Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012082004642Shutoff Valve · failedTRIM AIR PRSOV L LEFT TRIM AIR PRESSURE RELIEF SHUT OFF VALVE (PRSOV) FAILED. STATUS MSG-2124201 ACTIVE CL MODE MSG-2124201 ACTIVE CL MODE. REPLACED TRIM PRSOV PER MM, OPS GOOD.SDR UALA2012082104665Structure · leakingCREW REPORT HIGH PITCH CONSTANT WHINE IN GENERAL AREA OF DOOR 3 L-R. THE NOISE WENT AWAY DURING DESCENT. DF794 SATCOM COOLING FAN DEFERRED AS POSSIBLE CAUSE BUT NOISE IS STILL PRESENT ON NEXT FLIGHT AFTER DEACTIVATION. SEE CH3599 OPBLM. PRESSURIZED CABIN PESDR UALA2012082104666Unknown · malfunctionedRIGHT HF NOT TRANSMITTING. DEFER PER MEL 2311H. TRANSCEIVER PCN 583-9006 REPLACED, NO HELP PER MM.SDR UALA2012082004640Actuator · leakingON WALKAROUND FOUND FUEL DRIPPING OUT OF LEFT ENGINE. MAINT REPORTED DRIPPING 40 DPM FROM TCC ACT DRAIN NR 2. TCC ACT TO BE REPLACED WITHIN 2C. REPLACED TCC ACTUATOR PER MM. OP CHECK & LEAK CHECK OKAY.SDR UALA2012082004647Idg · faultyDRIVE LIGHT ILLUMINATED ON LEFT ENGINE GENERATOR DRIVE WAS MANUALLY DISCONNECTED. REPLACED IDG PER AMM. LEAK CHECK AFTER ENGINE RUN. SERVICED IDG. NEED STEP 2J PER AMM.SDR UALA2012082004646Fitting · leakingELEC GEN OFF L LEFT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF AND ENGINE NOT SHUT DOWN. ADVISORY MSG01- NOT ACTIVE CRUISE MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (L) FREQUENCY IS LOW. DB- GENERATOR CONTROL UNIT (L) MSG02- LATCHSDR UALA2012081704591Relay · inoperativeNR 2 ENGINE IGNITION DOES NOT PASS AMM, OPS CHECKED K74202 XFR-R RELAY INOPERATIVE.SDR UALA2012082104649Battery · faultyMAIN BATTERY CHARGER AND BATTERY VOLTS READING LOW. REPLACED MAIN BATTERY CHARGER AND MAIN BATTERY PER MM. BATTERY VOLTS AND CHARGER CHECKS OKAY.SDR UALA2012082004628Module · faulty"FMC L" STATUS MESSAGE DISPLAYED. FOUND AS SOC MAINT MSG 31-51023. NEEDS CPM-ACMF PER MAINT TASK FAULT ISOLATION PROCEDURE. REPLACED CPM-ACMF IAW AMM.SDR UALA2012082004627Smoke Detector · faultyEICAS MESSAGE AFT CARGO SMOKE DETECTION ZONE 1 ILLUMINATED. REMOVED AND REPLACED AFT CARGO LOWER SMOKE DETECTOR PER AMM. TEST FAILED, CHANNEL 2 INTERNAL FAULT LOWER AFT MESSAGE 26-20022. CURRENTLY NO STATUS OR EICAS MESSAGE. AFT CARGO PIT MAY BE USED. SDR UALA2012082004629Hinge · brokenDOOR FOR COMPARTMENT AT LOCATION 502 MISSING. REMOVED BROKEN HINGE. REPLACED THE BROKEN HINGE, OPS CHECKED OKAY.SDR UALA2012081704588Connector · defectiveFOUND ELECTRICAL CONNECTOR ON R1 IGNITION EXCITER LOCKING FUNCTION DEFECTIVE WHILE WORKING DF0616. REPLACED CONNECTOR. COMPLETED AND PASSED MAT TEST REF MM 74-00-00, OPERATIONAL TEST OF IGNITION SYSTEM STILL NEEDS TO BE COMPLETED.SDR UALA2012081604564Converter · faultyALL 6 DISPLAY UNITS AND CDU BLANKING. REPLACE BACKUP CONVERTER (M24008) MAT SHOWS LAST FLT LEG DURING DESCENT MAIN BUS (R) VOLTAGE LOW. MAINT MSG 24-44090, HAS HIT 6 LEGS THIS MONTH. REPLACED UNIT, SYSTEM CHECKS NORMAL.SDR UALA2012081604544Actuator · out of positionFWD CROSSFEED VALVES IS NOT IN THE COMMANDED POSITION. REPLACED FWD CROSSFEED VALVES AND OPS CHECKED GOOD.SDR UALA2012081504527Engine · making metalAPU CONTROL STATUS MESSAGE. AFTER TROUBLESHOOTING REMOVED ALL THREE CHIP DETECTORS AT APU AND FOUND ALL TO BE BADLY CONTAMINATED WITH METAL. APU NOT USEABLE. REPLACED APU PER MM. OPS AND LEAK CHECKED GOOD.SDR UALA2012081304444Engine · overtempLT ENGINE EGT EXCEEDANCE, IN AREA C, BEFORE NEXT FLIGHT ACCOMPLISH VISUAL CHECKS AND HOT SECTION BORESCOPE PER AMM 72-00-00. REPLACED NR 1 ENGINE.SDR UALA2012081304380Apu · smokeAPU AUTO SHUTDOWN AT GATE, SMOKE FROM TAILPIPE IMMEDIATELY AFTER SHUTDOWN. INSPECTED APU, FOUND DAMAGE TO FIBERGLASS SHROUD BELOW COMPRESSOR SCREEN. INSPECTED APU COMPARTMENT FOR DAMAGE, FOUND NONE, TAILPIPE WAS CLEAN, APU ACCESS DOORS CLOSE AND LATCH NORMALSDR UALA2012080904325Hose · wornRT MAIN FWD HYD RETURN LINE COVER FRAYED-RUBBING ON GEAR STRUT DURING RET. SUPPLEMENTAL DATA UPDATE, INTERIM REPAIR PER GPM 1- 0-13-008 PG 4 ITM 3.D.6 MADE BY USING SPLITTING SHRINK TUBING AND VINYL TAPE AND SECURING WITH .040 SAFETY WIRE. REF IPC 32-41-0 02 SDR UALA2012081004341Unknown · unknownEGT (ENGINE) FLUCTUATES. LEFT ENG EGT INTERMITTENTLY VARIES FROM 426 TO 230 REF FIM 77-21 TASK 804. CLEANED AND SECURED ALL CONNECTORS IN EGT SYS REF FIM 77-21. ACCOMPLISHED A 5 MINUTE IDLE RUN AND THE EGT INDICATION WAS SOLID. MAINTENANCE TASK AS PER FISDR UALA2012081004340Guide · damagedPER RAMP FWD PIT GUIDE ON BALL MAT WON'T LOCK. REPLACED NR 6 GUIDE, OPS CHECKED GOOD.SDR UALA2012081304368Seal · rupturedBLEED LEAK R DUCT LEAK IN BLEED AIR DUCTING IN RIGHT WING INBOARD FIXED LEADING EDGE, OR RIGHT PACK BAY UP TO CENTER ISOLATION VALVE. REPLACED RT PACK PLENUM DUE TO DUCT SEAL RUPTURE. REPLACED RT PACK DIFFUSER ASSY, OPS CHECKED GOOD.SDR UALA2012081004342Connector · damagedDURING TAXI IN-EICAS EQUIP COOLING. REPINNED PIN 5 ON CONNECTOR DB21581 AND REPLACED THE FLT DECK LOW FLOW DETECTOR.SDR UALA2012081004361Wire · chafedDAMAGED WIRES LOCATED IN THE CABIN BELOW THE STOW BIN BS 697 RT SIDE. WIRES FOUND BURNED AND SEVERED. WIRES CHAFED ON A CUTOUT ON A REINFORCEMENT PANEL WHICH IS PART OF THE STOWBIN END CAP STRUCTURE. REPLACED WIRES W6163-0141, 0143, 0144, 0145, REF SWPM 20SDR UALA2012081004360Target · out of adjustL1 PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND FLT LOCK RELAY SENSOR DISAGREEMENT. ADJUSTED FLIGHT ENGAGED PROXIMITY SWITCH TARGET PER AMM. CHECKED GOOD.SDR UALA2012080904323Diffuser · leakingBLEED LEAK R DUCT LEAK IN BLEED AIR DUCTING IN RIGHT WING INBOARD FIXED LEADING EDGE, OR RIGHT PACK BAY UP TO CENTER ISOLATION VALVE. SUPPLEMENTAL DATA UPDATE, BLD LEAK BECAME BLD LOSS BODY-WING R MSG-2637103 INACTV ER INTER MSG-2639102 INACTV ER INTER. REPSDR UALA2012080904322Valve · faultyECON COOL VALVE RIGHT PACK ECONOMY COOLING VALVE NOT IN COMMANDED POSITION. STATUS MSG01- ACTIVE CRUISE MODE DEPENDENT; ECONOMY COOLING VALVE (R PACK) IS NOT IN COMMANDED POSITION. DB- CABIN TEMPERATURE CONTROLLER (R CHAN2) MSG-2124902 ACTIVE ER MODE. REPLASDR UALA2012080804283Shutoff Valve · faultyRT ENG PRSOV FAULTED. REPLACED RT ENGINE PRSOV PER MM.SDR UALA2012081004343Valve · faultyZONE C TEMP CONTROL TARGET TEMP BLANK AT C ACCOMPLISHED AND ZONE C TRIM AIR VALVE FAILED ON GROUND TEST PRIOR SUSPECT ZONE TRIM MODULATING VALVE.SDR UALA2012080904326Amplifier · faultySATCOM MESSAGE HIGH GAIN AMP. REPLACED HIGH GAIN AMP AND SDU. DID NOT REPLACE SDU. NO PART AVAILABLE AT ORD.SDR UALA2012080804297Warning Light · false activationDET ZONE 3 CARGO FWD STATUS MSG. ACCOMPLISHED FIM TASK 26-16 T804, NO MSG DISPLAYED, NO EXISTING OR PRESENT LEG FAULTS. ACCOMPLISHED FWD CARGO SMOKE DETECTOR SYSTEM TEST, TEST PASSED. OK PER FIM TASK 26-16 T 804.SDR UALA2012080804298Shoulder Belt · stickingSHOULDER HARNESS PROBLEM, STICKS. REPLACED CAPTAINS HARNESS, OPS CHECKED GOOD.SDR UALA2012080704254Module · intermittentLOWER CDU BLINKING. -31-81051 AND LEFT AIMS MODULE CPM-GG M010 INTERNAL FAULT FLASHING ACTIVE AND NOT ACTIVE AS DATA ON DISPLAYS BLINKS ON AND OFF. REPLACED LEFT AIMS CPM-GG MODULE 10 REF MM AND RELOADED ALL SOFTWARE. MSG NOT ACTIVE. DISPLAYS OP NORMAL.SDR UALA2012080804295Battery · failedAPPROX 30 MINUTES AFTER GROUND POWER HOOKED UP, SMOKE EXITING E/E EXHAUST. OPENED E/E DOOR AND SMOKE IN AREA. BATTERY BOX RED HOT. ALSO NOTE AIRCRAFT LOG 6. REPLACED MAIN BATTERY AND BATTERY CHARGER. BATTERY STILL IN PROCESS OF FULLY CHARGING. NEED TO VESDR UALA2012080804299Panel · damagedRIGHT ENGINE INBOARD AFT PYLON PANEL HAD HINGE PINS REMOVED SO WHEN IT WAS OPEN PANEL FELL TO FLOOR DAMAGING CORNERS OF PANEL. APPLIED REPAIR PLIES TO OUTER SIDE. WHEN CURE IS COMPLETE, WILL NEED FILLER PLIES AND LAY UP ON INNER SIDE, REF SRM 54-50-70 REPAIRSDR UALA2012080904327Jack · damagedFLIGHT INTERPHONE INOPERATIVE. REPLACED FLIGHT INT PHONE JACK REF WDM 23-41-13, OP CHECKED NORMAL.SDR UALA2012080704252Idg · faultyLEFT GENERATOR INOPERATIVE, FLT DIVERTED. REPLACED IDG. FLUSHED SYSTEM, LEAK AND OPS CHECKED GOOD DURING ENGINE RUN.SDR UALA2012081304382Valve · faultedAIR SYNOPTIC, TARGET TEMPERATURE INDICATION IS BLANK CREW COMMENTS, AIR COND RESET WILL BRING BACK INDICATION BUT THEN ALWAYS BLANKS AGAIN MAT FAULTED ZONE TRIM MOD VALVE FOR ZONE C MSG. 21-2004 RENDERED ZONE C TRIM MOD VALVE INOP PER MEL 21590.SDR UALA2012080704255Valve · faultedBLEED FAMV LT ON STATUS PAGE. TRIED RUNNING NR 1 ENG WITH NO HELP. REMOVED AND REPLACED NR 1 ENG FAMV, OP CHECKED PER MMSDR UALA2012080604195Engine · unknownON ENGINE START NR 1 OIL PRESSURE 121, NR 2 152, EGT 480 AND CLIMBING NO ROLL BACK ON NR 1. ACCOMPLISHED NORMAL START. ALL PARAMETERS NORMAL AT IDLE.SDR UALA2012080704245Drive Unit · failedWINDSHEAR SYSTEM EITHER PREDICTIVE OR REACTIVE WINDSHEAR ALERTING FUNCTIONS ARE FAILED SUCH THAT WINDSHEAR ALERTING CAPABILITY IS REDUCED OR NOT AVAILABLE. A REACTIVE WINDSHEAR FAILURE WILL ONLY SET THE MESSAGE WITH THE REACTIVE WINDSHEAR OPTION ACTIVE. ADVISDR UALA2012080604185Engine · faultyREF L ENG EGT EXCEEDANCE. REPLACED NR 1 ENGINE IAW AMM 72-00-00 PAGE 623 CONFIG 2.SDR UALA2012080604200Keypad · inoperativeCOCKPIT DOOR ENTRY PAD WILL NOT ALERT WHEN USING 1 ENTER. REPLACED KEYPAD PER MM.SDR UALA2012080604176Electronic Unit · failedFLIGHT ACCESS KEY PAD DOES NOT SOUND OFF WHEN TRYING TO ENTER. RESEAT DOOR ELECTRONICS UNIT. OPS OKAY.SDR UALA2012080604170Oven · smokeFLIGHT ATTENDANTS REPORT SMOKE FROM BUSINESS CLASS GALLEYS. SUPPLEMENTAL DATA UPDATE, PERFORMED GENERAL VISUAL INSPECTION OF BUSINESS GALLEY AS PER AMM 25-31-02. NOTHING FOUND. CABIN CREW SAW WHITE SMOKE COMING FROM INSIDE THE OVENS R31 E R32, THROUGH OVENSDR UALA2012080604224Controller · faultyRT ENGINE IDLE IS INOPERATIVE. INSTALLED NEW CONTROLLER, TESTED GOOD, IDLE RAN ENGINE. ALL SYSTEM NORMAL, NO FAULTS NOTED.SDR UALA2012080604223Battery · failedAPU BATTERY FAILED. REPLACED BATTERY. APU BATTERY WEAK MESSAGE CLEARED. THEN APU BATTERY CHARGER INTERNAL FAULT MESSAGE BECAME ACTIVE. REPLACED BATTERY CHARGER MESSAGE CLEARED. OPS CHECKS GOOD. APU BATTERY MSG REOCCURED.SDR UALA2012080604156Tire · wornLEFT MLG AFT INBD TIRE WORN. REPLACED TIRE.SDR UALA2012080604210Heat Shield · damagedNR 2 ENGINE HAS TWO 1 INCH SEGMENTS MISSING FROM THE 2ND GAP PROTECTOR FROM THE FRONT OF THE HEATSHIELD. SEGMENTS MISSING ARE AT THE 12 O'CLOCK POSITION. INSTALLED ALL NEW NR 2 ENG AFT FAIRING HEAT SHIELD SEGMENTS NR 1 THRU NR 6.SDR UALA2012080604209Battery · weakMAIN BATTERY WEAK STATUS MESSAGE DISPLAYED. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM.SDR UALA2012080104132Relay · burnedAFTER SWITCHING FROM APU TO GROUND POWER, POWER DROPPED OFF WITH ELECTRICAL BURNING ODOR IN E/E BAY AND FLIGHT DECK. FOUND AT P300 AUX PANEL, SOURCE OF BURNED ODOR. CONTACT RELAY ON PANEL WAS BURNED. REMOVED CONTACT C24335 AND FOUND D432 DAMAGED AND RELAY C
Back to Boeing 777-222