SDR CALA2018020400470Wire Harness · damagedCREW REPORT SEAT 21D HAS A LOOSE POWER WIRE THAT HAS BEEN CHAFFED BY THE SEAT MOVEMENT. THE WIRE DID ARC AND A SMELL OF ELECTRICAL ODOR WAS APPARENT. INSTALLED SEAT POWER MODULE HARNESS AT 18ABC TO 19ABC IAW AMM 23-32-00. IFE VIDEO, AUDIO AND HANDSETS OPS CHECSDR CALA2018020200435Battery Pack · inoperativeEMERGENCY POWER SUPPLY M33406 BATTERY PACK FOUND INOPERATIVE. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018020200434Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK CAPCITY LOW. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018020200432Lamp · inoperativeDURING AN A CHECK, FOUND SEAT 8A EMERGENCY CELLING LIGHT INOPERATIVE. REPLACED THE LAMPS AND TESTED OK IAW AMM 33-51-00 .SDR CALA2018020200431Lamp · inoperativeDURING AN A CHECK, FOUND THE R2 DOOR EMERGENCY CEILING LIGHT INOPERATIVE. REPLACED THE LAMPS AND TESTED OK IAW AMM 33-51-00.SDR CALA2018020200433Light · inoperativeMED 2L EXTERIOR EMERGENCY LIGHT INOP RELAMPED, OPS CHECKS GOOD. REF AMM 31-51-04-960-801SDR CALA2018012600324Fuse · failedDURING A CHECK, FOUND THE R4 EMERGENCY LIGHT INOPERATIVE. FUSE CHANGED AND CHECKED OK.SDR CALA2018012100271Battery Pack · inoperativeR2 DOOR POWER ASSIST BATTERY INDICATOR LIGHT INOPERATIVE. NO GREEN BLINKING LIGHT. R & R EMERGENCY POWER ASSIST SYSTEM BATTERY PACK IAW AMM 52-11-20SDR CALA2018012100268Oven · odorOVEN 108 IN A ZONE HAS STRONG BURNING SMELL WHEN ON. REMOVED AND REPLACE OVEN 108 IAW AMM 25-34-00. OPS CHECK GOOD.SDR CALA2018012000253Power Supply · no testDURING AN A CHECK, FOUND THE GALLEY EMERGENCY LIGHT INOPERATIVE. REPLACED THE POWER SUPPLY M33096, BATTERY & CHARGER IAW AMM 33-51-06. LIGHT TESTED OK.SDR CALA2018011900229Battery · inoperativeEMERGENCY FLASHLIGHT AT THE L1 DOOR INOPERATIVE. REPLACED THE BATTERY. OPS CHECKED NORMAL.SDR CALA2018011300177Oven · odorOVEN 705 HAS A BURNING ODOR WHEN ON, RESETED THE OVEN CIRCUIT BREAKER AND HEAT, NO BURNING ODOR. CHECKED GOOD.SDR CALA2018011200141Connector · meltedELECTRICAL BURNING ODOR IN LAVATORY G. FOUND MELTED FLOURECENT TUBE CONNECTOR. REMOVED AND REPLACED THE BALLAST AND LIGHT SOCKET IAW AMM 33-26-00. OPS CHECKED NORMAL.SDR CALA2018011200140Unknown · odorSMELLED ELECTRICAL BURNING ODOR AROUND B ZONE. LASTED ABOUT 10 MINUTES, THEN GONE. INSPECTED B ZONE LAVATORY, GALLEY, SEATS, LIGHTS AND CEILING DUCTS IAW AMM 05-51-58-800-801C3, SIMULATED AIR MODE TO INSPECT R, AND L2 DOOR HEATERS. NO EVIDENCE OF SMOKE ODORSDR CALA2018010800100Battery · failedR2 DOOR SLIDE ASSIST. GREEN INDICATOR LIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY IAW 52-11-25. GREEN STATUS LIGHT, OPS CHECKED NORMAL.SDR CALA2018010500043Battery Pack · dischargedR2 DOOR FWD SIDE EMERGENCY LIGHT BATTERY PACK FOUND TO HAVE LOW VOLTAGE. THE BATTERY PACK AND CHARGER WERE REPLACED, OPS TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018010500042Battery Pack · dischargedL3 DOOR CTR SIDE M33406 EMERGENCY LIGHT BATTERY PACK FOUND TO HAVE LOW VOLTAGE. THE BATTERY PACK AND CHARGER WERE REPLACED IAW AMM 33-51-06, OPS TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018010500041Battery Pack · dischargedR1 DOOR EMERGENCY LIGHT BATTERY PACK FOUND TO HAVE LOW VOLTAGE. THE BATTERY PACK AND CHARGER WERE REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018010500040Battery Pack · low voltageR3 DOOR AFT SIDE M33401 EMERG LIGHT BATTERY PACK FOUND TO HAVE LOW VOLTAGE. THE BATTERY PACK AND CHARGER ASSY WERE REPLACED, OPS TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018010500039Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK FOUND TO HAVE LOW VOLTAGE, L1 AFT SIDE M33424. THE BATTERY PACK AND CHARGER WERE REPLACED, OPS TESTED NORMAL IAW AMM 33-51-00.SDR CALA2017123104711Slide · obstructedDOOR 3R SLIDE WILL NOT DISARM REMOVED DEBRIS ON BOTTOM EDGE OF DOOR, OPS CHECKS GOOD ON DISARM AND ARM. OK TO CONTINUE.SDR CALA2017123104707Hinge · crackedDOOR 1L LOWER DOOR HINGE DAMAGED (CRACKED). INSTALLED DOOR CASTING P/N 131W1301-1117 TO DOOR ASSY REF IPC 52-11-06-01 AND SOPM 20-11-00. VERIFIED INSTALLATION OF L1 DOOR CASTING TO DOOR ASSY. REF: IPC 52 -11-06-01 AND SOPM 20-11-00.SDR CALA2017123004685Light · brokenEMERGENCY LIGHT LENS BROKEN. INSTALLED A NEW LIGHT OPS CHECKED OK.,SDR CALA2017122904659Lamp · inoperativeDURING AN A CHECK, FOUND SEAT 2D EMERGENCY LIGHT BROKEN. REPLACED THE LAMPS IAW AMM 33-51-05.SDR CALA2017122904658Lamp · inoperativeDURING AN A CHECK, FOUND THE EXETRIOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-50-00.SDR CALA2017122804634Lamp · inoperativeDURING AN A CHECK, FOUND TWO OVERHEAD CREW REST EMERGENCY LIGHTS INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-15.SDR CALA2017121604477Lamp · inoperativeR1 DOOR SLIDE LIGHT HAD AN INOPERATIVE LAMP. REPLACED AND TEST CARRIED OUT GOOD IAW AMM 33-51-04.SDR CALA2017121504464Lens · missingON CHECK FOUND EMER LT COVER MISSING EMER LT COVER REPLACED IAW AMM 33-51-00SDR CALA2017121304432Power Supply · faultyFOUND EMERGENCY LIGHT OUT ON TOP OF BUNKER NR 5. REMOVED AND REPLACED POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD.SDR CALA2017120804348Battery · inoperativeL1 F/A EMERGENCY FLASHLIGHT BATTERY INOP. REMOVED AND REPLACED BATTERY ASSY AT L1 F/A EMERGENCY FLASHLIGHT ASSY.OPS NORMAL.SDR CALA2017120804349Latch · looseSLIDE PACK COVER LATCHES LOOSE ON THE L2 DOOR SLIDE COVER. FITTED THE COVER IAW AMM 25-66-06.SDR CALA2017120304296Chiller · malfunctionedCHILLER 6.7.8 PLASTIC SMELL WHEN ON. REPLACED AFT CHILLER 6 OPS CK NORMAL REF IPC 25-33-03-11 NO EXISTING SMELL AROUND GALLEY AREA OK TO CONTINUE.SDR CALA2017120104252Unknown · odorELECT ODOR ENTERING AFT GALLEY BOTH SIDES.. PERFORMED INSPECTION OF AFT GALLEY ELECTRICAL EQUIPTMENT AND AROUND AFT LAVS. COULD NOT DUPLICATE SMELL.SDR CALA2017120104260Flashlight · inoperativeDR.1 LEFT EMERGENCY TORCH INOP.REPLACED EMERGENCY FLASH LIGHT INBOARD LEFT 1 DOOR. CHECK GOOD.SDR CALA2017120104259Battery Pack · weakSEAT 33JKL CEILING EMER LT FOUND DIM SEAT 33JKL CEILING EMERGENCY LIGHT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ADD EMP:V898560SDR CALA2017120104258Battery Pack · inoperativeREF NR LP 9130826 SUPPORT TASK - DR L3 OVERWING EMER LIGHT FOUND DIM DOOR L3 OVERWING EMERGENCY LIGHT BATTERY PACK AND CHARGER REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06SDR CALA2017112304193Flashlight · inoperativeR1 DOOR AREA FLASHLIGHT INOPERATIVE. THE FLASHLIGHT WAS REPLACED.SDR CALA2017111904148Battery Pack · inoperativeROWS 1-5 SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. TROUBLESHOT IAW FIM 33-51-00, AND SSM 33-51-12. REMOVED AND REPLACED THE BATTERY PACK AND POWER SUPPLY, M33094. OPS CHECKED OK.SDR CALA2017111704097Oven · smokeOVEN 110 FWD GALLEY BEGAN SMOKING. REPLACED THE OVEN. OPS CHECKED NORMAL. NO DEFECTS NOTED.SDR CALA2017111003994Fuse · inoperativeDURING CHECK, FOUND ZONE B SEAT MOUNTED EMERGENCY LIGHTS NOT ILLUMINATED. THE POWER PACK FUSE WAS REPLACED AND LIGHTS TESTED OK IAW AMM 33-51-01.SDR CALA2017111003993Battery Pack · dischargedSEAT 22JKL EMERGENCY LIGHT FOUND DIM. THE POWER SUPPLY BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2017111003992Battery Pack · inoperativeSEAT 10 LK EMERGENCY LIGHT FOUND DIM. THE POWER SUPPLY BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2017111003995Sign · looseSIGN AT THE R3 DOOR FOUND DETATCHED FROM CEILING. SECURED THE SIGN. OK.SDR CALA2017110603933Socket · burnedTRANSIENT SMOKE LAVATORY ADVISORY MESSAGE DURING DESCENT WITH AN ELECTRICAL ODOR. FOUND FLUORESCENT LIGHT BULB SOCKET BURNED IN THE LAVATORY BY THE L2 DOOR. REPLACED THE SOCKET. ALSO CHANGED THE LIGHT BALLAST AS PRECAUTION IAW AMM 33-26-00-960-806 AND THE LASDR CALA2017102703809Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE AT THE L4 DOOR. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR CALA2017102703810Lamp · inoperativeDURING AN OPS CHECK, FOUND THE EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMP AND TESTED IAW AMM 33-51-00.SDR CALA2017102703774Skin · dentedFUSELAGE EXTERNAL SURFACE DENTED BS 1884, BETWEEN STRINGERS 45 - 47R. REPAIRED THE SKIN IAW ECRA 5330-06210.SDR CALA2017101503628Carbon Seal · leakingNR 1 ENGINE LEAKING OIL. REMOVED AND REPLACED DAMAGED BACK-UP GENERATOR CARBON SEAL, MATING RING AND ASSOCIATED O-RINGS..HIGH POWER, LEAK CHECKED GOOD..OK TO CONTINUE IAW 72-64-01SDR CALA2017101303576Overheat Sensor · failedEAI VALVE RT AND ANTI-ICE LOSS ENG RT EICAS STATUS MESSAGES. EMERGENCY DECLARED. REPLACED THE RIGHT ENGINE FAN CASE OVERHEAT DETECTOR IAW AMM 26-18-01-400-805-001. INSTALLATION TEST GOOD. ACCOMPLISHED ENGINE RUNNING TEST IAW AMM 30-21-00-730-804-001. TESTEDSDR CALA2017101303588Oven · smokeOVEN 109 IN THE FORWARD GALLEY HAD SMOKE AND A BURNING ODOR DURING FLT. REMOVED AND REPLACED OVEN, OPS CHECKED NORMAL IAW AMM 25-34-00.
Back to Boeing 777-224