SDR 2001UALA02112Cooling Fan · failedNR 2 EQUIP COOLING FAN EICAS MESSAGE WITH SMELL ON FLT DECK. RTN TO GATE. FOUND RT EQUIPMENT COOLING FAN INOP. REPLACED FAN. AIRCRAFT RETURNED TO REVENUE SERVICE WITHOUT FURTHER INCIDENT.SDR 2001UALA02104Slide · cutDOOR 1 RT SLIDE/RAFT P/N 62771-118, S/N 0284 FOUND TO HAVE 5 CUTS IN INFLATABLE. CUTS FOUND DURING SHOP OVERHAUL OF THE UNIT. THERE WERE 3 CUTS IN TOP TUBE AND 2 IN BOTTOM TUBE ON RT SIDE OF SLIDE/RAFT ABOVE BOTTOM TUBE RELIEF VALVE. CUTS IN THE INFLATABLE ASDR 2001UALA02090Actuator · seizedLEFT ENGINE WOULD NOT COME OUT OF IDLE. DIVERTED TO CCS. LEFT ENGINE WENT INTO SUB-IDLE STALL ACCOMPANIED BY STATOR VANE FAULT MSG. LATER DURING DESCENT TO DIVERSION STATION, ENG FAIL MSG ILLUMINATED & FLIGHT CREW SHUT THE ENGINE DOWN AND MADE A SINGLE-ENGISDR 2001UALA02056Stiffener · crackedSTATION 246 RBL 40 FLOOR BEAM VERTICAL STIFFENER CRACKED SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHEDFABRICATED AND INSTALLED NEW STIFFENERNOTED CRACKING OF THE STIFFENER IS DUE TO THERMAL CONTRACTION THAT RESULTS IN HIGHER THAN EXPECTED IN-SERVICE LOADISDR 2001UALA02055Stiffener · crackedSTATION 246 RBL 38 FLOOR BEAM VERTICAL STIFFENER CRACKED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHEDFABRICATED AND INSTALLED NEW STIFFENER.NOTED CRACKING OF THE STIFFENER IS DUE TO THERMAL CONTRACTION THAT RESULTS IN HIGHER THAN EXPECTED IN-SERVICE LOASDR 2001UALA01936Switch · faultyENG FUEL FILTER R EICAS MSG DURING CLIMB. POWER (CLIMB) STABLE. ACFT ATTITUDE 8 DEGREES NOSE-UP. RTF. 2 FAULT MESSAGES: 73-60912 SWITCH POSITION SIGNAL FROM FUEL PUMP FILTER DIFF PRESS SW (R ENG) CHANNEL A AND B DO NOT AGREE AND 73-60922 FUEL PUMP FILTER DSDR 2001UALA01937Chiller · malfunctionedCHILLER IN BUSINESS CLASS CAUSING BURNING SMELL, CREW TURNED OFF CHILLER AND SMELL DISSIPATED. REPLACED FWD CHILLER, RAN BOTH CHILLERS 5 MINUTES AND NOTED NO SMELL.SDR 2001UALA01924Pcu · leakingACFT RETURNED TO FIELD DUE TO HYDRAULIC LEAK. FOUND NR 6 SPOILER, LEFT WING SECOND SPOILER FROM FUSELAGE LEAKING. THIS IS PART OF THE RIGHT HYDRAULIC SYSTEM JUST INBOARD OF LEFT PYLON. PANEL 552FB REMOVED AND HARDWARE IS BAGGED. MAINT REPLACED LEAKING NR 6 SDR 2001UALA01866Light · inoperativeSEAT 3E AFT EEL LIGHT INOP.SDR 2001UALA02091Bearing · wornVIBRATION REPORTED IN CLIMB STARTING AT FL200. VIBRATION COMING FROM COCKPIT FLOOR AND ROW 12 FWD IN PAX CABIN. UPON LEVEL OFF FL300, VIBRATION DID NOT GO AWAY, WITH CABIN CREW REPORTING IT WAS GETTING WORSE. DUMPED FUEL AND RETURN TO IAD. INSPECTED AIRFRASDR 2001UALA01867Light · inoperativeAFT EEL LIGHT ON SEAT 1F INOP.SDR 2001UALA01833Floorbeam · crackedSTATION 246 FLOOR BEAM MID-CHORD CRACKED AT LBL 38.5 NOTED CRACKING OF THE 141W8519-1 MID CHORD IS DUE TO THERMAL CONTRACTION THAT RESULTS IN HIGHER THAN EXPECTED IN-SERVICE LOADING OF THE DOUBLE DEPTH STATION 246 FLOOR BEAM. PART IS BEING REPAIRED.SDR 2001UALA01789Light · damagedSEAT 1E AFTER EMERGENCY LIGHT DOES NOT WORK. FORWARD EMERGENCY LIGHT WORKS OK. LIGHT ASSEMBLY FOUND DAMAGED. REPLACED LIGHT ASSEMBLY. OPS CHECKED GOOD.SDR 2001UALA01714Harness · faultyFLIGHT RETURNED TO FIELD AND LANDED AMBER ALERT DUE TO A HIGH ENGINE TEMPERATURE INDICATION. CREW REPORTS NR 2 EGT BLANKED ON TAKEOFF. RECOVERED AFTER TAKEOFF BUT WAS FLUCTUATING. MAINTENANCE REPLACED ELECTRICAL HARNESS WO635, AFTER WHICH THE FAULT DID NOT SDR 2001UALA01632Door · damagedEN ROUTE FROM FRA TO DEN AIRCRAFT DIVERTED TO LHR DUE TO VIBRATION ON THE RIGHT SIDE OF THE AIRPLANE. FOUND RT RAM AIR INLET DOOR FAILED RESULTING IN VIBRATION AND DAMAGE TO RAM AIR INLET DUCT. DOOR ASSY WAS REPLACED AND INLET DUCT WAS REPAIRED. A/C RETURNEDSDR 2001UALA01607Skin · damagedDAMAGE FOUND ON LT ELEVATOR UPPER SURFACE, APPROX 18 INCHES OUTBOARD OF INBOARD EDGE AND 18 INCHES FWD OF T/E PUNCTURE IS APPROX 1.75 INCHES IN DIAMETER AND 1.25 INCHES DEEP. *S/D* MAJOR REPAIR: ACP REPAIR ON LT ELEVATOR PER SRM.SDR 2001UALA01599Tube · crackedUNSCHEDULED ENGINE REMOVAL DUE TO CRACK IN NR 3 BEARING OIL PRESSURE TUBE FOUND DURING INSPECTION. PRATT & WHITNEY RECALLED CERTAIN P/N 50J041-01 OIL TUBES DUE TO POTENTIAL CRACKING AT CONTAMINATED WELD BEAD, AND NOTIFIED US OF THE POSSIBILITY THAT NR 3 BEARSDR 2001UALA01538Blade · fracturedAPPROX 110 KTS LEFT ENG FAILURE WITH SEVERE DAMAGE. EGT 565, FF0, OIL PRESS 1. ENGINE SHUTDOWN, ABORTED T-O, BRAKE TEMP NORMAL, NORMAL STOP, NO OTHER INDICATIONS. RETURN TO BLOCKS. ENGINE WAS REMOVED DUE TO METAL IN TAILPIPE. FAILURE ORIGINATED AT HIGH PRSDR 2001UALA01480Light · odorHOT BURNING ELEC SMELL COMING FROM THE COVE LIGHTS, SEEMS TO BE IN THE DIM POS.TRIED TURNING OFF ALL CABIN LIGHTS, NO SUCCESS. ALSO READING LIGHTS STUCK IN NORMAL, WOULD NOT TURN OFF PER CREW. PULLED CB'S 02,03,H04,09,L02,03,07,10 AS PRECAUTION. ALSO PULLED SDR 2001UALA01420Structure · gougedMAJOR REPAIR: DENTED AND GOUGE 18 INCHES AFT OF NR 4 LT. MED CUTOUT 8 INCHES UP FROM THRESHOLD. REPAIRED DOUBLER PER SRM 53-00-01 AT APPROX. BS 2087 S-26L.SDR 2001UALA01461Fmu · defectiveL ENG EPR FLUX APPROX. .02 AT CRUISE. ALL OTHER ENG PARAMETERS FOLLOW FLUCTUATION. AUTOTHROTTLE DISCONNECT NO HELP. SUPPLEMENTAL DATA UPDATE REPLACED FUEL METERING UNIT P/N 808800-1 S/N F32614 AT PART TOTAL TIME 20638. EPR FLUX HAS NOT REOCCURRED TO DATE SDR 2001UALA01352Warning System · malfunctionedLOW OIL PRESSURE WARNING INTERMITTENTLY COMING INTO VIEW WITH OIL PRESSURE SHOWING 211 PSI (NORMAL), ALSO WHEN OIL PRESSURE WARNING OCCURRED N1, EPR AND FF FLUCTUATING OCCURRED. AT FL390 M.84V 4 HRS AIRBORNE EICAS MSG ENG OIL PRESS L CAUTION APPEARED OIL PRESSDR 2001UALA01350Control Unit · malfunctioned45 MINUTES OUT FROM JFK (JFK-LHR) EICAS MESSAGES FOR FLIGHT CONTROL SYSTEM AND FUEL FILTER. RETURN TO JFK. FUEL DUMPED. A FLIGHT CONTROL SYS EICAS STATUS MSG WAS CAUSED BY THE RT OUTBD FLAPERON MSG 2710303 PCU DOES NOT FOLLOW COMMAND. MAINT PERFORMED FIM TASKSDR 2001UALA01333Computer · failedSECONDARY ATTITUDE AIR DATA REF UNIT (SAARU) FAILED INFLIGHT.SDR 2001UALA01197Computer · failedRETURNED TO FIELD. NAV ADIRU INERTIAL YELLOW CAUTION ON EICAS. DUMPED FUEL TO MAX LANDING WEIGHT. NORMAL LANDING. *S/D* THE ADIRU FAILED AND CAUSED THE NAV ADIRU INERTIAL YELLOW CAUTION MESSAGE ON THE EICAS. THE ADIRU WAS REPLACED AND THIS CORRECTED THE SDR 2001UALA01681Slat · dentedHAIL DAMAGE DENTED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA01046Wire · shortedEMERGENCY LIGHTS ON SEATS ARE INOP FROM SEAT 31-43 RIGHT AND LEFT SIDE. SUPPLEMENTAL DATA UPDATE CAUSE: MAINT. FOUND A PINCHED/SHORTED WIRE UNDER SEAT PAN AT SEAT 31C WHICH RESULTED IN A BLOWN FUSE AT THE POWER SUPPLY. CORRECTIVE ACTION: MAINT. REPAIRED WIRE &SDR 2001UALA01040Skin · crackedMAJOR REPAIR. RT FUSE SKIN CRACKED FWD OF HORIZ STAB CUTOUT AT FWD LWR CORNER APPROX STA 2256. *S/D* INSTALLED REPAIR PER EVA G95-7726.SDR 2001UALA01041Warning Horn · activatedABORTED TAKEOFF AT APPROX 80 KTS DUE TO ENG FAILURE WARNING HORN SOUNDING.SDR 2001UALA01012Odor · detectedELECTRICAL ODOR IN THE AREA OF ROW 13 AND 14 ON FLOOR AREA DVS SYSTEM, TURNED OFF MASTER POWER SW. CONTACTED SQAMC, RECOMMENDED THAT SYSTEM BE LEFT OFF FOR REMAINDER OF FLIGHT. *S/D* OPERATED THE VIDEO SYSTEM FOR 6:30 HOURS, VIDEO SYSTEM OPERATED NORMAL ANDSDR 2001UALA01194Slide · failedSLIDE RAFT FAILED AIR RETENTION TEST DURING OVERHAUL.SDR 2001UALA00915Control Panel · overheatedELECTRICAL SMELL IN CABIN BY DOOR 2L. *S/D* THE TWO BACKLIGHTS FOR THE TOUCHSCREEN ON THE CACP AT DR 2L HAD FAILED. THE FAILURE CREATED AN OVERHEAT CONDITION AT THE LIGHT INSULATION. THE OVERHEAT OF THE INSULATION WAS THE SOURCE OF THE ODOR. THE CACP WAS SDR 2001UALA00898Light · inoperativeAFT EMERGENCY PROX LIGHT AT SEAT 1F IS INOP. *S/D* POSSIBLE CAUSE OF AFT EMERGENCY PROX LIGHT AT SEAT 1F FAILURE IS DAMAGE TO THE PROX LIGHT FROM PASSENGER LUGGAGE. EXACT FAILURE CAUSE IS UNKNOWN. REPLACED LIGHT ASSEMBLY. OPS CHECKED GOOD.SDR 2001UALA00899Wire · damagedEMERGENCY LIGHTS AT SEAT 3F (FLOOR PROX) ARE INOP. *S/D* EMERGENCY PROX LIGHTS AT SEAT 3F WERE INOP DUE TO CHAFED OR DAMAGED WIRES NEAR THE THE SEAT DISCONNECT ALONG THE WIRE RUN WHICH CONTAINS THE INVERTERS. INSTALLED TEMPORARY REPAIR BY SPLICING WIRE HARNSDR 2001UALA00773Fitting · defectiveNR 8 SPOILER WILL NOT TAKE LUBRICATION AT CNT OUTBOARD HINGE. MAJOR REPAIR. FITTING REWORKED PER EVA G95-7722. SPOILER REMOVED AND REINSTALLED.SDR 2001UALA00752Carbon Seal · leakingACRID-ONLY SMOKE SMELL IN COCKPIT AND CABIN NO SMOKE VISIBLE. OUT OF FL204 IN DESCENT BETTER BY 104. *S/D* REPLACED NR 1 ENGINE. SHOP INVESTIGATION REVEALED NO VISIBLE OIL IN THE ENGINE GAS PATH OR PNEUMATIC DUCTS AND NO EXTERNAL OIL LEAKS. NO OIL IN FAN SDR 2001UALA00651Sense Line · fracturedRIGHT ENGINE DID NOT SPOOL UP TO FULL TAKEOFF POWER, LAG 1.5 KNOTS BEHIND LEFT THROTTLE. ABORTED TAKEOFF AT LOW SPEEDS. *S/D* FOUND PROBLEM WITH LEFT ENGINE PT 4.95 LINE RIGHT ENGINE OPS NORMAL. FOUND LINE BROKEN ON LEFT ENGINE. PER 1-0-13-3 INTRIM REPAIRSDR 2001UALA00646Idg · contaminatedRIGHT GENERATOR DRIVE LIGHT AND RIGHT GENERATOR CONTROL OFF LIGHTS AND EICAS DISCONNECTED RIGHT DRIVE AS PER CHECKLIST. (FUEL JETTISONED APPROX 15,000 LBS) *S/D* ELEC GEN OFF R AND ELEC GEN SYS R STATUS MESSAGES WERE DISPLAYED WITH ASSOCIATED MAINTENANCE MESDR 2001UALA00645Harness · faultyEEL LIGHTS (2) AT 3E INOP. *S/D* MOVEABLE SIDEREST/ARMREST DAMAGED THE FIRST CLASS PROXIMITY LUMINESCENT LIGHT STRIPS WIRE HARNESSES. REPLACED THE FIRST CLASS PROXIMITY LUMINESCENT LIGHT STRIPS WIRE HARNESSES, 2 EA.SDR 2001UALA00598Acm · seizedSFO-FRA, APPROXIMATELY 1.5 HOURS AFTER DEPARTURE, EXPERIENCED AIR FLOW PROBLEMS WITH RIGHT PACK. DUMPED FUEL AND RETURNED TO SFO. *S/D* RT PACK ACM WAS FOUND SEIZED AND WAS REPLACED. AIRCRAFT RETURNED TO REVENUE SERVICE WITH NO FURTHER INCIDENT.SDR 2001UALA00594Eec · out of toleranceON T/O, WHEN ENGAGING AT UPON THRUST APPLICATION, LT ENG LAGGED BEHIND RT, ADDED THROTTLE MANUALLY, EVENTUALLY ALL THE WAY TO STOP EPR WAS PEGGED 1.395 (1.444=REDUCED TO) WITH RT ENG. AT 1.44. ENGS NORMAL OPS AT SETTING OF CLIMB. REPLACED ELECTRONIC ENGINE CSDR 2001UALA00595Eec · inadequateTAKEOFF AT ORD LT ENG EPR 1.51 RIGHT ENG 1.48 EPR. RT THROTTLE SLIGHTLY AHEAD OF LT THROTTLE. AFTER THRUST REDUCTION, EVERYTHING MATCHED UP AND THROTTLES MARRIED UP. *S/D* PRELIM STATUS 5/4/2001: INSP ENG & ACCOMP POWER ASSURANCE RUN, NO DISCREP FOUND. PSDR 2001UALA00566Light · inoperativeEMERGENCY LIGHT ON SEAT 19G INOP. *S/D* BULB IN FLOOR PROXIMITY LIGHT ASSY FAILED. REPLACED FLOOR PROXIMITY LIGHT ASSY.SDR 2001UALA00544Clamp · brokenEICAS BLEED LOSS WING RIGHT INDICATION, FOLLOWED BY RIGHT ISOLATION VALVE CLOSURE, THEN FINALLY THE LOSS OF THE RIGHT AIR CONDITIONING PACK LEAD TO FLIGHT DIVERTING TO MIA. *S/D* FOUND FWD BAND CLAMP FAILED AT LWR RT FLOW CONTROL VLV. THIS CAUSED AIR LEAK, SDR 2001UALA00492Video Unit · failedELECTRICAL ODOR AND SMOKE REPORTED IN AFT CABIN. FLIGHT DIVERTED AND LANDED UNDER AMBER ALERT INTO SNN (SHANNON, IRELAND). MAINT CHECK SEAT FOR FAILED SEAT VIDEO DISTRIBUTION UNITS IN AFT CABIN AREA. SUPPLEMENTAL DATA UPDATE THE VIDEO DISTRIBUTION UNIT AT SEASDR 2001UALA00511Floorbeam · crackedDISCREPANCIES: STA. 246 BUCKLED STIFFENER AT LBL - 7, RBL - 26.06, 50.0STA. 246 CRACKED STIFFENER AT LBL - 38.5STA. 246 CRACKED MID-CHORD AT LBL - 7 REPAIRED MID-CHORD PER SRM 53-10-51, REPAIR 2.REPLACED CRACKED AND BUCKLED STIFFENERS PER SRM 53-10-51, REPAIRSDR 2001UALA00512Floorbeam · crackedSTA 246 MID-CHORD HORIZ LEG CRACKED AT RBL 38.5. *S/D* REPAIRED PER SRM 53-10-51, REPAIR 2.SDR 2001UALA00461Generator · failedLOST RT ENG GEN PRIOR TO ENTERING ETOPS. RIGHT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF AND ENGINE NOT SHUT DOWN. DIVERT TO LHR. SUPPLEMENTAL DATA UPDATE ELEC GEN SYS R EICAS MESSAGE WAS DISPLAYED WITH ASSOCIATED MAINTENANCE MESSSDR 2001UALA00491Inverter · failedFLOOR PROXIMITY EMERGENCY PATH MARKING LIGHTS (SEAT- MOUNTED) ARE INOP AT SEATS 1EF AND 3EF. SUPPLEMENTAL DATA UPDATE FOUND PIN 15 OF CONNECTOR DM33094 PUSHED BACK & LOCK BROKEN AT DR 1 R. FOUND 6 INVERTERS BLOWN IN F/C EEL SYSTEM. FOUND ALL THE BULBS BLOWN SDR 2001UALA00399Floorbeam · crackedSTA 246: FLOORBEAM UPPER WEB IS CRACKED AT RBL 8.5& 38.5. FLOORBEAM MID CHORD UPPER RADIUS IS CRACKED RBL 9,25,50 & LBL 8. FLOORBEAM MID CHORD IS CRKED RBL 38.5. FLOORBEAM MID CHORD UPPRER RADIUS IS CRKED RBL 44. CRKED STIFFNER AT FLOORBEAM RBL & LBL AT 26.
Back to Boeing 777-222