Boeing 777-224
Service difficulty reports · 1,592
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2022050401133None · failedB777-33-3-2019 DR L3 EMER LT PWR PACK BATTERY M33400 CAPACITY CH ECK FAILED TRANSFER REF HX NON-ROUTINE WO.694930 AND ORIGINATED BY V920592 DOOR L3 EMER LT POWER PACK BATTERY M33400 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL IAW AMM 33-51-06 WORK ACCOMPSDR CALA2022050401131None · noneRIGHT NOSE GEAR LOW TIRE PRESSURE INSPECTED AND FOUND # 2 NOSE TIRE PRESSURE READING 186 PSI , TIRE ASSY SERVICEABLE, SERVICED TIRE PRESSURE TO 205 PSI, MONITOR FOR FEW HOURS, NO DROP TIRE PRESSURE NOTED. REF AMM 32-45-00.SDR CALA2022042101048Shroud · damagedRIGHT ENGINE ABRADABLE SHROUD AT 9 O''CLOCK POSITION: MATERIAL MISSING, DIMENSION IS 0.75 INCH X 1 INCH X 0.14 INCH DEEP. PERFORMED ABRADABLE SHROUD INSPECTION PER AMM TASK 72-24-00-200-802-G00. AREA OF MISSING MATERIAL IS WITHIN LIMIT AND OK FOR UNLIMITED FLISDR CALA2022042101047Fitting · crackedAD 2013-08-02 SUPPORT TASK EA 5510-01896 REV C OP 005 1EA CRACK WAS FOUND ON LH ELEVATOR O/B ACTUATOR FITTING APPROX 2 3/4 IN LENGTH ATRADIUS AREA AS MARKED. PLS PRINT & ACCOMPLISH OP 09 OF THS EA. TRANSFER REF.NON-ROUTINE HX NRC WO.699257 AND ORIGINATED BY EMSDR CALA2022042101045Battery · dischargedMAIN BATTERY IS DISCHARGING AFTER ENGINE START SWAPPED A/C MAIN BATTERY AND BATTERY CHARGER WITH APU BATTERY 24-31-06. APU BATTERY CHARGER CONSIDERED INOP. C/W MEL 2431D. APU BATT CHARGER DEFERRED PER MEL 2431D, M-PROCEDURE PERFORMED, AND BATTERY CHARGER PER ASDR CALA2022041400987Door Frame · gouged(MED 4 LEFT AFT OF DOOR CUTOUT APPOX 8 INCH AFT AT LAP SKIN JOINT FOUND A GOUGE .DAMAGED IS APPROC 2" X 1/4" AN D 1/16 " DEEP AT THE DEEPEST POINT AT THE EDGE).PER ECRA 5330- 06934 REPAIR HAS BEEN ACCOMPLISHED AND REQUIRES "PLANNING TO CONTACT ENGINEERING ASDR CALA2022040400876Packing · leakingCREW REPORTS "HYD QTY LOW C" ADVISORY MESSAGE WITH CENTER HYDRAULIC QTY DROPPING AND CURRENTLY AT .37. TOMC BILSKI. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN THE CESDR CALA2022033100836Battery Pack · noneR3 DOOR INTERIOR AFT ENERGENCY LIGHT AND EXTERIOR LIGHT INOP. REMOVED AND REPLACED EMERGENCY POWER SUPPLY CHARGER ASSY CAUSING THE LIGHT TO STAY ON,BUT DIDN''T HAVE A BATTERY PACK IN STOCK, WHICH IS ALSO BAD. REF AMM 33-51-00. PART REQUIRED M/E PART # 99-3351-SDR CALA2022032500783Door · not reportedCONTROL CENTER REPORTS THE CREW REPORTED FORWARD CARGO DOOR INDICATION PROBLEM. A/C IS DOING AIR-RETURN TO IAH REQUEST MEL FOR FORWARD CARGO DOOR INDICATION INOP MEL 5271I APPROVED AND APPLIED DDP C/W DOOR INDICATION INOP FOR FWD DOOR DOOR VERIFIED CLOSED CREWSDR CALA2022032500782Pump · failedRIGHT HYD QTY SYSTEM IS LOW EMG R EDP FAIL AND LEAK OCCURRED. REPLACED ENG R EDP. AFTER MAINT ACTION COMPLETED SERVICE HYD SYS R TO FULL LEVEL IN ACC AMM TASK 12-12-01-610-802 REV 94 . LEAK CHECK DONE .NML UPLIFT HYD FLUID 52 LTR NOW IND 1.06SDR 2022F00161None · crackedTOTAL LOSS OF R/H HYDRAULIC SYSTEM. DIVERSION BACK TO FRA. FOUND CRACKED ENGINE DRIVEN PUMP. CHANGE OF AFFECTED EDP AND FILTER.SDR CALA2022032100735Bolt · missingPDA 3 PDA INSPECTION FOUND, WING TO BODY FAIRING 191DL ONE BOLT MISSING ON LEFT AFT CORNER INSTALLED NEW BOLT. CHECKED THIS AREA. NO DAMAGE FOUND. REF GMM 02-30-95 ADD EMP:U175071SDR CALA2022030700589None · crackedAD 2019-11-02 SUPPORT TASK EA 5310-06900 REV D OP 14 2EA HOLE FOUND CRACKS ON CENTER TANK RHS FRONT SPAR LOWER CHORD (DETAIL REFER NDT INSPECTION FINDING RECORD) TRANSFER REF. NON-ROUTINE HX NRC WO.548134 AND ORIGINATED BY EMP NO. V925917 1 TO 26, ATTACHED TO SDR CALA2022022400490Reservoir · usedDURING ACCOMPLISHMENT OF W/C 85-5211-1-9800. FOUND EPASS BOTTLE AT L1 DEPLETED. REMOVED AND REPLACED L1 ENTRY DOOR RESERVOIR BOTTLE. REF AMM 52-11-20. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1107678 SN OFF 0115 ACCOMPLISHED AND VERIFIED RII INSP REQUIREMENTSDR CALA2022022100454Stringer · crackedAD 2019-11-02 SUPPORT TASK EA 5310-06900 OP4 REV D FUSELAGE BS 1035 R/H BUILT-UP UNDERWING LONGERON FOUND 1EA CRACK AT FIRST LAYER (COUNT FROM I/B) PLEASE PRINT AND ACCOMPLISHED EA 5310- 06900 OP 4 TRANSFER REF. NON-ROUTINE HX NRC WO.535988 AND ORIGINATED BY ESDR CALA2022021400373None · noneAD 2019-11-02 SUPPORT TASK REF EA 5310-06900 REV D OP 14 1EA HOLE FOUND CRACK AT RING CHORD LAYER AFT FACE 8 O''CLOCK POSITION LOOKING FWD 0.020" IN DEPTH (DETAIL REFER NDT INSPECTION FINDING RECORD) TRANSFER REF. NON-ROUTINE HX NRC WO.548156 AND ORIGINATED BYSDR CALA2022021100365Steering Sys · failedMAIN GEAR STEERING EICAS ON TAKEOFF COMPLIED WITH MEL FOR LOCKING STEERING ACT. ALL MEL TASK ACCOMPLISHED REFERENCE FIM 31-51 TASK 892 . AHM UPDATE:ACFT REPORTED CORRELATED MMSG: 31-78130 - MAIN GEAR STEERING CONTROL UNIT STEERING LOCKED SIGNALS DO NOT AGREE.SDR CALA2022021100359Skin · crackedSUPPORT TASK : RH BS 1035 FUSELAGE SKIN FOUND 1 EA CRACK AROUND FASTENER HOLE APPROX 1.25" IN LENGTH DETAIL REFER ATTACHED REPOR T TRANSFER REF HX NON-ROUTINE WO.551106 AND ORIGINATED BY EMP V9 24733 FUSELAGE SKIN STA 993-1035 STR 35R - 38R INTERIM REPAIR AS PSDR CALA2022020400319Warning System · false indicationCREW REPORTS LOW SPEED ABORT AT 80 KNOTS DUE TO AURAL WARNING THAT AIRCRAFT WAS ON A TAXIWAY. AC WAS ACTUALLY ON RUNWAY 9R. CREW ALSO REPORTS THEY NORMALLY RECEIVE AURAL NOTIFICATION WHEN APPROACHING A RUNWAY AND THERE WAS NONE WHEN THEY APPROACHED 9R. TERRAINSDR CALA2022012400217Smoke Detector · warning lightSMOKE LAV EICAS 3R LAV RESET SMOKE DETECTOR, OPS CHECK OK. NO PREVIOUS HISTORY.SDR CALA2021122302435Charger · inoperativeB777-33-3-7019 L/H DR2 M33096 EMER LIGHTING BATT PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC ZGX508085 AND ORIGINATED BY EMP V902113. L/H DR2 M33096 EMER LIGHTING BATTERY AND CHARGER REPLACED. BATTERY PACK CAPACITY CHECKED NORMAL AS PER AMM 33-5SDR CALA2021122302434Battery Pack · inoperativeB777-33-3-7019 R/H DR2 M33098 EMER LT BATT PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC ZGX508093 AND ORIGINATED BY EMP V902113. R/H DR2 M33098 EMER LT BATTERY REPLACED AND CAPACITY CHECKED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANISDR CALA2021112502172Potable Water · closedNO WATER PRESS FROM 2L FWD IN BOTH LAVS AND GAL LIES.AFT LAVS/GA LLIES OK FOUND POTABLE WATER VALVE AT 4LEFT ABOVE DOOR IN THE CLOSED POSTION. SEE PHOTO ATTACHED. MOVED VALVE HANDLE TO OPEN POSTION. PURGED AIR FROM ALL GALLEYS AND LAVS AND WATER PRESSURE GOOSDR CALA2021110402034Skin · noneDUE TO THE MAJOR REPAIR AT STATION 1985-2000 AND STRINGER 30L. AN ESFR(SIGNIFICANT FINDINGS REPORT) NEEDS TO BE SUBMITTED. REF BASE NR 000490297 UPDATED WRITEUP TO RII COMPLETED ESFR 7138978 VERIFIED ESFR 7341139 WAS SUBMITTED. UPDATE THE CORRECT ESFR NUMBER ISDR CALA2021110102016None · noneMAIN GEAR STEERING STATUS MESSAGE VERIFIED MAIN GEAR STEERING CYLINDERS ARE LOCKED, DEFERRAL MAIN GEAR STEERING LOCKED PER MEL, DEFERRED FOR TROUBLESHOOTING. REQUESTED DUE TO SHORT GROUND TIME. MEL 3253A APPROVED, AFTER TROUBLESHOOTING WE COULDNT RECREATE THE SDR CALA2021101801920None · leakingOIL PRESSURE INDICATION (ENGINE) AMBER FIM TASK REF : G1 79-98 TASK 803 CMC MSG# 7931492 FLIGHT STATUS: A INTERMITTENCE CODE: M PH: CRUISE NARRATIVE: ELECTRONIC ENG CONTROL (FADEC)(R ENG,CH A) CMC MSG# 7931492 FLIGHT STATUS: A INTERMITTENCE CODE: M PH: CRUSDR CALA2021101401886None · noneON TO ABORT. RED EICAS MSG MAIN GEAR CONFIG ABORT 20KTS CONTACT TOMC WITH FINDINGS UNLOCKED FOR SIGNOFF WITH FINDINGS/CORRECTIVE ACTION. MSG #32-63020 SHOWS LATCHED. REF FIM 32-53 TASK 810. VERIFIED BOTH MLG STEERING ACTUATOR LEVERS ARE SET TO STEER POSITION ASDR CALA2021100601787Battery Pack · dischargedDOOR R1 EMERGENCY LIGHT BATTERY PACK FOUND CAPACITY LOW DURING D EEP CYCLE,REFER HAECO NON-ROUTINE LP:9459702,ORIGINATED BY EMP V 905359,SPEC NO.B777-33-3-7019. PERFORMED BY EMP V903672,REPLACED DOOR R1 EMERGENCY LT BATTERY P ACK AND PERFORMED OPERATIONAL TESTSDR CALA2021100601792Battery Pack · dischargedDOOR R2 EMERGENCY POWER SUPPLY BATTERY PACK M330898 CAPACITY CHE CK FOUND FAILED,REFER HAECO NON-ROUTINE LP:9455160,ORIGINATED BY EMP V905359,SPEC NO.B777-33-3-7019. PERFORMED BY EMP V903672,ORIGINATED BY EMP V903672,REPLACED DOOR R2 PACK M33098 AND PERFORMED SDR CALA2021100601791Battery Pack · dischargedDOOR L3 EMERGENCY LIGHT BATTERY PACK M33400 FOUND CAPACITY LOW D URING DEEP CYCLE,REFER HAECO NON-ROUTINE LP:9459704,ORIGINATED B Y EMP V905359,SPEC NO.B777-33-3-7019. PERFORMED BY EMP V903672,REPLACED DOOR L3 PACK M33400 AND PERFOR MED OPERATIONAL TEST OF THESDR CALA2021092801699None · noneMIN GEAR STEERING EICAS ON TAKEOFF ROLL. BOTH WARNING AND CAUT ION DEFERRED MAIN GEAR STEERING PER MEL 3253A. DDP COMPLIED WITH. MLG STEERING INOP DEFERRED MAIN GEAR STEERING PER MEL 3253A. DDP PROCEDURES FOLLOWEDSDR CALA2021092201634None · noneWINDSHEAR WARNING CAUSED A LOW SPEED ABORT 80 KNOTS DISCUSSED LOW SPD ABOUT 80 KNOTS FOR WINDSHEAR SYS EICAS DURING TO ROLL. WEATHER RADAR SYSTEM NOW TESTING NORMAL BUT AS PRECAUTIONARY PLACING ON MEL 3443D PREDICTIVE WINDSHEAR INOP .BRAKE TEMP NOW AT MINIMUM SDR CALA2021092001612Seat Track · corrodedB777-53-3-0139 - BULK CGO AREA STA1937 TO STA1958 S-35L TO S-36L VACUUM BLOWER EXHAUST VENT SKIN FOUND CORROSION. TRANSFER REF. NON-ROUTINE LP 9131017 AND ORIGINATED BY V897008. BULK CARGO AREA STA 1937 TO STA 1958 STR 35L TO STR 36L VACUUM BLOWER EXHAUST VENTSDR CALA2021091701595Battery · no testSUPPORT TASK - DR L4 EMER LIGHT PWR SUPPLY M33407 BATTERY PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE LP 9131496 AND ORIGINATED BY EMP V902113. DR L4 EMER LIGHT PWR SUPPLY M33407 BATT PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHSDR CALA2021091701594Battery · no testSUPPORT TASK - DR R2 EMER LIGHT PWR SUPPLY M33098 BATTERY PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE LP 9131495 AND ORIGINATED BY EMP V902113. DR R2 EMER LIGHT PWR SUPPLY M33098 BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLSDR CALA2021091701593Battery · no testB777-33-3-7019 DR 2L EMER LIGHT PWR SUPPLY M33096 BATTERY PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE LP 9130078 AND ORIGINATED BY EMP V898181. DR 2L EMER LIGHT PWR SUPPLY M33096 BATT PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISSDR CALA2021090301499Battery · dischargedPERFORM EMERGENCY LIGHT BATTERY PACK CAPACITY FUNCTIONAL CHECK F OUND L/H DOOR 1 BATTERY M33424 POOR CAPACITY - ORIGINATED BY EMP V905497 ON HAECO NR 9450521, SPEC NO.B777-33-3-7015. PERFORMED BY EMP V905497, DOOR 1 L/H M33424 BATTERY REPLACED AND PERFORM OPERSDR CALA2021090301498Battery · dischargedPERFORM EMERGENCY LIGHT BATTERY PACK CAPACITY FUNCTIONAL CHECK F OUND L/H DOOR 1 BATTERY M33093 POOR CAPACITY. - ORIGINATED BY EM P V905497 ON HAECO NR 9450518, SPEC NO.B777-33-3-7015. PERFORMED BY EMP V905497, DOOR 1 L/H BATTERY M33093 REPLACED AND PERFORM OPSDR CALA2021090301496Battery · dischargedPERFORM EMERGENCY LIGHT BATTERY PACK CAPACITY FUNCTIONAL CHECK F OUND L/H DOOR 4 BATTERY M33407 POOR CAPACITY - ORIGINATED BY EMP V905497 ON HAECO NR 9450522, SPEC NO.B777-33-3-7015. DOOR 4 L/H M33407 BATTERY REPLACED AND PERFORM OPERATIONAL TEST FOUND ''OK'',SDR CALA2021082701439Relay · arcedGATE RETURN SMOKE IN THE CABIN. FOUND ELECTRICAL ARCING ON THE P300 PANEL UPON ASESSMENT OF DAMAGE TO P300 PANEL, REMOVED AND FOUND RELAY K24002 GROUND SERVICE SELECT RELAY SEVERELY DAMAGED, SUSPECT INTERNAL FAILURE. NO FOD NOTED IN AREA. REFERENCE SSM 24-22-4SDR CALA2021080601272Charger · failedB777-33-3-7015 - DR 3L EMER LIGHT POWER M33406 SUPPLY BATT CAPACITY TEST FAIL.SDR CALA2021080601271Charger · failedB777-33-3-7015 - DR 2L EMER LIGHT POWER SUPLY M33096 CAPACITY CHECK FAIL TRANFER FROM NR LP 9130404 AND ORIGINATED BY EMP V898181SDR CALA2021080601270Charger · failedB777-33-3-7015 - DR 3L EMER LIGHT POWER SUPPLY M33400 CAPACITY CHECK FAIL TRANSFER FROM NR LP9130402 AND ORIGINATED BY EMP V898181SDR CALA2021080601269Charger · failedB777-33-3-7015 - OHAR EMER LIGHT POWER SUPPLY CAPACITY CHECK FAIL TRANSFER FROM NR LP9130403 AND ORIGINATED BY EMP V898181SDR CALA2021072801202Skin · bulgedSKIN IS BULGING AND HAS PULLED THROUGH FASTENER AT STA 246, OUTBD OF RIGHT NOSE LANDING GEAR DOOR. TOMC LOCKING FOR MX FERRY REMOVED FASTENERS AND REMOVED CORROSION. FLANGE IS 100% CORRODED. UNLOCKING NEED TO PERFORM DVI OF LOWER CHORD AND SURROUNDING AREA REFSDR CALA2021072601190Battery · dischargedPERFORM DEEP-CYCLE EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK F OUND BATTERY M33096 POOR CAPACITY REF HAECO NON-ROUTINE NO.: 944 4852, ORIGINATED BY EMP V905497, SPEC NO.: B777-33-3-7019. PERFORMED BY EMP V903172, REPLACED EMERGENCY LIGHT BATTERY M3309 6 AND SDR CALA2021072601186Battery · dischargedTEST FOUND OHAR BUNK1-3 EMERGENCY LIGHT INOP. REPLACED THE CABIN OHAR AREA EMERGENCY POWER SUPPLY M33123 AND OP TEST CARRIED OUT FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 92.SDR CALA2021072601185Battery · dischargedPERFORM DEEP-CYCLE EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK F OUND BATTERY M33099 POOR CAPACITY. REPLACED THE EMERGENCY LIGHT BATTERY M 33099 AND CARRIED OUT OPERATIONAL TEST FOUND NORMAL AS PER AMM 3 3-51-06-960-802 REV 92.SDR CALA2021072601184Battery · dischargedPERFORM DEEP-CYCLE EMERGENCY LIGHT PACK CAPACITY CHECK FOUND BAT TERY M33094 POOR CAPACITY , REPLACED EMERGENCY LIGHT BATTERY M3309 4 AND CARRIED OUT OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51 -06-960-802 REV 92.SDR CALA2021072601183Battery · dischargedPERFORM DEEP-CYCLE EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK F OUND BATTERY M33097 POOR CAPACITY. REPLACED THE CABIN R.H 2 DOOR AREA E MERGENCY POWER BATTERY M33097 AND OPERATIONAL TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 92.
Back to Boeing 777-224