Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777F16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777F16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2026091800884Flashlight · no testCAPT'S PORTABLE FLASHLIGHT TESTED INOP. R & R FLASHLIGHT IAW AMM 25-64-01/201. OPS CHECKED GOOD. MDDR 259343 CLEARED.SDR UIEA2026091700880Flashlight · no testCA EMERGENCY FLASHLIGHT DOES NOT TEST. REMOVED AND REPLACED THE EMERGENCY FLASHLIGHT IAW AMM 20-10-00 AND 25-64-01. OPS CHKD GOOD, NO FURTHER DEFECTS NOTED.SDR UIEA2026090600854Extinguisher · expiredPORTABLE WATER FIRE EXTINGUISHER EXPIRED. R & R PORTABLE WATER FIRE EXTINGUISHER FWD IAW AMM 26-26-02, REV 107, & IPC 26-26-02-01, REV 25. NO FURTHER DEFECTS NOTED.SDR UIEA2026090300850Test Light · inoperativeFO FLASHLIGHT TEST LIGHT INOPERATIVE. OPS CHECK PERFORMED IAW AMM 25-64-01-710-801. OPS CHECKED GOOD, NO ISSUES NOTED.SDR UIEA2026082600800Seal · brokenCAPT LIFE VEST TAMPER SEAL BROKEN. REMOVED AND REPLACED THE LIFE VEST IAW AMM 25-62-01-960-005. OPS CHKD OK.SDR UIEA2026081400756Bulb · inoperativeCAPTAIN FLASHLIGHT INOPERATIVE. TRANSFER TO MDDR 257506 PER MEL 25-64-02C CAT C. R/R CAPT FLASHLIGHT AND HOLDER IAW AMM 25-64-01. OPS CHK AND FUNCTIONAL CHK GOOD. THIS CLEARS DMI 257506. PLACARDS REMOVED.SDR UIEA2026072400647Contact · dirtyFO`S FLASHLIGHT GREEN LIGHT INOPERATIVE. CLEANED ELECTRICAL CONTACTS & OPS CHK FLASHLIGHT PRESS TO TEST, NORMAL IAW AMM 25-64-01. FLASHLIGHT TURNS ON NML</P>)SDR UIEA2026070600574Panel · out of positionL1 DOOR PANEL NOT FLUSH. FOUND L1 DOOR EPAS BATTERY SAFETY SWITCH AT DISARM POSITION. ARMED EPAS BATTERY SAFETY SWITCH IAW AMM 52-11-20. AFT HINGE COVER ON L1 IS FLUSH AND DOOR OPS CHK NORMAL.SDR UIEA2026061500500Button · inoperative1ST OBS O2 MASK RESET BUTTON INOPERATIVE. SWAPPED 1ST OBS O2 MASK & STOWAGE BOX WITH 2ND OBS O2 MASK & STOWAGE BOX PER AMM 35-11-19 & IPC 35-11-18-01. OPS & LEAK CHKD OK. R & R 2ND OBS O2 MASK BOX ASSY IAW AMM 35-11-18 REV 107 & IPC 35-11-18-01 REV 24. LEAK SDR UIEA2026051100310Battery · inoperativeCAPTAIN FLASHLIGHT HOLDER LIGHT TEST INDICATION INOP. TRANSFER TO DMI 252376 PER MEL 25-64-02C CAT C. REMOVED AND REPLACED BATTERY PACK CAPT'S SIDE IAW AMM 25-64-01. OPS CHKD OK.SDR UIEA2026040800151Placard · unsecureRIGHT SIDE EVAS OPEN FOR EMERGENCY USE ONLY PLACARD NOT SECURED(<P>FO EVAS INSP OK AND R/R TAMPER SEAL PER AMM 25-60-99 REV 106. NO FURTHER DEFECTS NOTED. DMI 250620 CLOSED.</P>)SDR UIEA2026033000115Seal · brokenCAPTAIN'S EVAS SEAL BROKEN. INSTALLED MISSING TAMPER SEAL IAW AMM 25-64-00. NO FURTHER DEFECTS NOTED.SDR UIEA2026030200071Oxygen Bottle · inoperativePORTABLE OXYGEN BOTTLE, LOCATED IN SUPERNUMERARY GALLEY CABINET IS INOPERATIVE. R & R THE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-00. LEAK CHKD GOOD.SDR UIEA2026030200072Hose · leakingFOUND OXYGEN LEAK ON 1ST OBSERVER MASK BOX HOSE. REMOVED AND REPLACED THE 1ST OBSERVER O2 MASK BOX HOSE IAW AMM 35-11-00. PERFORMED A LEAK CHECK, NO LEAKS NOTED. OPS CHECKED GOOD.SDR UIEA2026030100070A/C Pack · odorDESCENDING THROUGH 10500 FEET, STRONG OIL TYPE SMELL IN BLEED AIR AIR CONDITIONING SYSTEM, STRONGER IN COCKPIT(<P>T/S OIL SMELL IN CABIN IAW B777 FIM 21-00 TASK 808, NO SMOKE OR OIL SMELL FOUND. PERFORMED HIGH POWER RUNS FOR BOTH ENGINES IAW B777 AMM 71-00-00,SDR UIEA2026021700062Battery · faultedFO'S FLASHLIGHT FLASHING RED. REMOVED AND REPLACED FO'S FLASHLIGHT BATTERY IAW AMM 25-64-01. OPS CHECK GOOD.SDR UIEA2026020800046Flashlight · no testCAPT EMERGENCY FLASHLIGHT INDICATES RED WHEN PRESS TO TEST TO SEE IF FLASHLIGHT WORKS(<P>REMOVED AND REPLACED THE CAPTAIN'S PORTABLE FLASHLIGHT IAW AMM 25-64-01. OPS CHK OK</P>)SDR UIEA2026021080046Flashlight · faultedCAPTAIN`S EMERGENCY FLASHLIGHT INDICATES RED WHEN PRESS TO TEST TO SEE IF FLASHLIGHT WORKS. TRANSFER TO DMI 247439 PER MEL 25-64-02C CAT C.SDR UIEA2026020900047Oxygen Bottle · overpressuredPORTABLE O2 BOTTLE LOCATED IN EMERGENCY EQUIPMENT CABINET IS OVER PRESSURIZED.(<P>REMOVED & REPLACED PORTABLE O2 BOTTLE LOCATED IN THE EMERGENCY EQUIPMENT CABINET IAW B777 AMM 35-31-00. NO DEFECTS NOTED. IPC REF 35-31-51.</P>)SDR UIEA2026012700017Oxygen Mask · unwanted deployDURING SECURE CHECKLIST, SUPERNUMERARY SWITCH INADVERTENTLY SELECTED. REPACKED SUPERNUMERARY O2 MASKS IAW AMM 35-23-17, VERIFIED SUPERNUMERARY O2 PRESSURE 1510 PSI AND SWITCH RESET IAW AMM 35-23-00/501 AND AMM 35-23-00/601.SDR UIEA2026010200002Medical Kit · damagedMED KIT UNUSABLE, COULD NOT REMOVE THE TAMPER SEAL(<P>R/R MED KIT REF AMM 25-64-50/201. NO FURTHER DEFECTS NOTED. CLOSED DMI 245220</P>)SDR UIEA2025121601347Girt Bar · fodL1 DOOR WILL NOT ARM WITH NORMAL ARMING PROCEDURES. FOUND DEBRIS IN THE GIRT BAR AFTER FLOOR FITTING. CLEANED & ARMING SYSTEM OPS CHECKS GOOD IAW AMM 52-11-00-710-801 & AMM 52-11-00-860-805.SDR UIEA2025103101288Flashlight · inoperativeFLASHLIGHT AT L1 DOOR INOP(<P>R/R FLASHLIGHT PER ATLAS AIR DOCUMENT 777F-25-EEL AND OPS CHECK GOOD IAW AMM 25-64-01.SDR UIEA2025082801146Oxygen System · no discrepancy3RD SEAT OXYGEN TEST DOES NOT SHOW FULL CROSS. TOOK OUT MASK AND TESTED OXYGEN THROUGH MASK. PUT MASK BACK IN BOX AND TESTED IT, OPS CHECK GOOD PER AMM 35-00-00.SDR UIEA2025082601143Flashlight · inoperativeCAPTAIN FLASHLIGHT INOP(<P>R/R CAPT FLASHLIGHT IAW AMM 20-11-00. OPS CHECK GOOD IAW AMM 25-64-01. THIS CLOSES MDDR 236966. PLACARD REMOVED.</P>)SDR UIEA2025082401134Bracket · brokenEMERGENCY EQUIPMENT CABINET LEFT PBE BRACKET BROKEN. SECURED PBE BRACKET FASTENERS IAW SRM 51-40-02. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2025080201078Life Vest · missingDURING DAILY CHK, W/C C-06-001-01-08 FOUND LIFE VEST MISSING AT PAX SEAT BY R1 DOOR. INSTALLED NEW LIFE VEST AS REQUIRED AT PAX SEAT BY R1 DOOR REF W/C C-06-001-01-08. NO FURTHER DEFECTS NOTED.SDR UIEA2025072301007Container · tornSUPERNUMERY LIFE PRESERVER BAG RIPPED OPEN. REPLACED FO SUPERNUMERY FLOTATION DEVICE PER AMM 25-62-01. MDDR 234719 CLEARED. PLACARD REMOVED. NO FURTHER DEFECTS NOTED.SDR UIEA2025071800971Battery Pack · failedRIGHT SUPERNUMERARY FLASHLIGHT BLINKING RED. REMOVED AND REPLACED RT FLASHLIGHT BATTERY PACK IAW AMM 25-64-01. OPS CHECK GOOD. THIS ACTION CLEARS DMI 234387. PLACARDS REMOVED.SDR UIEA2025071200934Flashlight · inoperativeFLASHLIGHT NEAR R1 DOOR INOP. REMOVED AND REPLACED FLASHLIGHT IAW AMM 25-64-01, OPS CHECK GOOD. THIS CLEARS MDDR 234035.SDR UIEA2025070800867Oxygen Mask · obstructedSAFETY HAZARD OXYGEN MASK OBSTRUCTED BY GPS CABLE, O2 IS UNUSABLE.(<P>ROUTED CABLE PER EO 7746A003. DOES NOT OBSTRUCT O2 MASK. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025061400775Flashlight Assy · no testDURING PREFLIGHT CHECK PORTABLE FLASHLIGHT HOLDER DOES NOT TEST WITH TEST BUTTON BY L1 DOOR. REMOVED AND REPLACED FLASHLIGHT EMERGENCY ASSY IAW AMM 25-64-01. OPS CHK GOOD.SDR UIEA2025061100739Switch · brokenFIRST OBSERVER O2 MASK SWITCH BROKEN 2511.(<P>R/R 1ST OBS O2 BOX ASSY IAW AMM 35-11-18. OPS CHECK & LEAK CHECK GOOD. NO FURTHER DEFECTS NOTED. THIS CLEARS DMI 232321. PLACARDS REMOVED.</P>)SDR UIEA2025051800630Oxygen Bottle · leakingCREW O2 LOW.(<P>FOUND UPPER CREW O2 BOTTLE READING 500 PSI AND LEAKING FROM S/O VALVE. REMOVED AND REPLACED UPPER CREW O2 CYLINDER IAW AMM 12-15-08-900-801 REV 104. IPC REFERENCE 35-11-51-01F REV 18. OPS & LEAK CHECK OK. NEXT HYDRO DUE DATE 11/2029.</P>)SDR UIEA2025041200455Flashlight · no testL1 DOOR FLASHLIGHT TEST IS NOT GREEN. R/R FLASHLIGHT PER AMM 25-64-01. OPS CHK GOOD.SDR UIEA2025033100418Door · out of toleranceEXIT POWER DOOR HAS CONSIDERABLE GAP AND IS NOT SITTING FLUSH.(<P>DOOR ADJUSTMENT WITHIN TOLERANCE PER AMM 52-45-01-400. NO DEFECTS NOTED </P>)SDR UIEA2025032400383Oxygen Box · no testFIRST OBSERVER MASK STOWAGE BOX FAILS TO TEST. R & R OBS O2 MASK STOWAGE ASSY PER AMM 35-11-18-52. OPS CHK GOOD. DMI 227712 CLOSED.SDR UIEA2024082000840Power Supply · inoperativeFOUND EMERGENCY LIGHT INOP(<P>1) IAW AMM 33-51-06-960-802 REV 101 R/R EMERGENCY LIGHT BATTERY PACK 1 EACH AT M33093. 2) IAW AMM 33-51-06-960-803 REV 101 R/R EMERGENCY LIGHT POWER SUPPLY 1 EACH AT M33094. 3) IAW AMM 33-51-06-960-802 & 33-51-06-960-803 REV 101 PSDR UIEA2024070980599None · noneDEVIATION FOUND DURING PERFORMING SB 777-57A0122 MODIFICATION.(<P>REMOVE DAMAGE PARTS I.A.W. SRM 51-40-02-0G-0, REV47. PERFORM EI NO T2024A57M-1552 REV 0. ACCOMPLISHED EI NO: T2024A57M-1552 REV 1. CONDITION CHECK NORMAL AND JOB COMPLETED. </P>)SDR UIEA2024041100269Slide · openENTRY L1 DOOR OPENED WHILE STILL ARMED. SLIDE DID NOT DEPLOY(<P>CHKD FOUND DOOR SLIDE DISABLED. SUBSEQUENTLY DOOR SLIDE REMOVED AND ROUTED TO STORES. L1 DOOR STRUCTURE INSPECTION NORMAL. DUE TO NIL PART, TRANSFER TO DMI 206486 IAW MEL 52-11-01-02 CAT C, DUE 20SDR P5CA2024020100003Battery · no testFD EMERGENCY LIGHT OPS CHECK FAILED(<P>R/R FO EMERGENCY FLASHLIGHT ASSY IAW B777 AMM 25-64-01 & 20-11-00. OPS CHECK GOOD. P/N P2-07-0015-003</P>)SDR P5CA2023112800116Unknown · unknownCENTER OBS SEAT SHOULDER HARNESS RETRACTION IS WEAK.(<P>PFMD OPS CHK ON FIRST OBSERVER SEAT SHOULDER HARNESS, OPS CHK SATIS IAW AMM 25-11-03.</P>)SDR P5CA2023092200107Life Vest · unknown#3 SUPER SEAT LIFE VEST DAMAGED(<P>REPLACED WITH SVC LIFE VEST PER AMM 25-64-01. NO FURTHER DEFECTS NOTED</P>)SDR P5CA2023092200106Life Vest · unknownSUPER SEAT #1 LIFE VEST DAMAGED(<P>REPLACED WITH SVC LIFE VEST PER AMM 25-64-01. NO FURTHER DEFECTS NOTED</P>)SDR P5CA2023082300075Cradle · unknownCAPT EMERGENCY FLASHLIGHT BRACKET BROKEN(<P>R/R FLASHLIGHT BRACKET IAW AMM 25-64-01. OPS CHK GOOD.</P> / <P>OFF PN: P2-07-0019-103</P>)SDR P5CA2023080400067Battery · unknownCAPT FLASHLIGHT WILL NOT TEST(<P>REMOVED & REPLACED BATTERY IAW AMM 25-64-01. OPS CHECK GOOD.</P>)SDR P5CA2023071900036Battery · unknownBOTH FLASH LIGHTS IN FLIGHT DECK DO NOT TEST(<P>FLT DECK FLASHLIGHT BATTERIES REPLACED PER AMM 25-64-01 & TEST OK</P> / <P>P/N OFF: P2-07-0021-002 S/N OFF: NSN</P> / <P>P/N ON: P2-07-0021-002 S/N ON: NSN</P>)SDR P5CA2023011300002Stowage Box · no testON CHK, FND 1ST OBS OXY MASK UNABLE TO TEST.(<P>1ST OBS OXY MASK STOWAGE BOX REPLACED AND TEST "SATIS" IAW AMM 35-11-18</P>)SDR P5CA2022102400202Life Vest · tornLIFE VEST BAG TORN(<P>R/R LIFE VEST IAW B777 AMM 25-62-01.</P>)SDR P5CA2022093000188Sign · detachedEXIT SIGN AT L1 DOOR BROKE OFF.(<P>CHECKED AND DEFERRED AFT EMERGENCY LT DOOR 1L LENS BROKEN IAW MEL 33-51-01 CAT C DUE TO 09OCT22, PLACARD INSTALLED. MCC NOTIFIED. TRANSFERRED TO MDDR #172438. 0045Z MJS.</P> / <P> </P> / <P>SUBJ EXIT IND LT ASSY REPLACED AND
Back to Boeing 777F16