MONITORING DETECTED HIGH N1 FREQUENCY VIBRATION ON ALL 3 ACCELEROMETERS, ACCOMPANIED BY DOWNWARD SHIFT IN EGT MARGIN. CONSEQUENTLY, IMPENDING ENGINE FAILURE WAS SUSPECTED. THE EGT LOSS WAS SUBSEQUENTLY DETERMISDR 2003UALA00991Transducer · defectiveLOST ALL CREW OXYGEN. DEFECTIVE O2 TRANSDUCER. REPLACED TRANSDUCER.SDR 2003UALA00981Socket · shortedCEILING EMERGENCY LIGHT AT 35 AND 36G OUT. REPAIRED SHORTED SOCKET AND REPLACED EMERGENCY LIGHT POWER SUPPLIES.SDR 2003UALA00979Control Unit · failedSMOKE AND ODOR REPORTED IN CABIN. F/A DISCONNECTED SEVERAL WIRES UNDER 19C AND 18C, CREW REPORTED GALLEY POWER AND SEAT POWER TURNED OFF PRECAUTIONARY, SMOKE AND ODOR DISSAPATED. SEAT ELECTRONIC UNIT AT SEAT 18D FAILED. UNIT WAS REPLACED. SYSTEM OP NORMAL.SDR 2003UALA00962Line · contaminatedON CLIMB TO FL410 FROM FL370 ENGINES MAXED OUT. PWR REQ 1.47 LEFT ENG TOPPED OUT. RIGHT 1.430 WITH RT THROTTLE AT STOP AND LT ENG THROTTLE ABOUT 1 & 1 AND A HALF INCHES BEHIND. THRUST SHORT FALL WAS CAUSED BY AN AMBIENT PRESSURE (PAMB) SENSOR ERROR TO THE ESDR 2003UALA00958Circuit Board · failedSMOKE COMING OUT OF SEAT ELECTRONIC UNIT. DISCONNECTED WIRES TO UNIT AND POWER SWITCHED OFF TO ENTERTAINMENT SYS AND LAPTOP POWER. THE VIDEO DISTRIBUTION BOX AT SEAT 13F FAILED. THE UNIT WAS REPLACED AND ENTERTAINMENT SYSTEM OP CHECKED OKAY. THE UNIT WAS ESDR 2003UALA00928Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT SEAT 2F AFT POSITION. REPLACED LIGHT ASSY.SDR 2003UALA00867Light · inoperativeEMERGENCY LIGHT INOP AT SEAT 3F AFT MOST. REPLACED EMERGENCY LIGHT ASSY.SDR 2003UALA00862Floorbeam · crackedSTA 246 FLOORBEAM LBL 7.88 VERTICAL STIFFENER CRACKED. MAJOR REPAIR ACCOMPLISHED. STIFFENER REPLACED.SDR 2003UALA00855Heater · failedBURNING RUBBER ODOR COMING FROM OVERHEAD VENTS IN NR 2 GALLEY. RECIRC FANS OFF, ODOR DISSIPATED. ODOR COMPLAINTS COMPLETELY STOPPED AFTER REPLACEMENT OF AREA HEATER AT DOOR 2 RIGHT.SDR 2003UALA00852Lamp · inoperativeAFT EMERGENCY LIGHT INOPERATIVE AT SEAT 1E. RELAMPED EMERGENCY LIGHT.SDR 2003UALA00856Fitting · crackedAILERON ACTUATOR FITTINGS CRACKED. REPLACED ACTUATOR FITTINGS.SDR 2003UALA00843Fitting · crackedDOOR 2R WAS DIFFICULT TO DISARM AND OPEN. GIRT BAR LIFT MECHANISM AFT BRACKET WAS FOUND TO BE BROKEN IN THE RADIUS. REPLACED BRACKET PER AMM 52-11-17.SDR 2003UALA00826Acm · seizedRT AIR CYCLE MACHINE CMC MESSAGE AND SMOKE ODOR REPORTED IN CABIN. SMOKE & ODOR REPORT IN THE CABIN WAS DUE TO HAZE & ODOR OF HOT METAL RELEASED BY SEIZED RT ACM. SUSPECT RT ACM FAILURE WAS DUE TO CLOGGED RT COND/REHEATER. RT ACM & RT COND/REHEATER WERE REPLSDR 2003UALA00815Failsafe · crackedSTA 2260 LT FUSELAGE STA 2260 LONGERON FAILSAFE STRAP CRACKED. MAJOR REPAIR. STRAP REPAIRED.SDR 2003UALA00797Actuator · failedCOULD NOT PRESSURIZE AIRCRAFT ON CLIMBOUT. DOWNLINKED CMC DATABASE SHOWED MAINTENANCE MESSAGE 21-39080, THE CABIN PRESSURE COULD NOT BE CONTROLLED DUE TO FAILED AFT OUTFLOW VALVE CONTROL UNIT (VCU). AFTER REPLACING THE FAILED ACTUATOR ASSY (COMPRISED OF THE SDR 2003UALA00798Wire · detachedWIRES DETACHED FROM EMERGENCY EVAC LIGHTS ON SEAT SHROUD. REPLACED AFT EMERGENCY LIGHT ASSY.SDR 2003UALA00793Lamp · inoperativeSEAT 1E, AFT EMERGENCY LIGHT INOP. RELAMPED.SDR 2003UALA00779Skin · delaminatedNR 4 SLAT DELAMINATED AT OB END LOWER SURFACE OF T/E WEDGE. AREA 2.2 INCH CHORDWISE X 3.0 INCH SPANWISE LOCATED 1.5 INCH FROM OB END AND 3.0 INCH FROM T/E. THE ABOVE NOTED DELAM CONDITION WAS DUE TO WEAR FROM NORMAL LOADS EXPERIENCED DURING A FLIGHT OVER A PERSDR 2003UALA00778Skin · delaminatedNR 2 SLAT DELAMINATED AT OB END LWR SURFACE OF T/E WEDGE. AREA IS 1.6 INCHES CHORDWISE X 1.3 INCHES SPANWISE AT 1.3 INCHES FROM OB END AND 1.6 INCHES FROM T/E. THE ABOVE NOTED DELAM CONDITION WAS DUE TO WEAR FROM NORMAL LOADS EXPERIENCED DURING A FLIGHT OVER SDR 2003UALA00777Skin · delaminatedNR 1 SLAT DELAMINATED OB END OF LOWER SURFACE OF T/E WEDGE OF AREA 3.3 INCHES CHORDWISE X 1.6 INCHES SPANWISE. THE ABOVE NOTED DELAM CONDITION WAS DUE TO WEAR FROM NORMAL LOADS EXPERIENCED DURING A FLIGHT OVER A PERIOD OF TIME. THE TRAILING EDGE WEDGE OF THESDR 2003UALA00773Light · missingSEAT 1F OB SIDE EMERGENCY LIGHT HAS SECTION MISSING. REPLACED LIGHT.SDR 2003UALA00765Light · damagedEMERGENCY EXIT LIGHTS DAMAGED. SECURED SEAT EMERGENCY EXIT LIGHT.SDR 2003UALA00758Carbon Seal · damagedOIL SMELL IN COCKPIT ON DESCENT. APU WAS REPLACED AND SHOP DISASSEMBLED GEARBOX AND LOAD COMPRESSOR. ENGINEERING FOUND INDICATIONS THAT THE LOAD COMPRESSOR FRONT CARBON SEAL TO BE THE ROOT CAUSE FOR SMELL IN CABIN. THE LOAD COMPRESSOR CARBON SEAL HOUSING WSDR 2003UALA00757Skin · gougedFUSELAGE SKIN 30 INCHES AFT OF L4 DOOR, WL 200.3 WAS GOUGED. MAJOR REPAIR ACCOMPLISHED. REPAIR WITH DOUBLER AND FILLER.
Back to Boeing 777-222