SDR UALA2012092705468Controller · malfunctionedLEFT PACK FAILURE, RTFL. NOTICED WHEN DOING LEAK CHECK ON UPPER FCV THAT THE LOWER FCV WAS FLUCTUATING OR SURGING. REPLACE THE AIR SUPPLY CABIN PRESSURE CONTROLLER PCN 566-9019 FOR LEFT PACK FLOW CONTROL VALVE NOT BEING ABLE TO BE SHUTOFF. REPLACED ASCPC PESDR UALA2012092605448Strip · wornNR 1 ENGINE FIRST AFT HEATSHIELD GAP STRIP WORN. BLENDED DAMAGED AREAS ON NR 1 GAP STRIP, NR 1 ENGINE. OUTBOARD AREA AFTER CLEAN HAS DEPTH OF .140X1&13-16" LONG. INBOARD AREA AFTER CLEAN UP HAS A DEPTH OF .070X1&3-8" LONG. WILL REQUIRE HFEC TO TRIM LINE. SDR UALA2012092705454Warning System · false activationEICAS MESSAGE DETECTOR FAN 1 CARGO FORWARD SHOWED AT DEP. MAINT MESSAGE 26-21041 MAT TEST FAIL PER FIM 26-16 TASK 803. MSG DET FAN 1 CGO FWD NOT DISPLAYED ON EICAS, NO EXISTING OR INBD FLIGHT FAULTS. ACCOMPLISHED GROUND TEST 26 CARGO SMOKE DET SYS TEST PER SDR UALA2012092705455Unknown · vibrationHUMMING AND VIBRATION COMING FROM DOOR 3L. INSPECTED AREA, NO OVERHEAT, OR LEAKS, HUMMING VARIES WITH APU PNEUMATICS OFF OR WHEN PACKS ARE TURNED ON. SUSPECT AIR PRESSURE BUILDUP IN DUCTS WHEN NO DEMAND CALLED FOR. THIS IS A KNOW CONDITION. INSPECTED PAX ANSDR UALA2012092505432Light · inoperativeFORWARD EMERGENCY LIGHT AT SEAT 3F INOP. REPLACED LIGHT ASSY LIGHT SECURE IN SEAT, LIGHTS OPS CHECK GOOD.SDR UALA2012092705456Bellows · tornODOR IN THE CABIN-FD. DUE TO HISTORY OF ODOR IN THE CABIN-FD. REPLACED TORN BELLOW ON FLEXIBLE SURGE DUCT. REF AMM FOR VALVE REMOVED AND REPLACED. REMOVED APU SOV & INSPECTED UPSTREAM & DOWNSTREAM OF VALVE. NO OIL CONTAMINATION NOTED, DUCT CLEAN. RE-INSTSDR UALA2012092505435Controller · inoperativeLEFT MANIFOLD PRESSURE - FLOW SENSING SYSTEM INOPERATIVE. SAMC TEXT: FLIGHT CREW COMPLIED WITH MEL. OPBLM DEFERRED PER SAMC. REPLACED LEFT ASCPC PER MM, OPS CHECK NORMAL PER MAT.SDR UALA2012092405419Pcu · faultyFLAPERON ACTUATOR STATUS MSG-REPEAT. REPLACE RIGHT INBOARD FLAPERON PCU PER AMM. SYSTEM OPS CHECK NORMAL.SDR UALA2012092405418Unknown · malfunctionedFLAPERON ACT STATUS: MSG 27-10302 ACTIVE & LATCHED. ACP'D FIM 27-11 TASK 816 STEP C. FOUND WIRE CHECKS GOOD. REF STEP C.(3), REPLACED ACE-L2 (M2712 2) PER MM27-02-02. LRU REPLACEMENT TEST CHECKS OK BUT FLAPERON POSITION SYSTEM TEST FAILS WITH MSG 27-16039,SDR UALA2012092405423Module · faultyR FMC EICAS MSG DISPLAYED. REPLACED RIGHT AIMS M2 CPM-BASIC MODULE PER AMM AND RELOADED ALL APPROPRIATE SOFTWARE. OP CHECK OKAY.SDR UALA2012092405400Restraint · twistedF/A JUMP SEAT AT DOOR 3 CROSS AISLE LEFT SIDE HAS A SHOULDER HARNESS THAT WILL NOT MOVE *FIX-JHT. CROSS AISLE AT DOOR 3, LEFT F/A SEAT, BUCKLE SIDE HARNESS DOES NOT RELEASE. SEAT STOWED, TAPED AND PLACARD. TAPPED ON RESTRAINT REEL, SEEMS TO JAM INTERMITTENT.SDR UALA2012092405420Control Panel · faultyAUDIO CONTROL PANEL PROBLEM. SWAPPED 1ST OFFICER WITH 1ST OBS PANEL. F/O PANEL OP CHECK OK. 1ST OBSERVERS PANEL RECEIVES NR 2 VHF BUT CAN`T TRANSMIT. F`O'S SYSTEM, OP CHECK OK. CAPTAINS AUDIO SYSTEM FUNCTIONS NORMALLY. SHOULD BE SEC OBSERVERS. REPLACE ASDR UALA2012092405385Skin · delaminatedON WALK AROUND FOUND POSSIBLE DELAMINATION ON RIGHT SIDE OF VERT STAB. ITEM ROLLED FORWARD. REF IPC55-34-51-008, PANEL HAS 11 BY 8 AREA OF DELAM IN MIDDLE OF PANEL. REF SRM 55-30-01. NEED TO ACP INTERIM REPAIR PER ECRA 5530-01666 AVAILABLE ON EDOCS. ACCOSDR UALA2012092405409Computer · faultyRIGHT MFQ BLANKING. DUE TO REPEAT REPORTS OF RT MFQ INDICATION BLANKING AND BOEING AHM DOWNLOADING MAINTENANCE MESSAGES 24-11111 AND 24-12250 ACCOMPLISH FIM 28-41 TASK 801. IF NO FAULTS FOUND REPLACE FQPU C-I483-9211 PRECAUTIONARY. REPLACED FQTY PROCESSOR, SDR UALA2012092005326Probe · faultyCENTER TANK FUEL QTY INDICATION WAS READING 103.7 AT PUSHBACK, DURING TAXI QTY DROPPED TO 94.8. NEED TO DRIP CENTER TANK AND VERIFY CENTER TANK QTY FOUND CTR TANK QTY READING BELOW DIP STICK READING BY APPX 1200 LBS. CTR TANK GAUGE CONSIDERED INOP. REFUELED ACSDR UALA2012092005340Unknown · odorACRID SMELL IN COCKPIT GOING THRU 14000 DESCENT. ON ARRIVAL NO SMELL IN CABIN , NOR COCKPIT. NO MSG FOUND. ACPD FAULT ISOLATION PROCEDURE PER FIM 21-00 TASKS 808 FOUND ALL NORMAL. NO EVIDENCE OF BIRD STRIKE ON BOTH ENGINE. RUN APU AND PACKS FOR ONE HOUR NSDR UALA2012092005323Actuator · faultyFLIGHT CONTROL SYSTEM EICAS MESSAGE. NEEDS RIGHT INBOARD FLAPERON ACTUATOR REPLACED. REPLACED RIGHT FLAPERON INBOARD ACTUATOR AS PER AMM. ALL REQUIRED MAT TEST PASSED OPS AND LEAK CHECK ACCOMPLISHED. NO LEAKS NOTED, ALL INDICATIONS NORMAL NOW.SDR UALA2012092005336Door · damagedFORWARD CARGO HANDLING ACCESS PANEL DOOR P24 DAMAGED ACCOMPLISHED BLEND & RE WORK PER SRM. ALLOWABLE DAMAGE 1 FIG 102. DOOR ALLOCHROMED AND PRIMED. REQUIRES RE-EVALUATION AND DENT DOT. NDT ON DOOR OK. IF REQUIRED DOOR PART NUMBER IS 141W5350-1. BLENDED PSDR UALA2012091905313Start Valve · faultyENGINE START VALVE R ON START WITH NO ROTATION. REPLACED START VALVE ON RT ENGINE DRY MOTORED ENG ALL IND NORMAL REF JRH & MM71-00 & REF SMC08.SDR UALA2012092105363Charger · faultyBATTERY CHARGER STATUS MESSAGE IS DISPLAYED. REPLACED AND TESTED CHARGER PER MM, TESTS GOOD.SDR UALA2012092105362Battery · faultyMAIN BATTERY STATUS MESSAGE IS DISPLAYED. REPLACED AND TESTED BATTERY PER MM, TESTS GOOD.SDR UALA2012091905296Apu · making metalAPU CONTROL STATUS MSG. LATCHED FAULT MSG 49-12990. FIM TASK 49-20-813 - CHECKED CHIP DETECTORS PER AMM 49-27-04 AND FOUND LARGE QUANTITY OF PARTICLES ON OIL SUMP DETECTOR AND SMALL (FUZZ) ON TURBINE BEARING SCAVENGE DETECTOR. COMPLETED APU INSTALLATION PERSDR UALA2012091905287Panel · wornNR 2 PYLON LEFT SIDE WORN ON INNER SURFACE OF PANEL 443CL CUTOUT. REPAIRED IAW ECRA 5431-01061.SDR UALA2012091905286Panel · wornNR 1 PYLON LEFT SIDE WORN ON INNER SURFACE OF PANEL 433CL CUTOUT. REPAIRED IAW ECRA 5431-01061.SDR UALA2012091905312Shutoff Valve · failedTRIM AIR PRSOV LEFT TRIM AIR PRESSURE RELIEF SHUT OFF VALVE (PRSOV) FAILED. REPLACED LEFT TRIM AIR PRSOV PER MM, OPS CHECK NORMAL, NO MESSAGE.SDR UALA2012091905311Sense Line · crackedLEFT EEC FAILED. LEFT UPPER PROBE AFT SENSE LINE PER FIM TASK 77-11 805 & MM 77-11-01. REPLACED AFT LEFT UPPER PROBE SENSE LINE ACCT SEPARATED-CRACKED AT B-NUT ON PROBE END.SDR UALA2012091905300Duct · brokenFLEXIBLE DUCT OF THE APU SURGE DUCT ASSY FOUND WITH BELLOWS BROKEN OFF. REPLACED FLEX DUCTSDR UALA2012091805254Display · faultyF/O NAV DISPLAY BLINKING ON AND OFF. F/O NAV DISPLAY BLINKS, SWAPPED WITH CTR LOWER DISPLAY UNIT PER MEL, CB COLLARD. REPLACED CENTER LOWER ND PER MM.SDR UALA2012091805253Switch · malfunctionedMID GALLEY HAS NO POWER TO HALF OF GALLEY. FOUND ENTIRE MID GLY POWER OFF WITH GUARDED POWER SWITCH IN NORMAL POSITION, MAT SHOWED MSG 25-31 003. AFTER CYCLING GLY SWITCH PER FIM 25-31-803 GLY PWR NORMAL. PER FIM 25-31-803 THERE WAS AN INTERMITTENT FAULT, GSDR UALA2012091405200Hinge · out of adjust1K CONSOLE LOCK INOP, FOUND SIDE COMP'T DOOR WILL NOT OPEN. REPLACED LATCH. STILL NO HELP. NEED MORE TIME TO ADJUST DOOR HINGE. VERIFIED COMP'T IS EMPTY AND DOOR SECURED CLOSE.SDR UALA2012091305181Sdu · faultySATCOM SYSTEM STATUS MSG. CHECKED MAT AND FOUND MAINT MSGS OF 23-69951 AND 23-68801. BOTHS FIM PROCEDURES REQUEST FOR SDU REPLACEMENT ON THE FIRST STEP. SDU PCN 583-9200 NIL AT GRUJL. CBS E17, E20 AND E21 PULLED OUT AND COLLARED PER MEL PROCEDURES. REPLACESDR UALA2012091405199Fan · faultySMOKE SMELL NEAR DOOR 3L. TURNED OFF UPPER RECIRC. AFTER SELECTING UPPER RECIRC FAN SWITCH OFF CREW WAITED TO REE VALUATE AND REPORTS ODOR HAS CLEARED. ELECTRICAL TYPE ODOR NO VISIBLE SMOKE, CONCENTRATED NEAR DOOR 3L-3R AREA. FOUND C-B B5 AT P210 POPPED AFSDR UALA2012091305183Idg · malfunctionedON ARRIVAL CHECK FOUND MAINTENANCE PAGE CHAPTER 24 RIGHT ENGINE OIL FILTER BLOCKED. FOUND RIGHT ENGINE IDG INOP. DEFER PER MEL, PER MEL REQUIRED DISCONNECTED RIGHT ENGINE IDG AND SERVICED IDG. IDG DELTA P INDICATOR WAS EXTENDED. THE IDG WILL NEED TO BE REPSDR UALA2012091305159Connector · not seatedF/O'S RADIO TUNING PNL "HF-AM" LIGHT STUCK ON, "VHF-L" & "VHF-R" BUTTON LIGHTS DO NOT ILLUMINATE WHEN SELECTED. TRIED SWAPPING PNLS AND RESET AIMS CPM-COMM, NO HELP. RESEATED CONN, OPS-CHECKED NORMAL.SDR UALA2012091305184Probe · faultyDURING REFUELING FOUND RIGHT MAIN FUEL TANK QTY INDICATION INTERMITTENT BETWEEN 40,000 TO 57,000 LBS. DRIPSTICK READING CARRIED OUT. FUEL QTY MAINT PAGE SHOW TANK UNIT RIGHT MAIN 11, 12, 13 SHOW 0.0-0.8. TANK UNIT, PCN 483-0030 EXPEDITED. REPLACED FQPU, NOSDR UALA2012091305182Control Panel · faultyMODE CONTROL PANEL LANE STATUS MESSAGE DISPLAYED. REPLACED MODE CONTROL PANEL.SDR UALA2012091305160Fastener · looseRE CF9051 NR 1 ENGINE HAS LOOSE FASTENER NR 15 ON STRUT AFT HEATSHIELD SEAL. INTERIM REPAIR ACCOMPLISHED PER MT54-UA1 ON BOLT NR 15. MF8513 CREATED TO RECHECKED EVERY 3 SVC UNTIL CF9051 CLEARED. PER MT54UA1 AND ALSO MM 54 -54-03, PERM REPAIR WAS DONE AT LASDR UALA2012091105101Gcu · faultyELEC GEN SYSTEM LEFT IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; GENERATOR CONTROL UNIT (L) HAS AN INTERNAL FAULT. DB-GENERSDR UALA2012091305164Idg · faultyCHAPTER 24 MAINT SYN PAGE SHOWS RIGHT IDG FILTER * BLOCKED *. DELTA P IS POPPED ON IDG. REPLACED NR 2 IDG, LEAK, OPS CHECKED, DISCONNECTED & RECONNECTED IDG.SDR UALA2012091305163Module · faultyBOTH UPPER AND LOWER EICAS SCREENS MOMENTARILY BLINK OFF. ACCOMPLISHED TEST OF LEFT AIMS M1010 FAULT CODE 31- 81057 PRESENT. SUSPECT CPM-GG. REPLACED LEFT AMIS M010 CPM-GG REF AMM. OPS CHECKS NORMAL.SDR UALA2012091305162Rivet · looseLEFT ENGINE HAS LOOSE RIVET IN EXHAUST CONE AT 6 O'CLOCK POSITION ON DATA PLATE.SDR UALA2012091305161Cap · missingHIGH VOLTAGE CAP MISSING CAPTS SIDE. SECURED CAP WITH TAPE PER AMM 30-41-03.SDR UALA2012091205147Charger · faultyBATTERY CHARGER APU STATUS MSG. CB K12 PULLED AND COLLARED. REPLACED APU BATTERY CHARGER, CHECKED OKAY.SDR UALA2012091205146Battery · faultyAPU BATTERY STATUS MSG. NO TIME FOR TROUBLESHOOTING. MEL APPLIED. REPLACED APU BATTERY, REF AMM. CHECKED OKAY.SDR UALA2012091105098Unknown · malfunctionedCENTER TANK RT REFUEL VALVE ACTUATOR CLOSED DURING REFUELING. DF FOR BASE ACTION. -INF- :TRIED NEW IRP NO HELP. RE-INSTALLED OLD IRP, NEEDS MORE TROUBLESHOOTING. REPLACED REFUEL VALVE CONTROL UNIT, NO HELP.SDR UALA2012091105096Unknown · malfunctionedFUEL IS MAKING ITS WAY FROM RT TANK TO CTR TANK. ACCOMPLISHED FUEL SCAVENGE FUNCTIONAL TEST TASK 28-22-00-720-802 UP TO PAGE 526 STEP 5 NEED TO CONTINUE STEP 5 ON FROM PAGE 526. COMPLETED AMM. FOUND NO DEFECTS; NEED TO CONTINUE WITH FIM 28-22 TASK 849.SDR UALA2012091005083A/C Pack · contaminatedFLIGHT CABIN CREW REPORTS ACRID SMOKEY SMELL IN THE FIRST CLASS GALLEY AREA FOR 5 MINS. FOUND STRONG SMELL COMING FROM FIRST CLASS OVEN R11. REPLACED OVEN. ON APPROACH INTO IAD, PURSER REPORTED STRONG ACRID SMELL IN FIRST CLASS AREA, F. FA OPENED OVERHEAD SDR UALA2012091005079Control Valve · faultyELECTRICAL ODOR IN GALLEY, FLIGHT DIVERTED. PILOT BUNK ROOM. TURNED OFF GALLEY POWER. ODOR WENT AWAY IN GALLEY AND BUNK AREA, THEN ADDITIONAL ODOR THROUGHOUT COCKPIT AND CABIN. RAN BLEED AIR, BOTH PACKS AND RECIRC FANS WITH NO ODOR. TURNED ON ALL GALLEY ESDR UALA2012091305192Exciter · faultyRIGHT ENGINE IGNITOR 1 INOPERATIVE. FLIGHT CREW COMPLIED WITH MEL. REPLACED R1 IGNITOR PLUG PER MM. REPLACED NR 1 EXCITER PER MM. REPLACED NR 1 IGNITOR PLUG CABLE PER MM. RAN ENGINE ON NR 1 IGNITOR ONLY, OPS CHECK GOOD.SDR UALA2012091005094Panel · malfunctionedELMS P310 CHANNEL ONE, BUT NOT BOTH, OF THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) 310 PANEL CHANNEL IS FAULTY. RPL- :GOT MSG 24-13092. REPLACED M24406A1 PER MM, OPS TEST NORMAL, NO STATUS MSG PRESENT.
Back to Boeing 777-222